Search NASA⌕ Search

SEARCH · Search NASA

Results for “High gradient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Mechanical properties of high gradient and hot isostatically pressed PWA 1480

This program has been designed to evaluate the potential benefits to alloy 1480 material properties due to high thermal gradient casting, hot isostatic pressing, and alternative heat treatment. Alloy 1480 castings have been obtained from vendors representing the extremes of commercial casting thermal gradients. Quantitative characterization of the dendrite arm spacing (DAS) and pore distributions has been conducted. A hot isostatic pressing (HIP) schedule, which avoids the many pitfalls of single crystal HIP has been devised for alloy 1480. In addition, an alternate heat treatment for alloy 1480 has been devised which provides benefits in mechanical properties. The standard gradient cast test material is being evaluated in the standard heat treat condition as a baseline and in the HIP plus alternate heat treated condition. The fhigh gradient cast material is being evaluated in alternate heat treat and HIP plus alternate heat treated conditions. Evaluations focus on demonstration of the benefits due to the applied processes, especially in the area of cyclic life.

Fritzemeier, L. G.↗

First high gradient test results of a dressed 325 MHz superconducting single spoke resonator at Fermilab

A new superconducting RF cavity test facility has been commissioned at Fermilab in conjunction with first tests of a 325 MHz, {beta} = 0.22 superconducting single-spoke cavity dressed with a helium jacket and prototype tuner. The facility is described and results of full gradient, CW cavity tests with a high Q{sub ext} drive coupler are reported. Sensitivities to Q disease and externally applied magnetic fields were investigated. Results are compared to bare cavity results obtained prior to hydrogen degassing and welding into the helium jacket.

43 PARTICLE ACCELERATORS↗

CABOTO, a high-gradient linac for hadrontherapy

The field of hadrontherapy has grown rapidly in recent years. At present the therapeutic beam is provided by a cyclotron or a synchrotron, but neither cyclotrons nor synchrotrons present the best performances for hadrontherapy. The new generation of accelerators for hadrontherapy should allow fast active energy modulation and have a high repetition rate, so that moving organs can be appropriately treated in a reasonable time. In addition, a reduction of the dimensions and cost of the accelerators for hadrontherapy would make the acquisition and operation of a hadrontherapy facility more affordable, which would translate into great benefits for the potential hadrontherapy patients. The ‘cyclinac’, an accelerator concept that combines a cyclotron with a high-frequency linear accelerator (linac), is a fast-cycling machine specifically conceived to allow for fast active energy modulation. The present paper focuses on CABOTO (CArbon BOoster for Therapy in Oncology), a compact, efficient high-frequency linac that can accelerate C 6+ ions and H 2 molecules from 150– 410 MeV/u in ~24 m. The paper presents the latest design of CABOTO and discusses its performances.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High Gradient Accelerator Cavities Using Atomic Layer Deposition

In the Phase I program, Calabazas Creek Research, Inc. (CCR), in collaboration with North Carolina State University (NCSU), fabricated copper accelerator cavities and used Atomic Layer Deposition (ALD) to apply thin metal coatings of tungsten and platinum. It was hypothesized that a tungsten coating would provide a robust surface more resistant to arcing and arc damage. The platinum coating was predicted to reduce processing time by inhibiting oxides that form on copper surfaces soon after machining. Two sets of cavity parts were fabricated. One was coated with 35 nm of tungsten, and the other with approximately 10 nm of platinum. Only the platinum cavity parts could be high power tested during the Phase I program due to schedule and funding constraints. The platinum coated cavity exhibit poor performance when compared with pure copper cavities. Not only did arcing occur at lower power levels, but the processing time was actually longer. There were several issues that contributed to the poor performance. First, machining of the base copper cavity parts failed to achieve the quality and cleanliness standards specified to SLAC National Accelerator Center. Secondly, the ALD facilities were not configured to provide the high levels of cleanliness required. Finally, the nanometer coating applied was likely far too thin to provide the performance required. The coating was ablated or peeled from the surface in regions of high fields. It was concluded that the current ALD process could not provide improved performance over cavities produced at national laboratories using dedicated facilities.

43 PARTICLE ACCELERATORS↗

The LLNL/UCLA high gradient inverse free electron laser

We describe the Inverse Free Electron Accelerator currently under construction at Lawrence Livermore National Lab. Upon completion of this accelerator, high brightness electrons generated in the photoinjector blowout regime and accelerated to 50 MeV by S-band accelerating sections will interact with > 4 TW peak power Ti:Sapphire laser in a highly tapered 50 cm undulator and experience an acceleration gradient of > 200 MeV/m. We present the final design of the accelerator as well as the results of start-to-end simulations investigating preservation of beam quality and tolerances involved with this accelerator.

