Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Performance Building Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Interfacial Analysis of Blister Formation in U-10Mo Mini-Plates

A thorough investigation of potential failure mechanisms builds confidence in the performance of monolithic U-10wt%Mo (U-10Mo) fuel plates. The lowenriched uranium (LEU) fuel system is currently undergoing qualification as a high U-density fuel that can be used to convert United States high-performance research reactors from high-enriched uranium (HEU) operation. This will require establishing fuel operational limits such that fission products and a coolable geometry are retained, even during off-normal reactor operation conditions [1]. Such off-normal conditions can subject the fuel plates to temperatures where the internal pressure of precipitated fission gasses result in a permanent deformed, raised area of the cladding, referred to as a blister. These blisters can reduce the local coolability of a fuel plate and can even close coolant channels of a fuel assembly, so blistered plates are considered failed regardless of whether the fuel is truly breached. Historically, a marginto- failure is established through out-of-pile blister threshold testing of irradiated fuel plates. This is accomplished by incrementally heating irradiated fuel plates until blisters are observed. This reveals the temperature threshold that would have resulted in a blister if a plate experienced them at those irradiation conditions [2]. While the blister testing itself reveals the temperatures at which the cladding mechanical integrity was exceeded, a more thorough investigation of the interface evolution in proximity to formed blisters may reveal mechanisms as to the blister formation and retention of fission gases. Previous studies have explored potential underlying mechanisms in historical plates that may have been close to blistering [3]; however, this work is the first exploration of blister tested irradiated plates, fabricated by a commercial vendor—another requirement for qualification of the fuel system [1]. The Mini-plate 1 (MP-1) experiment was the first in a series of irradiation and post-irradiation examination (PIE) campaigns to qualify the U-10Mo monolithic fuel system. It consisted of commercially fabricated 25.4×101.5 mm Al-clad mini-plates with a monolithic U-10Mo foil coated in a Zr diffusion barrier. The primary MP-1 PIE campaign was previously completed. Among the suit of examinations was a blister testing campaign, where plates were incrementally annealed in 25°C increments until blisters were observed or a maximum temperature of 550°C was reached [4]. The previously blistered plates from this campaign were revisited in this work.

25228↗

Power Electronics and Electric Machines for Advanced Aircraft

Power electronics and electric machines are critical components of efficient, high-performance aircraft - from fixed-wing turbine to electric vertical takeoff and landing aircraft and beyond. Improvements to these components create enormous energy efficiencies, enable cost savings, and ensure fail-safe operations. National Renewable Energy Laboratory researchers are developing innovative power electronics, electric motors, integrated electric traction drives, and thermal management systems to build highly efficient, lightweight, ultrareliable powertrains for aircraft.

42 ENGINEERING↗

High Efficiency Heat Pumps Can Pave the Path for Building Decarbonization in Cold Climates: Preprint

Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.

cold climate heat pump↗

Towards Learning-Based Architectures for Sensor Impact Evaluation in Building Controls

Advanced control algorithms for building systems are known to have significant potential in reducing energy consumption while optimizing thermal comfort. The success of such algorithms is critically contingent on several different types of sensor systems, which are in turn, used for continuous monitoring, identification and estimation of several important building states, such as temperatures, humidity, air quality, power consumption and occupancy status. Nonidealities in any of these sensors can lead to significant performance degradation of the control functionalities, and may lead to unwanted sub-optimal building operation. In this paper, we provide a simulation example with a high-fidelity building model, for a particular use-case of advanced optimization-based control in buildings, i.e., occupancy-based controls. We show how imperfections in occupancy sensing can offset performance. Subsequently, we discuss a novel learning-based architecture to efficiently evaluate the impact of sensor nonidealities for building systems, in context of advanced control algorithms.

Bhattacharya, Saptarshi↗

Energy-Efficient and Resilient Infrastructure: Simulation, Validation, and Installation

Advanced, high-performance computing at the National Renewable Energy Laboratory (NREL) has enabled access to vast data resources with cutting-edge software techniques to understand, design, plan for, and maintain energy-efficient and resilient infrastructure. We have focused on cities and airports, but the technology we have developed will easily translate to seaports, inland ports, military installations, or other complex and large-scale energy-intensive systems. We can digitally simulate and explore current and future scenarios to make datadriven decisions for optimizing advanced energy systems, transportation and building operations, infrastructure planning and expansion, and battery storage to guide short- and long-term investments, electrification strategies, and integration of new technologies.

