Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Overview of high-temperature materials for high-energy space power systems

The current state of technology and some of the more pressing research needs and challenges associated with the possible use of high temperature materials in future high energy space power systems are discussed. Particularly, emphasis is on the need to improve and quantify the fundamental understanding of the effects of the following: (1) fast neutron radiation on the properties and behavior of nuclear reactor fuels and claddings; and (2) long term, high temperature, space (vacuum) exposure on the properties of refractory metals considered for use as structural materials in various power conversion systems.

Saunders, N. T.↗

Data for A Role for Differential Rubisco Activase Isoform Expression in C4 Bioenergy Grasses at High Temperature

Rubisco activase (Rca) facilitates the release of sugar-phosphate inhibitors at Rubisco catalytic sites during CO2 fixation. Most plant species express two Rca isoforms, the larger Rca-α and the shorter Rca-β, either by alternative splicing from a single gene or expression from separate genes. The mechanism of Rubisco activation by Rca isoforms has been intensively studied in C3 plants. However, the functional role of Rca in C4 plants where Rubisco and Rca are located in a much higher [CO2] compartment is less clear. In this study, we selected four C4 bioenergy grasses and the model C4 grass setaria ( Setaria viridis ) to investigate the role of Rca in C4 photosynthesis. All five C4 grass species contained two Rca genes, one encoding Rca-α and the other Rca-β, which were positioned closely together in the genomes. A variety of abiotic stress-related motifs were identified in the Rca-α promoter of each grass, and while the Rca-β gene was constantly highly expressed at ambient temperature, Rca-α isoforms were expressed only at high temperature but never surpassed 30% of Rca-β content. The pattern of Rca-α induction on transition to high temperature and reduction on return to ambient temperature was the same in all five C4 grasses. In sorghum ( Sorghum bicolor ), sugarcane ( Saccharum officinarum ), and setaria, the induction rate of Rca-α was similar to the recovery rate of photosynthesis and Rubisco activation at high temperature. This association between Rca-α isoform expression and maintenance of Rubisco activation at high temperature suggests that Rca-α has a functional thermo-protective role in carbon fixation in C4 grasses by sustaining Rubisco activation at high temperature.

Genomics↗

Voltage cycling as a dynamic operation mode for high temperature electrolysis solid oxide cells

Solid Oxide Electrolysis Cells (SOECs) have emerged as a promising technology for the efficient production of H2 via high-temperature electrolysis. However, power input from dynamic energy sources remains a significant challenge for their long-term stability. It is important to analyze the tolerance of cells under dynamic operation conditions. This study focuses on evaluating the impact of voltage cycling on the performance and durability of electrode-supported SOECs. We explore the operational limits and degradation mechanisms of SOECs subjected to various voltage conditions and find that the cells have high tolerance for dynamic voltage. Voltage cycling between 1.3 V and 1.5 V for 9000 cycles does not damage the cell. Conversely, cycling to higher voltages (≥1.7 V) results in accelerated degradation. Advanced characterization is used to screen for various degradation modes post operation. Within the oxygen electrode, XRD and STEM EDS find compositional and phase evolution in all voltage cycled samples including increased decomposition of the air electrode resulting in cation migration. Microstructural analysis of the fuel electrode from nano-CT data shows minimal change throughout the sample set and no evidence of Ni migration, indicating the fuel electrode is stable and not impacted by cycling to higher voltages within the timeframe studied.

Zhu, Zhikuan↗

High-temperature all-fiber non-destructive multi-parameter sensing system with consistent performance

A high-temperature all-fiber non-destructive multi-parameter sensing system is developed. The system can operate consistently in a wide range of temperature changes by specially designed active signal generation and detection units. It is capable of monitoring temperature up to 600°C and cracks on metal pipes with an acoustic wave generation unit and an acoustic detection unit. A gold-coated multi-mode fiber is used to deliver a laser pulse for acoustic excitation while minimizing parasitic acoustic signals at high temperature. An in-fiber Fabry–Perot fiber Bragg grating (FP-FBG) is fabricated in another single-mode fiber and bonded to the test object for acoustic detection. The FP-FBG avoids strain redistribution inside the bonder at high temperature to ensure consistent operation. The feasibility of the system for temperature monitoring and crack detection in real-world applications is also demonstrated on an industry-standard P91 pipe.

