Development of Rene 41 honeycomb structure as an integral cryogenic tankage/fuselage concept for future space transportation systems

The status of the structural development of an integral cryogenic-tankage/hot-fuselage concept for future space transportation systems is reviewed. The concept comprises a honeycomb sandwich structure that serves the combined functions of containing the cryogenic fuel, supporting the vehicle loads, and protecting the spacecraft from entry heating. The inner face sheet is exposed to cryogenic temperature of -423 F during boost; the outer face sheet, which is slotted to reduce thermal stress, is exposed to a maximum temperature of 1400 F during a high-altitude gliding entry. Attention is given to the development of a fabrication process for a Rene 41 honeycomb sandwich panel with a core density of less than 1 percent that is consistent with desirable heat treatment processes for high strength.

Shideler, J. L.↗

Honeycomb mirrors of borosilicate glass - Current results and plans for 7-8m diameter

The making of large astronomical mirrors with borosilicate glass honeycomb structure is discussed. Particular attention is given to a single casting technique for making borosilicate honeycomb mirror blanks up to 7 meters in diameter. Current work on the development of this technique involves the casting of blanks 60 cm in diameter which have the full thickness (33 cm), cell size (15 cm), and faceplate thickness (2.5 cm) needed for a 1.8-m mirror.

Angel, J. R. P.↗

Steps toward eight-meter honeycomb mirror blanks. I Rationale and approach

The best form for 8-m telescope mirrors is discussed. It is concluded that honeycomb sandwich structure can meet the most exacting demand goals for subarcsecond image quality in optical and infrared astronomy. These structures are light, have good stiffness against gravitational and wind loading, and have low thermal inertia. The latter permits them to be operated at the ambient air temperature to avoid local seeing problems. Borosilicate and aluminosilicate glasses are adequate materials for ventilated honeycombs, which do not require low expansion materials.

Angel, J. R. P.↗

Steps toward 8m honeycomb mirrors IV - Some aspects of design and fabrication

The tolerances in glass homogeneity, thermal control, and support of the blank, necessary to meet the requirements of telescopes in the best ground-based sites, are defined for a hypothetical 8-m honeycomb mirror spin-casting facility. Homogeneity in expansion coefficient of 10 to the -8th/C and thermal equilibration to 0.1 C are estimated. Laboratory measurements show that both can be met by a ventilated honeycomb of borosilicate or similar glass. Adequate resistance to wind pressure and buffeting can be achieved by an axial support that responds to pressure on the three defining points. Annealing of the blank at the peak cooling rate of 20 C/day will take about six weeks, leading to a temporary stress of 15 kg/sq cm.

Angel, J. R. P.↗

Steps toward 8m honeycomb mirrors. VIII - Design and demonstration of a system of thermal control

Directed jets of ambient temperature air are proposed for the maintenance of low internal temperature gradients and conformity with ambient temperatures in honeycomb-structure borosilicate glass telescope mirrors. The use of greater airflow on thicker sections, to match cooling rates, and the cooling or heating of the internal, back, and edge surfaces of the mirror at the same rate established by convection on the front surface, have been tested on a full scale glass thermal model of a single honeycomb cell from an 8-m diameter mirror. The internal thermal gradient (less than 0.1 C) and ambient-temperature-change lag (less than 0.24 C) ensure minimum image degradation.

Cheng, A. Y. S.↗

Experimental rotordynamic coefficient results for honeycomb seals

Test results (leakage and rotordynamic coefficients) are presented for seven honeycomb-stator smooth-rotor seals. Tests were carried out with air at rotor speeds up to 16,000 cpm and supply pressures up to 8.2 bars. Test results for the seven seals are compared, and the most stable configuration is identified based on the whirl frequency ratio. Results from tests of a smooth-rotor/smooth-stator seal, a teeth-on-stator labyrinth seal, and the most stable honeycomb seal are compared.

Elrod, David A.↗

Hybrid honeycomb panel heat rejection system

The evolution of a hybrid honeycomb panel heat rejection system concept for future high-power spacecraft is described. Performance evaluation of this heat pipe-based hybrid radiator is based on data and prediction models from a developmental component hardware testing program. The concept integrates three high-performance components into an optimized radiator system. These components are the sideflow heat pipe transport leg, honeycomb panel evaporator, and light-weight high-efficiency heat pipe fins. A 3.05 m (10 ft.) long hybrid radiator was designed considering remnant hardware available from other Hughes programs. The key performance objective for the hybrid radiator was to demonstrate high thermal transport capacity, increased radiating fin lengths, improved thermal efficiency across structural boundaries, and reduced weight. Analysis showed that 9000 W can be transported over a 3.05 m radiator and that finlengths of up to 1 m are possible.