Athena↗

One Step Block-like Copolymers from an Upcycled Monomer Using Ring-Opening Metathesis Polymerization

Block-like copolymers can be readily synthesized in one step using monomers with widely separated reactivity ratios. Here, we show that trans,trans,trans-1,5,9-cyclododecatriene (CDT), produced from polybutadiene via cyclodepolymerization (CDP), undergoes gradient copolymerization via ring-opening metathesis polymerization (ROMP) with a selected norbornene monomer to produce a block-like copolymer that exhibits bulk nanophase separation and excellent thermomechanical performance. These data highlight a new ROMP copolymerization system with a sharp compositional drift and introduce a simple pathway to convert waste plastic into a valuable building block for high-value thermoplastic materials.

block copolymer↗

Surface and bulk two-level-system losses in lithium niobate acoustic resonators

Lithium niobate (LN) is a promising material for building acoustic resonators used in quantum applications, but its performance is limited by poorly understood material defects called two-level systems (TLSs). Here, in this work, we fabricate high-performance acoustic resonators from LN with quality factors up to 6 ×10 7 and use them to separate bulk and surface contributions to TLS loss. By comparing these bulk acoustic wave (BAW) resonators with previous surface-acoustic-wave and phononic-crystal studies, we show that devices with high surface-participation ratios are limited by surface TLSs, while our BAW devices reveal an intrinsic bulk TLS limit. Through systematic surface treatments and microscopy, we demonstrate that BAW resonator performance remains unchanged despite surface modifications, confirming operation in a bulk-limited regime. Here, our work establishes quantitative bounds on both surface and bulk TLS losses in LN within the context of the material growth and fabrication approaches we have pursued, and it provides guidance for future device engineering and materials development.

acoustic wave phenomena↗

Concept Design and Analysis of the Magnet System of the Sustained High Power Density Tokamak Facility

A recent National Academy study recommended a next-step sustained high power density (SHPD) facility for the United States that can be a bridge to a compact fusion pilot plant. A design has been initiated to investigate a possible SHPD non-deuterium-tritium device that builds upon recent low aspect ratio tokamak studies. Here, a 1.2-m device with a 2.4 aspect ratio has been chosen to evaluate physics performance goals within a double-null plasma machine arrangement centered on three component features: high current density toroidal field (TF) and central ohmic heating/poloidal field (PF) coils, liquid metal divertor/first wall systems, and the integration of a limited set of outboard dual-coolant lead lithium test blankets that can be maintained within a vertical maintenance approach.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of Unmanned Aerial Systems for Post-closure Waste Site Maintenance and Surveillance - 20143

The P- and R-Area Reactor buildings, located at SRS near Aiken, SC, were in-situ decommissioned by grouting below-grade portions of the buildings and demolishing some above-grade structures to grade level. Other reactor building structures were left above-grade and sealed to prevent human or animal access. Because the above grade-structures are expected to continue in their present state for hundreds of years, the condition of the building roofs is critical to mitigate rainwater intrusion. For this reason, building roof areas were strengthened with high strength concrete to ensure the long-term integrity of the roof structure. Periodic inspections of the roof structures are required to ensure that the roofs are functioning properly and to identify damage areas. The traditional method of inspecting closed reactor buildings requires the use of a helicopter and photographer to generate photographs and videos for review. This method proved sufficient but lacked the resolution and clarity that is required for a thorough inspection of the building structure. Fortunately, the Savannah River National Laboratory (SRNL) has established a Small Unmanned Aircraft System (sUAS) program using commercially available and custom-built remote-controlled aircraft. EC and ACP contacted the SRNL program to evaluate whether the sUAS technology could be employed for periodic reactor building inspections. The sUAS can fly within a few meters of the reactor buildings and hover, allowing for a more thorough aerial inspection. The initial sUAS inspection of the P-Area Reactor building was completed in February 2018 and at the R-Area Reactor building in August 2018 and were successful in providing higher resolution photos and videos. The sUAS inspections also revealed that vegetation had begun to grow on the roofs that could potentially damage the structure integrity. SRNL partnered with Virginia Polytechnic Institute and State University to build a custom heavy lift sUAS that could be equipped with herbicides to remotely treat the vegetative growth. Herbicides were successfully applied to the R-Area Reactor building roof using the custom sUAS in September 2018. The use of unmanned aircraft systems at SRS to perform aerial inspections and herbicide treatment in otherwise inaccessible areas has proven to be an efficient and cost-effective technology that provides high value, increases knowledge of facility conditions, and provides for early detection of damage. Periodic inspections of the reactor building roofs using sUAS technology are performed safely, efficiently, and at a significant cost and schedule savings while reducing emissions, noise, and fossil fuel use. The use of sUAS equipment for building inspections and herbicide application at SRS is unique within the DOE complex. The goal of SRS is to apply this remote technology to other waste unit operations and maintenance activities in the future. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Interpreting Write Performance of Supercomputer I/O Systems with Regression Models

