Search NASA⌕ Search

SEARCH · Search NASA

Results for “INGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Dark Energy Survey Year 6 Results: Cosmological Constraints from Galaxy Clustering and Weak Lensing

We present cosmology results combining galaxy clustering and weak gravitational lensing measured in the full six years (Y6) of observations by the Dark Energy Survey (DES) covering $\sim$5000 deg$^2$. We perform a large-scale structure analysis using three two-point correlation functions (3$\times$2pt): (i) cosmic shear from 140 million source galaxy shapes, (ii) galaxy clustering of 9 million lens galaxy positions, and (iii) galaxy-galaxy lensing from their cross-correlation. We model the data in flat $Λ$CDM and $w$CDM cosmologies. The combined analysis yields $S_8\equiv σ_8 (Ω_{\rm m}/0.3)^{0.5} = 0.789^{+0.012}_{-0.012}$ and matter density $Ω_{\rm m} = 0.333^{+0.023}_{-0.028}$ in $Λ$CDM (68% CL), where $σ_8$ is the clustering amplitude. These constraints show a (full-space) parameter difference of 1.8$σ$ from a combination of cosmic microwave background (CMB) primary anisotropy datasets from Planck 2018, ACT-DR6, and SPT-3G DR1. Projected only into $S_8$ the difference is $2.6σ$. In $w$CDM the Y6 3$\times$2pt results yield $S_8 = 0.782^{+0.021}_{-0.020}$, $Ω_{\rm m} = 0.325^{+0.032}_{-0.035}$, and dark energy equation-of-state parameter $w = -1.12^{+0.26}_{-0.20}$. For the first time, we combine all DES dark-energy probes: 3$\times$2pt, SNe Ia, BAO and Clusters. In $Λ$CDM this combination yields a $2.8σ$ parameter difference from the CMB. When combining DES 3$\times$2pt with other low-redshift datasets (DESI DR2 BAO, DES SNe Ia, SPT clusters), we find a 2.3$σ$ parameter difference with CMB. A joint fit of Y6 3$\times$2pt, CMB, and those low-redshift datasets produces the tightest $Λ$CDM constraints to date: $S_8 = 0.806^{+0.006}_{-0.007}$, $Ω_{\rm m} = 0.302^{+0.003}_{-0.003}$, $h = 0.683^{+0.003}_{-0.002}$, and $\sum m_ν< 0.14$ eV (95% CL). In $w$CDM, this combination yields $w = -0.981^{+0.021}_{-0.022}$.

Abbott, T. M.C. [Cerro-Tololo InterAmerican Obs.]↗

Isotopic analysis of sub-nanogram neodymium loads using new ATONA™ amplifiers

The long-term gains of the ATONA™ amplifiers are shown to have less than 1 ppm variability. Repeat measurements of the JNdi-1 reference material demonstrate the ability of the ATONA™ amplification technology to make measurements of 143 Nd/ 144 Nd ratios with 23 ppm external reproducibility on 100-pg loads. The effect of increasing integration time on analytical reproducibility is also displayed as increasing integration time from 10 to 30s reduced the external measurement uncertainty from 37 to 23 ppm. These measurements represent an improvement of more than a factor of 3 in external measurement reproducibility relative to previously published 143 Nd/ 144 Nd measurements of 100-pg loads. Furthermore, this new technology will allow for the measurement of smaller samples for precise isotope ratios and open new avenues of research in the geological and nuclear forensic communities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Identifying preferential flow from soil moisture time series: Review of methodologies