Tanzer, H. J.↗

Friction factor data for flat plate tests of smooth and honeycomb surfaces

Friction factors for honeycomb surfaces were measured with a flat plate tester. The flat plate test apparatus was described and a method was discussed for determining the friction factor experimentally. The friction factor model was developed for the flat plate test based on the Fanno Line Flow. The comparisons of the friction factor were plotted for smooth surfaces and six-honeycomb surfaces with three-clearances, 6.9 bar to 17.9 bar range of inlet pressures, and 5,000 to 100,000 range of the Reynolds number. The optimum geometries for the maximum friction factor were found as a function of cell width to cell depth and cell width to clearance ratios.

Ha, Tae Woong↗

Tools Make Clean Holes In Honeycomb Panels

Three tools designed used together to prepare honeycomb panels for insertion of hardware to support structural members or electronic packages. Tools speed up and simplify time-consuming operation of manually pushing honeycomb material aside to make room for spool-shaped mounting insert. Tools are core cutter, spotface cutter, and displacement tool.

Wells, Dott↗

Titanium honeycomb panel testing

The paper describes the procedures of thermal mechanical tests carried out at the NASA Dryden Flight Research Facility on two tianium honeycomb wing panels bonded using liquid interface diffusion (LID) technique, and presents the results of these tests. The 58.4 cm square panels consisted of two 0.152-cm-thick Ti 6-2-4-2 face sheets LID-bonded to a 1.9-cm-thick honeycomb core, with bearing plates fastened to the perimeter of the upper and the lower panel surfaces. The panels were instrumented with sensors for measuring surface temperature, strain, and deflections to 315 C and 482 C. Thermal stress levels representative of those encountered during aerodynamic heating were produced by heating the upper panel surface and restraining all four edges. After more than 100 thermal cycles from room temperature to 315 C and 50 cycles from room temperature to 482 C, no significant structural degradation was detected in the panels.

Richards, W. L.↗

Double-Lap Shear Test For Honeycomb Core

Double-lap test measures shear strength of panel made of honeycomb core with 8-ply carbon-fiber/epoxy face sheets. Developed to overcome three principal disadvantages of prior standard single-lap shear test: specimen had to be more than 17 in. long; metal face sheets had to be used; and test introduced torque, with consequent bending and peeling of face sheets and spurious tensile or compressive loading of honeycomb.

Nettles, Alan T.↗

Clean Electrical-Discharge Machining Of Delicate Honeycomb

Precise recesses in fragile metal honeycomb blocks formed in special electrical-discharge machining process. Special tooling used, and recesses bored with workpiece in nonstandard alignment. Cutting electrode advances into workpiece along x axis to form pocket of rectangular cross section. Deionized water flows from fitting, along honeycomb tubes of workpiece, to electrode/workpiece interface.

Johnson, Clarence S.↗

Friction-factor data for flat-plate tests of smooth and honeycomb surfaces

Friction factors for honeycomb surfaces were measured with a flat plate tester. The flat plate test apparatus was described and a method was discussed for determining the friction factor experimentally. The friction factor model was developed for the flat plate test based on the Fanno Line Flow. The comparisons of the friction factor were plotted for smooth surfaces and six-honeycomb surfaces with three-clearances, 6.9 bar to 17.9 bar range of inlet pressures, and 5,000 to 100,000 range of the Reynolds number. The optimum geometries for the maximum friction factor were found as a function of cell width to cell depth and cell width to clearance ratios.

Ha, T. W.↗

Seal Leakages for Honeycomb or Smooth Configurations

Three dimensional-CFD simulations were attempted to analyze the flow field in a honeycomb flat plate tester. This discussion reviews some of the numerical difficulties and relations, including those relating the honeycombs to labyrinth throttles and the consistency of selected seal and tester data sets.

Athavale, Mahesh M.↗

Elevated-Temperature Tests Under Static and Aerodynamic Conditions on Honeycomb-Core Sandwich Panels

Stainless-steel honeycomb-core sandwich panels which differed primarily in skin thicknesses were tested at elevated temperatures under static and aerodynamic conditions. The results of these tests were evaluated to determine the insulating effectiveness and structural integrity of the panels. The static radiant-heating tests were performed in front of a quartz-tube radiant heater at panel skin temperatures up to 1,5000 F. The aerodynamic tests were made in a Mach 1.4 heated blowdown wind tunnel. The tunnel temperature was augmented by additional heat supplied by a radiant heater which raised the panel surface temperature above 8000 F during air flow. Static radiant-heating tests of 2 minutes duration showed that all the panels protected the load-carrying structure about equally well. Thin-skin panels showed an advantage for this short-time test over thick-skin panels from a standpoint of weight against insulation. Permanent inelastic strains in the form of local buckles over each cell of the honeycomb core caused an increase in surface roughness. During the aero- dynamic tests all of the panels survived with little or no damage, and panel flutter did not occur.

