The Atmospheric Carbon and Transport (ACT)-America Mission

The Atmospheric Carbon and Transport (ACT)-America NASA Earth Venture Suborbital Mission set out to improve regional atmospheric greenhouse gas (GHG) inversions by exploring the intersection of the strong GHG fluxes and vigorous atmospheric transport that occurs within the midlatitudes. In this study, two research aircraft instrumented with remote and in situ sensors to measure GHG mole fractions, associated trace gases, and atmospheric state variables collected 1,140.7 flight hours of research data, distributed across 305 individual aircraft sorties, coordinated within 121 research flight days, and spanning five 6-week seasonal flight campaigns in the central and eastern United States. Flights sampled 31 synoptic sequences, including fair-weather and frontal conditions, at altitudes ranging from the atmospheric boundary layer to the upper free troposphere. The observations were complemented with global and regional GHG flux and transport model ensembles. We found that midlatitude weather systems contain large spatial gradients in GHG mole fractions, in patterns that were consistent as a function of season and altitude. We attribute these patterns to a combination of regional terrestrial fluxes and inflow from the continental boundaries. These observations, when segregated according to altitude and air mass, provide a variety of quantitative insights into the realism of regional CO 2 and CH 4 fluxes and atmospheric GHG transport realizations. The ACT-America dataset and ensemble modeling methods provide benchmarks for the development of atmospheric inversion systems. As global and regional atmospheric inversions incorporate ACT-America’s findings and methods, we anticipate these systems will produce increasingly accurate and precise subcontinental GHG flux estimates.

54 ENVIRONMENTAL SCIENCES↗

A suite of neutron time-of-flight detectors to measure hot-spot motion in direct-drive inertial confinement fusion experiments on OMEGA

A suite of six neutron time of flight detectors capable of measuring the primary DT neutron energy spectrum has recently been completed on the OMEGA Laser System. The detectors are positioned along multiple quasi-orthogonal lines of sight (LOS’s) in either a stand-alone, collinear, or antipodal configuration. The collinear detector configuration enables one to measure the neutron velocity along the detector LOS independent of the neutron-production history, while the antipodal detector configuration enables one to directly measure of the hot-spot velocity along the detector axis and Gamow velocity shift due to the plasma ion temperature. Using these six measurements of the primary DT neutron energy spectrum, the neutron-averaged hot-spot velocity and Gamow velocity shift of DT fusion neutrons have been measured in cryogenic experiments on OMEGA for the first time. Finally, the detector suite is operable between DT neutron yields of 1 × 10 13 to 2 × 10 14 with an uncertainty of ~14 km/s in the neutron-averaged hot-spot velocity measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an in situ dual-channel thermal desorption gas chromatography instrument for consistent quantification of volatile, intermediate-volatility and semivolatile organic compounds

Abstract. Aerosols are a source of great uncertainty in radiative forcing predictions and have poorly understood health impacts. Most aerosol mass is formed in the atmosphere from reactive gas-phase organic precursors, forming secondary organic aerosol (SOA). Semivolatile organic compounds (SVOCs) (effective saturation concentration, C*, of 10−1–103 µg m−3) comprise a large fraction of organic aerosol, while intermediate-volatility organic compounds (IVOCs) (C* of 103–106 µg m−3) and volatile organic compounds (VOCs) (C* ≥ 106 µg m−3) are gas-phase precursors to SOA and ozone. The Comprehensive Thermal Desorption Aerosol Gas Chromatograph (cTAG) is the first single instrument simultaneously quantitative for a broad range of compound-specific VOCs, IVOCs and SVOCs. cTAG is a two-channel instrument which measures concentrations of C5–C16 alkane-equivalent-volatility VOCs and IVOCs on one channel and C14–C32 SVOCs on the other coupled to a single high-resolution time-of-flight mass spectrometer, achieving consistent quantification across 15 orders of magnitude of vapor pressure. cTAG obtains concentrations hourly and gas–particle partitioning for SVOCs every other hour, enabling observation of the evolution of these species through oxidation and partitioning into the particle phase. Online derivatization for the SVOC channel enables detection of more polar and oxidized species. In this work we present design details and data evaluating key parameters of instrument performance such as I/VOC collector design optimization, linearity and reproducibility of calibration curves obtained using a custom liquid evaporation system for I/VOCs and the effect of an ozone removal filter on instrument performance. Example timelines of precursors with secondary products are shown, and analysis of a subset of compounds detectable by cTAG demonstrates some of the analytical possibilities with this instrument.

