Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEAT GAIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Preparation of 110K (Bi, Pb)-Sr-Ca-Cu-O superconductor from glass precursor

The Bi1.5Pb0.5Sr2Ca2Cu3O(x) glass, prepared by rapid quenching of the melt, showed T(sub g) of 383 C, crystallization temperature of approx. 446 C, melting temperature of approx. 855 C, and bulk density of 5.69 g/cu. cm. in air. The as-quenched glass was oxygen deficient. On heating in O2, it showed a slow, irreversible, and continuous weight gain starting at approx. 530 C. The influence of annealing conditions on the formation of various phases was investigated by XRD and electrical resistivity measurements. The 110K-T(sub c) phase did not form below 840 C. The amount of this phase increased with the sintering time at 840 C. A sample annealed at 840 C for 243 h in air and furnace cooled showed the highest T(sub c) (R=0) of 107.2 K and transition width delta T(sub c) (10 to 90 percent) of approx. 2 K.

Bansal, Narottam P.↗

Interaction Between Tropical Convection and its Embedding Environment: An Energetics Analysis of a 2-D Cloud Resolving Simulation

The phase relation between the perturbation kinetic energy (K') associated with the tropical convection and the horizontal-mean moist available potential energy (bar-P) associated with environmental conditions is investigated by an energetics analysis of a numerical experiment. This experiment is performed using a 2-D cloud resolving model forced by the TOGA-COARE derived vertical velocity. The imposed upward motion leads to a decrease of bar-P directly through the associated vertical advective cooling, and to an increase of K' directly through cloud related processes, feeding the convection. The maximum K' and its maximum growth rate lags and leads, respectively, the maximum imposed large-scale upward motion by about 1-2 hours, indicating that convection is phase locked with large-scale forcing. The dominant life cycle of the simulated convection is about 9 hours, whereas the time scales of the imposed large-scale forcing are longer than the diurnal cycle. In the convective events, maximum growth of K' leads maximum decay of the perturbation moist available potential energy (P') by about 3 hours through vertical heat transport by perturbation circulation, and perturbation cloud heating. Maximum decay of P' leads maximum decay of bar-P by about one hour through the perturbation radiative, processes, the horizontal-mean cloud heating, and the large-scale vertical advective cooling. Therefore, maximum gain of K' occurs about 4-5 hours before maximum decay of bar-P.

Li, Xiaofan↗

Space Shuttle Boundary Layer Transition Flight Experiment Ground Testing Overview

In support of the Boundary Layer Transition (BLT) Flight Experiment (FE) Project in which a manufactured protuberance tile was installed on the port wing of Space Shuttle Orbiter Discovery for STS-119, STS- 128, STS-131 and STS-133 as well as Space Shuttle Orbiter Endeavour for STS-134, a significant ground test campaign was completed. The primary goals of the test campaign were to provide ground test data to support the planning and safety certification efforts required to fly the flight experiment as well as validation for the collected flight data. These test included Arcjet testing of the tile protuberance, aerothermal testing to determine the boundary layer transition behavior and resultant surface heating and planar laser induced fluorescence (PLIF) testing in order to gain a better understanding of the flow field characteristics associated with the flight experiment. This paper provides an overview of the BLT FE Project ground testing. High-level overviews of the facilities, models, test techniques and data are presented, along with a summary of the insights gained from each test.

Karen T Berger↗

TPSAS-NF1676L-19423-DND

In support of the Boundary Layer Transition (BLT) Flight Experiment (FE) Project in which a manufactured protuberance tile was installed on the port wing of Space Shuttle Orbiter Discovery for STS-119, STS-128, STS-131 and STS-133 as well as Space Shuttle Endeavour for STS-134, a significant wind tunnel test campaign was completed. The primary goals of the test campaign were to provide ground test data to support the planning and safety certification efforts required to fly the flight experiment as well as validation for the collected flight data. These test included Arcjet testing of the tile protuberance, aerothermal testing to determine the boundary layer transition behavior and resultant surface heating and planar laser induced fluorescence (PLIF) testing in order to gain a better understanding of the flow field characteristics of the flight experiment. This paper provides an overview of the BLT FE Project ground testing. High-level overviews of the facilities, models, test techniques and data are presented, along with a summary of the insights gained from each test.