Abstract Identifying and quantifying preferential flow (PF) through soil—the rapid movement of water through spatially distinct pathways in the subsurface—is vital to understanding how the hydrologic cycle responds to climate, land cover, and anthropogenic changes. In recent decades, methods have been developed that use measured soil moisture time series to identify PF. Because they allow for continuous monitoring and are relatively easy to implement, these methods have become an important tool for recognizing when, where, and under what conditions PF occurs. The methods seek to identify a pattern or quantification that indicates the occurrence of PF. Most commonly, the chosen signature is either (1) a nonsequential response to infiltrated water, in which soil moisture responses do not occur in order of shallowest to deepest, or (2) a velocity criterion, in which newly infiltrated water is detected at depth earlier than is possible by nonpreferential flow processes. Alternative signatures have also been developed that have certain advantages but are less commonly utilized. Choosing among these possible signatures requires attention to their pertinent characteristics, including susceptibility to errors, possible bias toward false negatives or false positives, reliance on subjective judgments, and possible requirements for additional types of data. We review 77 studies that have applied such methods to highlight important information for readers who want to identify PF from soil moisture data and to inform those who aim to develop new methods or improve existing ones. Core Ideas Soil moisture data can be used to identify the occurrence of preferential flow (PF) and its initiating conditions. Various data‐analysis methods to identify PF differ in susceptibility to error, bias, and subjectivity. These methods can utilize vast amounts of data from soil moisture monitoring networks to develop understanding of when, where, and under what conditions PF occurs. Newly developed methods may lead to better accuracy and reliability, and reduce the need for subjective judgments. Plain Language Summary Preferential flow through soil occurs when a large amount of water is suddenly available, as during an intense storm. This type of flow moves rapidly through the soil in distinct narrow pathways rather than moving evenly throughout the body of soil, with major consequences for groundwater resources, ecosystems, spreading of contaminants, and other vital concerns. Methods of detecting preferential flow have been developed that utilize measurements of soil water content made by sensors installed at various depths. This measurement technology has been widely implemented, many locations now having datasets years in length, and various methods have been developed for using these to identify preferential flow. The various methods are based on different features in the soil moisture records and vary in their advantages and shortcomings. In this review, we explain and evaluate these methods, highlighting important information for their implementation to identify preferential flow from soil moisture data and for efforts to develop new methods or improve existing ones.

Nimmo, John R↗

Fibrotic activity quantified in serum by measurements of type III collagen pro-peptides can be used for prognosis across different solid tumor types

Due to activation of fibroblast into cancer-associated fibroblasts, there is often an increased deposition of extracellular matrix and fibrillar collagens, e.g. type III collagen, in the tumor microenvironment (TME) that leads to tumor fibrosis (desmoplasia). Tumor fibrosis is closely associated with treatment response and poor prognosis for patients with solid tumors. To assure that the best possible treatment option is provided for patients, there is medical need for identifying patients with high (or low) fibrotic activity in the TME. Measuring unique collagen fragments such as the pro-peptides released into the bloodstream during fibrillar collagen deposition in the TME can provide a non-invasive measure of the fibrotic activity. Based on data from 8 previously published cohorts, this review provides insight into the prognostic value of quantifying tumor fibrosis by measuring the pro-peptide of type III collagen in serum of a total of 1692 patients with different solid tumor types and discusses the importance of tumor fibrosis for understanding prognosis and for potentially guiding future drug development efforts that aim at overcoming the poor outcome associated with a fibrotic TME.

59 BASIC BIOLOGICAL SCIENCES↗

A highly-enriched 244 Pu reference material for nuclear safeguards and nuclear forensics measurements

A highly-enriched 244 Pu isotope dilution reference material has been prepared and characterized for metrologically traceable measurements of very small quantities of plutonium. The amount of plutonium in samples associated with nuclear safeguards and nuclear forensic measurements can be significantly less than 1 ng. Accordingly, the ability to quantify the amount and isotopic composition of plutonium from a single mass-spectrometric analysis is particularly desirable. The highly-enriched 244 Pu reference material, described here, will minimize the magnitude of spike corrections necessary to obtain accurate information on plutonium isotopic composition from isotope dilution measurements.

07 ISOTOPE AND RADIATION SOURCES↗

An improved method for uranium separation from urine for rapid bioassay by inductively coupled plasma mass spectrometry

Bioassay monitoring is an important capability for any facility that works with significant amounts of radioactive material. The speed at which these analyses can be made is critical in the event of a potential exposure. Here, we present a new method that facilitates the rapid separation of uranium from a urine matrix for assay and isotopic determination by inductively coupled plasma mass spectrometry. This method is validated with archived urine samples that were previously analyzed using established, more time consuming methods. The sources of uncertainty for uranium assay and isotopic measurements are modelled using the Monte Carlo method to better understand the precision and accuracy of this method at the limit of quantification.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

New loading method for high precision Sm isotope analysis of nuclear materials using thermal ionization mass spectrometry

This work demonstrates an analytical protocol for high precision Sm isotope analysis by thermal ionization mass spectrometry (TIMS) using a Pt activator. Here, the method permits precise measurements of small aliquots (1–20 ng) of Sm on single Re filament using a modified static-total evaporation technique. This study represents the first attempt to use such protocols for Sm isotope analyses while reducing the loading size of Sm for TIMS. The method could potentially be deployed to study geological, meteorites and lunar samples containing low Sm concentrations, to monitor neutron irradiation exposure based on 149,150 Sm, or to measure Sm isotopic composition in other types of nuclear samples.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Collaborative Study for Certification of Trace Elements in Uranium Ore Concentrate CRMs UCLO-1, UCHI-1, and UPER-1

Trace impurity patterns are important nuclear forensic signatures in uranium ore concentrates (UOCs) and Certified Reference Materials (CRMs) are used to validate the analysis methods employed by end users. Herein, we discuss the certification campaign for three new UOC CRMs from the National Research Council Canada: UCLO-1 (https://doi.org/10.4224/crm.2020.uclo-1), UCHI-1 (https://doi.org/10.4224/crm.2020.uchi-1), and UPER-1 (https://doi.org/10.4224/crm.2020.uper-1). This study involved 15 laboratories from 10 countries, using sector-field and (triple) quadrupole inductively-coupled plasma mass spectrometry to analyze 64 trace element impurities. We discuss the importance of the acids used for sample digestion, difficulties analyzing in a high uranium matrix, and data combination and uncertainty evaluation for this large dataset.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

An introduction to the significance of sample size in particle analyses for nuclear forensics and radiological investigations

Particulate isotopic analysis in nuclear forensics has developed rapidly during the past two decades due to technical advances in determining the isotopic composition of individual particles. This paper introduces basic statistical concepts that can be applied by analysts to understand the importance of statistical adequacy when interpretating particle data. While these basic statistical methods provide a useful point-of-entry to particle data analysis, more sophisticated statistical and modeling approaches are needed to extract maximal information from such datasets in the future.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Single particle trace element analysis of uranium oxide standards with laser-induced breakdown spectroscopy

Femtosecond Laser-Induced Breakdown Spectroscopy (LIBS) was used to analyze over 1000 individual particles of uranium oxide trace element standard CRM124. Intra-granular analysis showed elemental concentrations were consistent across different surface locations on each uranium grain. However, inter-granular comparison revealed large heterogeneity between different grains of the same sample. By comparing the distribution of elemental concentrations across the particle populations, we were able to correctly identify a manufacturing process involving wet chemistry, rather than a dry mixing of two powders to give an overall chemical average. In conclusion, this demonstrates the utility of LIBS as a large-scale single particle analysis tool for nuclear forensics.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear forensic analysis on uranium ore concentrates: A multi-laboratory intercomparison study

A collaboration between the United States and Japan performed nuclear forensic analyses on a set of 7 uranium ore concentrate (UOC) samples with known origins to improve methodologies and best practices in the field. Overall, good agreement between the 4 participating laboratories was achieved for uranium assay, uranium isotope composition, strontium isotope composition, and trace element analysis. In conclusion, the combination of these four signatures is sufficient to distinguish the different origins among these studied UOCs.

and nuclear chemistry↗

Sample screening of uranium ore concentrates using portable spectrophotometers: investigating the correlation between visible colors and chemical signatures

A research collaboration between the Japan Atomic Energy Agency and the Department of Energy’s National Nuclear Security Administration examined nuclear forensic signatures and analytical methods for tracing the origins of uranium ore concentrates (UOCs). Here, this study focuses on utilizing portable spectrophotometers capable of reflectance measurements in the visible light spectrum as a potential rapid screening tool for nuclear forensics analysis. Unlike laboratory-based near-infrared spectroscopy or digital image analysis, this research investigated the potential to correlate visible color measurements with key nuclear forensics signatures using seven types of UOC samples with known origins and three UOC certified reference materials. Results demonstrated that distinct color groups, quantified using CIELAB values, correlated with major uranium compounds. Furthermore, the findings indicated that trace elements can influence the UOC colors, providing additional insights into material characteristics. Although this approach requires further validation across a broader range of UOC species, this study demonstrated that simple colorimetric analysis using visible spectrophotometry, which does not require complex sample preparation or data processing, can serve as a practical and novel rapid tool for preliminary screening and attribution in nuclear forensics investigations.

and nuclear chemistry↗

Rapid quantification of alcohol production in microorganisms based on nanostructure-initiator mass spectrometry (NIMS)

We described a mass spectrometry-based assay to rapidly quantify the production of primary alcohols directly from cell cultures. This novel assay used the combination of TEMPO-based oxidation chemistry and oxime ligation, followed by product analysis based on Nanostructure-Initiator Mass Spectrometry. This assay enables quantitative monitor both C5 to C18 alcohols as well as glucose and gluconate in the growth medium to support strain characterization and optimization. We find that this assay yields similar results to gas chromatography for isoprenol production but required much less acquisition time per sample. We applied this assay to gain new insights into P. Putida's utilization of alcohols and find that this strain largely could not grow on heptanol and octanol.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparative genomics of Aspergillus nidulans and section Nidulantes

Aspergillus nidulans is an important model organism for eukaryotic biology and the reference for the section Nidulantes in comparative studies. In this study, we de novo sequenced the genomes of 25 species of this section. Whole-genome phylogeny of 34 Aspergillus species and Penicillium chrysogenum clarifies the position of clades inside section Nidulantes. Comparative genomics reveals a high genetic diversity between species with 684 up to 2433 unique protein families. Furthermore, we categorized 2118 secondary metabolite gene clusters (SMGC) into 603 families across Aspergilli, with at least 40 % of the families shared between Nidulantes species. Genetic dereplication of SMGC and subsequent synteny analysis provides evidence for horizontal gene transfer of a SMGC. Proteins that have been investigated in A. nidulans as well as its SMGC families are generally present in the section Nidulantes, supporting its role as model organism. The set of genes encoding plant biomass-related CAZymes is highly conserved in section Nidulantes, while there is remarkable diversity of organization of MAT-loci both within and between the different clades. This study provides a deeper understanding of the genomic conservation and diversity of this section and supports the position of A. nidulans as a reference species for cell biology.

Theobald, Sebastian [Technical University of Denma↗

Process mining for healthcare: Characteristics and challenges

Process mining techniques can be used to analyse business processes using the data logged during their execution. These techniques are leveraged in a wide range of domains, including healthcare, where it focuses mainly on the analysis of diagnostic, treatment, and organisational processes. Despite the huge amount of data generated in hospitals by staff and machinery involved in healthcare processes, there is no evidence of a systematic uptake of process mining beyond targeted case studies in a research context. When developing and using process mining in healthcare, distinguishing characteristics of healthcare processes such as their variability and patient-centred focus require targeted attention. Against this background, the Process-Oriented Data Science in Healthcare Alliance has been established to propagate the research and application of techniques targeting the data-driven improvement of healthcare processes. This paper, an initiative of the alliance, presents the distinguishing characteristics of the healthcare domain that need to be considered to successfully use process mining, as well as open challenges that need to be addressed by the community in the future.

59 BASIC BIOLOGICAL SCIENCES↗

Projected network performance for multiple isotopes using next-generation xenon monitoring systems

Since about 2000 (Bowyer et al., 1998), radioxenon monitoring systems have been under development and testing for the verification of the Comprehensive Nuclear Test-Ban Treaty (CTBT). Operation of the systems since then has resulted in development of a next-generation of systems that are nearly ready for operational deployment. By 2010, the need to screen out civilian sources was well known (Auer et al., 2010; Saey, 2009), and isotopic ratio approaches were soon considered (Kalinowski et al., 2014) to identify specific sources. New generation systems are expected to improve the ability to verify the absence of nuclear tests by using isotopic ratios when multiple isotopes are detected. In this work, thousands of releases were simulated to compute the global detection probability of 131m Xe, 133m Xe, 133 Xe, and 135 Xe at 39 noble gas systems in the International Monitoring System (IMS) for both current and next-generation systems. Three release scenarios are defined at 1 h, 1 d, and 10 d past a 1 kt TNT equivalent 235U explosion event. Multiple cases using from one part in a million to the complete release of the xenon isotopic activity are evaluated for each scenario. Coverage maps and global integrals comparing current and next-generation monitoring systems are presented showing that next-generation noble gas systems will create measurable improvements in the IMS. The global detection probability for 133 Xe is shown to be strong in all scenarios, but only modestly improved by next-generation equipment. However, the detection probability for 131m Xe and 133m Xe increased to about 50% in different scenarios, providing a second detectable isotope for many events. As anticipated from shorter sampling intervals, the expected number of detecting samples roughly doubled and the expected number of detecting stations rose by approximately 50% for all release scenarios. Thus, it might be anticipated that future events would consist of multiple 133 Xe detections and one or more second isotope detections. In conclusion, signals of this nature should increase detection confidence, tighten release location estimates, improve rejection of civilian signals, and lessen the impacts from individual systems being offline for maintenance or repair reasons.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