A method for indexing field ion micrographs.
Field-ion micrograph indexing noting equivalence of pseudostereographic projection to Brandon proposals for pole identification
Impacts on the Hubble Space Telescope Wide Field and Planetary Camera 2: Microanalysis and Recognition of Micrometeoroid Compositions
Postflight surveys of the Wide Field and Planetary Camera 2 (WFPC2) on the Hubble Space Telescope have located hundreds of features on the 2.2 by 0.8 m curved plate, evidence of hypervelocity impact by small particles during 16 years of exposure to space in low Earth orbit (LEO). The radiator has a 100 - 200 micron surface layer of white paint, overlying 4 mm thick Al alloy, which was not fully penetrated by any impact. Over 460 WFPC2 samples were extracted by coring at JSC. About half were sent to NHM in a collaborative program with NASA, ESA and IBC. The structural and compositional heterogeneity at micrometer scale required microanalysis by electron and ion beam microscopes to determine the nature of the impactors (artificial orbital debris, or natural micrometeoroids, MM). Examples of MM impacts are described elsewhere. Here we describe the development of novel electron beam analysis protocols, required to recognize the subtle traces of MM residues.
Discovery of hydrated Clasts with Very High Abundance of Ferromagnesian 160-Rich Olivine: Inner or Outer Solar System origin?
Olivine is one of the major minerals in chondritic meteorites and occurs in all chondritic components, including amoeboid olivine aggregates (AOAs), forsterite-bearing Type B (FoB) Ca, Al-rich inclusions (CAIs), chondrules, and matrices. As a result, olivines could preserve chemical and isotopic characteristics of their formation environments. There are significant variations in oxygen isotopic compositions of chondritic olivine. Forsteritic olivine in AOAs and FoB-CAIs has solar-like 16O-rich compositions (D17O ~ -23±2‰); the former condensed from an 16O-rich gas of ~solar composition, whereas the latter crystallized from remelted condensates in an isotopic similar gaseous reservoir. Olivine phenocrysts in chondrules are significantly 16O-depleted compared to CAIs and AOAs: D17O ranges from ~ -7 to +3‰. Only rare relict olivines in chondrules have CAI/AOA-like 16O-rich compositions; these grains most likely represent fragments of CAIs and AOAs incompletely melted during chondrule formation. Olivine in matrices of weakly metamorphosed meteorites is extremely fine-grained (<100 nm) and has predominantly forsteritic composition. In metamorphosed chondrites, matrix olivines are coarse-grained (up to 10 μm) and enriched in FeO. Due to small grain sizes, oxygen isotopic compositions of matrix olivines are poorly known. Mapping of matrices of Vigarano and Kakangari using isotope microscopes (secondary ion mass-spectrometer (SIMS) plus SCAPS detector) revealed the presence of 16O-rich olivine grains. While most matrix olivines in Vigarano have 16O-poor compositions, nearly half of olivines measured in Kakangari matrix are16O-rich.Here, we present for the first time new lithologies largely composed of 16O-and Fe-rich olivine. We attempt to address the question of whether these 16O-richolivine grains were formed by condensation in the solar nebula or by a secondary process during the evolution of the parent body. Mineralogical characteristics of these unusual olivines, as well as in-situ measured oxygen-isotope compositions of different phases are reported in detail.
Miniature recoil ion mass spectrometer enables correlative elemental isotopic and backscatter analysis from solid nanovolumes
Explore the source record for details and available documents.
Development of an In-Situ Ion Irradiation Dynamic Transmission Electron Microscope.
Abstract not provided.
Multimodal Stigmatic Imaging Mass Spectrometry with Flat-Top Laser Probe: SBIR Phase I Final Technical Report
Explore the source record for details and available documents.
Growth of microscopic cones on titanium cathodes of sputter-ion pumps driven by sorption of large argon quantities
Microscopic cones have been observed on titanium cathodes of sputter-ion pumps (SIPs) after pump operation. The cones were studied by means of scanning electron microscopy and energy dispersive x-ray analysis. Size and morphology of these cones are clearly correlated with the nature and the relative amount of each gas species pumped by each SIP during its working life. In particular, their growth was found to be fed by sputtering mechanisms, mostly during Ar pumping, and to be driven by the electromagnetic field applied to the Penning cells of each SIP. Experimental findings suggest that the formation and extent of such conic structures on cathode surfaces might play a leading role in the onset of phenomena typically related to the functioning of SIPs, e.g., the so-called argon instability.
Ion and laser microprobes applied to the measurement of corrosion produced hydrogen on a microscopic scale.
