Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The Reduction of TED in Ion Implanted Silicon

The leading challenge in the continued scaling of junctions made by ion implantation and annealing is the control of the undesired transient enhanced diffusion (TED) effect. Spike annealing has been used as a means to reduce this effect and has proven successful in previous nodes. The peak temperature in this process is typically 1050 deg. C and the time spent within 50 deg. C of the peak is of the order of 1.5 seconds. As technology advances along the future scaling roadmap, further reduction or elimination of the enhanced diffusion effect is necessary. We have shown that raising the peak temperature to 1175 deg. C or more and reduction of the anneal time at peak temperature to less than a millisecond is effective in eliminating enhanced diffusion. We show that it is possible to employ a sequence of millisecond anneal followed by spike anneal to obtain profiles that do not exhibit gradient degradation at the junction and have junction depth and sheet resistance appropriate to the needs of future technology nodes. We have implemented millisecond annealing using a carbon dioxide laser to support high-volume manufacturing of 65 nm microprocessors and system-on-chip products. We further show how the use of molecular ion implantation to produce amorphousness followed by laser annealing to produce solid phase epitaxial regrowth results in junctions that meet the shallow depth and abruptness requirements of the 32 nm node.

36 MATERIALS SCIENCE↗

The Development and Evolution of Ion Implanters in the Semiconductor Industry

By the end of the 1960's, the development of ion beam systems for isotope separation and materials research had reached the stage at which knowledge bases in the areas of ion beam formation and transport and the physics of atomic collisions in solids made it practical to consider the use of ion implantation as a means of modifying the near surface properties of solid materials. The beam currents and energies available made the technique particularly compatible with the doping requirements of the silicon devices being produced at that time. However, incorporation of the technique into a high volume manufacturing environment required the immediate development of new target handling facilities and improvements in machine reliability. While the manner in which ion implanters have evolved over the past forty years has continued to be dictated by the changing demands of the silicon processing industry, the dramatic reduction in transistor size and the increase in integrated circuit complexity have had significant implications for the qualities of the ion beams themselves, particularly in high current, ultra-low energy applications. Since the first commercial implanters were introduced, highly developed medium current, high current and high energy machines have evolved. In the medium current and high energy sectors, well understood ion optical principles have enabled ingenious and highly effective beam formation and transport systems to be designed. As these machines evolved, extensive studies of the implanted material using ion beam based techniques such as Rutherford backscattering and channelling provided a growing understanding of the fundamental radiation damage and annealing processes that are inevitably associated with the implantation process. For high current machines, particularly those operating in the so-called eV implantation range, beam formation and transport processes become considerably more complex and established ion optical design principles must be combined with detailed considerations of the roles of emittance, space charge and beam plasma characteristics if beams compatible with production worthy ultra-shallow junction formation are to be obtained. For these shallow, high dose implants, the proximity of the surface has a significant effect on the radiation damage build-up and annealing processes. To develop an understanding of the physics of some aspects of these processes, high depth resolution analytical techniques such as medium energy ion scattering have been applied. In the present review, the process based evolution of ion implantation equipment is discussed alongside a consideration of the contribution made by the growth in understanding of the physics of both the beams themselves and the ion collection and radiation damage processes occurring in the implanted silicon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of plasma distribution in electron-focused electric field enhanced glow discharge plasma immersion ion implantation

In enhanced glow discharge plasma immersion ion implantation (EGDPIII) that involves a small pointed anode and large area tabular cathode, the high negative substrate bias not only acts as the plasma producer but also supplies the implantation voltage. Consequently, an electric field is created to focus the electrons and the electron-focusing field enhances the glow discharge process. In this work, the plasma distribution is measured using a Langmuir probe to obtain the plasma density. Numerical interpolation is performed to obtain the plasma density distribution throughout the entire discharge region. The effects of different distances between the anode and cathode on the glow discharge characteristics and the influence of the plasma electron density are also evaluated. Our results experimentally verify the electron-focusing phenomenon and suggest optimal processing windows for enhanced ionization rates and efficiency in EGDPIII.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Inhibitive formation of nanocavities by introduction of Si atoms in Ge nanocrystals produced by ion implantation