He, Jiaji (ORCID:0000000165661887)↗

Validation Studies of RELAP5-3D for High-Temperature Gas-Cooled Reactor Analysis Using a Refined RELAP5-3D Model of the High Temperature Test Facility

RELAP5-3D has been used extensively for high-temperature gas-cooled reactor (HTGR) analysis, but such analysis lies outside the validation basis for the code. Oregon State University (OSU) and the United States Department of Energy’s (DOE) Advanced Reactor Technologies (ART) – Gas-cooled reactor campaign worked together to design and operate the High Temperature Test Facility (HTTF) at OSU to provide validation data for prismatic HTGR thermal hydraulics analysis. Work using a previous RELAP5-3D model of HTTF demonstrated the ability to reproduce trends in HTTF data but an inability to reproduce the values measured in multiple experiments within the uncertainty. It was hypothesized that a new model with a finer radial nodalization would perform better for HTTF analysis. In this paper, we present the development of that more refined model and analyze HTTF experiments PG-27 and PG-29, a pressurized (PCC) and depressurized conduction cooldown (DCC) transient. Comparing PG-27 results to experimental data shows a better prediction of steady state and transient temperatures; however, a deeper dive reveals that better transient temperature predictions are a result of better initial conditions. The transient temperature rise in the core is comparable between the two models, but the legacy model predicts temperatures in the reflectors better. The new model demonstrates the ability to predict unique temperatures in each sector of the core during PG-29, capturing the azimuthal asymmetry; however, the temperature predictions still differ from measured temperatures. One hypothesis is that differences between the assumed and actual power distribution leads to the underprediction of the individual block temperatures. These results suggest that gaps and uncertainties in the measured boundary conditions for the HTTF tests do not allow to fully validate RELAP5-3D for prismatic HTGR analyses. The authors suspect that some of the differences between predicted and measured temperatures may be a result of uncertainties associated with HTTF itself rather than RELAP5-3D. We demonstrated improved validation for steady-state analysis, but significantly improved transient performance has yet to be recognized.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of High Temperature (>700°C) molten Salt Pump Technology for Gen3 Solar Power Tower Systems

Generation 3 Concentrating Solar Power (CSP) Systems require thermal energy storage that can efficiently receive solar heat and deliver it to a working fluid at temperatures greater than 700°C. For liquid systems, the thermal transfer fluid must be phase stable over large temperature ranges. High temperature molten salts meet this criteria, but are difficult liquids to handle. The high heat and salt content can be very corrosive to several different materials that are wetted by the liquid salt. For power tower collectors, the molten salt must be pumped under high pressure to the top of the collector tower. These pumps have impellers and shafts as part of their rotating elements, and under load, require bearings to control shaft movement while rotating. These high temperature pumps require submerged bearings, and thus bearing materials that can withstand the temperature and molten salt contact over long periods of time. This is essential for keeping pump maintenance costs low, and downtime to a minimum. Long running bearing materials is an enabling technology for integrated liquid systems in Generation 3 CSP Systems. Keeping costs low and systems reliable are critical for the broad adoption of Gen 3 CSP Systems. Hayward Tyler, Inc (HTI) proposed development of journal bearing materials for use in vertical pumps designed for pumping high temperature molten salt on both the hot and cold sides of the solar power tower. To complete this objective, HTI utilized the testing capabilities of Oak Ridge National Laboratory (ORNL) and High Temperature System Design (HTSD). Materials would first be selected for static corrosion testing, then downselected for tribological testing. Successful tribologically tested materials would then be downselected for use in additional test regimes. Ten samples were selected for static corrosion testing. Three passed the static testing regime. Two of these materials were downselected for ball material in tribological testing against three metallic alloys: Sintered Y2O3 Partially Stabilized Zirconia YTZP and Silicon Nitride, Grade 147-31N. HTI also proposed collecting data from a thorough bearing test regime using a test rig designed and built as part of this project, and also a conceptual design for a high temperature molten salt vertical pump. HTI withdrew from the project prior to completion of this work and this report reflects only the work completed prior to withdrawal. The completed work produced two papers, one manuscript submitted for publication, and one paper published in the journal Solar Energy Materials and Solar Cells. The papers are: “Tribological behavior of ceramic-alloy bearing contacts in molten salt lubrication for concentrating solar power” and “Material Selection and Corrosion Studies Of Candidate Bearing Materials For Use In Molten Chloride Salt."