Karen T Berger↗

Experimental Capabilities and Achievements of the Space Environment Dynamometer (SED)

The Space Environment Dynamometer (SED) chamber was designed to conduct research in cryobotics; an area of study that focuses on robotic systems and rotating machinery operating in extreme cold environments including Earth, low Earth orbit, Mars, Moon, asteroids, Solar orbit, planetary orbit, or those encountered during travel among these destinations. The test chamber incorporates a modular dynamometer, consisting of a variety of brakes, torque sensors and motors to be easily interchanged between tests. Each test employs a unique test profile that incorporates different setpoints of applied torques and velocities for a given period or number of rev- olutions. The modularity of the dynamometer setup allows for any combination of motor, gearbox to be tested. This chamber is one of a kind and resides at the Swamp Works facility within the Granular Mechanics and Regolith Operations laboratory (GMRO) at NASA Kennedy Space Center. Other cold chambers exist, however they are project specific and do not simultaneously output real time torque, temperature and efficiency data. The modularity of this extreme cold environment test chamber, coupled with the custom software and instrumentation, makes it one of a kind. The chamber is capable of stabilizing cryogenic temperatures and pressures to commensurate moon environments. Tests have successfully been conducted on motors and gearboxes for various cryogenic temperature set points, torques, and angular velocities. Relevant internal temperatures of the test article and chamber were recorded using a variety of temperature sensors. The temperature setpoints, on the motors and gearboxes tested, were stabilized by using PID gain scheduling of the PWM signal for the various heaters. The heat removal for the motor was provided by creating a thermally conductive path from a cryohead directly to the test article using copper straps. A variety of strainwave gears (SWGs), also known as Harmonic drives, planetary gear systems and DC motor actuator configurations have been tested in the chamber. The experiments performed were for various projects including Bulk Metallic Glass Gears (BMGG), Volatiles Investigating Polar Exploration Rover (VIPER), In-Situ Resource Utilization Pilot Excavator (IPEX) . Various upgrades have been made to the extreme cold environment test chamber for the use of cryobotic research. These upgrades greatly increased the autonomous capabilities of the test set up by providing redundancies in the hardware and software. The redundancies were primarily added to protect the integrity of the cryohead. A new strapping and insulation method was performed to create the thermal conductive path from the actuators to the cryohead. The software was upgraded to include temperature setpoint control, further increasing the autonomous capabilities of the test. This paper goes into detail regarding the upgrades made to the extreme cold environment test chamber, as well as highlights the results from a COLDArm acceptance test.

Casey J. Clark↗

Heat-death by volcano - how Venus went rogue?

The idea of a habitable Venus epoch has gained traction in recent years via 1-D and 3-D General Circulation Modeling (GCM) efforts [1,2,3]. Although recent work has supported an alternative permanent hot and dry scenario [4]. However, the habitable scenario presents us with a conundrum - how does a terrestrial planet transform from temperate to hot-house? For decades it was proposed that the gradual brightening of the sun was the probable cause [5]. Yet 4 billion years ago Venus was receiving nearly 1.4 times the insolation that Earth receives today, and many studies have put Earth at the inner boundary of the habitable zone today [6]. The newer 3-D GCM efforts have demonstrated that if Venus had an early habitable period, that the cloud-albedo feedback responsible for maintaining temperate surface conditions [7] could still be in operation today. From this perspective increasing insolation through time cannot be an answer to the transition from habitable to hot-house. We propose that the 'Great Climate Transition' (GCT) was trigged by simultaneous large igneous provinces (LIPs) akin to those like the Siberian Traps responsible for the End Permian [8]. We have taken the most up to date LIP database for Earth [9] and characterized their distribution through time as random or nearly random. Next we initiate a large suite of Monte Carlo simulations based on this record and generate the likelihood for simultaneous, or environmentally overlapping events in this hypothetical setup. We find the probability of such events to be quite high, a probable cause for Venus' GCT, and a possible harbinger of things to come for Earth.