Germanium nanocrystals (Ge-nc) were successfully synthesized by co-implantation of Si and Ge ions into a SiO{sub 2} film thermally grown on (100) Si substrate and fused silica (pure SiO{sub 2}), respectively, followed by subsequent annealing at 1150 °C for 1 h. Transmission electron microscopy (TEM) examinations show that nanocavities only exist in the fused silica sample but not in the SiO{sub 2} film on a Si substrate. From the analysis of the high-resolution TEM images and electron energy-loss spectroscopy spectra, it is revealed that the absence of nanocavities in the SiO{sub 2} film/Si substrate is attributed to the presence of Si atoms inside the formed Ge-nc. Because the energy of Si-Ge bonds (301 kJ·mol{sup −1}) are greater than that of Ge-Ge bonds (264 kJ·mol{sup −1}), the introduction of the Si-Ge bonds inside the Ge-nc can inhibit the diffusion of Ge from the Ge-nc during the annealing process. However, for the fused silica sample, no crystalline Si-Ge bonds are detected within the Ge-nc, where strong Ge outdiffusion effects produce a great number of nanocavities. Our results can shed light on the formation mechanism of nanocavities and provide a good way to avoid nanocavities during the process of ion implantation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects of long pulse width and high pulsing frequency on surface superhydrophobicity of polytetrafluoroethylene in quasi-direct-current plasma immersion ion implantation

Long pulse, high frequency quasi-direct-current (dc) oxygen plasma immersion ion implantation (PIII) is utilized to create a superhydrophobic polytetrafluoroethylene (PTFE) surface with a water contact angle of over 150 deg. This technique allows the use of a high duty cycle without deleterious effects such as extensive sample heating encountered in conventional PIII. Scanning electron microscopy images review submicrometer-nanometer structures on the PTFE surface after long pulse, high frequency PIII indicative of ion implantation. On the other hand, plasma modification is the dominant effect in short pulse, low frequency PIII. Quasi-dc PIII is demonstrated to offer adjustable synergistic plasma and ion beam effects.

36 MATERIALS SCIENCE↗

Performance Enhancement of PFET Planar Devices by Plasma Immersion Ion Implantation (P3I)

A study of doping the pMOS Lightly Doped Drain (LDD) by Plasma Immersion Ion Implantation (P3i) with BF3 is presented which demonstrates a better transistor performance compared to standard beam line Ion Implantation (I/I). The benefit of P3i comes from the broad angular distribution of the impinging ions thereby doping the poly-silicon gate sidewall as well. Gate capacitance of short channel devices has been measured and clearly shows this improvement. This model is clearly supported by high resolution 2D-carrier profiles using Scanning Spreading Resistance Microscopy (SSRM) which shows this gate sidewall doping. The broad angular distribution also implies a smaller directional sensitivity (to for instance the detailed gate edge shape) and leads to devices which are perfectly balanced, when Source and Drain electrode are switched.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Critical issues in the formation of quantum computer test structures by ion implantation

The formation of quantum computer test structures in silicon by ion implantation enables the characterization of spin readout mechanisms with ensembles of dopant atoms and the development of single atom devices. We briefly review recent results in the characterization of spin dependent transport and single ion doping and then discuss the diffusion and segregation behaviour of phosphorus, antimony and bismuth ions from low fluence, low energy implantations as characterized through depth profiling by secondary ion mass spectrometry (SIMS). Both phosphorus and bismuth are found to segregate to the SiO2/Si interface during activation anneals, while antimony diffusion is found to be minimal. An effect of the ion charge state on the range of antimony ions, 121Sb25+, in SiO2/Si is also discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

