Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

High frequency drift instabilities in a dusty plasma

High frequency drift instabilities with omega(sub ce) much greater than omega which is greater than omega(sub ci) are investigated in a dusty magnetized plasma in which locally there is an electron density gradient which is opposite in sign to a dust density gradient. Two different equilibria are considered, characterized by rho(sub d) greater than L(sub d) and less than L(sub d), where rho(sub d) is the dust gyroradius and L(sub nd) is the dust density scale length. Possible application to Saturn's F-ring is discussed.

Rosenberg, M.↗

Bolometric detectors for the high frequency instrument on the Planck surveyor

The High Frequency Instrument (HFI) on Planck will obtain all-sky images of the Cosmic Microwave Background (CMB) and other astrophysical sources of emission with resolution of 9 arcniin at 100 GHz, 7 arcmin at 143 GHz and 5 arcniin at 217, 353, 545 and 857 GHz. The HFI focal plane will contain 48 silicon nitride micromesh bolometric detectors operating from a 100 mK heat sink. Four detectors in each of the 6 bands will detect the sum of the power in both linear polarizations. An additional 4 pair of detectors will provide sensitivity to linear polarization of emission at 143, 217 and 353 GHz. We report on the development of these detectors, which are being produced at the JPL Micro Devices Laboratory, packaged at JPL Electronics Packaging, characterized at 100 mK before delivery to our HFI consortium partners at the UWCC, UK.

Planck CMB bolometer↗

A high frequency silicon pressure sensor

Theoretical and design considerations as well as fabrication and experimental work involved in the development of high-frequency silicon pressure sensors with an ultra-small diaphragm are discussed. A sensor is presented with a rectangular diaphragm of 0.0127 cm x 0.0254 cm x 1.06 micron; the sensor has a natural frequency of 625 kHz and a sensitivity of 0.82 mv/v-psi. High-frequency results from shock tube testing and low-frequency (less than 50 kHz) comparison with microphones are given.

Kahng, S. K.↗

High Frequency Plasma Generators for Ion Thrusters

The results of a one year program to experimentally adapt two new types of high frequency plasma generators to Argon ion thrusters and to analytically study a third high frequency source concept are presented. Conventional 30 cm two grid ion extraction was utilized or proposed for all three sources. The two plasma generating methods selected for experimental study were a radio frequency induction (RFI) source, operating at about 1 MHz, and an electron cyclotron heated (ECH) plasma source operating at about 5 GHz. Both sources utilize multi-linecusp permanent magnet configurations for plasma confinement. The plasma characteristics, plasma loading of the rf antenna, and the rf frequency dependence of source efficiency and antenna circuit efficiency are described for the RFI Multi-cusp source. In a series of tests of this source at Lewis Research Center, minimum discharge losses of 220+/-10 eV/ion were obtained with propellant utilization of .45 at a beam current of 3 amperes. Possible improvement modifications are discussed.

Divergilio, W. F.↗

A search for the effect of a high frequency spark on boundary-layer transition at Mach 8.5

An experimental investigation of the use of a high frequency spark to promote early boundary layer transition on a wind tunnel model was conducted at a Mach number of 8.5. Test variables included four electrode configurations, a frequency range from 10 kHz to 50 kHz, and various power inputs to the spark. The general conclusion obtained from this investigation is that over the parameter range, the high frequency spark is ineffective in inducing early transition at the test Mach number.

Anders, J. B.↗

Low Frequency High Amplitude Temperature Oscillations in Loop Heat Pipe Operation

This paper presents a theory that explains low frequency, high amplitude temperature oscillations in loop heat pipe (LHP) operation. Oscillations of the CC temperature with amplitudes on the order of tens of degrees Kelvin and periods on the order of hours have been observed in some LHPs during ambient testing. There are presently no satisfactory explanations for such a phenomenon in the literature. It is well-known that the operating temperature of an LHP with a single evaporator is governed by the compensation chamber (CC) temperature, which in turn is a function of the evaporator heat load, sink temperature, and ambient temperature. As the operating condition changes, the CC temperature will change during the transient but eventually reach a new steady temperature. Under certain conditions, however, the LHP never really reaches a true steady state, but instead displays an oscillatory behavior. The proposed new theory describes why low frequency, high amplitude oscillations may occur when the LHP has a low evaporator power, a low heat sink temperature (below ambient temperature), and a large thermal mass attached to the evaporator. When this condition prevails, there are some complex interactions between the CC, condenser, thermal mass and ambient. The temperature oscillation is a result of the large movement of the vapor front inside the condenser, which is caused by a change in the net evaporator power modulated by the large thermal mass through its interaction with the sink and CC. The theory agrees very well with previously published test data. Effects of various parameters on the amplitude and frequency of the temperature oscillation are also discussed.

