Very high-vacuum heat treatment facility

A vacuum heat treatment facility, with hot zone dimensions of 12 x 19 x 19 cm, has been designed and constructed at a cost substantially below that of a commercial unit. The design incorporates efficient water cooling and a resistive heating element. A vacuum pressure of 1.5 x 10 to the -8th torr at room temperature has been obtained after baking. The temperature limit is approximately 1900 C. This limit results from the choice of niobium as the hot zone material.

Folkner, W. M.↗

Decomposition of perfluoroalkylpolyethers (PFPE) in ultra-high vacuum under sliding conditions

Reactions of perfluoroalkylpolyethers (PFPE: Fomblin, Demnum and Krytox) were studied during the sliding contact of stainless steel specimens under ultrahigh vacuum conditions. All three fluids reacted with the steel specimens during sliding. Fomblin, which has acetal linkages, decomposed under the sliding conditions generating gaseous products, (COF2 and fluorinated carbons) which were detected by a quadrupole mass spectrometer. Gaseous products were not detected for the Demnum and Krytox fluids. The amount of gaseous products from Fomblin increased with increasing sliding speed. At the end of the sliding experiments, the wear scar and deposits on the specimens were examined by small spot size XPS. The oxide layer on the specimen surface was removed during sliding, and metal fluorides were formed on the worn surface. The surface of the wear scar and deposits were covered with adsorbed PFPE. Based on these results, it was concluded that the decomposition reaction on Fomblin was initiated by contacting the fluid with a fresh metal surface which was formed during sliding.

Mori, Shigeyuki↗

Analysis of high vacuum systems using SINDA'85

The theory, algorithms, and test data correlation analysis of a math model developed to predict performance of the Space Station Freedom Vacuum Exhaust System are presented. The theory used to predict the flow characteristics of viscous, transition, and molecular flow is presented in detail. Development of user subroutines which predict the flow characteristics in conjunction with the SINDA'85/FLUINT analysis software are discussed. The resistance-capacitance network approach with application to vacuum system analysis is demonstrated and results from the model are correlated with test data. The model was developed to predict the performance of the Space Station Freedom Vacuum Exhaust System. However, the unique use of the user subroutines developed in this model and written into the SINDA'85/FLUINT thermal analysis model provides a powerful tool that can be used to predict the transient performance of vacuum systems and gas flow in tubes of virtually any geometry. This can be accomplished using a resistance-capacitance (R-C) method very similar to the methods used to perform thermal analyses.

Spivey, R. A.↗

Evaluation of Vapor Pressure and Ultra-High Vacuum Tribological Properties of Ionic Liquids (2) Mixtures and Additives

Ionic liquids are salts, many of which are typically viscous fluids at room temperature. The fluids are characterized by negligible vapor pressures under ambient conditions. These properties have led us to study the effectiveness of ionic liquids containing both organic cations and anions for use as space lubricants. In the previous paper we have measured the vapor pressure and some tribological properties of two distinct ionic liquids under simulated space conditions. In this paper we will present vapor pressure measurements for two new ionic liquids and friction coefficient data for boundary lubrication conditions in a spiral orbit tribometer using stainless steel tribocouples. In addition we present the first tribological data on mixed ionic liquids and an ionic liquid additive. Post mortem infrared and Raman analysis of the balls and races indicates the major degradation pathway for these two organic ionic liquids is similar to those of other carbon based lubricants, i.e. deterioration of the organic structure into amorphous graphitic carbon. The coefficients of friction and lifetimes of these lubricants are comparable to or exceed these properties for several commonly used space oils.

Morales, Wilfredo↗

Piezoelectrically Actuated Shutter for High Vacuum

A piezoelectrically actuated shutter is undergoing development for use in experiments on laser cooling of atoms. The shutter is required to be compatible with ultrahigh vacuum [pressure of 10(exp -9) torr (.1.3 x 10(exp -7) Pa) or less] and to be capable of performing reliably in the vacuum for at least one year. In operation, the shutter would enable the collection and launch of successive samples of cold atoms and would enable the interrogation of the immediately preceding sample while preventing disturbance of the atoms of that sample by light from the collection region. A major constraint is imposed on the design and operation of the shutter by a requirement that it not generate a magnetic field large enough to perturb an atomic clock. An electromagnetically actuated shutter could satisfy all requirements except this one. Hence, it was decided to use piezoelectric instead of electromagnetic actuation. The shutter (see figure) includes two commercial piezoelectrically driven flexure stages that produce a travel of 0.5 mm. Levers mechanically amplify the travel to the required level of 1 cm. Problems that remained to be addressed at the time of reporting the information for this article included lifetime testing and correction of a tendency for shutter blades to bounce open.

Thompson, Robert↗

Improved high voltage insulator for use in vacuum

High voltage insulator for electron bombardment ion thruster has electric field directed through dielectric material and electrons emitted by field emission are constrained in negative junction region. Surface flashover and unstable operation are eliminated, and maximum voltage is limited only by dielectric strength of material, aluminum oxide in this case.

Byers, D. C.↗

The solar UV environment and bacterial spore UV resistance: considerations for Earth-to-Mars transport by natural processes and human spaceflight

The environment in space and on planets such as Mars can be lethal to microorganisms because of the high vacuum and high solar radiation flux, in particular UV radiation, in such environments. Spores of various Bacillus species are among the organisms most resistant to the lethal effects of high vacuum and UV radiation, and as a consequence are of major concern for planetary contamination via unmanned spacecraft or even natural processes. This review focuses on the spores of various Bacillus species: (i) their mechanisms of UV resistance; (ii) their survival in unmanned spacecraft, space flight and simulated space flight and Martian conditions; (iii) the UV flux in space and on Mars; (iv) factors affecting spore survival in such high UV flux environments.

Review↗

Air lock mechanism speeds specimen testing in high-temperature vacuum furnaces

Mechanism, made of 347 stainless steel, is attached to furnace port by bolted flange. Unit incorporates quick opening, high vacuum valve and associated fittings which provide connections to air lock evacuation and to inert gas supply for quenching specimen after it is withdrawn from furnace into air lock.

Whitehead, C.↗

Emission tester for high-power vacuum tubes

A simple emission-testing circuit for high power vacuum tubes to check their output stability is described. With modification it may be useful in testing mercury-arc rectifiers.

Lundy, C.↗

Getters for Reliable Hermetic Packages

A variety of sealed-off devices such as cathode ray tubes (CRT's) electron tubes, plasma displays, particle accelarators and colliders vacuum thermal insulation, ultra-high vacuum (UHV), extreme high vacuum (XHV) systems for semiconductor processing, X-ray tubes, lamps, field-emission displays (FEDs) flat panel displays (FPDs), some microelectromechanical systems (MEMS) and science instruments for space applications, nuclear systems require a vacuum for their successful operation.

getters hermetic packaging electronic↗

A search for experiments to exploit the space shuttle environment, volume 1

A search for worthwhile experiments in pure and applied physics and chemistry which might take advantage of conditions achievable aboard the space shuttle is documented. Of particular interest were the very large pumping speeds at high or ultra high vacuum, the highly nonequilibrium composition of the ambient atmosphere, and the relative absence of gravitational effects. Ideas and suggestions were solicated in the course of visits to 31 research establishments in Western Europe, India, and Japan; conversations with over 90 scientists; and presentations at 3 international meetings. Intriguing possibilities emerged in the following arenas: (1) spectroscopy of the transition state in chemical reactions; (2) flame structure and analysis; (3) solid propellant combustion; (4) analysis of atmospheric composition; (5) turbulence effects on aerosol coagulation.

Fenn, J. B.↗