Use of an ion microprobe and a laser microprobe to measure concentrations of corrosion-produced hydrogen on a microscopic scale. Hydrogen concentrations of several thousand ppm were measured by both analytical techniques below corroded and fracture surfaces of hot salt stress corroded titanium alloy specimens. This extremely high concentration compares with only about 100 ppm hydrogen determined by standard vacuum fusion chemical analyses of bulk samples. Both the ion and laser microprobes were used to measure hydrogen concentration profiles in stepped intervals to substantial depths below the original corroded and fracture surfaces. For the ion microprobe, the area of local analysis was 22 microns in diameter and for the laser microprobe, the area of local analysis was about 300 microns in diameter. The segregation of hydrogen below fracture surfaces supports a previously proposed theory that corrosion-produced hydrogen is responsible for hot salt stress corrosion embrittlement and cracking of titanium alloys. These advanced analytical techniques suggest great potential for many areas of stress corrosion and hydrogen embrittlement research, quality control, and field inspection of corrosion problems. For example, it appears possible that a contour map of hydrogen distribution at notch roots and crack tips could be quantitatively determined. Such information would be useful in substantiating current theories of stress corrosion and hydrogen embrittlement.
A high resolution scanning electron microscope for in situ investigation of swift heavy ion induced modification of solid surfaces
A new in situ high resolution electron microscope (HRSEM) setup has been designed and integrated into the materials science beamline (M-branch) of the universal linear accelerator at Gesellschaft fuer Schwerionenforschung, Darmstadt for in situ investigations of swift heavy ion induced surface modifications. Special ports for in situ experiments are installed at the HRSEM chamber to connect it to the high vacuum beamline, which is equipped with suitable beam control and shaping devices. In order to demonstrate the feasibility and power of this new instrument, first experiments were performed on a 50-nm-thick Fe{sub 2}O{sub 3} film on Si substrate, which exhibited submicrometer size holes due to irradiation induced dewetting in a previous experiment. We have demonstrated that with our new instrument, the development of individual dewetting holes as a function of the ion fluence can be investigated and even the interaction between them can be studied. To illustrate pattern formation during grazing incidence, 3.6 MeV/u {sup 131}Xe ion irradiation was carried out on a 25-nm-thick NiO film on SiO{sub 2}/Si at a tilt angle of 75 deg. The SEM image sequence recorded during the experiment reveals the development of a lamellaelike structure also seen before in ex situ experiments. With our new in situ setup, however, we are able to not only investigate the overall average pattern formation, but also to track the formation and decay of individual linking structures, which would be hardly possible in a standard ex situ experiment.
Basics of the scanning electrochemical microscope and its application in the characterization of lithium-ion batteries: a brief review
A scanning electrochemical microscope (SECM) can directly monitor electrochemical processes at interfaces of electrodes and electrolytes and has been used as an analytical tool for lithium-ion battery (LIB) studies. Through SECM, we can visualize the electrochemical reactivities of active species in LIBs in-situ during cycling. This review begins with introducing SECM-based LIB research and then summarizes the working mechanism and operating modes of the technique as well as combinations of SECM with other techniques for LIB studies. We review the results with a focus on the interfacial properties, surface reactions and electrochemical activity of different electrode materials for LIBs. The investigations of battery degradation, kinetic parameters and electrolyte swelling by SECM are also discussed. Finally, the current limitations and perspectives are also described regarding future developments.
Biomedical applications of ion-beam technology
Microscopically-rough surface texture of various biocompatible alloys and polymers produced by ion-beam sputtering may result in improvements in response of hard or soft tissue to various surgical implants.
Microscopic diamond solid-immersion-lenses fabricated around single defect centers by focused ion beam milling
Recent efforts to define microscopic solid-immersion-lenses (SIL) by focused ion beam milling into diamond substrates that are registered to a preselected single photon emitter are summarized. We show how we determine the position of a single emitter with at least 100 nm lateral and 500 nm axial accuracy, and how the milling procedure is optimized. The characteristics of a single emitter, a Nitrogen Vacancy (NV) center in diamond, are measured before and after producing the SIL and compared with each other. A count rate of 1.0 × 10{sup 6} counts/s is achieved with a [111] oriented NV center.
Integrated Molecular and Microscopic Scale Insight into Morphology and Ion Dynamics in Ca2+-Mediated Natural Organic Matter Floccs
Combined X-ray diffraction (XRD), helium ion microscopy (HeIM), and Ca-43 nuclear magnetic resonance (NMR) results provide novel insight into the nano- and microstructure of flocculated NOM; the molecular-scale interaction among natural organic matter (NOM), dissolved Ca2+ ions, and water in NOM floccs; and the effects of pH and ionic strength on these characteristics. Suwannee River humic acid (HA), fulvic acid (FA), and NOM flocculated from Ca2+ bearing solutions share similar morphological characteristics on the 100 nm to micron scales, including micron-sized equant fragments and rounded, rough areas with features on the 100 nm scale. HeIM suggests that the NOM floccs are built from a fundamental spheroidal structure that is similar to 10 nm in diameter, in agreement with published AFM and small-angle X-ray scattering results. Calcium is incorporated into these floccs at 100% relative humidity in a wide range of disordered structural environments, with basic pH leading to shorter mean Ca-O distances and lower mean coordination numbers with respect to floccs formed under acidic conditions. The NMR results show that dynamical processes involving water and Ca2+ occurring at frequencies >10(4) Hz are important for hydrated OM floccs, in agreement with published molecular dynamics simulations of OM in solution. From the NMR results, we find evidence for two Ca2+ dynamic averaging mechanisms: one related to rapid exchange (>100 kHz) between surface proximity-restricted (those within 5 angstrom of a surface) and bulk solution environments when excess Ca2+ is present in the pore solution when pore water is unfrozen and a second consisting of intermediate scale (tens of kHz) site exchange among strongly sorbed inner-sphere sites when excess Ca2+ is absent and the carboxylic and phenolic functional groups of the NOM are deprotonated.