This work seeks to advance the state of the art in HPC I/O performance analysis and interpretation. In particular, we demonstrate effective techniques to: (1) model output performance in the presence of I/O interference from production loads; (2) build features from write patterns and key parameters of the system architecture and configurations; (3) employ suitable machine learning algorithms to improve model accuracy. We train models with five popular regression algorithms and conduct experiments on two distinct production HPC platforms. We find that the lasso and random forest models predict output performance with high accuracy on both of the target systems. We also explore use of the models to guide adaptation in I/O middleware systems, and show potential for improvements of at least 15% from model-guided adaptation on 70% of samples, and improvements up to 10× on some samples for both of the target systems.

Xie, Bing↗

Building High-Energy Silicon-Containing Batteries Using Off-The-Shelf Materials

The technology of silicon anodes appears to be reaching maturity, with high-energy Si cells already in pilot-scale production. However, the performance of these systems can be difficult to replicate in academic settings, making it challenging to translate research findings into solutions that can be implemented by the battery industry. Part of this difficulty arises from the lack of access to engineered Si particles and anodes, as electrode formulations and the materials themselves have become valuable intellectual property for emerging companies. Here, we summarize the efforts by Argonne’s Cell Analysis, Modeling, and Prototyping (CAMP) Facility in developing Si-based prototypes made entirely from commercially available materials. We describe the many challenges we encountered when testing high-loading electrodes (>5 mAh cm −2 ) and discuss strategies to mitigate them. With the right electrode and electrolyte design, we show that our pouch cells containing ≥ 70 wt% SiO x can achieve 600–1,000 cycles at C/3 and meet projected energy targets of 700 Wh L −1 and 350 Wh kg −1 . These results provide a practical reference for research teams seeking to advance silicon-anode development using accessible materials.

25 ENERGY STORAGE↗

Rapid Annotation of Photosynthetic Systems (RAPS): automated algorithm to generate genome-scale metabolic networks from algal genomes

Algae have mounting potential to serve as platform strains for engineering efforts, but tools for these species lag behind traditional model systems like E. coli and yeast. Metabolic models are one such tool that would enhance our ability to rationally engineer algae but current automated algorithms to build models do not perform well for algal genomes. We introduce a novel software pipeline, Rapid Annotation of Photosynthetic Systems (RAPS), which leverages manual curation efforts of published models to create high quality first draft metabolic networks for new species. We compared models produced by our pipeline to published models and found that these models are able to capture more genes than the published models and are more predictive of experimentally determined growth rate. We used RAPS to automate the creation of 8 first draft metabolic models of new species to enable the further study of metabolism in these species.

09 BIOMASS FUELS↗

Investigating User Experiences with Data Abstractions on High Performance Computing Systems

Scientific exploration generates expanding volumes of data that commonly require High Performance Computing (HPC) systems to facilitate research. HPC systems are complex ecosystems of hardware and software that frequently are not user friendly. The Usable Data Abstractions (UDA) project set out to build usable software for scientific workflows in HPC environments by undertaking multiple rounds of qualitative user research. Qualitative research investigates how individuals accomplish their work and our interview-based study surfaced a variety of insights about the experiences of working in and with HPC ecosystems. This report examines multiple facets to the experiences of scientists and developers using and supporting HPC systems. We discuss how stakeholders grasp the design and configuration of these systems, the impacts of abstraction layers on their ability to successfully do work, and the varied perceptions of time that shape this work. Examining the adoption of the Cori HPC at NERSC we explore the anticipations and lived experiences of users interacting with this system’s novel storage feature, the Burst Buffer. We present lessons learned from across these insights to illustrate just some of the challenges HPC facilities and their stakeholders need to account for when procuring and supporting these essential scientific resources to ensure their usability and utility to a variety of scientific practices.

