Thermal and Mechanical Design of a High-Voltage Power Electronics Package: Preprint

Thermal and mechanical design aspects of a power electronic package with 5-kV GaN devices are presented. Through finite element analyses, the impact of different cooling configurations and device location on the thermal performance and reliability of the package was investigated. It was found that placing the devices closer to the direct-bond-copper substrate as opposed to a centered approach in the proposed double-sided-cooling configuration resulted in improved heat dissipation. This approach also reduced the total number of attachment layers, thereby likely improving the reliability of the package. Furthermore, simulations revealed that the device location had a negligible impact on the thermomechanical behavior of the attachment layers, as they are more prone to the local coefficient of thermal expansion mismatch.

27 ARPA - Advanced Research Projects Agency-Energy↗

Method of manufacturing a complex product by an additive process

A method of producing a complex product includes designing a three dimensional preform of the complex product, creating a three dimensional preform of the complex product using the model, depositing a material on the preform, and removing the preform to complete the complex product. In one embodiment the system provides a complex heat sink that can be used in heat dissipation in power electronics, light emitting diodes, and microchips.

Pascall, Andrew J.↗

Functionally graded thermal vias for inductor winding heat flow control

Embodiments of the disclosure relate to apparatuses for enhanced thermal management of an inductor assembly using functionally-graded thermal vias for heat flow control in the windings of the inductor. In one embodiment, a PCB for an inductor assembly includes a top surface and a bottom surface. Two or more electrically-conductive layers are embedded within the PCB and stacked vertically between the top surface and the bottom surface. The two or more electrically-conductive layers are electrically connected to form an inductor winding. A plurality of thermal vias thermally connects each of the two or more electrically-conductive layers to a cold plate thermally connected to the bottom surface. A number of thermal vias thermally connecting each electrically-conductive layer to the cold plate is directly proportional to a predetermined rate of heat dissipation from the electrically-conductive layer.

Dede, Ercan↗

Hygroscopic cooling tower for waste water disposal

In various embodiments, the present invention relates to heat dissipation systems including a hygroscopic working fluid integrating waste water as makeup water. The present invention also relates to methods of using the same. The present invention also relates to hygroscopic cooling systems adapted to dispose of waste water by combining the waste water with a hygroscopic working fluid, precipitating impurities and evaporating the remaining water.

Martin, Christopher Lee↗

A 4 x 4 SiPM Sensor Array with Fast Preamplified Output Engineered for the PWO Detectors of the EIC EEEMCAL

The PbWO4 scintillation detectors for the Electron-Ion Collider Electron Endcap Electromagnetic Calorimeter (EEEMCAL) cannot use vacuum photomultipler tubes due to the high magnetic field environment. We are presenting a readout solution with a 4 x 4 SiPM array directly coupled to a preamplification and summing stage. A second amplification stage with variable gain and offset adjustments is also included in the compact electronics module. The integrated power supply feeds the signal processing chain and the adjustable bias control. The parameter settings are saved locally on a EEPROM and are adjustable via the integrated communication interface through USB or RS485. The design was optimized to maximize signal collection energy resolution, for fast timing and wide dynamic range while keeping a small footprint with low power consumption and heat dissipation. The output response is fast enough to meet the 100 ? 200 ns digitization gate requirements for the detector. The electronics assembly requires no active cooling and includes a temperature sensor and a gain compensation of thermal variations which are important features for stable operation in large scale detector structures. A detector prototype was constructed with 20 mm x 20 mm x 200 mm PWO crystals affixed with individual SiPM array readouts and arranged in a 3 x 3 array. This detector was tested at the Thomas Jefferson National Accelerator Facility with 5GeV positrons. We will present the results of these detector characterization measurements.

Philip, O.↗

High Fidelity Simulations of Air-Cooled Reactor Cavity Cooling System

High Temperature Gas Reactor (HTGR) designs incorporate passive safety systems (e.g., the Reactor Cavity Cooling System [RCCS]) that utilize natural principles to manage heat dissipation from the reactor pressure vessel (RPV) during accidents or routine shutdowns. The industry community is experiencing a pressing need for advanced simulation tools that can accurately assess the performance of these types of systems. In the literature, a knowledge gap exists concerning high-fidelity data for the RCCS, and this gap is one of the areas of focus of the present study. This research focuses on a specific RCCS designed for General Atomics' Modular High-Temperature Gas Reactor (GA-MHTGR). Experimental studies on a scaled version (can be seen in Figure 1) of the air-cooled RCCS used in GA-MHTGR were conducted by the University of Wisconsin-Madison (UW-Madison). This work contributes to a broader initiative aimed at establishing a numerical benchmark based on the UW-Madison experiments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental Investigation on Cooling performance of A Thermoelectric Freezer