N-TiO2 nanoparticles embedded in silica prepared by Ti ion implantation and annealing in nitrogen

Room temperature Ti ion implantation and subsequent thermal annealing in N2 ambience have been used to fabricate the anatase and rutile structured N-doped TiO2 particles embedded in the surface region of fused silica. The Stopping and Range of Ions in Matter (SRIM) code simulation indicates a Gaussian distribution of implanted Ti, with a projected range of 74.4 nm and straggling of 16.5 nm. However, Rutherford backscattering spectrometry and transmission electron microscopy results show a much shallower distribution peaked at ~ 30 nm. Significant sputtering loss of silica substrates has occurred during implantation. Nanoparticles with size of 10-20 nm in diameter have formed after implantation. X-ray photoelectron spectroscopy indicates the coexistence of TiO2 and metallic Ti in the as-implanted samples. Metallic Ti is oxidized to anatase TiO2 after annealing at 600ºC, while rutile TiO2 forms by phase transformation after annealing at 900ºC. At the same time, N-Ti-O, Ti-O-N and/or Ti-N-O linkages have formed in the lattice of TiO2. A red shift of 0.34 eV in the absorption edge is obtained for N-doped anatase TiO2 after annealing at 600 ºC for 6 h. The absorbance increases in the ultraviolet and visible waveband.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Current capabilities and future needs for semiconductor ion implantation (invited)

For many years the largest commercial application for particle accelerators has been semiconductor ion implantation. These tools differ from other accelerators in many respects. In particular they are automated to a very high degree and, in addition to technical performance requirements their success depends on other key metrics including productivity, availability and cost of ownership. These tools also operate with a large variety of species, four orders of magnitude of energy range and five orders of magnitude of dose range. The ion source is a key component of implanters with its own performance metrics that include beam current, lifetime, and materials cost. In this paper, we describe the primary applications for ion implantation and some of the beam line architectures that are used. We describe the ion source that has evolved for this application. Some key future challenges for implanter ion source development are also discussed.

36 MATERIALS SCIENCE↗

Nanoindentation of ion-implanted crystalline germanium

Most indentation studies to date on crystalline germanium (c-Ge) and related covalent semiconductors have been carried out on pristine defect-free material. This paper addresses the paucity of studies on imperfect crystalline materials by exploring the impact of defects generated by ion implantation, prior to contact damage, upon the mechanical properties of c-Ge. Implantation with Ge ions is carried out to generate a layer of highly defective but still-crystalline Ge. Under nanoindentation with a sharp diamond tip, enhanced plasticity is observed relative to pristine material. Characterization by cross-sectional transmission electron microscopy, atomic force microscopy, and load curve analysis shows softening, quasiductile extrusion, and cracking suppression taking place. These changes can be explained by the high density of defects, and dangling bonds in particular, created by ion implantation and revealed by positron-annihilation spectroscopy, and are proportional to the fraction of 'missing bonds' or vacancies in the material. A thermal annealing step at 200 deg. C is sufficient to restore the mechanical response of pristine material, despite incomplete recovery of the original pristine crystal structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Molecular Ion Beam Transportation for Low Energy Ion Implantation

A joint research and development of steady state intense boron ion sources for 100's of electron-volt ion implanters has been in progress for the past five years. Current density limitation associated with extracting and transporting low energy ion beams result in lower beam currents that in turn adversely affects the process throughput. The transport channel with electrostatic lenses for decaborane (B{sub 10}H{sub 14}) and carborane (C{sub 2}B{sub 10}H{sub 12}) ion beams transportation was developed and investigated. The significant increase of ion beam intensity at the beam transport channel output is demonstrated. The transport channel simulation, construction and experimental results of ion beam transportation are presented.