Venus↗

Replication of the Apparent Excess Heat Effect in a Light Water-Potassium Carbonate-Nickel Electrolytic Cell

Replication of experiments claiming to demonstrate excess heat production in light water-Ni-K2CO3 electrolytic cells was found to produce an apparent excess heat of 11 W maximum, for 60 W electrical power into the cell. Power gains range from 1.06 to 1.68. The cell was operated at four different dc current levels plus one pulsed current run at 1 Hz, 10% duty cycle. The 28 liter cell used in these verification tests was on loan from a private corporation whose own tests with similar cells are documented to produce 50 W steady excess heat for a continuous period exceeding hundreds of days. The apparent excess heat can not be readily explained either in terms of nonlinearity of the cell's thermal conductance at a low temperature differential or by thermoelectric heat pumping. However, the present data do admit efficient recombination of dissolved hydrogen-oxygen as an ordinary explanation. Calorimetry methods and heat balance calculations for the verification tests are described. Considering the large magnitude of benefit if this effect is found to be a genuine new energy source, a more thorough investigation of evolved heat in the nickel-hydrogen system in both electrolytic and gaseous loading cells remains warranted.

Niedra, Janis M.↗

Experimental Heat Transfer and Bulk Air Temperature Measurements for a Multipass Internal Cooling Model with Ribs and Bleed

An experimental study was made to obtain heat transfer and air temperature data for a simple three-leg serpentine test section that simulates a turbine blade internal cooling passage with trip strips and bleed holes. The objectives were to investigate the interaction of ribs and various bleed conditions on internal cooling and to gain a better understanding of bulk air temperature in an internal passage. Steady-state heat transfer measurements were obtained using a transient technique with thermochromic liquid crystals. Trip strips were attached to one wall of the test section and were located either between or near the bleed holes. The bleed holes, used for film cooling, were metered to simulate the effect of external pressure on the turbine blade. Heat transfer enhancement was found to be greater for ribs near bleed holes compared to ribs between holes, and both configurations were affected slightly by bleed rates upstream. Air temperature measurements were taken at discrete locations along one leg of the model. Average bulk air temperatures were found to remain fairly constant along one leg of the model.

Thurman, Douglas↗

Performance Evaluation of a Vapor-compression-cycle Based Heat Pump System for a Lunar Habitat under the Impact of Dust Deposits on the Coupled Radiators

Space exploration gains new momentum. A near goal is set by NASA to return humans to the Moon andestablish a sustainable presence on the lunar surface for more repeatable and affordable expeditions.The lunar dust is one of the dangerous environment hazard causing serious problems for explorationactivities. In this paper, in order to study the impact of lunar dust on the performance of a thermalmanagement system for a lunar habitat, a dynamical model of an active thermal control system that iscomprised of a vapor-compression cycle heat pump and a radiator loop is developed. A heat pump to liftthe heat rejection temperature is required due to high lunar daytime surface temperature. Parametricstudies on radiator size, percentage of dust coverage on the radiator, and lunar habitat location arecarried out. The results show that lunar deposits can significantly increase the power consumption ofthe thermal management system. A dust covered radiator panel results in net heat input to the heattransfer fluid during the period of strong solar irradiance, causing deteriorated performance of theradiator loop. The lunar dust contamination problem raises the requirement of redundancy design of asystem for fault tolerance. A synergetic design of a thermal management system, a power generationsystem and robotic maintenance system is proposed to achieve maximal mass cut for a whole lunarhabitat system.

Chunjian Pan↗

Towards Energy Scale Calibration and Drift Correction of TES Detectors for Athena X-IFU