97 MATHEMATICS AND COMPUTING↗

VERA Integration in the NEAMS Workbench

The Virtual Environment for Reactor Applications (VERA) is a cutting edge simulation code suite used to solve complex multiphysics problems for nuclear reactors. VERA makes use of high performance computing (HPC) systems to solve large problems that were not historically tractable. While extensive work has been put into the usability of VERA, it still takes significant effort to build reactor models, ensure their correctness, properly execute the calculations, and conduct the necessary analysis of the results. This difficulty is common for many complex codes such as VERA. As part of the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, the NEAMS Workbench has been developed and maintained. The goal of the NEAMS Workbench is to provide a single interface with which to execute a wide variety of physics codes, from building the input models to analyzing the results. This document serves as a manual detailing the current integration of VERA with the NEAMS Workbench and a guide for configuring Workbench to allow remote execution of VERA.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A New State of the Art: Zero Energy Modular Multifamily Construction

In 2020, the U.S. Department of Energy's Building Technologies Office (BTO) launched the Advanced Building Construction (ABC) Initiative. This initiative aimed to integrate energy efficiency into high-production construction practices. One focus area of the initiative is off-site construction, an approach that may achieve scalable, efficient, and high-performing construction buildings through process standardization. This report presents the findings and recommendations from our ABC Initiative project: A New State of the Art: Zero-Energy Modular Multifamily Construction System. The objectives of the BTO-funded project are to: 1) Achieve energy performance 50% better than the 2018 International Energy Conservation Code (IECC). 2) Achieve this level of energy performance at no additional cost VEIC worked with Louisiana State University (LSU), National Renewal Energy Lab (NREL), [the project team], and industry partners at the Mod Coach, KBS, and Solar Home Factory to identify and analyze multifamily business designs and modular construction practices. These designs and processes hold the promise of achieving the goals set out by the DOE.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Distribution System Operator with Transactive (DSO+T) Study

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. Using a highly interdisciplinary co-simulation and valuation framework, this assessment encompasses the entire electrical delivery system from bulk system generation and transmission, through the distribution system, to the modeling of individual customer buildings and flexible assets (including heating, ventilation, and air conditioning [HVAC] units, water heaters, batteries, and electric vehicles). The study exercises a transactive energy retail market coordination scheme designed to integrate with an existing day-ahead and real-time competitive wholesale electricity market. Software decision-making agents are designed for the retail market operator as well as various price-responsive flexible assets. The engineering and economic performance of the transactive energy scheme is studied for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distribution System Operator with Transactive (DSO+T) Study: Volume 1 (Main Report)

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. Using a highly interdisciplinary co-simulation and valuation framework, this assessment encompasses the entire electrical delivery system from bulk system generation and transmission, through the distribution system, to the modeling of individual customer buildings and flexible assets (including heating, ventilation, and air conditioning [HVAC] units, water heaters, batteries, and electric vehicles). The study exercises a transactive energy retail market coordination scheme designed to integrate with an existing day-ahead and real-time competitive wholesale electricity market. Software decision-making agents are designed for the retail market operator as well as various price-responsive flexible assets. The engineering and economic performance of the transactive energy scheme is studied for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Experimental and Modeled Assessment of Interventions to Reduce PM2.5 in a Residence during a Wildfire Event

Increasingly large and frequent wildfires affect air quality even indoors by emitting and dispersing fine/ultrafine particulate matter known to pose health risks to residents. With this health threat, we are working to help the building science community develop simplified tools that may be used to estimate impacts to large numbers of homes based on high-level housing characteristics. In addition to reviewing literature sources, we performed an experiment to evaluate interventions to mitigate degraded indoor air quality. We instrumented one residence for one week during an extreme wildfire event in the Pacific Northwest. Outdoor ambient concentrations of PM2.5 reached historic levels, sustained at over 200 μg/m3 for multiple days. Outdoor and indoor PM2.5 were monitored, and data regarding building characteristics, infiltration, and mechanical system operation were gathered to be consistent with the type of information commonly known for residential energy models. Two conditions were studied: a high-capture minimum efficiency rated value (MERV 13) filter integrated into a central forced air (CFA) system, and a CFA with MERV 13 filtration operating with a portable air cleaner (PAC). With intermittent CFA operation and no PAC, indoor corrected concentrations of PM2.5 reached 280 μg/m3, and indoor/outdoor (I/O) ratios reached a mean of 0.55. The measured I/O ratio was reduced to a mean of 0.22 when both intermittent CFA and the PAC were in operation. Data gathered from the test home were used in a modeling exercise to assess expected I/O ratios from both interventions. The mean modeled I/O ratio for the CFA with an MERV 13 filter was 0.48, and 0.28 when the PAC was added. The model overpredicted the MERV 13 performance and underpredicted the CFA with an MERV 13 filter plus a PAC, though both conditions were predicted within 0.15 standard deviation. The results illustrate the ways that models can be used to estimate indoor PM2.5 concentrations in residences during extreme wildfire smoke events.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