43 PARTICLE ACCELERATORS↗

The influence of ions and the induced secondary emission on the nanosecond high-gradient microwave breakdown at metal surface

The mechanism of ultrafast breakdown at metal/vacuum interface in the high-power microwave waveguides is studied. In order to realize the nanosecond discharge, the required ambient gas pressure above the metal surface is approximately calculated as high as several Torr due to the low ionization-rate for high-energy electrons and short pulse. The local high pressure may come from the evaporated microscopic protrusions due to Joule heating and gas desorption. Besides, ions accelerated by the ambient space charge field could obtain sufficient high energy to collide and sputter the metal atoms to increase the ambient pressure. The positive feedbacks during the rapid discharge are studied by particle-in-cell simulation. The relatively high-energy ions could generate secondary electrons. It is shown that, as the positive feedback, the secondary electrons induce the gas desorption and stronger ionization, resulting in ion and electron density increasing as well as sheath field further increasing. As a result, more higher-energy ions bombard metal surface, leading to higher secondary electron yield and higher density plasma generated to cut off the microwave transmission finally. These nonlinear courses realize the ultrafast discharge in waveguides.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Chemical Free Surface Processing for High Gradient Superconducting RF Cavities

Chemical treatment such as buffered chemical polishing (BCP) or electro polishing (EP) followed by high pressure rinsing (HPR) of niobium (Nb) superconducting RF (SRF) cavities is expensive and complex multistep process. Furthermore, the cavity RF surfaces after the treatment still have numerous bubbles and pits that result from welding. These quench-producing weld defects together with the particulate contamination, result in significant scatter of the multi-cell Nb SRF cavities performance characteristics. This scatter is the major problem in the current manufacturing of the Nb SRF cavities. When developed the chemical free surafce processing using IEB will benefit first J-lab's CEBAF and Fermilab's Project X. Also, light sources, require 1.3 - 1.5 GHz SRF structures. Furthermore, IEB will produce much broader impact because it can be implemented into manufacturing of many other types of RF devices including both superconducting as well as normal conducting RF cavities. This program will develop a new process that will enhance quality of the superconducing radio-frequency cavities and allow acceleration of charged particles to much higher energies. The process also will improve the cavity manufacturing and result in substantial cost reduction of superconducting radio-frequency high-energy particle accelerators. Niobium samples were successfully processed by a DC electron beam to a degree that is suitable for the interior surface of an SRF cavity. To accomplish this, a complete system was developed from the ground up. A vacuum chamber system was acquired and adapted to act as the vessel for performing the Nb processing experiments. An extremely robust high voltage power supply was developed and manufactured to provide the power necessary to drive the multi-kW DC electron gun. A high voltage isolation filament transformer was also designed and manufactured to provide the necessary current to drive the filament within the electron gun. Finally, a beam melt characterization DC electron gun was created. This gun was used to explore the parameter space of interest for processing Nb SRF cavities. The beam melt characterization tests concluded that multiple quick passes at moderate beam power provided the most ideal melt zone characteristics Nb surfaces. It was also found that excellent melt and polish results could be achieved at lower voltages than originally conceived, getting the great results at a beam voltage of 20kV versus the 50kV used in the initial Phase I testing at Jefferson Laboratory. Operating at 20kV will also greatly reduce the challenges of designing a compact DC electron gun for processing of complete Nb SRF cavities, which will be done in Phase III. This final report is divided in eight parts which cover the major investigation work and results which have been performed and achieved. The first part addresses the design, fabrication and testing of the vacuum chamber. In the second part, the DC power supply output circuit design is presented for providing an operating space of 50-60kV with currents from 20-160mA and short and open circuit fault modes are considered and resolved. The third section covers testing and commissioning of the high voltage step up transformer and 150kV isolation transformer. Section four covers the design, construction and performance for a 100kV high voltage bushing. Section number five treats the filament design and load testing. Section number six covers electron gun design and simulation of electron beam melting. Section seven presents the beam target design, assembly and testing and test gun with solenoid magnet, design, fabrication and testing. Finally, section eight demonstrates electron beam melting and polishing of Nb, Cu and SS samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advances in high gradient normal conducting accelerator structures

Here, this paper reviews the current state-of-the-art in understanding the phenomena of ultra-high vacuum radio-frequency (rf) breakdown in accelerating structures and the efforts to improve stable operation of the structures at accelerating gradients above 100 MV/m. Numerous studies have been conducted recently with the goal of understanding the dependence of the achievable accelerating gradients and breakdown rates on the frequency of operations, the geometry of the structure, material and method of fabrication, and operational temperature. Tests have been conducted with single standing wave accelerator cells as well as with the multi-cell traveling wave structures. Notable theoretical effort was directed at understanding the physical mechanisms of the rf breakdown and its statistical behavior. Finally, the achievements presented in this paper are the result of the large continuous self-sustaining collaboration of multiple research institutions in the United States and worldwide.

