Search NASA⌕ Search

SEARCH · Search NASA

Results for “He-Ne”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

123 records · Page 7

Mapping crystal defects with a digital scanning ultramicroscope

A computer controlled scanning ultramicroscope has been built to assist in the characterization of transparent crystals. The device measures the scattering of a focused He-Ne laser beam by crystalline defects. As an XYZ translation table moves the crystal under the ultramicroscope, the scattered light is measured by a photodetector whose output is digitized and recorded. From this data, contour maps or three dimensional perspective plots of the scattering regions of the crystal can be generated to assist in finding patterns of defects which might be correlated with perturbations in the growth process. The verified resolution of the present instrument is about 1 micrometer, which is limited by the minimum step of the stepper-motor driven translation stages, optical diffraction effects and the sensitivity of the detector at the laser light frequency. The instrument was used to build a database of defects patterns in commercial laboratory grown triglycine sulphate (TGS) crystals, and to map defects in a TGS crystal grown from aqueous solution during the flight of Spacelab 3. This crystal shows indications of a reduction both in the generation of defects at the seed-new growth interface and in their propagation into the new crystal.

Springer, J. M.↗

Micro-displacement fiber sensor using two-frequency interferometry

A He-Ne Zeeman laser has been utilized as a two-frequency light source in a Michelson-type micro-displacement fiber sensor. A polarization maintaining fiber has been installed in the sensing arm, which facilitates flexibility and allows the sensing region to be remotely located. This fiber sensing arm is arranged to replace a quarterwave plate component. The fiber sensor system has a resolution of half a micrometer.

Tedjojuwono, Ken K.↗

Stress Tuning of Laser Crystals

The topic of stress tunable laser crystals is addressed in this study with the purpose of determining the piezo-optic coefficients of a new laser material. This data was collected using a quadruple pass birefringence technique because of its high degree of sensitivity relative to the other methods examined including fringe shift analysis using a Mach-Zender interferometer. A green He-Ne laser was passed through a light chopper and Glan-Thompson prism before entering a crystal of Erbium doped Yttrium Aluminum Garnet (Er:YAG) (used in order to validate the experimental technique). The Er:YAG crystal is mounted in a press mechanism and the laser is quadruple passed through test specimen before being returned through the prism and the orthogonally polarized portion of the beam measured with a optical sensor. At a later stage, the Er:YAG crystal was replaced with a new crystal in order to determine the piezo-optic coefficients of this uncharacterized material. The applied load was monitored with the use of a 50 lb. load cell placed in line with the press. Light transmission readings were taken using a lock-in amplifier while load cell measurements were taken with a voltmeter from a 5 volt, 0.5 amp power supply. Despite the fact that an effective crystal press damping system was developed, size limitations precluded the use of the complete system. For this reason, data points were taken only once per full turn so as to minimize the effect of non uniform load application on the collected data. Good correlation was found in the transmission data between the experimentally determined Er:YAG and the previously known peizo-optic constants of non-doped crystal with which it was compared. The variation which was found between the two could be accounted for by the aforementioned presence of Erbium in the experimental sample (for which exact empirical data was not known). The same test procedure was then carried out on a Yttrium Gallium Aluminum garnet (YGAG) for the purpose of establishing values of its unknown piezo-optic constant tensor using experimentally collected transmission data. Significant variation between the piezo-optic constants of YAG and YGAG crystals was found however, the excellent data correlation of separate experimental runs carried out on the YGAG sample demonstrates the validity of these results. The data collected during the stressing of the YGAG was of high quality, however the amount of data collected was somewhat limited by a fracture of YGAG specimen which undoubted altered the crystalline lattice structure and hence precluded any further testing.

Carty, Atherton A.↗

Characterization of a Fabry - Perot - Based electrooptic Modulator

An electrooptic modulator using a thin slice of LiNbO3 within the cavity of a Fabry-Perot interferometer is designed and fabricated. The modulator is operated with 633 nm light from a He-Ne laser. Results related to characterization of this modulator are presented.