Ku, Jentung↗

High-Frequency Testing of Composite Fan Vanes With Erosion-Resistant Coating Conducted

The mechanical integrity of hard, erosion-resistant coatings were tested using the Structural Dynamics Laboratory at the NASA Glenn Research Center. Under the guidance of Structural Mechanics and Dynamics Branch personnel, fixturing and test procedures were developed at Glenn to simulate engine vibratory conditions on coated polymer-matrix- composite bypass vanes using a slip table in the Structural Dynamics Laboratory. Results from the high-frequency mechanical bench testing, along with concurrent erosion testing of coupons and vanes, provided sufficient confidence to engine-endurance test similarly coated vane segments. The knowledge gained from this program will be applied to the development of oxidation- and erosion-resistant coatings for polymer matrix composite blades and vanes in future advanced turbine engines. Fan bypass vanes from the AE3007 (Rolls Royce America, Indianapolis, IN) gas turbine engine were coated by Engelhard (Windsor, CT) with compliant bond coatings and hard ceramic coatings. The coatings were developed collaboratively by Glenn and Allison Advanced Development Corporation (AADC)/Rolls Royce America through research sponsored by the High-Temperature Engine Materials Technology Project (HITEMP) and the Higher Operating Temperature Propulsion Components (HOTPC) project. High-cycle fatigue was performed through high-frequency vibratory testing on a shaker table. Vane resonant frequency modes were surveyed from 50 to 3000 Hz at input loads from 1g to 55g on both uncoated production vanes and vanes with the erosion-resistant coating. Vanes were instrumented with both lightweight accelerometers and strain gauges to establish resonance, mode shape, and strain amplitudes. Two high-frequency dwell conditions were chosen to excite two strain levels: one approaching the vane's maximum allowable design strain and another near the expected maximum strain during engine operation. Six specimens were tested per dwell condition. Pretest and posttest inspections were performed optically at up to 60 magnification and using a fluorescent-dye penetrant. Accumulation of 10 million cycles at a strain amplitude of two to three times that expected in the engine (approximately 670 Hz and 20g) led to the development of multiple cracks in the coating that were only detectable using fluorescent-dye penetrant inspection. Cracks were prevalent on the trailing edge and on the convex side of the midsection. No cracking or spalling was evident using standard optical inspection at up to 60 magnification. Further inspection may reveal whether these fine cracks penetrated the coating or were strictly on the surface. The dwell condition that simulated actual engine conditions produced no obvious surface flaws even after up to 80 million cycles had been accumulated at strain amplitudes produced at approximately 1500 Hz and 45g.

Bowman, Cheryl L.↗

Condenser Microphone Protective Grid Correction for High Frequency Measurements

Use of a protective grid on small diameter microphones can prolong the lifetime of the unit, but the high frequency effects can complicate data interpretation. Analytical methods have been developed to correct for the grid effect at high frequencies. Specifically, the analysis pertains to quantifying the microphone protective grid response characteristics in the acoustic near field of a rocket plume noise source. A frequency response function computation using two microphones will be explained. Experimental and instrumentation setup details will be provided. The resulting frequency response function for a B&K 4944 condenser microphone protective grid will be presented, along with associated uncertainties

Lee, Erik↗

Thermal-distortion analysis of an antenna strongback for geostationary high-frequency microwave applications

The global change technology initiative calls for a geostationary platform for Earth science monitoring. One of the major science instruments is the high frequency microwave sounder (HFMS) which uses a large diameter, high resolution, high frequency microwave antenna. This antenna's size and required accuracy dictates the need for a segmented reflector. On-orbit disturbances may be a significant factor in its design. A study was performed to examine the effects of the geosynchronous thermal environment on the performance of the strongback structure for a proposed antenna concept for this application. The study included definition of the strongback and a corresponding numerical model to be used in the thermal and structural analyses definition of the thermal environment, determination of structural element temperature throughout potential orbits, estimation of resulting thermal distortions, and assessment of the structure's capability to meet surface accuracy requirements. Analyses show that shadows produced by the antenna reflector surface play a major role in increasing thermal distortions. Through customization of surface coating and element expansion characteristics, the segmented reflector concept can meet the tight surface accuracy requirements.