43 PARTICLE ACCELERATORS↗

Combining femtosecond laser annealing and shallow ion implantation for local color center creation in diamond

A common technique for color center creation in wideband gap semiconductors employs ion implantation and a subsequent thermal annealing. In general, this annealing process is conducted in a vacuum oven. Here, we exploit the annealing based on femtosecond laser pulses. For that purpose, we implant fluorine ions at 54 keV and chlorine ions at 74 keV in diamond and perform micrometer precise annealing using focused femtosecond laser pulses at 800 ± (30) nm with different pulse numbers and repetition rates. In this way, we were able to create shallow spots with color centers of varying brightness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ion Implantation with in-situ Patterning for IBC Solar Cells

Interdigitated back-side Contact (IBC) solar cells are the highest efficiency silicon solar cells currently on the market. Unfortunately the cost to produce these solar cells is also very high, due to the large number of processing steps required. Varian believes that only the combination of high efficiency and low cost can meet the stated goal of $1/Wp. The core of this program has been to develop an in-situ patterning capability for an ion implantation system capable of producing patterned doped regions for IBC solar cells. Such a patterning capable ion implanter can reduce the number of process steps required to manufacture IBC cells, and therefore significantly reduce the cost. The present program was organized into three phases. Phase I was to select a patterning approach and determine the patterning requirements for IBC cells. Phase II consists of construction of a Beta ion implantation system containing in-situ patterning capability. Phase III consists of shipping and installation of the ion implant system in a customer factory where it will be tested and proven in a pilot production line.

14 SOLAR ENERGY↗

Use of Xenon Difluoride to Clean Hazardous By-Products in Ion Implanter Source Housings, Turbo Pumps, and Fore-Lines

This paper describes the use of xenon difluoride to clean deposits in the source housing, source turbo pump, and source turbo pump fore-line of ion implanters. Xenon difluoride has previously been shown to be effective in increasing the lifetime of the ion source{sup 1,2} and this paper presents an extension of the technology to other areas within the tool. Process by-products that are deposited in the source housing, turbo pump, and turbo pump fore-line can not only pose productivity issues, in the case of coatings on insulators, but can also be flammable and toxic in the case of deposits formed within the turbo pump and fore-line. The results presented in this paper detail the initial successful examples of using xenon difluoride to clean these deposits.ATMI has shown that xenon difluoride is capable of cleaning an insulator in an ion implanter. Typically during use an insulator will become increasingly coated with deposits that could lead to productivity problems. By introducing xenon difluoride into the source housing the insulator residues were effectively cleaned in-situ, thereby extending the maintenance interval and resulting in significant consumable savings.Similar deposits that form in the turbo pump and fore-line could not only lead to production problems due to turbo pump failure or fore-line build-up, but pose significant health risks during the ex-situ cleaning process. Through internal testing ATMI has shown that xenon difluoride is able to clean phosphorus and germanium deposits located within a turbo pump. Additionally, testing has demonstrated that the turbo pump fore-line can be cleaned in-situ without the need to remove these components, thereby virtually eliminating the possibility of fires. The cleaning reaction progress and by-products were monitored using FTIR spectrometry and thermocouples.In order to efficiently clean the source housing, turbo pump, and turbo pump fore-line xenon difluoride delivery must be optimized. This paper also details a hardware concept that maximizes xenon difluoride delivery and allows the clean to be done in a way that is viable for production ion implanters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Surface Analytics in Support of the Development of Static AutoClean - an In-Situ Cleaning Process for Ion Implanters