43 PARTICLE ACCELERATORS↗

New accelerator capabilities with the high-gradient C-band [Slides]

LANSCE accelerator upgrades: Applications such as pRad desire higher proton beam energy. Material science at LANL will benefit from powerful directional high repetition rate X-ray sources. As it considers itself to be the NNSA accelerator laboratory, LANL should play role in developing compact accelerators for various national security missions.

43 PARTICLE ACCELERATORS↗

Temperature profiles in high gradient furnaces

Accurate temperature measurement of the furnace environment is very important in both the science and technology of crystal growth as well as many other materials processing operations. A high degree of both accuracy and precision is acutely needed in the directional solidification of compound semiconductors in which the temperature profiles control the freezing isotherm which, in turn, affects the composition of the growth with a concomitant feedback perturbation on the temperature profile. Directional solidification requires a furnace configuration that will transport heat through the sample being grown. A common growth procedure is the Bridgman Stockbarger technique which basically consists of a hot zone and a cold zone separated by an insulator. In a normal growth procedure the material, contained in an ampoule, is melted in the hot zone and is then moved relative to the furnace toward the cold zone and solidification occurs in the insulated region. Since the primary path of heat between the hot and cold zones is through the sample, both axial and radial temperature gradients exist in the region of the growth interface. There is a need to know the temperature profile of the growth furnace with the crystal that is to be grown as the thermal load. However it is usually not feasible to insert thermocouples inside an ampoule and thermocouples attached to the outside wall of the ampoule have both a thermal and a mechanical contact problem as well as a view angle problem. The objective is to present a technique of calibrating a furnace with a thermal load that closely matches the sample to be grown and to describe procedures that circumvent both the thermal and mechanical contact problems.

Fripp, A. L.↗

The Role of Oxygen Concentration in Enabling High Gradients in Niobium SRF Cavities

We studied the role of O concentration with depth in the performance of Nb SRF cavities. An ensemble of electropolished 1.3 GHz cavities, which initially showed high field Q-slope (HFQS), was subjected to sequential testing and treatment with in-situ low temperature baking at various temperatures. We find that increasing the bake duration causes (i) an increase in the onset of HFQS until it is absent up to quench (ii) a non-monotonic relationship with the quench field (iii) an evolution of the RBCS toward a non-equilibrium behavior that drives anti-Q slope. Our data is qualitatively explained by assuming an O diffusion model and suggests that the mitigation of HFQS that arises from 120 C in-situ LTB is mediated by the diffusion of O from the native oxide which prevents the precipitation of proximity-coupled Nb nano-hydrides, in turn enabling higher quench fields. The decrease in quench field for cavities in which O has been diffused >90 nm from the RF surface may be due to a reduction of the field limit in the SS bilayer structure. We also suggest that the evolution of the RBCS occurs due to the absence of proximity coupled inclusions, bringing about non-equilibrium effects.

Bafia, D.↗

Design, fabrication, and high-gradient testing of an X -band, traveling-wave accelerating structure milled from copper halves

A prototype 11.994 GHz, traveling-wave accelerating structure for the Compact Linear Collider has been built, using the novel technique of assembling the structure from milled halves. The use of milled halves has many advantages when compared to a structure made from individual disks. These include the potential for a reduction in cost, because there are fewer parts, as well as a greater freedom in choice of joining technology because there are no rf currents across the halves’ joint. Here we present the rf design and fabrication of the prototype structure, followed by the results of the high-power test and post-test surface analysis. During high-power testing the structure reached an unloaded gradient of 100 MV / m at a rf breakdown rate of less than 1.5×10 –5 breakdowns / pulse / m with a 200 ns pulse. Furthermore, this structure has been designed for the CLIC testing program but construction from halves can be advantageous in a wide variety of applications.

43 PARTICLE ACCELERATORS↗

High gradient research and facilities at Los Alamos National Laboratory [Slides]

A particle accelerator is a scientific instrument that produces a directional stream of electrically charged particles, usually electrons or protons. The accelerator propels particles to high speeds, close to the speed of light. Historically, accelerators play a crucial role in scientific discovery. Nowadays, accelerators produce particle beams for biomedical and material research, manufacturing, energy technology, and Homeland security.

43 PARTICLE ACCELERATORS↗