Thermoelectric heat pumps (TEHPs) have found widespread use in the electronics cooling industry and portable refrigerators. However, there has been a lack of extensive research on the application of TEHPs in low-temperature refrigeration settings. To address this gap, various configurations of TEHPs were fabricated to assess their suitability for freezer applications. Key parameters such as cooling capacity and system performance of the TEHPs were crucial in evaluating these configurations. Three configurations, each with different numbers of cooling units and fan arrangements, were tested using a 300-liter freezer prototype under typical room conditions (21°C). A cooling unit is comprised of two-stage thermoelectric modules, an aluminum plate fin heat exchanger sink with fans positioned either on top or directing airflow through the center, and a cooling block with circulating icy water for heat dissipation. Across all configurations, the minimum temperature inside the freezer cabinet reached -16.0°C. The cooling capacity peaked at 74.7 W, with the thermoelectric coefficient of performance (COP) reaching a maximum of 0.45. System COP ranged from 0.23 to 0.28. Minimum TE power consumption was recorded at 138.8 W, with TE system power consumption at 174.4 W, indicating feasibility for practical residential freezer applications. This investigation lays the foundation for integrating TE freezers with ice thermal storage systems.

Hu, Yifeng↗

Transformer with integral inductor

In accordance with one embodiment is a transformer with a core comprising a perimeter portion and central intervening portion. The central intervening portion is separated from the perimeter portion by air gaps, creating an opening on either side of the intervening portion. A primary winding and secondary winding are wound around the central intervening portion of the core. The primary winding is capable of electromagnetic interaction with the secondary winding. A pair of ferrite members arranged outward from a central axis of the central intervening portion of the core and increases a series inductance with the primary winding. In accordance with another aspect of the disclosure, each ferrite member may have an air gap associated with the core to facilitate heat dissipation from the transformer.

Rastogi, Sagar K.↗

Microbubble dynamics and heat transfer in boiling droplets

Dissipating large heat fluxes from a surface is critically important in numerous industrial and natural applications. Boiling based spray cooling and surface texturing are two of the most promising methods being investigated to address this problem. Although our understanding on these topics has significantly improved over past decades, critical gaps remain in the knowledgebase stymieing the realization of their full potential. As an example, while bubble growth in pool boiling have been investigated in detail, comparatively little is known about how the bubbles evolve inside boiling drops. In the present work, we have investigated for the first time, the microbubble dynamics inside water droplets boiling on superhydrophilic textured substrates using high-speed X-ray phase contrast imaging (XRPCI). Our observations show that the transient bubble density variation follows similar characteristics irrespective of the texture spacing at a given surface temperature. For an example microstructure, we found that the number of discrete bubbles on the surface decreases as temperature is increased although their growth rate increases. Here, we observe that bubble growth is highly non-uniform during the lifetime of a drop on the surface. Initially, bubbles grow under diffusion-limited regime, but at later times they grow as ~t 1.45 due to combined effects of coalescence and evaporation. In some conditions, we found that bubbles shrink dramatically af- ter the initial growth spurt presumably due to severe quenching of the surface, and migration of bubbles on the surface. Using the bubble sizes, for the first time we analyzed the heat flux removed by a single bubble and also by all the bubbles at a given time. We find that the highest dissipation through latent- heat component (~600 W/cm 2 ) occurs just in the beginning and thereafter it decreases. We expect that our findings and the analysis would guide further work on the topic and will aid in the overarching goal of engineering surfaces that are more efficient in boiling heat transfer.

42 ENGINEERING↗

Thermohydraulic experiments on a supercritical carbon dioxide–air microtube heat exchanger

Heat exchangers are critical components in supercritical CO 2 Brayton cycles and provide necessary heat input, recovery, and dissipation. Tubular heat exchangers with unconventionally small tube sizes (tube diameters less than 5 mm) are promising components for supercritical CO 2 cycles and potentially provide excellent structural stability with wide scope of application. This paper provides essential design and fabrication guidelines for a compact shell-and-tube heat exchanger with microtubes (with an inner diameter equal to 1.75 mm). A heat exchanger test rig is used to evaluate the thermohydraulic performance of this heat exchanger with supercritical CO 2 and air as working fluids. Thermohydraulic data are reported for more than forty sets of experiments with varying Reynolds numbers for shell and tube flows. Critical performance metrics are calculated from the data and compared with predictions from a previously described numerical model. The average deviations between the experimental and model results fall within 10% for all critical metrics. This excellent agreement validates the numerical model for supercritical CO 2 heat exchanger optimization and scale-up.