Static AutoClean is a new in-situ cleaning strategy in development at ATMI registered that enables increased process efficiency and safety in the ion implantation process. Like the Dynamic in-situ AutoClean technology previously introduced and released by ATMI, Static AutoClean utilizes XeF{sub 2} chemistry for in-situ cleaning of hazardous contaminants and deposits. Static AutoClean, however, is targeted towards cleaning areas of the beam-line (like electrode insulators or source bushings) where cleaning efforts using Dynamic AutoClean may not be sufficient. An explanation of this cleaning strategy and results showing its effectiveness will be presented in a separate paper at this conference (S. Yedave et al.). This paper presents the surface analytical data and methods used to understand and evaluate the effectiveness of Static AutoClean in removing contaminants from surfaces within the source vacuum chamber. Energy Dispersive Spectroscopy (EDS) was used to track the magnitude and spatial distribution of contaminants present on the surfaces within various regions in the source chamber space of an implanter following ion source operation with a commonly used dopant gas. After in-situ cleaning, these same components and surfaces were re-evaluated by EDS to quantitatively determine the reduction in surface contaminants present within the chamber. Learnings regarding the distribution of implant process contamination within the source chamber as well as Static AutoClean's effectiveness in removing it will be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synergistic effect of V/N codoping by ion implantation on the electronic and optical properties of TiO{sub 2}

Performance of the material depends directly on the electronic and energy band structure, to improve the photoactivity of TiO{sub 2} and decrease carrier recombination centers induced by monodoping, the TiO{sub 2} thin film has been modified with V and N codopants by ion implantation for tailing and controlling the electronic structure and energy band structure. Compared to monodopant, codopants of V and N exhibit a synergistic effect in the photoactivity enhancement of TiO{sub 2}. X-ray photoelectron spectroscopy (XPS) studies demonstrate that the implanted V and N ions are introduced into the lattice of TiO{sub 2} through V and N substituting Ti and O, respectively. The electronic structure of V/N codoped TiO{sub 2} was calculated by First-principles calculations based on density-functional theory, the results show the band edges of TiO{sub 2} can be tailored by V and N codopants. UV-vis spectra consistently show the absorption edge of V/N codoped TiO{sub 2} film is widen to visible light region. More importantly, the photoactivity of TiO{sub 2} film has been significantly improved after V/N codoping. The enhanced photocatalytic performance is believed to be due to the V and N codopants induced synergistic effect that not only enhances the absorption of visible light but also promotes the separation of photogenerated electrons and holes in TiO{sub 2}. Besides, there exists an optimum for V/N ions implantation fluence. The capability of improving TiO{sub 2} photoactivity by V/N codoping could open up new opportunities in the development of highly efficient photocatalysts and photoelectrodes for solar energy and environmental applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A fitting algorithm for optimizing ion implantation energies and fluences

In this work we describe a method to automatically generate an ion implantation recipe, a set of energies and fluences, to produce a desired defect density profile in a solid using the fewest required energies. We simulate defect density profiles for a range of ion energies, fit them with an appropriate function, and interpolate to yield defect density profiles at arbitrary ion energies. Given Ν energies, we then optimize a set of Ν energy-fluence pairs to match a given target defect density profile. Finally, we find the minimum Ν such that the error between the target defect density profile and the defect density profile generated by the Ν energy-fluence pairs is less than a given threshold. Inspired by quantum sensing applications with nitrogen-vacancy centers in diamond, we apply our technique to calculate optimal ion implantation recipes to create uniform-density 1 μm surface layers of 15 N or vacancies (using 4 He).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AlGaN/GaN metal-insulator-semiconductor high electron mobility transistors with reduced leakage current and enhanced breakdown voltage using aluminum ion implantation

This letter has studied the performance of AlGaN/GaN metal-insulator-semiconductor high electron mobility transistors on silicon substrate with GaN buffer treated by aluminum ion implantation for insulating followed by a channel regrown by metal–organic chemical vapor deposition. For samples with Al ion implantation of multiple energies of 140 keV (dose: 1.4 × 10{sup 14} cm{sup −2}) and 90 keV (dose: 1 × 10{sup 14} cm{sup −2}), the OFF-state leakage current is decreased by more than 3 orders and the breakdown voltage is enhanced by nearly 6 times compared to the samples without Al ion implantation. Besides, little degradation of electrical properties of the 2D electron gas channel is observed where the maximum drain current I{sub DSmax} at a gate voltage of 3 V was 701 mA/mm and the maximum transconductance g{sub mmax} was 83 mS/mm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