54 ENVIRONMENTAL SCIENCES↗

SUDA: A SUrface Dust Analyser for Compositional Mapping of the Galilean Moon Europa

Abstract The Surface Dust Analyser (SUDA) is a mass spectrometer onboard the Europa Clipper mission for investigating the surface composition of the Galilean moon Europa. Atmosphereless planetary moons such as the Galilean satellites are wrapped into a ballistic dust exosphere populated by tiny samples from the moon’s surface produced by impacts of fast micrometeoroids. SUDA will measure the composition of such surface ejecta during close flybys of Europa to obtain key chemical signatures for revealing the satellite’s composition such as organic molecules and salts, history, and geological evolution. Because of their ballistic orbits, detected ejecta can be traced back to the surface with a spatial resolution roughly equal to the instantaneous altitude of the spacecraft. SUDA is a Time-Of-Flight (TOF), reflectron-type impact mass spectrometer, optimized for a high mass resolution which only weakly depends on the impact location. The instrument will measure the mass, speed, charge, elemental, molecular, and isotopic composition of impacting grains. The instrument’s small size of$268 ~\mathrm {mm} \times 250 ~\mathrm {mm} \times 171$ 268 mm × 250 mm × 171 $~\mathrm {mm}$ mm , radiation-hard design, and rather large sensitive area of 220 cm 2 matches well the challenging demands of the Clipper mission.

Astronomy & Astrophysics↗

Tools to perform data reduction of time-of-flight data taken on BL4A (MagRef)—a Jupyter notebook approach

A collection of modules or tools to produce reflectivity profiles from data acquired with unpolarized and polarized neutron beams using the BL4A (MagRef) instrument at the Spallation Neutron Source. The Jupyter notebook approach offers transparency to the user on what is done with the data, and once the event mode data are stored as NumPy binary files empowers the user to perform the steps from their own laptop without the need for Mantid. The notebook offers two options for background subtraction, applies corrections for the wavelength dependence of the polarizer and flipper efficiencies, accounts for Zeeman energy splitting of the spin-flip channels, Qz-bins the data along contours of constant Qz, propagates errors and writes results in text format suitable for analysis with tools such as GenX.

Fitzsimmons, Michael [Oak Ridge Associated Univ., ↗

Aerodynamic diameter particle size distributions for the AGINSGP experiment

Aerodynamic size distributions were collected by the APS 3321 (TSI Inc.) in the guest instrument facility at ARM’s Southern Great Plains site, during the AGINSGP field campaign. The APS accelerates particle through an orifice and uses two overlapping laser beams to measure the time-of-flights for particles. The aerodynamic diameter controls how quickly a particle will accelerate, with larger particles accelerating more slowly due to their greater inertia. The APS measures particle size distributions from 0.542 to 19.81 µm. Size distributions are averaged to their 1 minute averages. Air was drawn into the GIF through custom aluminum stack inlets (6” inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8” or 1/4" copper lines, depending on sample flow of the instrument.

54 ENVIRONMENTAL SCIENCES↗

The Analysis and Support for LANL Technology Testbed: High Altitude Balloon Gondola and Orion Eagle Gamma Ray Detection Instrument

The Analysis and Support for LANL Technology Testbed: High Altitude Balloon Gondola and Orion Eagle Gamma-Ray Detection Instrument is a project where Los Alamos National Laboratory (LANL), in conjunction with the University of Michigan, are looking into gamma-ray detection in a space-like environment. The purpose of the detection is to work on instruments that can assist with planetary exploration and nuclear deterrents using a High-Altitude Balloon (HAB). For this paper, the main focus is on the mechanical aspects related to the structural analysis of the gondola. It is vital to understand the structural analysis because it helps determine if the gondola can survive the changes in the environment and the different forces or shocks that it will experience when the parachute is deployed and at landing. Additionally, NASA's Balloon Program Office (BPO) has specific requirements to meet to achieve flight certifications. Part of those certifications requires the gondola to simulate different scenarios at specific conditions with various forces applied and orientations. Therefore, it is necessary to adjust the calculations of each method and the force applied to get the right results. Once that is done, the information is inputted into the structural analysis modeling system. The system will aid the mechanical team in assessing the conditions of the gondola at each scenario and determine its margin of safety. After the gondola and instrument are certified, the payload will be able to fly. The HAB and payload are launched from NASA's Columbia Scientific Balloon Facility (CSBF) at Fort Sumner, NM. The official flight was on September 26th, 2021.

42 ENGINEERING↗

High Elevation Radiation Array (HERA) detectors for airborne thunderstorm investigations

A high-energy atmospheric physics phenomenon, referred to as a terrestrial gamma ray flash (TGF), is associated with lightning and produces large bursts of energetic photon radiation. TGFs will be investigated using a suite of gamma-ray instruments designed and constructed to fly on ten United States Air Force (USAF) WC-130J Hurricane Hunter aircraft as part of an aircrew ionization study led by the Air Force Institute of Technology (AFIT) and the United States Air Force School of Aerospace Medicine (USAFSAM), in cooperation with the 53rd Weather Reconnaissance Squadron (WRS). Each instrument consists of one NaI and one plastic detector, a GPS timing device, and an instrument computer that performs data acquisition. High Elevation Radiation Array (HERA) detectors will be employed to maximize the chances of observing TGFs near their source and to gain a better understanding of their origin, mechanism, ubiquity, and to assess potential hazards posed to military and commercial aircrew and passengers. The HERA program, deployed on 10 separate Air Force aircraft over a multi-year campaign, will result in thousands of observational flight hours and be the largest concerted effort to date to observe TGFs in situ through aircraft observations. In this paper, we give an overview of the scientific goals of this campaign and how the HERA instruments have been designed to meet those goals. Here, we include a detailed description of the HERA instrument, along with mass model and signal processing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FIB-ToF-SIMS characterization of irradiated U-10Zr

Post-irradiation examination (PIE) is critical for the performance assessment and qualification of nuclear fuels. Secondary ion mass spectrometry (SIMS) is a powerful materials characterization technique that allows for elemental and isotopic mapping with a depth resolution greater than EDS and EPMA. However, it has not yet been applied to PIE of metallic nuclear fuel. Here, in this work, we characterize an fast neutron spectrum irradiated U-10Zr fuel sample using a time-of-flight SIMS (ToF-SIMS) system connected to a FIB/SEM system, which allows for flexible sample analysis compared to a dedicated ToF-SIMS instrument. Analysis of the resulting hyperspectral micrograph data was aided by the development of an unsupervised machine learning (ML) algorithm that iterates on existing methods to segment the 3D micrographic datasets based on the similarity of mass spectra. The results showed that the FIB-ToF-SIMS instrument was potentially capable of spatially resolving closed fission gas bubbles in 3D by continued ion sputtering of the analyzed volume. Additionally, the ML algorithm proved useful in revealing the chemical segregation of light fission products (those with an atomic mass between approximately 85–105 amu, such as ruthenium and rhodium) plus matrix zirconium, heavy fission products (those with an atomic mass between approximately 135–150 amu, such as the lanthanides) and uranium. Future studies are planned to conduct FIB-ToF-SIMS analysis on more irradiated U-Zr samples to study the constituent redistribution.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The CLAS12 Backward Angle Neutron Detector (BAND)

The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of 155° to 175°, with momenta between 200 and 600 MeV$/c_0$. It is positioned 3-m upstream of the target, consists of 18 rows and 5 layers of 7.2-cm by 7.2-cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2-cm thick lead wall followed by a 2-cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than 250 ps (150 ps) for energy depositions above 2 MeV (5 MeV). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. We report the time resolution results in a neutron momentum reconstruction resolution, $δp/p$ < 1.5% for neutron momentum 200 ≤ $p$ ≤ 600 MeV/c. Final performance of the BAND with CLAS12 is shown, including electron–neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mini Micropulse Lidar measurements in vertical and scanning modes

The Atmospheric Radiation Measurement (ARM) program operates ten Sigma Space (currently Droplet Measurement Technologies/DMT) micropulse lidar systems (MPL-4B-IDS/POL-FS series), which detect the backscattered light in two orthogonal linear polarization channels allowing to distinguish between spherical (e.g. water) and non-spherical (e.g. ice) scattering particles. The ARM MPLs have been providing valuable measurements to the aerosol and cloud research community for well over a decade. DMT&rsquo;s Mini-Micropulse lidar (MiniMPL) is a compact version of the standard MPL. It reduces the power-aperture product to minimize cost, size, weight, power requirements and has all the electronics integrated with optics in a single box. Although as a result, it has a lower detection range than the MPL, limiting the measurements to the troposphere, its performance is promised to match that of the standard MPL within the troposphere. The MiniMPL weighs 13 kg, and the complete system, consisting of an optical transceiver and a laptop running the data acquisition and post-processing software, fits in a storm case, allowing its transport on domestic or international flights. This can be especially valuable for short field campaigns or Intensive Operational Periods, where time is of the essence when replacing a faulty instrument. In addition, the scanning polarization lidar capability (MiniMPL-SCAN option) could be of great interest for satisfying ARM measurement needs for certain research topics related to clouds and precipitation. To evaluate its full potential in comparison with co-located remote sensing instruments including the ARM MPL-4B-IDS/POL-FS at SGP, a miniMPL was hosted at the ARM Southern Great Plains (SGP) mega-site in 2020 for approximately 3 months. During this time the miniMPL was tested in both vertical sampling and scanning modes.

54 ENVIRONMENTAL SCIENCES↗

TBS FROST Data from 2023 at SGP C1

The FROST provides chemical analysis of four time-resolved sorbent samples on a LECO GCxGC Bench Time of Flight Mass Spectrometer, using a Gerstel MPS Thermal Desorption System. Samples collected via FROST can be analyzed on one of two Sandia National Laboratories' instruments. One instrument will provide ultra-high mass spectrometer resolution (up to four decimal points or m/z data) and can be used for identification of true unknowns. Data can include suspected formulas of species not included in any current mass spectra database. This instrument also has a low limit of detection of known species (tens of femtogram range). The second instrument can provide an order of magnitude lower limits of detection (into the single-digit femtogram range) for known species currently in mass spectra databases. This system is also more resilient to environmental samples that contain higher levels of moisture.

54 ENVIRONMENTAL SCIENCES↗

Turbulent Parameters by airborne measurements over BNF in March 2025

The original data were collected during the AAF Engineering Flights (AEF2025) in the vicinity of the ARM Bankhead National Forest (BNF) Atmospheric Observatory (https://www.arm.gov/capabilities/observatories/bnf ) in northwestern Alabama in March 2025. The ARM Aerial Facility ArcticShark uncrewed aerial system (UAS, https://www.arm.gov/capabilities/observatories/aaf/uas) was based at the public-use airport of Posey Field, Alabama (FAA LID: 1M4, 34.28027778° N, 87.60055556° W, 283m MSL) from March 10 through March 24, 2025. The ArcticShark UAS performed nine flights, including eight research flights over the AMF3 (BNF Main Site) and Supplemental Facilities to measure atmospheric state, turbulence, surface IR temperature and imagery, and aerosol number concentration and size distribution. The current data set presents a collection of turbulent parameters in the atmospheric boundary layer or lower free troposphere based on airborne measurement throughout the field campaign. The primary instruments used to create the current data set were the Aircraft Integrated Meteorological Measurement System (AIMMS-30) and the fine-wire thermocouple probe.

Atmosphere↗

Plastic scintillation detectors for time-of-flight mass measurements

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting Cyclotron Laboratory (NSCL) by increasing the number of photomultiplier tubes that read out their light signals to four per detector, and characterized them in a test experiment with 48 Ca beam at the NSCL. The new detectors achieved a time resolution (σ) of 7.5 ps. We systematically investigated different factors that affect their timing performance. In addition, we evaluated the ability of positioning the hitting points on the scintillator using the timing information and obtained a resolution (σ) below 1 mm for well-defined beam spots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Texture measurements on quartz single crystals to validate coordinate systems for neutron time-of-flight texture analysis

In crystallographic texture analysis, ensuring that sample directions are preserved from experiment to the resulting orientation distribution is crucial to obtain physical meaning from diffraction data. This work details a procedure to ensure instrument and sample coordinates are consistent when analyzing diffraction data with a Rietveld refinement using the texture analysis software MAUD . A quartz crystal is measured on the HIPPO diffractometer at Los Alamos National Laboratory for this purpose. The methods described here can be applied to any diffraction instrument measuring orientation distributions in polycrystalline materials.

36 MATERIALS SCIENCE↗

BoxScore - A real-time beam-diagnosis program for the CAEN digitizer x730 series

BoxScore is a real-time beam diagnosis and monitoring program for the CAEN x730 series digitizer, developed for the ATLAS in-flight system at Argonne National Laboratory. The CAEN x730 series digitizer, with built-in Digital Pulse Processing for the Pulse-Height-Analysis, digitizes the input signal in real-time and processes it using a trapezoidal filter. BoxScore reads the digitizer’s buffer directly, builds and saves events to local files, plots histograms for particle identification, and outputs the rates of selected isotopes every second. Implementation of BoxScore has shortened the time needed for in-flight beam-tuning and has potential applications for other nuclear physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 Forward Time-of-Flight system

The Forward Time-of-Flight system for the large-acceptance CLAS12 spectrometer in Hall B at the Thomas Jefferson National Accelerator Facility is described. The system is positioned at distances in the range from 6.2 m to 7.2 m from the beam–target interaction point and spans laboratory polar angles from 5 deg → 45 deg and nearly the full azimuth. The system consists of 540 individual scintillation counters with double-ended readout that range in length from 17 cm to 426 cm of discrete widths of 6 cm, 15 cm, and 22 cm, and of discrete thicknesses of 5 cm and 6 cm. We see the effective counter time resolution for passing charged particles varies from 50 ps for the shortest counters at small angles to 200 ps for the longest counters at large angles. The detectors are part of the forward-angle particle identification system for CLAS12 during offline event reconstruction and are a component of the online data acquisition trigger to select final state event topologies with forward-going charged particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Versatile system for ion energy measurements generated by pulsed laser ionization: Insights into electron-ion dynamics

Ion energy distributions generated by pulsed laser interactions with materials are essential for applications ranging from materials science to oncology. Ion energy characterization is particularly important for an emerging mass spectrometry technique called virtual-slit cycloidal mass spectrometry (VS-CMS). The ion energy distribution influences the design and performance of VS-CMS instruments, as well as the efficacy of laser-driven ionization methods in various fields. Several established techniques, including the retarding potential method, time-of-flight (TOF) analysis, and electrostatic energy analyzers, have been employed to measure ion energy distributions. The wide range of ion energies reported highlights the strong dependence of ion energy on laser parameters, target materials, and experimental conditions, as well as the necessity of making independent measurements of the ion energy distribution for specific laser systems and materials. This paper presents the design and characterization of a simple TOF-based apparatus for measuring ion energy distributions from pulsed laser ionization without external fields. This approach minimizes perturbation of electron-ion dynamics and enables simultaneous energy measurements at multiple spatial positions. Here, the apparatus was tested using a nanosecond pulsed Nd:YAG laser operating at 1064 nm, 532 nm, and 266 nm on solid copper sheets at various laser fluences. Simultaneous measurements at different distances provide new insights into ion-electron interactions post-ionization and demonstrate the influence of laser wavelength and fluence on ion energy distributions.