The Athena X-Ray Integral Field Unit (X-IFU) comprises a 2376-pixel array of transition edge sensors (TES) read out with time-division multiplexing (TDM). X-IFU will provide spatially resolved, high-resolution spectroscopy (2.5 eV full-width-half-maximum up to 7 keV) over the energy range 0.2 to 12 keV, with an absolute energy scale accuracy of 0.4 eV. The energy scale function maps the optimally filtered pulse height, in arbitrary engineering units, to real calibrated energy. Uncertainties in the calibration can result from imperfect fitting of the energy scale between the known calibration points. Furthermore, temporal changes in the TES operating environment, such as heat-sink temperature, magnetic field and bias voltage, can cause significant variations in the detector gain function over time. If not properly corrected, this can result in degradation of the energy resolution, and systematic errors in the absolute energy scale. The non-linear nature of TES detectors, coupled with the possibility of multiple simultaneously occurring sources of drift, can make effective corrections over the full bandpass of the instrument extremely challenging. Athena X-IFU will employ an on-board calibration source that provides known reference x-ray lines. This provides real-time monitoring of the gain stability of the detector system and information that can be used to correct for gain drifts. For X-IFU the baseline approach is to measure a series of calibration curves under different environmental conditions, which bound the expected drifts the instrument is predicted to see over the course of the mission. Using the information from the in-flight calibration source, these energy scale functions can be interpolated to generate a new corrected energy scale as a function of time. In this paper we discuss progress towards demonstrating that the X-IFU energy scale requirements can be met. We present measurements on ~ 200 pixels in a prototype X-IFU array read out with 8-column x 32-row TDM. We use a rotating target source containing 12 fluorescent targets to generate x-ray lines covering the energy range 4 keV (Sc-Kα) to 12 keV (Br-Kα). We present measurements of the non-linear energy scale function and show how variations in heat-sink temperature, TES bias voltage and magnetic field affect the shape of TES energy scale differently and introduce different residual gain errors over the bandpass. We explore different drift correction algorithms that use either a single or multiple referential lines to track and correct the gain from these various sources of drift. In addition to the pulse-height, the DC ‘baseline’ level of the TES can contain information about its bias conditions. Thus, we test a multi-parameter gain correction algorithm that attempts to incorporate both the pulse height and the additional baseline information into the algorithm.

Stephen J Smith↗

Postponement of incipient collapse due to work-induced heat stress by limited cooling

Four subjects completed five treadmill training sessions under comfortable to cool conditions and were calibrated to find an optimum combination of speed and grade on the treadmill which would produce a metabolic rate of 2000 Btu-hr. Dressed in an Apollo liquid cooling garment, each man underwent a total of four experiments in which the rate of heat extraction from the liquid cooling garment was adjusted to an amount which would cause a storage within the body of 1000 Btu/hr. Physiological measurements included skin temperature at 9 locations, rectal and ear canal probes, and heart rate. The increases in tolerance time for the various subjects and the various methods of emergency cooling, ranged from a low of six minutes to a high of 48 minutes, or from 8 to 102% of the baseline tolerance times. The largest gains were achieved in a subject whose tolerance endpoint was atypical, and whose baseline heat tolerance was unsually low.

Blockley, W. V.↗

A kinetic theory treatment of heat transfer in plane Poiseuille flow with uniform pressure

Plane compressible Poiseuille flow with uniform pressure (Couette flow with stationary boundaries) is revisited where the Lees two-steam method with the Enskog equation of change is applied. Single particle velocity distribution functions are chosen, which preserve the essential physical features of this flow with arbitrary but uniform plate temperatures and gas pressure. Lower moments are shown to lead to expressions for the parameter functions, molecular number densities, and temperatures which are entirely in agreement with those obtained in the analysis of Lees for compressible plane Couette flow in the limit of low Mach number and vanishing mean gas velocity. Important simplifications result, which are helpful in gaining insight into the power of kinetic theory in fluid mechanics. The temperature distribution, heat flux, as well as density, are completely determined for the whole range of Knudson numbers from free molecular flow to the continuum regime, when the pressure level is specified.

Bahrami, Parviz A.↗

Observed effects of landscape variability on convective clouds

A case is presented in which clouds are observed to form first over a mesoscale-size area (100 x 300 km) of harvested wheat in Oklahoma, where the ground temperature is warmer than adjoining areas dominated by growing vegetation. In addition, clouds are suppressed over relatively long bands downwind of small man-made lakes and areas characterized by heavy tree cover. The observed variability of cloud relative to landscape type is compared with that simulated with a one-dimensional boundary-layer model. Clouds form earliest over regions characterized by high, sensible heat flux, and are suppressed over regions characterized by high, latent heat flux during relatively dry atmospheric conditions. This observation has significance in gaining understanding of the feedback mechanisms of land modification on climate, as well as understanding relatively short-range weather forecasting.

