Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image Transmission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Development of Leaky Wave Antennas for Layered Ridge Dielectric Waveguide

The millimeter wave, especially above 100 GHz, and the submillimeter wave frequency spectrum offers the possibility for narrow-beam, high-resolution antennas which are critical for high definition radars required for space debris tracking, airport ground avoidance radars, and missile tracking. In addition, the frequency which most atmospheric constituents may be detected lie in this part of the frequency spectrum. Therefore, the development of electronic components for millimeter/submillimeter wave passive sensors is required for environmental monitoring of the Earth's atmosphere. Typical microwave transmission lines such as microstrip and coplanar waveguide rely on two or more electrical conductors to concentrate and guide the electromagnetic energy. Unfortunately, the surface resistance of the conductors increases as the square root of frequency. In addition, the circuit dimensions must be decreased with increasing frequency to maintain a single mode transmission line which further increases the conductor loss. An alternative family of transmission lines are formed from two or more insulating materials and rely on the differences in the permittivities between the two materials to guide the wave. No metal conductors are required although some dielectric waveguides do utilize a metallic ground plane to facilitate the interconnections of active electrical elements or to reduce the transmission line size. Examples of such transmission lines are image guides, insulated image guides, trapped image guides, ridge guide, and layered ridge dielectric waveguide (LRDW). Although most dielectric waveguides have dimensions on the order of lambda to provide sufficient field confinement, the LRDW has been shown to provide good field confinement for electrically small lines. This offers an advantage in circuit integration. It has been shown that a periodic array of metallic strips placed either along or on top of a dielectric waveguide forms an effective radiator. This antenna is easy to fabricate and there is good background of microstrip type antenna design information in the literature. This paper reports the development of the first frequency scanning antenna fed by a LRDW.

Ponchak, George E.↗

Optical and Probe Diagnostics Applied to Reacting Flows

The general theme of the research my NASA colleague and I have planned is "Optical and probe diagnostics applied to reacting flows". We plan to explore three major threads during the fellowship period. The first interrogates the flame synthesis of carbon nanotubes using aerosol catalysts. Having demonstrated the viability of the technique for nanotube synthesis, we seek to understand the details of this reacting system which are important to its practical application. Laser light scattering will reveal changes in particle size at various heights above the burner. Analysis of the flame gas by mass spectroscopy will reveal the chemical composition of the mixture. Finally, absorption measurements will map the nanotube concentration within the flow. The second thread explores soot oxidation kinetics. Despite the impact of soot on engine performance, fire safety and pollution, models for its oxidation are inhibited by uncertainty in the values of the oxidation rate. We plan to employ both optical and microscopic measurements to refine this rate. Cavity ring-down absorption measurements of the carbonaceous aerosol can provide a measure of the mass concentration with time and, hence, an oxidation rate. Spectroscopic and direct probe measurements will provide the temperature of the system needed for subsequent modeling. These data will be benchmarked against changes in soot nanostructures as revealed by transmission electron microscopic images from directly sampled material.

Ticich, Thomas M.↗

Wide-Field-of-View, High-Resolution, Stereoscopic Imager

A device combines video feeds from multiple cameras to provide wide-field-of-view, high-resolution, stereoscopic video to the user. The prototype under development consists of two camera assemblies, one for each eye. One of these assemblies incorporates a mounting structure with multiple cameras attached at offset angles. The video signals from the cameras are fed to a central processing platform where each frame is color processed and mapped into a single contiguous wide-field-of-view image. Because the resolution of most display devices is typically smaller than the processed map, a cropped portion of the video feed is output to the display device. The positioning of the cropped window will likely be controlled through the use of a head tracking device, allowing the user to turn his or her head side-to-side or up and down to view different portions of the captured image. There are multiple options for the display of the stereoscopic image. The use of head mounted displays is one likely implementation. However, the use of 3D projection technologies is another potential technology under consideration, The technology can be adapted in a multitude of ways. The computing platform is scalable, such that the number, resolution, and sensitivity of the cameras can be leveraged to improve image resolution and field of view. Miniaturization efforts can be pursued to shrink the package down for better mobility. Power savings studies can be performed to enable unattended, remote sensing packages. Image compression and transmission technologies can be incorporated to enable an improved telepresence experience.