Microscopic Mechanisms of Superionic Na-ion Conductivity in Crystalline and Amorphous NaMOCl 4 (M = Nb, Ta) Solid Electrolytes
Sodium-ion solid electrolytes offer a sustainable route toward next-generation batteries, but few match the performance of their lithium counterparts. Halide-based NaMOCl 4 (M = Nb, Ta) has recently emerged as a promising analogue to LiMOCl 4 , yet its structure–transport relationships remain unclear due to poor crystallinity in experiments. Here, we combine density functional theory and machine-learned molecular dynamics to reveal that crystalline NaMOCl 4 exhibits negligible room-temperature conductivity with high activation barriers arising from vacancy-mediated diffusion below an order–disorder transition. Above this transition, rotational and translational motion of the [MO 2/2 Cl 4 – ] ∞ chains create new Na sites and enhances transport. In contrast, the amorphous phase inherently supports facile, three-dimensional Na diffusion through dynamic framework flexibility. These results show that ordered crystalline phases hinder ionic transport, while disorder – either thermally induced or structural – facilitates it, revising prior assumptions from the Li system and providing design principles for high-conductivity Na halide electrolytes.
Coupling a 6 MV Tandem and an Ion Gun to a Scanning Electron Microscope.
Abstract not provided.
A charge-transfer resistance model and Arrhenius activation analysis for hydrogen ion transmission across single-layer graphene
Transmission rates for protons and deuterons across single-layer graphene embedded in Nafion | graphene | Nafion sandwich structures are measured as a function of temperature in electrochemical hydrogen pump cells. Rates of ion transmission through graphene are obtained in the form of area-normalized ion-transfer resistances, and are interpreted in terms of ion-exchange current densities and standard heterogeneous ion-transfer rate constants. An encounter pre-equilibrium model for the ion-transfer step is then used to provide rate constants for the fundamental microscopic step of ion (proton or deuteron) transmission across graphene. Application of this rate model to interpret variable-temperature data on proton and deuteron transmission rates provides values for the activation energy and pre-exponential factor for the fundamental ion transmission step across graphene. Activation energies obtained from the Arrhenius plots for proton and deuteron transmission are as follows; for proton, E act = 48 ± 2 kJ/mole (0.50 ± 0.02 eV) and for deuteron, E act = 53 ± 5 kJ/mole (0.55 ± 0.05 eV). The difference between these two values of approximately 5 kJ/mole is in good agreement with the expected difference in vibrational zero-point energies for O—H and O-D bonds, albeit with some uncertainty given the uncertainties in the activation energy values. Pre-exponential frequency factor values of 8.3 ± 0.4 × 10 13 s -1 and is 4.7 ± 0.5 × 10 13 s -1 were obtained for proton and deuteron transmission respectively across graphene. These pre-factor values are both quite large, on the order of the values predicted from the Eyring – Polanyi equation with a transmission coefficient near one. The ratio of 1.8 for the rate pre-factors (H/D) is in reasonable agreement with the value of 1.3 for the ratio of bond vibrational frequencies for O—H and O-D stretching, respectively. Taken together, these data support a model in which proton and deuteron transmission across graphene are largely adiabatic processes for which the differences in transmission rate at room temperature are due largely to differences in activation energies.
Microstructure of RERTR Du-Alloys Irradiated with Krypton Ions up to 100 dpa
The radiation stability of the interaction product formed at the fuel–matrix interface of research reactor dispersion fuels, under fission-product bombardment, has a strong impact on fuel performance. Three depleted uranium alloys were cast that consisted of the following five phases to be investigated: U(Si, Al)3, (U, Mo)(Si, Al)3, UMo2Al20, U6Mo4Al43, and UAl4. Irradiation of transmission electron microscopy (TEM) disc samples with 500-keV Kr ions at 200 °C to doses up to 100 displacements per atom (dpa) were conducted using a 300-keV electron microscope equipped with an ion accelerator. TEM results show that the U(Si, Al)3 and UAl4 phases remain crystalline at 100 dpa without forming voids. The (U, Mo)(Si, Al)3 and UMo2Al20 phases become amorphous at 1 and 2 dpa, respectively, and show no evidence of voids at 100 dpa. The U6Mo4Al43 phase goes to amorphous at less than 1 dpa and reveals high density voids at 100 dpa.