14 SOLAR ENERGY↗

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of Microwave Resonant Cavity Transducer. Development of sensor performance model of microwave cavity flow meter for advanced reactor high temperature fluids

High-temperature fluid reactors, such as molten salt cooled reactors (MSCR) and sodium fast reactors (SFR), are a promising advanced reactor option. Measurement of high-temperature fluid process variables, in particular the flow inside the pressure vessel, is a challenging task because of harsh environment, which includes high radiation, high temperature, and contact with highly corrosive coolant fluid. We are investigating a microwave cavity-based transducer for high-temperature fluid flow sensing. This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. A cavity is characterized by its resonant frequencies. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the flow sensor is evaluated with signal sensitivity using COMSOL computer simulations. A right cylinder geometry stainless steel cavity with dimeter of 0.8in was investigated. We choose membrane thickness of 10mil, so that corrosion anticipated to proceed at the rate of 1mil/year in liquid sodium would affect no more than 10% of the membrane. Using the properties of liquid sodium fluid, and stainless-steel material property values at 500oC, we calculate frequency shift for a range of values of fluid velocity from 0.5m/s to 2m/s. Results of computer simulations indicate measurable sensitivity to flow for this cavity design. Following these simulations, we have developed a preliminary design for fabrication of a transducer operating in microwave K-band for proof-of-principle tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

In Situ Transmission Electron Microscopy of High-Temperature Inconel-625 Corrosion by Molten Chloride Salts

This paper describes an approach to monitor high temperature molten chloride (MgCl 2 -NaCl-KCl) salt corrosion of Inconel-625 alloy in real time at high spatial resolution. The approach is based on a micro-environmental-cell assembly integrated into a transmission-electron-microscope goniometer to examine in situ the salt-alloy interface during corrosion, employing real time electron diffraction and imaging. It establishes procedures to minimize incorporation of H 2 O or O 2 from atmosphere in the chloride salts during sample fabrication and corrosion, which is critical to understanding the fundamental corrosion mechanisms. A clustering algorithm and a 2D Gaussian fit function are used to determine diffraction spot intensities in in situ diffraction patterns, to quantify alloy corrosion. This facilitates quantitative observation of the evolution of individual grains, in contrast to conventional macroscopic corrosion rate quantification. The isothermal corrosion rate of Inconel-625 in an anhydrous, unoxidized salt-stack is 220 ± 30 μm year -1 at 700 °C and 350 ± 20 μm year -1 at 800 °C. However, the corrosion rate at 700 °C increases five-fold to 1000 ± 170 μm year -1 when the salt stack is air-exposed, indicating the dominant effects of hydrated or oxidized impurities on corrosion acceleration. Furthermore, real time imaging of the microstructure evolution suggests that corrosion is initiated at grain boundaries.

14 SOLAR ENERGY↗

Novel Geochemistry Determined from High Pressure, High Temperature Simulation Experiments of Hydraulic Fracture Test Site 2

A standard method in unconventional oil and gas production is the process of hydraulic fracturing followed by a shut-in period, during which the fracture fluid remains pressurized in the reservoir for up to three weeks before production begins. Despite this widely used process, very little is known about what occurs in the reservoir during this shut-in process. In order to properly delineate potential reservoir reactions that may occur during shut-in that would lead to corrosion and scaling events, experiments were conducted in high pressure, high temperature reactors to simulate conditions of the Wolfcamp Formation in the Delaware Basin. Experimental design allowed the assessment of the effect of proppant, microbiology, and time on the mineralogy and fluid chemistry in the reservoir. Results suggest the biggest impact on fluid chemistry and shale mineralogy during shut-in is time. Analyses demonstrate dissolution of the shale material, with maximum dissolved ions occurring after 7 days of the shut-in period. After 21 days, results suggest precipitation occurs. The Delaware Basin is demonstrated to be high in sulfate content, which further increases in the fluid due to dissolution reactions during shut-in. The pressure vessel experiments suggest there was no significant contribution to reactions from microbiology during the shut-in period. Furthermore, early production samples demonstrate a significant selection of the microorganism Caminicella, a genus of which has previously been correlated to corrosion and sulfide production. Results suggest shut-in conditions may provide high sulfate concentrations that could later be utilized by a shifted microbial community to drive potential well infrastructure failure. This is the first study to incorporate microbiology, mineralogy, and fluid chemistry to investigate the fundamental geochemical reactions that occur during shut-in and early phase production of the Delaware Downloaded from http://onepetro.org/URTECONF/proceedings-pdf/21URTC/2-21URTC/D021S032R001/2477425/urtec-2021-5219-ms.pdf/1 by Carol Worster on 28 February 2022 Basin. Results from this study can complement observations from the Hydraulic Fracture Test Site 2 observations

58 GEOSCIENCES↗