Prechtl, Eric F.↗

Organic Nano-Grains in Comet 103P/Hartley 2: The Organic Glue of Porous Aggregate Grains?

The GNIRS instrument on the Gemini 8-­‐m telescope observed comet 103P/Hartley on 2010-­‐ Dec-­‐04UT, a month after the EPOXI Mission encounter, and detected the 3.3 and 3.4 um bands in emission. The 3.3/3.4 ratio and the broad band widths are consistent with experiments of heated (approximately 600 K) aliphatic carbon (-CH3, -CH2) thin films. For the 3.4 micron band to be in emission, the aliphatic bonds must be attached to a carrier possessing the strongly UV-­‐absorbing C=C aromatic rings, and these rings have to be less than 50-­‐100 carbon atoms (4-6 Angstrom) for attached -CH bonds to also generate a 3.3 micron-band in emission. Slightly larger (≥10Å) Very Small Grains (VSGs) can absorb single UV photons comparable to or exceeding their heat capacity, thermally fluctuate and release IR photon(s). The 3.3 micron and 3.4 micron bands observed by GNIRS suggest that organic macromolecules/ nano-­‐grains with both aliphatic and aromatic bonds are fluorescing/thermally fluctuating in the coma. Aliphatic and aromatic materials have been seen in Stardust samples and the primitive carbonaceous chondrite 'Tagish Lake'. The larger the ratio of the -CH2/-CH3 components of the aliphatic 3.4 micron band, the more 'primitive' the organic material. In a Stardust organic globule, some aliphatic bonds were transformed into aromatic bonds during the low dosage of Transmission Electron Microscope imaging. Conversely, lab experiments show irradiation of ices containing small PAHs generates aliphatic organics. Photo-­‐processing of ices also likely forms the ubiquitous aliphatic coatings that appear on the surfaces of all silicate subgrains constituting nine cometary interplanetary dust particles. The aliphatic coatings, dominated by -CH2, likely were important in sticking the aggregates together, and existed prior to incorporation of dust aggregates into comet nuclei. These comet aliphatics may be some of the sought-­‐after precursors to the more robust and complex organics studied as Insoluble Organic Matter in carbonaceous chondrites. Aliphatic coatings on submicron grains, however, will not be observable in absorption because they are fairly transparent, nor do the aliphatic carbonaceous coatings produce the 3.4 micron emission band because the particles they are attached to are too large (too many vibration modes). We must probe the nano-­‐sized organic carriers that undergo substantive thermal fluctuations in cometary comae and emit at 3.3 3.4 micron. Observations of the 3.3 and 3.4 micron emission features contribute to characterizing the evolution of organics prior to their incorporation into cometary nuclei as well as their rapid evolution in cometary comae, which in turn contributes to deepening our understanding of the evolution of organics on the surfaces of asteroids and outer icy bodies in our solar system. Studying organics in comets contributes to understanding the formation and evolution pathways of ISM organics through to the formation of the robust insoluble organic matter in meteorites. A'Hearn, M.F., et al. 2011, Science, 332, 1396; Bockelee-­‐Morvan, D. et al. 1995, Icarus, 116, 18; De Gregorio, B.T., et al. 2010, GCA, 74, 4454; Dello Russo, N., et al. 2011, ApJ, 734, L8; Dischler et al. 1983, Solid State Communications, 48, 105; Flynn, G., et al. 2010a, LPSC, 41, #1079; Flynn, G., et al. 2010b, COSPAR, 38, F31-­‐0012-­‐10; Flynn, G., Wirick, S. 2011, LPSC, 42, #1856; Fomenkova, et al. 1994, GCA 58, 4503; Matrajt, G., et al. 2013, ApJ, 765, 145; Schutte, et al. 1993, ApJ, 415, 397; Wooden, D.H. et al. 2011, EPSC-­‐DPS, 1557; Wooden, D.H. et al. 2013, submitted.

Stardust samples↗

Complex Intergrowths of Non-Stoichiometric Defect-Structured Hibonite and Al-Rich Spinel in an Allende Ca-Al-Rich Inclusion

Hibonite is a primary ultra-refractory mineral occurring in many Ca-Al-rich inclusions (CAIs) and is predicted to condense as the second major phase from a cooling gas of solar composition. Our previous microstructural studies of hibonite in carbonaceous chondrites revealed its unique microstructures consisting of numerous defects that contain Mg-enriched, wider spinel blocks in stoichiometric hibonite. Han, J. et al. [2 items] demonstrated experimentally that defect-structured hibonites can grow easily in the presence of minor Mg and are kinetically more stable than equilibrium assemblages predicted by thermodynamic calculations. However, a thermo-dynamic vs. structural stability of defect-structured hibonite relative to other early-condensed Al-rich phases such as corundum, grossite, and spinel remains poorly constrained. Here, we present the results of atomic resolution TEM (Transmission Electron Microscopy) imaging of hibonite in a compact Type A CAI in the Allende CV3 chondrite in order to better understand the crystal structure and chemistry of defect-structured hibonite and its associated Al-rich phases, especially non-stoichiometric, Al-rich spinel, in the context of the formation of first refractory solids in the early solar nebula.

Han, J.↗

Compression through decomposition into browse and residual images

Economical archival and retrieval of image data is becoming increasingly important considering the unprecedented data volumes expected from the Earth Observing System (EOS) instruments. For cost effective browsing the image data (possibly from remote site), and retrieving the original image data from the data archive, we suggest an integrated image browse and data archive system employing incremental transmission. We produce our browse image data with the JPEG/DCT lossy compression approach. Image residual data is then obtained by taking the pixel by pixel differences between the original data and the browse image data. We then code the residual data with a form of variable length coding called diagonal coding. In our experiments, the JPEG/DCT is used at different quality factors (Q) to generate the browse and residual data. The algorithm has been tested on band 4 of two Thematic mapper (TM) data sets. The best overall compression ratios (of about 1.7) were obtained when a quality factor of Q=50 was used to produce browse data at a compression ratio of 10 to 11. At this quality factor the browse image data has virtually no visible distortions for the images tested.

Novik, Dmitry A.↗

Adaptive Bandwidth Compression For Moving Images

Data compressed in images with fast motion and expanded when motion slows. Proposed data-compression scheme adapts transmission rate for moving image to speed of motion of image. Laser rangefinder measures speed of target. Adaptive sampler determines required resolution of target image on basis of measured speed and provides decommutator at control station with more or fewer partial image fields per unit time. When monitor displays maximum number of fields simultaneously, resolution is highest.

Graham, Olin L.↗

Improved reduced-resolution satellite imagery

The resolution of satellite imagery is often traded-off to satisfy transmission time and bandwidth, memory, and display limitations. Although there are many ways to achieve the same reduction in resolution, algorithms vary in their ability to preserve the visual quality of the original imagery. These issues are investigated in the context of the Landsat browse system, which permits the user to preview a reduced resolution version of a Landsat image. Wavelets-based techniques for resolution reduction are proposed as alternatives to subsampling used in the current system. Experts judged imagery generated by the wavelets-based methods visually superior, confirming initial quantitative results. In particular, compared to subsampling, the wavelets-based techniques were much less likely to obscure roads, transmission lines, and other linear features present in the original image, introduce artifacts and noise, and otherwise reduce the usefulness of the image. The wavelets-based techniques afford multiple levels of resolution reduction and computational speed. This study is applicable to a wide range of reduced resolution applications in satellite imaging systems, including low resolution display, spaceborne browse, emergency image transmission, and real-time video downlinking.

Ellison, James↗

Stereo Imaging Miniature Endoscope with Single Imaging Chip and Conjugated Multi-Bandpass Filters

A dual objective endoscope for insertion into a cavity of a body for providing a stereoscopic image of a region of interest inside of the body including an imaging device at the distal end for obtaining optical images of the region of interest (ROI), and processing the optical images for forming video signals for wired and/or wireless transmission and display of 3D images on a rendering device. The imaging device includes a focal plane detector array (FPA) for obtaining the optical images of the ROI, and processing circuits behind the FPA. The processing circuits convert the optical images into the video signals. The imaging device includes right and left pupil for receiving a right and left images through a right and left conjugated multi-band pass filters. Illuminators illuminate the ROI through a multi-band pass filter having three right and three left pass bands that are matched to the right and left conjugated multi-band pass filters. A full color image is collected after three or six sequential illuminations with the red, green and blue lights.

Shahinian, Hrayr Karnig↗

A preliminary investigation of communication techniques for local and remote access to image databases

A software technique which allows users to examine images remotely while minimizing transmission time, is discussed. The technique provides a browsing capability, making it possible to roam over larger images, to zoom to various resolution levels, and to specify subregions of interest in the image to display at full resolution. The software permits analysts to remotely submit images for processing and to review the processing result. The capabilities of the technique under varying conditions and the speed at which imagery can be displayed over direct connect serial lines are discussed and examples of the imagery at various levels of resolution are presented.

Ma, Mathias↗

The Effects of Radiation on Imagery Sensors in Space

Recent experience using high definition video on the International Space Station reveals camera pixel degradation due to particle radiation to be a much more significant problem with high definition cameras than with standard definition video. Although it may at first appear that increased pixel density on the imager is the logical explanation for this, the ISS implementations of high definition suggest a more complex causal and mediating factor mix. The degree of damage seems to vary from one type of camera to another, and this variation prompts a reconsideration of the possible factors in pixel loss, such as imager size, number of pixels, pixel aperture ratio, imager type (CCD or CMOS), method of error correction/concealment, and the method of compression used for recording or transmission. The problem of imager pixel loss due to particle radiation is not limited to out-of-atmosphere applications. Since particle radiation increases with altitude, it is not surprising to find anecdotal evidence that video cameras subject to many hours of airline travel show an increased incidence of pixel loss. This is even evident in some standard definition video applications, and pixel loss due to particle radiation only stands to become a more salient issue considering the continued diffusion of high definition video cameras in the marketplace.

Mathis, Dylan↗

X Ray, Far, and Extreme Ultraviolet Coatings for Space Applications

The idea of utilizing imaging mirrors as narrow band filters constitutes the basis of the design of extreme ultraviolet imagers operating at 58.4 nm and 83.4 nm. The net throughput of both imaging-filtering systems is better than 20 percent. The superiority of the EUV self-filtering camera/telescope becomes apparent when compared to previously theoretically designed 83.4-nm filtering-imaging systems, which yielded transmissions of less than a few percent and therefore less than 0.1 percent throughput when combined with at least two imaging mirrors. Utilizing the self-filtering approach, instruments with similar performances are possible for imaging at other EUV wavelengths, such as 30.4 nm. The self-filtering concept is extended to the X-ray region where its application can result in the new generation of X-ray telescopes, which could replace current designs based on large and heavy collimators.

Zukic, M.↗

A Compact 600 GHz Electronically Tunable Vector Measurement System for Submillimeter Wave Imaging

A compact submillimeter wave transmission / reflection measurement system has been demonstrated at 560-635 GHz, with electronic tuning over the entire band. Maximum dynamic range measured at a single frequency is 90 dB (60 dB typical), and phase noise is less than +/- 2(deg). By using a frequency steerable lens at the source output and mixer input, the frequency agility of the system can be used to scan the source and receive beams, resulting in near real-time imaging capability using only a single pixel.

submillimeter wave imaging↗

Multimode-Optical-Fiber Imaging Probe

Currently, endoscopic surgery uses single-mode fiber-bundles to obtain in vivo image information inside orifices of the body. This limits their use to the larger natural bodily orifices and to surgical procedures where there is plenty of room for manipulation. The knee joint, for example can be easily viewed with a fiber optic viewer, but joints in the finger cannot. However, there are a host of smaller orifices where fiber endoscopy would play an important role if a cost effective fiber probe were developed with small enough dimensions (< 250 microns). Examples of beneficiaries of micro-endoscopes are the treatment of the Eustatian tube of the middle ear, the breast ducts, tear ducts, coronary arteries, fallopian tubes, as well as the treatment of salivary duct parotid disease, and the neuro endoscopy of the ventricles and spinal canal. To solve this problem, this work describes an approach for recovering images from. tightly confined spaces using multimode fibers and analytically demonstrates that the concept is sound. The proof of concept draws upon earlier works that concentrated on image recovery after two-way transmission through a multimode fiber as well as work that demonstrated the recovery of images after one-way transmission through a multimode fiber. Both relied on generating a phase conjugated wavefront which was predistorted with the characteristics of the fiber. The described approach also relies on generating a phase conjugated wavefront, but utilizes two fibers to capture the image at some intermediate point (accessible by the fibers, but which is otherwise visually unaccessible).

Jackson, Deborah↗

Multimode-Optical-Fiber Imaging Probe

Currently, endoscopic surgery uses single-mode fiber-bundles to obtain in vivo image information inside the orifices of the body. This limits their use to the larger natural orifices and to surgical procedures where there is plenty of room for manipulation. The knee joint, for example, can be easily viewed with a fiber optic viewer, but joints in the finger cannot. However, there are a host of smaller orifices where fiber endoscopy would play an important role if a cost effective fiber probe were developed with small enough dimensions (less than or equal to 250 microns). Examples of beneficiaries of micro-endoscopes are the treatment of the Eustatian tube of the middle ear, the breast ducts, tear ducts, coronary arteries, fallopian tubes, as well as the treatment of salivary duct parotid disease, and the neuro endoscopy of the ventricles and spinal canal. This work describes an approach for recovering images from tightly confined spaces using multimode. The concept draws upon earlier works that concentrated on image recovery after two-way transmission through a multimode fiber as well as work that demonstrated the recovery of images after one-way transmission through a multimode fiber. Both relied on generating a phase conjugated wavefront, which was predistorted with the characteristics of the fiber. The approach described here also relies on generating a phase conjugated wavefront, but utilizes two fibers to capture the image at some intermediate point (accessible by the fibers, but which is otherwise visually inaccessible).

Jackson, Deborah↗

Low Resolution Picture Transmission (LRPT) Demonstration System

Low-Resolution Picture Transmission (LRPT) is a proposed standard for direct broadcast transmission of satellite weather images. This standard is a joint effort by the European Organization for the Exploitation of Meteorological Satellites (EUMETSAT) and NOAA. As a digital transmission scheme, its purpose is to replace the current analog Automatic Picture Transmission (APT) system for use in the Meteorological Operational (METOP) satellites. GSFC has been tasked to build an LRPT Demonstration System (LDS). Its main objective is to develop or demonstrate the feasibility of a low-cost receiver utilizing a PC as the primary processing component and determine the performance of the protocol in the simulated Radio Frequency (RF) environment. The approach would consist of two phases.

Fong, Wai↗

Low Resolution Picture Transmission (LRPT) Demonstration System

Low-Resolution Picture Transmission (LRPT) is a proposed standard for direct broadcast transmission of satellite weather images. This standard is a joint effort by the European Organization for the Exploitation of Meteorological Satellites (EUMETSAT) and the National Oceanic Atmospheric Administration (NOAA). As a digital transmission scheme, its purpose is to replace the current analog Automatic Picture Transmission (APT) system for use in the Meteorological Operational (METOP) satellites. Goddard Space Flight Center has been tasked to build an LRPT Demonstration System (LDS). It's main objective is to develop or demonstrate the feasibility of a low-cost receiver utilizing a Personal Computer (PC) as the primary processing component and determine the performance of the protocol in the simulated Radio Frequency (RF) environment. The approach would consist of two phases. In the phase 1, a Commercial-off-the-Shelf (COTS) Modulator-Demodulator (MODEM) board that would perform RF demodulation would be purchased allowing the Central Processing Unit (CPU) to perform the Consultative Committee for Space Data Systems (CCSDS) protocol processing. Also since the weather images are compressed the PC would perform the decompression. Phase 1 was successfully demonstrated on December 1997. Phase 2 consists of developing a high-fidelity receiver, transmitter and environment simulator. Its goal is to find out how the METOP Specification performs in a simulated noise environment in a cost-effective receiver. The approach would be to produce a receiver using as much software as possible to perform front-end processing to take advantage of the latest high-speed PCs. Thus the COTS MODEM used in Phase 1 is performing RF demodulation along with data acquisition providing data to the receiving software. Also, environment simulator is produced using the noise patterns generated by Institute for Telecommunications Sciences (ITS) from their noise environment study.

Fong, Wai↗

Data compression for National Oceanic and Atmospheric Administration /NOAA/ weather satellite systems

The National Oceanic and Atmospheric Administration (NOAA) receives high quality infrared weather images from each of its two geostationary weather satellites at an average data rate of 57 kilobits/second. These images are currently distributed to field stations over 3 kilohertz analog phone lines. The resulting loss in image quality renders the images unacceptable for proposed digital image processing. This paper documents the study leading to a current effort to implement a microprocessor-based universal noiseless coder/decoder to satisfy NOAA's requirements of high quality, good coverage and timely transmission of its infrared images.

Rice, R. F.↗