42 ENGINEERING↗

Catalytic Enhancement of Inductively Heated Fe 3 O 4 Nanoparticles by Removal of Surface Ligands

Abstract Heat management in catalysis is limited by each material's heat transfer efficiencies, resulting in energy losses despite current thermal engineering strategies. In contrast, induction heating of magnetic nanoparticles (NPs) generates heat at the surface of the catalyst where the reaction occurs, reducing waste heat via dissipation. However, the synthesis of magnetic NPs with optimal heat generation requires interfacial ligands, such as oleic acid, which act as heat sinks. Surface treatments using tetramethylammonium hydroxide (TMAOH) or pyridine are used to remove these ligands before applications in hydrophilic media. In this study, Fe 3 O 4 NPs are surface treated to study the effect of induction heating on the catalytic oxidation of 1‐octanol. Whereas TMAOH was unsuccessful in removing oleic acid, pyridine treatment resulted in a roughly 2.5‐fold increase in heat generation and product yield. Therefore, efficient surfactant removal has profound implications in induction heating catalysis by increasing the heat transfer and available surface sites.

Moura, Natalia S.↗

Internal energy balance and aerodynamic heating predictions for hypersonic turbulent boundary layers

The elemental equation governing heat transfer in aerodynamic flows is the internal energy equation. For a boundary layer flow, a double integration of the Reynolds-averaged form of this equation provides an expression of the wall heat flux in terms of the integrated effects, over the boundary layer, of various physical processes: turbulent dissipation, mean dissipation, turbulent heat flux, etc. Recently available direct numerical simulation data for a Mach 11 cold-wall turbulent boundary layer allows a comparison of the exact contributions of these terms in the energy equation to the wall heat flux with their counterparts modeled in the Reynolds-averaged Navier-Stokes (RANS) framework. Various approximations involved in RANS, both closure models as well as approximations involved in adapting incompressible RANS models to a compressible form, are assessed through examination of the internal energy balance. There are a number of potentially problematic assumptions and terms identified through this analysis. Here, the effect of compressibility corrections of the dilatational dissipation type is explored, as is the role of the modeled turbulent dissipation, in the context of wall heat flux predictions. The results indicate several potential avenues for RANS model improvement for hypersonic cold-wall boundary-layer flows.

42 ENGINEERING↗

Modeling shock-induced void collapse in single-crystal Ta systems at the mesoscales

Understanding the role of microstructural heterogeneities on the shock wave propagation and defect evolution behavior is essential to predicting the dynamic response of metals. Heterogeneities, such as voids, provide challenges to understanding the wave propagation behavior as the shock-void interaction can collapse the void and result in large plastic strains and significant heating (hot spot formation) in the metal. Accurate modeling of this phenomenon requires predicting the void collapse mechanisms and the related heat generation and dissipation mechanisms (hotspot formation) that determine the microstructure evolution. While molecular dynamics (MD) simulations can model the void collapse behavior, the time/length scale capabilities pose a challenge to connect with continuum models or the experimental scales. Here, this study presents the capability of the newly developed quasi-coarse-grained dynamics (QCGD) method that extends the MD simulations to larger system sizes and longer times to model this phenomenon. This study uses QCGD simulations to investigate the mechanisms of shock wave interactions with pre-existing voids in single-crystal Ta microstructures for variations in shock pressures, void size, and loading orientations. For a given orientation, the plasticity contributions and rates of void collapse are observed to vary with shock pressures and void size. The larger void sizes and higher pressures result in increased temperatures (hot spots) and faster void collapse rates and unravel the variations in the plasticity contributions. In addition, QCGD simulations investigate the post-collapse microstructure evolution as a release wave travels through the hot spot region. The simulations reveal that the reduction in temperatures due to heat dissipation initiates the dynamic recrystallization behavior in the hotspot regions.

36 MATERIALS SCIENCE↗

Extreme fast charging of commercial Li-ion batteries via combined thermal switching and self-heating approaches

Abstract The mass adoption of electric vehicles is hindered by the inadequate extreme fast charging (XFC) performance (i.e., less than 15 min charging time to reach 80% state of charge) of commercial high-specific-energy (i.e., >200 Wh/kg) lithium-ion batteries (LIBs). Here, to enable the XFC of commercial LIBs, we propose the regulation of the battery’s self-generated heat via active thermal switching. We demonstrate that retaining the heat during XFC with the switch OFF boosts the cell’s kinetics while dissipating the heat after XFC with the switch ON reduces detrimental reactions in the battery. Without modifying cell materials or structures, the proposed XFC approach enables reliable battery operation by applying <15 min of charge and 1 h of discharge. These results are almost identical regarding operativity for the same battery type tested applying a 1 h of charge and 1 h of discharge, thus, meeting the XFC targets set by the United States Department of Energy. Finally, we also demonstrate the feasibility of integrating the XFC approach in a commercial battery thermal management system.