Farmer, Jeffrey T.↗

Overview of the Medium and High Frequency Telescopes of the LiteBIRD Satellite Mission

LiteBIRD is a JAXA-led Strategic Large-Class mission designed to search for the existence of the primordial gravitational waves produced during the inflationary phase of the Universe, through the measurements of their imprint onto the polarization of the cosmic microwave background (CMB). These measurements, requiring unprecedented sensitivity, will be performed over the full sky, at large angular scales, and over 15 frequency bands from 34 GHz to 448 GHz. The LiteBIRD instruments consist of three telescopes, namely the Low-, Medium- and High-Frequency Telescope (respectively LFT, MFT and HFT). We present in this paper an overview of the design of the Medium-Frequency Telescope (89–224 GHz) and the High-Frequency Telescope (166–448 GHz), the so-called MHFT, under European responsibility, which are two cryogenic refractive telescopes cooled down to 5 K. They include a continuous rotating half-wave plate as the first optical element, two high-density polyethylene (HDPE) lenses and more than three thousand transition-edge sensor (TES) detectors cooled to 100 mK. We provide an overview of the concept design and the remaining specific challenges that we have to face in order to achieve the scientific goals of LiteBIRD.

LiteBIRD↗

Ceramic Heat Pipe for Thermal Management of a High Frequency Inductor

As the power density of electric machines and power electronics continues to increase to meet the demands of more electric aircraft, the thermal management of these devices becomes increasingly important. Ideally, the thermal management solution of the device should have high thermal conductivity and be electrically insulating so that it can be directly integrated with the device in question. Technical ceramics are a class of materials that meet these two requirements. Direct liquid cooling by submerging electric components in a dielectric fluid is an alternate option, but adds system complexity and may incur pumping loss. In this work, the thermal management solution for a high frequency inductor is presented. A conventional wicked heat pipe is designed that is made from a solid ceramic case with a sintered ceramic wick. This heat pipe can provide structural support for the core and windings and is electrically insulating, so it does not incur any additional eddy current losses from the high frequency magnetic fields. It does not require additional pumping power, because conventional wicked heat pipes are passive devices. In this paper, the manufacturing process of the ceramic heat pipe is also presented. It is shown that the sintering of large diameter spherical ceramic particles is difficult due to their high specific surface area and low surface free energy. To overcome this difficulty, a flux material was used to initiate liquid phase sintering. The results of the sintering trials show that for the 120 μm diameter α-Al2O3powder selected for the wick, the combination of 1650°C sintering temperature and the addition of 5 wt% talc sintered the porous matrix together sufficiently for use as a heat pipe wic

High-frequency Inductor↗

Ceramic Heat Pipe for Thermal Management of a High Frequency Inductor

As the power density of electric machines and power electronics continues to increase to meet the demands of more electric aircraft, the thermal management of these devices becomes increasingly important. Ideally, the thermal management solution of the device should have high thermal conductivity and be electrically insulating so that it can be directly integrated with the device in question. Technical ceramics are a class of materials that meet these two requirements. Direct liquid cooling by submerging electric components in a dielectric fluid is an alternate option, but adds system complexity and may incur pumping loss. In this work, the thermal management solution for a high frequency inductor is presented. A conventional wicked heat pipe is designed that is made from a solid ceramic case with a sintered ceramic wick. This heat pipe can provide structural support for the core and windings and is electrically insulating, so it does not incur any additional eddy current losses from the high frequency magnetic fields. It does not require additional pumping power, because conventional wicked heat pipes are passive devices. In this paper, the manufacturing process of the ceramic heat pipe is also presented. It is shown that the sintering of large diameter spherical ceramic particles is difficult due to their high specific surface area and low surface free energy. To overcome this difficulty, a flux material was used to initiate liquid phase sintering. The results of the sintering trials show that for the 120 μm diameter α-Al2O3 powder selected for the wick, the combination of 1650°C sintering temperature and the addition of 5 wt% talc sintered the porous matrix together sufficiently for use as a heat pipe wick.

High frequency inductor↗