Banks, C.↗

Optical Sensors Based on Single on Arm Thin Film Waveguide Interferometer

Single-arm dual-mode optical waveguide interferometer utilizes interference between two modes of different order. Sensing effect results from the change in propagation conditions of the modes caused by the environment. The waveguide is made as an open asymmetric structure containing a dye-doped polymer film onto a quartz substrate. It is more sensitive to the change of environment than its conventional polarimetric analog using orthogonal modes (TE and TM) of the same order. The sensor still preserves the option of operating in polarimetric regime using a variety of mode combinations such as TE(sub 0)/TM(sub 0) (conventional) TE(sub 0)/TM(sub 1), TE(sub 1)/TM(sub 0), or TE(sub 1)/TM(sub 1) but can also work in nonpolarimetric regime using combinations TE(sub 0)/TE(sub 1) or TM(sub 0)/TM(sub 1). Utilization of different mode combinations simultaneously makes the device more versatile. Application of the sensor to gas sensing is based on doping polymer film with an organic indicator dye targeting a particular gaseous reagent. Change of the optical absorption spectrum of the dye caused by the gaseous pollutant results in change of the reactive index of the dye-doped polymer film that can be detected by the sensor. As indicator dyes we utilize Bromocresol Purple doped into polymer poly(methyl) methacrylate that is sensitive to small concentrations of ammonia. The indicator dye demonstrated an irreversible increase in optical absorption near the peak at 350 nm being exposed to 5% ammonia in pure nitrogen at 600 Torr. The dye also showed reversible growth of the absorption peak near 600 nm after exposure to a vapor of standard medical ammonia spirit (65% alcohol). We have built a breadboard prototype of the sensor with He-Ne laser as a light source and with a single mode fiber input and a multimode fiber output. The prototype showed a sensitivity to temperature change of the order of 2 C per 2pi phase shift. The sensitivity of the sensor to the presence of dTy ammonia is not less than 300 ppm per 2pi phase shift. The proposed sensor can be used as a robust stand-alone instrument for continuous environment pollution monitoring.

Sarkisov, S. S.↗

Characterization of a Structural Transformation of Carbon Nanotube Materials by Raman Spectroscopy

Raman spectra of carbon nanotubes and carbon microstructure materials synthesized on Si substrates by pulsed laser vaporization have been measured in the range of 50/cm to 4500/cm with the excitation of He-Ne laser. It is found that the formation of nanotubes depends strongly on the growth temperatures and high quality multi-wall and single-wall nanotubes were produced at 700 and 990 C, respectively. The Raman spectra of one sample grown at 700 C were found to be dependent on the excitation intensity. The spectra of the sample suggest that the structure is similar to that of multi-wall nanotubes at low excitation intensity (2.5 kW/sq cm) and it converts to the structure of single-wall nanotubes at higher intensity (25 kW/sq cm). Measurements taken while cycling the light intensity indicate a reversible structural transition.

Cui, Y.↗

Optical Sensors Based on Single Arm Thin Film Waveguide Interferometer

Single-arm double-mode double-order optical waveguide interferometer utilizes interference between two propagating modes of different orders. Sensing effect results from the change in propagation conditions of the modes caused by the environment. The waveguide is made as an open asymmetric slab structure containing a dye-doped polymer film onto a fused quartz substrate. It is more sensitive to the change of environment than its conventional polarimetric analog using orthogonal modes (TE and TM) of the same order. The sensor still preserves the option of operating in polarimetric regime using a variety of mode combinations such as TE(sub 0)/TM(sub 0) (conventional), TE(sub 0)/TM(sub 1), TE(sub 1)/TM(sub 0), or TE(sub 1)/TM(sub 1) but can also work in nonpolarimetric regime using combinations TE(sub 0)/TM(sub 1) or TE(sub 0)/TM(sub 1). Utilization of different mode combinations simultaneously makes the device more versatile. Application of the sensor to gas sensing is based on doping polymer film with an organic indicator dye sensitive to a particular gas. Change of optical absorption spectrum of the dye caused by the gaseous pollutant results change of the reactive index of the dye-doped polymer film that can be detected by the sensor. As an indicator dyes, we utilize Bromocresol Purple doped into polymer poly(methyl) methacrylate, which shows a reversible growth of the absorption peak neat 600 nm after exposure to wet ammonia. We have built a breadboard prototype of the sensor with He-Ne laser as a light source and with a single mode fiber input and a multimode fiber output. The prototype showed sensitivity to temperature change of the order of 2 C per one full oscillation of the signal. The sensitivity of the sensor to the presence of wet ammonia is 200 ppm per one full oscillation of the signal. The further improvements include switching to a longer wavelength laser source (750-nm semiconductor laser), substitution of poly(methyl) methacrylate with hydrophilic high-temperature polyimide, and increase the doping rate of indicator dye. All these improvements are expected to bring sensitivity to 10 ppm of ammonia per one full oscillation of signal independent on the humidity of ambient air. The proposed sensor can be used as a robust and inexpensive stand-alone instrument for continuous environment pollution monitoring.

Sarkisov, S. S.↗

Measurement of the Specific Refractivities of CF4 and C2F6

In order to relate the measured fringe shift of an interferometer to density, the relation between density rho and refractive index n must be known. For gases where the refractive index is close to unity, this relation between density and refractive index is very closely approximated by (n - 1) = K rho where K is the specific refractivity, or the Gladstone-Dale constant. The specific refractivity, which is weakly dependent on wavelength and temperature, is readily available for a number of common test gases such as N2 and air. For more unique test gases such as CF4 and C2F6 for which refractive index data at optical wavelengths is not readily available, the constants can be estimated from the atomic refractivities of carbon and fluorine. In order to verify this estimation, a two-beam interferometer was used to experimentally determine the specific refractivities of CF4 and C2F6. This data was required for holographic interferometric measurements made at the Langley Hypersonic CF4 Tunnel. A Twyman-Green interferometer with a He-Ne laser light source of vacuum wavelength lambda equal to 633 nm was used to measure the constants. One beam of the two-beam interferometer passed through an optical cell of known inside length l which could be evacuated and slowly filled with the test gas to a density of 7.2 kg/cu m for CF4 or 5.7 kg/cu m for C2F6. If the refractive index (and hence density) is constant along the optical path through the cell, the fringe shift M and density change Delta rho are related M = 2Kl Delta rho/lambda for the double pass interferometer. Thus K can be determined by measuring the fringe shift as the density is changed. The output of a photodiode used to detect the fringe shift was recorded on a strip chart recorder. The rate of pressure increase of the test gas in the cell was controlled such that the fringes shifted at a rate of 0.5 to 1 fringe per sec. The pressure in the test cell was measured with a high accuracy quartz crystal pressure transducer and recorded approximately every 20 fringe peaks. The temperature of the cell was measured with a thermocouple and recorded at the start, midpoint, and end of each test.

Burner, A. W.↗

Remote, Noncontact Strain Sensing by Laser Diffraction Developed

A system was developed at the NASA Glenn Research Center for continually monitoring, in real time, the in-plane strain tensor in opaque solids during high-temperature, long-term mechanical testing. The simple, noncontacting, strain-sensing methodology should also be suitable for measurement in hostile environments. This procedure has obvious advantages over traditional, mechanical, contacting techniques, and it is easier to interpret than moir and speckle interferometric approaches. A two-dimensional metallic grid of micrometer dimensions is applied to a metallographically prepared gauge section on the surface of a tensile test specimen by a standard photolithographic process. The grid on the fixtured specimen is interrogated by an He-Ne laser, and the resulting diffraction pattern is projected backwards onto a translucent screen. A charge-coupled device (CCD) camera is used to image the first-order diffraction peaks from the translucent screen. A schematic representation of the system is shown in the figure.

Freedman, Marc R.↗

New Optical Constants for Amorphous and Crystalline H2O-ice and H2O-mixtures.

We will present the products of new laboratory measurements of ices relevant to Trans-Neptunian Objects. We have calculated the real and imaginary indices of refraction for amorphous and crystalline H2O-ice and also H2O-rich ices containing other molecular species. We create ice samples by condensing gases onto a cold substrate. We measure the thickness of the sample by reflecting a He-Ne laser off of the sample and counting interference fringes as it grows. We then collect transmission spectra of the samples in the wavelength range from 0.7-22 micrometers. Using the thickness and the transmission spectra of the ice we calculate the imaginary part of the index of refraction. We then use a Kramers-Kronig calculation to calculate the real part of the index of refraction (Berland et al. 1994; Hudgins et al. 1993). These optical constants can then be used to create model spectra for comparison to spectra from Solar System objects, including TNOs. We will summarize the difference between the amorphous and crystalline H2O-ice spectra. These changes include weakening of features and shifting of features to shorter wavelength. One important result is that the 2 pm feature is stronger in amorphous H2O ice than it is in crystalline H2O-ice. We will also discuss the changes seen when H2O is mixed with other components, including CO2, CH4, HCN, and NH3 (Bernstein et al. 2005; Bernstein et al. 2006).

Mastrapa, Rachel↗

New Optical Constants for Amorphous and Crystalline H2O-ice

We have used the infrared spectra of laboratory ices to calculate the real and imaginary indices of refraction for amorphous and crystalline H2O-ice. We create H2O-ice samples in vacuum (approx. 10(exp ^-8)Torr). We measure the thickness of the sample by reflecting a He-Ne laser off of the sample and counting interference fringes as it grows and then collect transmission spectra of the samples in the wavelength range 1.25-22 micrometers. Using the ice thickness and transmission spectrum we calculate the imaginary part of the index of refraction. A Kramers-Kronig calculation is then used to calculate the real part of the index of refraction (Berland et al. 1994; Hudgins et al. 1993). These optical constants can be used to create model spectra for comparison to spectra from Solar System objects. We will summarize the differences between the amorphous and crystalline H2O-ice spectra. These include weakening of features and shifting of features to shorter wavelength in amorphous H,O-ice spectra. We will also discuss methods of using band area ratios to quickly estimate the fraction of amorphous to crystalline H2O-ice. We acknowledge financial support from the NASA Origins of the Solar System Program, the NASA Planetary Geology and Geophysics Program, and the NASA Postdoctoral Program.

Mastrapa, Rachel↗

How Did I Get Here?

What country was responsible for much of the early work in laser altimetry, who was the first scientist to look at a vegetation profile generated by a laser, who first related laser ranges to forest structure? The purpose of this paper is to look back 3+ decades ago when forestry lidar was in its formative years and to give credit to those who first thought to employ a laser to measure the Earth's surface. As with much scientific research, advances were often made independently and concurrently in a number of countries. Functioning lasers were first demonstrated in 1960 in the USA and in 1961 in the USSR, but research into the use of lasers as forest measurement tools did not begin for another IS years. Initially, with respect to Earth resources, lasers were employed to measure sea ice surface roughness, to make near-shore bathymetric measurements, to penetrate forests to make detailed topographic measurements, and to fluoresce oceanic phytoplankton for surface current studies. Some of these early studies noted that forest profiles were evident but in fact added noise to topographic retrievals. Trees became the signal rather than noise in 1976 when researchers in the Canadian Forest Service went to an IUFRO conference in Oslo and reported on efforts to better estimate timber volume in tropical forests. They employed large-scale airphotos (1:500 up to 1:4000) to measure the top of the tropical canopy, an avionic radar to measure the location of the ground beneath the canopy, and a barometric sensor to record aircraft/radar height above a datum (e.g., sea level). Their radar did not work well in dense vegetation and mentioned in passing that a laser altimeter had worked well in Canadian forests. But in a report 2 years later they reported that, on a study area in Costa Rica, the radar ground line was much improved and no mention is made of a lidar altimeter. In the USSR in 1977, Russian researchers felled a birch and a spruce, aimed a helium-neon, 0.63 micron laser with a spot size of approx 25mm, at the horizontal trees, produced a profilograph, compared it to tape measurements, and concluded that, with increased power, such a laser could be mounted on an aircraft to remotely measure forest canopies. In 1979, they mounted their He-Ne laser on an AN-2 biplane and acquired their fIrSt airborne profiles. Scientists with TRANARG, a mapping/surveying company in Caracas, Venezuela, reported on 1976 flights employing a helium-neon lidar to collect over 11,000 km of lidar profiles spaced 1.5 km apart in order to construct a topographic map to help site a new reservoir. They noted 35-40 m median canopy heights with emergents up to 55 m in their profiles. These studies and others that utilize these height and canopy density metrics for forest mensuration are reviewed in this glance backwards at the history of forestry lidar.