25 ENERGY STORAGE↗

Recovering the Waste Energy from the Electron-Ion Collider Cooling Water Systems

While only a fraction of the electricity required for the EIC goes into the collision itself, most of the energy ultimately ends up being rejected to the environment via the infrastructure cooling systems. The energy utilized by the RF amplifiers, power supplies, magnets, vacuum systems, and cryogenics systems is rejected to the cooling towers that ultimately dissipate the energy to the atmosphere. Current estimates indicate approximately 50 MW of heat is dissipated at a low temperature by the cooling towers. This technical note is prepared to conceptually demonstrate that feasible options exist to recover the low temperature energy from the EIC cooling water systems.

43 PARTICLE ACCELERATORS↗

Cooling performance of an active-passive hybrid composite phase change material (HcPCM) finned heat sink: Constant operating mode

Here, the present study explores a hybrid thermal management technology based on air cooling and hybrid composite phase change material (HcPCM) filled finned heat sink for cooling performance of lower to medium heat flux dissipating electronic devices. Two-dimensional numerical simulations are conducted to study the conjugate heat transfer effects of three types of finned heat sink: air-cooled finned heat sink, HcPCM-cooled finned heat sink, and hybrid (air-HcPCM) cooled finned heat sink. A heat sink with a constant volume faction of plate-fins is designed in all cases and simultaneous effects of hybrid nanoparticles and air are investigated to keep the heat sink temperature at safe operating conditions between 40–60°C. The effect of air is incorporated into the heat sink by applying the convective heat transfer coefficient of h c = 10–100W /m 2 .K which tends to create the natural convection and forced convection heat transfer characteristics. The heat flux is varied from 25–40kW /m 2 in the current study. The hybrid nanoparticles of carbon additives (GO and MWCNTs) are dispersed into the RT-35HC, used as a PCM, with a volume fraction of 0% to 6%. Transient simulations are carried out using COMSOL Multiphysics to solve the governing equations for PCM based conjugate heat transfer model. The results showed that forced convection heat transfer improved the cooling performance of the hybrid heat sink compared to natural convection heat transfer. The addition of nanoparticles further enhanced thermal enhancement and uniform melting distribution of PCM inside the finned heat sink. The h c between 30 to 50W/m 2 .K shows optimized values for forced convection heat transfer operating conditions. The volume fraction of 2% of GO+MWCNTs nanoparticles in recommended or optimum concentration for uniform melting of PCM inside the finned heat sink.

36 MATERIALS SCIENCE↗

Global impacts of vegetation clumping on regulating land surface heat fluxes

The clumping index (CI) quantifies the non-random distribution of vegetation across space, which regulates the canopy radiative transfer processes and land surface carbon, water, and energy cycles. However, its impact on global surface energy budget, particularly sensible heat fluxes and surface temperature, is not well understood. Additionally, while there have been studies showing significant seasonal variations in CI, the impacts of these variations on surface energy fluxes remain unclear. In this study, we incorporated satellite-derived spatially and temporally explicit CI data into the Community Land Model version 5 (CLM5) to evaluate the effects of CI on global land energy fluxes. Our results showed that including CI increased the global mean sensible heat flux dissipated from ground by 3.9 W m -2 (~18%), while decreasing the global mean vegetation sensible heat flux by 4.9 W m -2 (~65%), resulting in a total sensible heat decrease of 1.0 W m -2 (~3%). In contrast, CI increased the global mean latent heat flux by 0.8 W m -2 (~2%), primarily due to increased evapotranspiration (up to 11 W m -2 ) in tropical regions. We also found considerable impacts of seasonal variations in CI, particularly on sensible heat fluxes from ground and vegetation in evergreen needleleaf forests and deciduous needleleaf forests. Using constant CI rather than considering seasonal variations resulted in significant overestimation and underestimation of the sensible heat fluxes from vegetation and ground, respectively, in boreal summer. In conclusion, these changes in surface energy fluxes caused by CI and its seasonal variations led to up to 1.7 and 0.5 K differences in simulated mean ground temperature. These findings highlight the importance of including CI and considering its seasonal variations in modeling land surface energy fluxes.

54 ENVIRONMENTAL SCIENCES↗

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity