Ion thruster diagnostics using spectral line amplitudes.

The optical radiation from the plasma discharge of an electron bombardment mercury ion thruster was investigated. This work extends and refines earlier measurements, correcting certain ambiguities that arose in the analysis of line amplitudes. Using the measured ratio of the Hg I line amplitude at 3655 A to that at 3650 A, a theory incorporating a bimodal electron distribution (Maxwell electrons plus primary electrons) was used to obtain the average electron temperature and primary electron fraction in the thruster ion chamber. The electron temperature ranged from about 1.2 eV to 6.6 eV; whereas the primary electron fraction varied from zero percent to about 5 percent. These values depended upon the discharge voltage and the radial location of the measurement. The percentage of doubly ionized mercury produced in the chamber was also determined as a function of discharge voltage.

Milder, N. L.↗

A 9700-hour durability test of a five centimeter diameter ion thruster

A modified Hughes SIT-5 thruster was life-tested at the Lewis Research Center. The final 2700 hours of the test are described with a charted history of thruster operating parameters and off-normal events. Performance and operating characteristics were nearly constant throughout the test except for neutralizer heater power requirements and accelerator drain current. A post-shutdown inspection revealed sputter erosion of ion chamber components and component flaking of sputtered metal. Several flakes caused beamlet divergence and anomalous grid erosion, causing the test to be terminated. All sputter erosion sources were identified.

Nakanishi, S.↗

Soft X-ray flare spectra

Large solar flares produce intense soft X-ray emission, indicating the existence of high temperature plasmas that coexist in time with the plasmas responsible for the normally observed brightenings in H-alpha. The time behavior of the X-ray flux, as revealed, for example, by ion chamber detectors on the series of Solrad monitoring satellites, appears to roughly mimic the intensity-time behavior of the H-alpha flare, insofar as start times, times of maximum flux, and approximate decay times are concerned. In recent years, soft X-ray spectra of both active regions and solar flares have been obtained by instruments flown on spacecraft such as the Orbiting Solar Observatory (OSO) series. The disbursing elements used were Bragg crystals, and in the 8 Angstrom region the resolution is typically approximately 1200. This paper discusses the observed characteristics of X-ray flare spectra and spectroscopic diagnostics for determining electron temperatures, electron densities, and departures from ionization equilibrium within the soft X-ray emitting plasma.

Doschek, G. A.↗

Study of blood forming organ dose as a function of proton environment

It is demonstrated that a dosimeter which consists of four ion chambers, each with different wall thickness, is able to reproduce the BFO dose with reasonable accuracy. This generalized dosimetric system is only slightly more complex than dosimeters in current use. This preliminary development had two built-in assumptions; the isotropicity of the radiation and the neglect of nuclear reaction effects. Only the nuclear reaction effects have been calculated.

Khandelwal, G. S.↗

A 9700-hour durability test of a five centimeter diameter ion thruster

A modified Hughes SIT-5 thrustor has been life-tested at the Lewis Research Center. The final 2700 hours of the test are described with a charted history of thrustor operating parameters and off-normal events. Performance and operating characteristics were nearly constant throughout the test except for neutralizer heater power requirements and accelerator drain current. A post-shutdown inspection revealed sputter erosion of ion chamber components and component flaking of sputtered metal. Several flakes caused beamlet divergence and anomalous grid erosion, causing the test to be terminated. All sputter erosion sources have been identified and promising sputter resistant components are currently being evaluated.

Nakanishi, S.↗

The specific light output of cesium iodide crystals

Large area ion chambers for a high energy cosmic ray experiment, scintillating plastic fibers as light pipes for a cosmic ray hodoscope, and an evaluation of clad scintillating light pipes were considered.

Gregory, J. C.↗

Calibration of the active radiation detector for Spacelab-One

The flight models of the active radiation detector (ARD) for the ENV-01 environmental monitor were calibrated using gamma radiation. Measured sensitivities of the ion chambers were 6.1 + or - 0.3 micron rad per count for ARD S/N1, and 10.4 + or - 0.5 micron rad per count for ARD S/N2. Both were linear over the measured range 0.10 to 500 m/rad hour. The particle counters (proportional counters) were set to respond to approximately 85% of minimum ionizing particles of unit charge passing through them. These counters were also calibrated in the gamma field.

Source record↗

Elemental abundances of cosmic rays with Z33 as measured on HEAO-3

The Heavy Nuclei Experiment on HEAO-3 uses a combination of ion chambers and a Cerenkov counter. During analysis, each particle is assigned two parameters Z sub c and Z sub l proportion signal is double valued, a unique assignment of particle charge, Z, is not possible in general. Previous work was limited to particles of either high rigidity or low energy, for which a unique charge assignment was possible, although those subsets contain less than 50% of the total number of particles observed. The use of the maximum likelihood technique to determine abundances for the complete data set from approximately 1.5 to approximately 80 GeV/amu is studied.

Newport, B. J.↗

Lead, platinum, and other heavy elements in the primary cosmic radiation: HEAO-3 results ssc wg032961 cb553097

An observation of the abundances of cosmic-ray lead and platinum-group nuclei using data from the HEAO-3 Heavy Nuclei Experiment (HNE) which consisted of ion chambers mounted on both sides of a plastic Cerenkov counter is reported. Further analysis with more stringent selections, inclusion of additional data, and a calibration at the LBL Bevalac, have allowed obtaining the abundance ratio of lead and the platinum group of elements for particles that had a cutoff rigidity R sub c 5 GV.

Waddington, C. J.↗

Elemental abundances of cosmic rays with Z 33 as measured on HEAO-3

The Heavy Nuclei Experiment on (HEAO-3) high energy astronomy observatory 3 uses a combination of ion chambers and a Cerenkov counter. During analysis, each particle is assigned two parameters, Z sub c and Z sub i, proportional to the square roots of the Cerenkov and mean ionization signals respectively. Because the ionization signal is double valued, a unique assignment of particle charge, Z, is not possible in general. Previous work was limited to particles of either high rigidity or low energy, for which a unique charge assignment was possible, although those subsets contain less than 50% of the total number of particles observed. The maximum likelihood technique was used to determine abundances for the complete data set from approx. 1.5 to approx. 80 GeV/amu.

Newport, B. J.↗

Effect of the Mott cross section on charge identification in the HEAO-3 Heavy Cosmic Ray Experiment

Corrections to the Z-squared dependence of ion chamber and Cherenkov response due to the Mott cross section are calculated for the HEAO-3 Heavy Cosmic Ray Experiment. The effect of the production and escape of high energy secondary electrons on detector response is accounted for by numerical calculations. These secondary electron effects are shown to influence the size of the non Z-squared effects and thus affect the charge assignments and detector resolution. The Bloch and relativistic Bloch corrections are not included in the results presented here but may be combined with the Mott corrections when the Bloch corrections are properly evaluated.

Derrickson, J. H.↗

Lead, platinum and other heavy elements in the primary cosmic radiation: HEAO-3 results

An observation of the abundances of cosmic-ray lead and platinum-group nuclei using data from the HEAO-3 Heavy Nuclei Experiment (HNE) which consisted of ion chambers mounted on both sides of a plastic Cherenkov counter (Binns et al., 1981) is reported. Further analysis with more stringent selections, inclusion of additional data, and a calibration at the LBL Bevalac, have allowed the determination of the abundance ratio of lead and the platinum group of elements for particles that had a cutoff rigidity R(c) 5 GV. The observed ratio for Pb/Pt is distinctly lower than that predicted by any of the standard models for cosmic ray sources. It is possible that the difference is not an indication that the cosmic ray source composition is greatly different from that of the solar system, but rather that there is less Pb in the solar system and in the r-process than is assumed in the standard models.

Waddington, C. J.↗

Precision measurements of photoabsorption cross sections of Ar, Kr, Xe, and selected molecules at 58.4, 73.6, and 74.4 nm

Absolute absorption cross sections have been measured for the rare gases at 58.43, 73.59, and 74.37 nm with an accuracy of + or - 0.8 percent. For the molecules H2, N2, O2, CO, N2O, CO2, and CH4, precision measurements were made at 58.43 nm with an accuracy of + or - 0.8 percent. Molecular absorption cross sections are also reported at 73.59 and 74.37 nm. However, in the vicinity of these wavelengths most molecules exhibit considerable structure, and cross sections measured at these wavelengths may depend on the widths and the amounts of self-reversal of these resonance lines. A detailed discussion is given of the systematic errors encountered with the double-ion chamber used in the cross-sectional measurements. Details are also given of precision pressure measurements.