Groen, Joseph M.↗

Thermographic Inspection of Metallic Honeycomb Sandwich Structures

The X-33/VentureStar has a Thermal Protection System (TPS) consisting mainly of brazed metallic honeycomb sandwich structures. Inspection of these structures is changing as a result of the extremely thin (less than 200 microns) skins, the small critical defect size (less than 2 mm long by 100 microns wide) and the large number (more than 1000) of parts to be inspected. Pulsed Infrared Thermography has been determined to be the most appropriate inspection method for manufacturing inspection based on performance comparison with other methods, cost, schedule and other factors. The results of the assessment of the different methods will be summarized and data on the performance of the final production inspection system will be given. Finite difference thermal methods have been used to model the whole inspection process. Details of correlation between the models and experimental data will be given and data on the use of pulsed infrared thermography on other metallic honeycomb sandwich structures will be given.

Taylor, John O.↗

Vibroacoustic Model Validation for a Curved Honeycomb Composite Panel

Finite element and boundary element models are developed to investigate the vibroacoustic response of a curved honeycomb composite sidewall panel. Results from vibroacoustic tests conducted in the NASA Langley Structural Acoustic Loads and Transmission facility are used to validate the numerical predictions. The sidewall panel is constructed from a flexible honeycomb core sandwiched between carbon fiber reinforced composite laminate face sheets. This type of construction is being used in the development of an all-composite aircraft fuselage. In contrast to conventional rib-stiffened aircraft fuselage structures, the composite panel has nominally uniform thickness resulting in a uniform distribution of mass and stiffness. Due to differences in the mass and stiffness distribution, the noise transmission mechanisms for the composite panel are expected to be substantially different from those of a conventional rib-stiffened structure. The development of accurate vibroacoustic models will aide in the understanding of the dominant noise transmission mechanisms and enable optimization studies to be performed that will determine the most beneficial noise control treatments. Finite element and boundary element models of the sidewall panel are described. Vibroacoustic response predictions are presented for forced vibration input and the results are compared with experimental data.

Buehrle, Ralph D.↗

Mode I Toughness Measurements of Core/Facesheet Bonds in Honeycomb Sandwich Structures

Composite sandwich structures will be used in many future applications in aerospace, marine and offshore industries due to the fact that the strength and stiffness to mass ratios surpass any other structural type. Sandwich structure also offers advantages over traditional stiffened panels such as ease of manufacturing and repair. During the last three decades, sandwich structure has been used extensively for secondary structure in aircraft (fuselage floors, rudders and radome structure). Sandwich structure is also used as primary structure in rotorcraft, the most common example being the trailing edge of rotor blades. As with other types of composite construction, sandwich structure exhibits several types of failure mode such as facesheet wrinkling, core crushing and sandwich buckling. Facesheet/core debonding has also been observed in the marine and aerospace industry. During this failure mode, peel stresses applied to an existing facesheet/core debond or an interface low in toughness, results in the facesheet being peeled from the core material, possibly leading to a significant loss in structural integrity of the sandwich panel. In an incident during a test on a liquid hydrogen fuel tank of the X-33 prototype vehicle, the outer graphite/epoxy facesheet and honeycomb core became debonded from the inner facesheet along significant areas, leading to failure of the tank. As a consequence of the accident; significant efforts were made to characterize the toughness of the facesheet/core bond. Currently, the only standardized method available for assessing the quality of the facesheet/core interface is the climbing drum peel test (ASTM D1781). During this test a sandwich beam is removed from a panel and the lip of one of the facesheets is attached to a drum, as shown in Fig. 1. The drum is then rotated along the sandwich beam, causing the facesheet to peel from the core. This method has two major drawbacks. First, it is not possible to obtain quantitative fracture data from the test and so the results can only be used in a qualitative manner. Second, only sandwich structure with thin facesheets can be tested (to facilitate wrapping of the facesheet around the climbing drum). In recognition of the need for a more quantitative facesheet/core fracture test, several workers have devised experimental techniques for characterizing the toughness of the facesheet/core interface. In all of these cases, the tests are designed to yield a mode I-dominated fracture toughness of the facesheet/core interface in a manner similar to that used to determine mode I fracture toughness of composite laminates. In the current work, a modified double cantilever beam is used to measure the mode I-dominated fracture toughness of the interface in a sandwich consisting of glass/phenolic honeycomb core reinforced with graphite epoxy facesheets. Two specimen configurations were tested as shown in Fig 2. The first configuration consisted of reinforcing the facesheets with aluminum blocks (Fig. 2a). In the second configuration unreinforced specimens were tested (Fig. 2b). Climbing drum peel tests were also conducted to compare the fracture behavior observed between this test and the modified double cantilever beam. This paper outlines the test procedures and data reduction strategies used to compute fracture toughness values from the tests. The effect of specimen reinforcement on fracture toughness of the facesheet/core interface is discussed.

Nettles, Alan T.↗