Rabin, Robert M.↗

Apparent Thermal Conductivity Of Multilayer Insulation

Mathematical model of apparent or effective thermal conductivity between two successive layers of multilayer thermal insulation (MLI) offers potential for optimizing performance of insulation. One gains understanding of how each physical mechanism contributes to overall flow of heat through MLI blanket. Model helps analyze engineering tradeoffs among such parameters as number of layers, thicknesses of gaps between layers, types of spacers placed in gaps, weight, overall thickness, and effects of foregoing on apparent thermal conductivity through blanket.

Mcintosh, Glen E.↗

Intelligent Engine Systems: HPT Clearance Control

The Advanced Thermally Actuated Clearance Control System underwent several studies. Improved flow path isolation quantified what can be gained by making the HPT case nearly adiabatic. The best method of heat transfer was established, and finally two different borrowed air cooling circuits were evaluated to be used for the HPT Active Clearance Control System.

Source record↗

Advanced Silicon Avalanche Photodiodes on NASA's Global Ecosystem Dynamics Investigation (GEDI) Mission

Silicon Avalanche Photodiodes (APDs) are used in NASA’s Global Ecosystem Dynamics Investigation (GEDI) which was launched in December 2018 and is currently measuring the Earth’s vegetation vertical structure from the International Space Station. The APDs were specially made for space lidar with a much lower hole-to-electron ionization coefficient ratio (k-factor ~0.008) than that of commercially available silicon APDs in order to reduce the APD excess noise from the randomness of the avalanche gain. A silicon heater resistor was used under the APD chip to heat the device up to 70°C and improve its quantum efficiency at 1064 nm laser wavelength while maintaining a low dark current such that the overall signal to noise ratio is improved. Special APD protection circuits were used to raise the overload damage threshold to prevent device damage from strong laser return by specular surfaces, such as still water bodies, and space radiation events. The APD and a hybrid transimpedance amplifier circuit were hermetically sealed in a package with a sufficiently low leak rate to ensure multi-year operation lifetime in space. The detector assemblies underwent a series of pre-launch tests per NASA Goddard Environmental Verification Standard for space qualification. They have performed exactly as expected with GEDI in orbit. A detailed description of the GEDI detector design, signal and noise model, and test results are presented in this paper.

Sun, Xiaoli↗

Temporal Treatment of a Thermal Response for Defect Depth Estimation

Transient thermography, which employs pulse surface heating of an inspected component followed by acquisition of the thermal decay stage, is gaining wider acceptance as a result of its remoteness and rapidness. Flaws in the component s material may induce a thermal contrast in surface thermograms. An important issue in transient thermography is estimating the depth of a subsurface flaw from the thermal response. This improves the quantitative ability of the thermal evaluation: from one scan it is possible to locate regions of anomalies in thickness (caused by corrosion) and estimate the implications of the flaw on the integrity of the structure. Our research focuses on thick composite aircraft components. A long square heating pulse and several minutes observation period are required to receive an adequate thermal response from such a component. Application of various time-related informative parameters of the thermal response for depth estimation is discussed. A three-dimensional finite difference model of heat propagation in solids in Cartesian coordinates is used to simulate the thermographic process. Typical physical properties of polymer graphite composites are assumed for the model.

Plotnikov, Y. A.↗

A radio altimeter antenna for a planetary probe

The design of a 400 MHz directional radio altimeter antenna for use in a freely falling probe in a planetary atmosphere is described. It is required that the antenna be physically large to exploit the dependence of the return power on the square of the wavelength. The antenna must be deployable so that it can be stowed behind the heat shield during the phase of atmospheric penetration. The electrical requirement, imposed by the power available and the system noise, is that the gain in the direction of the probe be at least 3 dB over a dipole. The altimeter application imposes the requirement of linear polarization. Dipole elements are impractical because of the proximity of the heat shield, hence monopole elements using the heat shield as an integral part (the ground plane) of the antenna are used. A parasitic element is placed behind the driven element to increase both the front-to-back ratio and the directive gain. The antenna which has been selected has a gain of 4 dB over a dipole, a front-to-back ratio of 8 dB, and a -6 dB beam angle of 34 degrees. Experiments for evaluating the effects of element spacing, length, and tilt angle with respect to the probe axis were conducted on a 1/25 scale model of the antenna at 10 GHz, and impedance measurements were performed on a full scale antenna at 400 MHz.

Beyer, J. B.↗