Nelson, Ross↗

Experimental Estimation of CLASP Spatial Resolution: Results of the Instrument's Optical Alignment

The Chromospheric Lyman-Alpha SpectroPolarimeter (CLASP) is a sounding-rocket experiment currently being built at the National Astronomical Observatory of Japan. This instrument aims to probe for the first time the magnetic field strength and orientation in the solar upper-chromosphere and lower-transition region. CLASP will measure the polarization of the Lyman-Alpha line (121.6nm) with an unprecedented accuracy, and derive the magnetic field information through the Hanle effect. Although polarization accuracy and spectral resolution are crucial for the Hanle effect detection, spatial resolution is also important to get reliable context image via the slit-jaw camera. As spatial resolution is directly related with the alignment of optics, it is also a good way of ensuring the alignment of the instrument to meet the scientific requirement. This poster will detail the experiments carried out to align CLASP's optics (telescope and spectrograph), as both part of the instrument were aligned separately. The telescope was aligned in double-pass mode, and a laser interferometer (He-Ne) was used to measure the telescope's wavefront error (WFE). The secondary mirror tilt and position were adjusted to remove comas and defocus aberrations from the WFE. Effect of gravity on the WFE measurement was estimated and the final WFE derived in zero-g condition for CLASP telescope will be presented. In addition, an estimation of the spot shape and size derived from the final WFE will also be shown. The spectrograph was aligned with a custom procedure: because Ly-light is absorbed by air, the spectrograph's off-axis parabolic mirrors were aligned in Visible Light (VL) using a custom-made VL grating instead of the flight Ly- grating. Results of the alignment in Visible Light will be shown and the spot shape recorded with CCDs at various position along the slit will be displayed. Results from both alignment experiment will be compared to the design requirement, and will be combined in order to estimate CLASP spatial resolution after its alignment in visible light.

spatial resolution↗

CO Chondrite Parent Body Processing as Recorded by Noble Gases

**Introduction:** CO carbonaceous chondrites are among the most primitive meteorites, of which some experienced mild degrees of thermal alteration (up to 500 °C) in their parent asteroid. Previous studies on aqueously altered CM, CY and CR chondrites have shown that the noble gases preserved in those meteorites can be used to assess the extent of parent body processing. This is mostly due to an Ar-rich carrier phase being susceptible to aqueous alteration. In this study, we follow up on these findings by investigating the effects of mild thermal alteration on the noble gas content of CO chondrites. They are subclassified from petrologic subtype 3.0 (e.g., Yamato-81025) to 3.8 (e.g., Isna) according to the degree of thermal alteration experienced. Understanding these effects does not only help to distinguish the most primitive samples from the severely altered ones, but also adds to the picture of the primordial volatile composition and distribution, as preserved in the most primitive material which accreted from the solar nebula at different heliocentric distances. Additionally, we search for pairing among samples, as part of an ongoing survey of Antarctic CO chondrites. **Experimental:** Noble gas measurements were conducted on aliquots of ~20-25 mg from 16 different samples of varying petrologic subtype from 3.0 to 3.8. The gas extraction occurred in one temperature step at ~1700 °C, followed by separation into three fractions, He-Ne, Ar, and Kr-Xe, measured successively in a custom-built mass spectrometer. For each sample, complete gas extraction was verified by a re-extraction step at ~1750 °C. Details on the sample preparation and measurement protocols can be found in. **Results and Discussion:** In most cases, the gas concentrations for all five noble gases decrease with increasing petrologic subtype, and the trend is most pronounced for Ne. An exception is e.g. CO3.0 Colony, which is strongly terrestrially weathered. CO3.8 Isna shows an unusually short expo-sure time to cosmic rays (~0.15 Ma), which may be explained by a direct injection into a mean orbital resonance shortly after collision. The currently ill-defined Ar-rich carrier phase, found only in the least aqueously altered CM and CR samples, is still abundantly present in the predominately anhydrous CO chondrites, indicating that this component is less susceptible to moderately elevated temperatures. No CO chondrites examined so far contain solar wind, supporting the hypothesis that CO chondrites originate from the asteroidal interior. It thus remains enigmatic which material could account for the surface layer.

Noble gas↗