Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

114 records · Page 7

Squeezing Every Last 'Bit' of Information from Enceladus Mass Spectrometry

Potential opportunities to return to Enceladus in Discovery and Flagship class missions inspire development of next-generation instruments and creative approaches to sample collection, sample analysis, and data analysis and transmission strategies. Mass spectrometers (MS) are ideally suited to future Enceladus missions due to their analytical power in identifying a range of molecular and ionic compositions – including complex organics – and potentially astrobiologically-important features such as isotope ratios, chirality, and enantiomeric excess. However, long communication delays from Enceladus and limited bandwidth limits the data transmission from these higher-data-volume instruments, likely delaying mission-related response to new data. We explore the utility of data science and machine learning (ML) on isotope ratio (IR)MS data collected from laboratory analogs of Enceladus to: 1) process data quickly for rapid ground-based analyses, 2) understand if compositional and biosignature information could be extracted from IRMS data, and 3) evaluate whether onboard ML techniques could improve sample analysis, cadence, and transmission prioritization. Laboratory analogs analyzed isotopes of volatile CO2 that interacted with seawaters of varying composition, and include both abiotic and biotic (microbially-influenced) experiments. Enceladus’s alkaline oceans promote speciation of carbon into multiple forms (e.g., H2CO3 / CO2, HCO3-, and CO32-), each of which could be isotopically fractionated by abiotic or biotic reactions. Large (>2‰) changes in carbon isotopes (δ13C) are observed from some biotic experiments inoculated with complex microbial ecosystems relative to the abiotic seawaters. ML training and classification suggests that microbial samples can be distinguished from abiotic samples, yet that a broad range of microbial experiments are necessary to train ML models to cover a range of complexities including disequilibria, and isotopic and compositional fractionation.

geochemistry↗

Autonomous Science: Simulated Solar System Mission to Enceladus, Icy Ocean Moon of Saturn

Future NASA missions to icy ocean worlds such as Europa, Titan, or Enceladus will collect mass spectrometry (MS) data from exospheres, atmospheres, and plume volatiles to assess their geochemistry and potential for microbial life1. These remote missions face challenges related to limited bandwidth, communication, and power, highlighting the need for science autonomy2 to prioritize data for timely downlink. We extend our previous work on machine learning (ML) biosignature detection from isotope ratio mass spectrometry (IRMS) data to distributed systems missions (DSM) by incorporating the ML and autonomous data quality control and prioritization code into an onboard decision-making platform. We use simulated orbital telemetry for eight orbiters around Enceladus with a mothership to illustrate an automated biosignature and novel seawater chemistry detection with data prioritization from MS analyses of volatile CO2.

Conor Williams↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

Large-Volume Injection and Assessment of Reference Standards for n -Alkane δD and δ 13 C Analysis via Gas Chromatography Isotope Ratio Mass Spectrometry

Compound-specific stable isotope analysis of hydrogen (δD) and carbon (δ 13 C) in organic compounds is a valuable tool in biogeochemical research. A key limitation of this method is the relatively large amount of sample required to achieve desirable precision. We developed a large-volume (20 μL) injection method that allows for high throughput analysis of less concentrated samples and tested it for δ 13 C and δD measurements of n-alkanes. We also conducted a comparison of reference standards and assessed several methods to normalize and correct n-alkane δD and δ13C measurements. The mean precision of the δD method based on 233 environmental n-alkane samples (two to three replications per sample) is 4.0‰ (1σ, estimated from the weighted mean of the pooled unbiased standard deviations) and 0.46‰ (1σ) for δ 13 C from 37 environmental samples (two to three replications per sample). The evaluation of reference standards shows that the use of n-alkane standards with large offsets in δD values in adjacent n-alkane chains can lead to biases in measurement correction. The large-volume injection method shows good reproducibility of δ 13 C and δD measurements of n-alkanes and reduces the required sample concentration by about 80%. We propose that for δD measurements, a reference standard set should be used in which each reference standard has a limited range of δD values and no adjacent n-alkane chains, to minimize memory effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An approach for spent nuclear fuel containment integrity verification using gas tagging

Verification of containment integrity is required for spent nuclear fuel (SNF) managed by the commercial nuclear industry and U.S. Department of Energy (DOE), especially after extended storage. Certain SNF storage systems, such as the DOE road-ready dry storage system, hold several packaged containments within a welded over-canister. These packaged containments are called Department of Energy Standard Canisters (DOESCs). DOESC leakage identification is challenging because their containment boundary cannot be accessed for testing and their contents (i.e., SNF and fill gas) are often similar. There are concerns that this could result in costly characterization and repackaging operations of DOE road-ready dry storage systems if compromised DOESCs are suspected. Here, to address these concerns, this paper presents an approach for applying a gas tagging process using xenon to uniquely identify compromised inaccessible containments following extended storage. The containments considered for this application are seven DOESCs, each packaged within a single over-canister. Two different SNF loading configurations from the Advanced Test Reactor and Fort Saint Vrain nuclear power plant are considered. These configurations are used to represent research reactor aluminum-clad spent nuclear fuel (ASNF) and TRi-structural ISOtropic (TRISO) SNF types. Results for this application show that for ASNF and TRISO type fuels for which the selected fuels are representative, the volume of taggant required at loading is determined primarily by the lower detection limit and leak rate of taggant from a compromised DOESC, rather than the amount of fission-generated xenon in the loaded fuel. While the application presented is suited for larger leaks, smaller leaks could be detected by modifying certain design parameters. This gas tagging approach can also be applied to other DOE containments and advanced reactor SNF storage systems.

07 - ISOTOPES AND RADIATION SOURCES↗

Miniature Tunable Laser Spectrometers for Quantifying Atmospheric Trace Gases, Water Resources, Earth Back-Contamination, and In Situ Resource Utilization

The Tunable Laser Spectrometers (TLS) technique has seen wide applicability in gas measurement and analysis for atmospheric analysis, industrial, commercial and health monitoring and space applications. In Earth science using balloons and aircraft over 2 decades, several groups (JPL, NASA Langley & Ames, NOAA, Harvard U., etc) have demonstrated the technique for ozone hole studies, lab kinetics measurements, cloud physics and transport, climate change in the ice record. The recent availability of high-power (mW) room temperature lasers (TDL, IC, QC) has enabled miniaturized, high-sensitivity spectrometers for industry and space (1) Mars, Titan, Venus, Saturn, Moon (2) Commercial isotope ratio spectrometers are replacing bulkier, complex isotope ratio mass spectrometers.

Tunable laser spectrometers (TLS)↗