Samson, James A. R.↗

Multilayer and grazing incidence X-ray/EUV optics; Proceedings of the Meeting, San Diego, CA, July 22-24, 1991

The present conference discusses the Advanced X-ray Astrophysics Facility (AXAF) calibration by means of synchrotron radiation and its X-ray reflectivity, X-ray scattering measurements from thin-foil X-ray mirrors, lobster-eye X-ray optics using microchannel plates, space-based interferometry at EUV and soft X-ray wavelengths, a water-window imaging X-ray telescope, a graded d-spacing multilayer telescope for high energy X-ray astronomy, photographic films for the multispectral solar telescope array, a soft X-ray ion chamber, and the development of hard X-ray optics. Also discussed are X-ray spectroscopy with multilayered optics, a slit aperture for monitoring X-ray experiments, an objective double-crystal spectrometer, a Ly-alpha coronagraph/polarimeter, tungsten/boron nitride multilayers for XUV optical applications, the evaluation of reflectors for soft X-ray optics, the manufacture of elastically bent crystals and multilayer mirrors, and selective photodevices for the VUV.

Hoover, Richard B.↗

Hale cycle effects in cosmic ray east-west anisotropy and interplanetary magnetic field

We have reanalyzed diurnal anisotropy data obtained with the shielded ion chamber (IC) at Cheltenham/Fredericksburg and the neutron monitor (NM) at Swarthmore/Newark. IC data are for the 1936-1977 period and NM data are for the 1965-1988 period. We have corrected IC data for the diurnal temperature effect. Application of this correction results in a better agreement between IC and other data sets, thereby making it possible to study the long-term changes in the diurnal anisotropy using IC data. The behavior of the annual mean east-west anisotropy is studied for 53 years of observations. The period encompasses more than two solar magnetic (Hale) cycles. Its amplitude undergoes the expected 11 and 22 year variations, with the largest changes occurring near solar activity minima. Moreover, the data indicate the presence of the subsidiary maxima for the entire 53-year period, following the solar polar field reversals, during the declining phases of activity cycles when high-speed solar wind streams are present in the heliosphere. The data suggest that the amplitude of the subsidiary maximum is large when the solar polar magnetic field points toward the sun in the Northern Hemisphere, and radial anisotropy is absent.

Ahluwalia, H. S.↗

Long-term modulation of galactic cosmic radiation and its model for space exploration

As the human exploration of space has received new attention in the United States, studies find that exposure to space radiation could adversely impact the mission design. Galactic Cosmic Radiation (GCR), with its very wide range of charges and energies, is particularly important for a mission to Mars, because it imposes a stiff mass penalty for spacecraft shielding. Dose equivalent versus shielding thickness calculations, show a rapid initial drop on exposure with thickness, but an asymptotic behavior at a higher shielding thickness. Uncertainties in the radiobiology are largely unknown. For a fixed radiation risk, this leads to large uncertainties in shielding thickness for small uncertainties in estimated dose. In this paper we investigate the application of steady-state, spherically-symmetric diffusion-convection theory of solar modulation to individual measurements of differential energy spectra from 1954 to 1989 in order to estimate the diffusion coefficient, kappa(r,t), as a function of time. We have correlated the diffusion coefficient to the Climax neutron monitor rates and show that, if the diffusion coefficient can be separated into independent functions of space and time: kappa(r,t)=K(t) k(sub 0) beta Pk(sub 1) (r), where beta is the particle velocity and P the rigidity, then (i) The time dependent quantity 1/K(t), which is proportional to the deceleration potential, phi(r,t), is linearly related to the Climax neutron monitor counting rate. (ii) The coefficients obtained from hydrogen or helium intensity measurements are the same. (iii) There are different correlation functions for odd and even solar cycles. (iv) The correlation function for the Climax neutron monitor counting rate for given time, t, can be used to estimate mean deceleration parameter phi(t) to within +/- 15% with 90% confidence. We have shown that k(r,t) determined from hydrogen and/or helium data, can be used to fit the oxygen and iron differential energy spectra with a root mean square error of about +/- 10%, and essentially independent of the particle charge or energy. We have also examined the ion chamber and C-14 measurements which allow the analysis to be extended from the year 1906 to 1990. Using this model we have defined reference GCR spectra at solar minimum and solar maximum. These can be used for space exploration studies and provide a quantitative estimate of the error in dose due to changes in GCR intensities.

Badhwan, G. D.↗

Assay of the Martian Regolith with Neutrons

Different aspects of assaying Martian regolith using neutrons have been investigated. The epithermal portion of moderated neutrons spectra is dramatically effected by the presence of hydrogen (usually in the form of water). A simple analytic formula has been derived to describe the amplitude of this portion of the neutron spectrum as a function of water concentration. Several demonstration experiments have been performed and modeled with a Monte Carlo code. Results of these experiments generally agreed with the calculations to within 20%. In addition to He-3 detectors, lithium-glass scintillators and U-238 fission ion chambers were investigated to determine their applicability to space experiments.

Drake, Darrell M.↗