Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging & optical processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Image-plane processing of visual information

Shannon's theory of information is used to optimize the optical design of sensor-array imaging systems which use neighborhood image-plane signal processing for enhancing edges and compressing dynamic range during image formation. The resultant edge-enhancement, or band-pass-filter, response is found to be very similar to that of human vision. Comparisons of traits in human vision with results from information theory suggest that: (1) Image-plane processing, like preprocessing in human vision, can improve visual information acquisition for pattern recognition when resolving power, sensitivity, and dynamic range are constrained. Improvements include reduced sensitivity to changes in lighter levels, reduced signal dynamic range, reduced data transmission and processing, and reduced aliasing and photosensor noise degradation. (2) Information content can be an appropriate figure of merit for optimizing the optical design of imaging systems when visual information is acquired for pattern recognition. The design trade-offs involve spatial response, sensitivity, and sampling interval.

Huck, F. O.↗

Optical navigation for the Galileo Gaspra encounter

The optical navigation process as practiced during the Gaspra encounter is presented. The characteristics of image formation for a single-frame mosaic picture required the development of a new image processing algorithm to extract the optical measurements. A detailed formulation of this algorithm is presented along with the results of applying it to the pictures returned from the spacecraft.

Vaughan, R. M.↗

NASA spinoffs to bioengineering and medicine

Through the active transfer of technology, the National Aeronautics and Space Administration (NASA) Technology Utilization (TU) Program assists private companies, associations, and government agencies to make effective use of NASA's technological resources to improve U.S. economic competitiveness and to provide societal benefit. Aerospace technology from areas such as digital image processing, space medicine and biology, microelectronics, optics and electrooptics, and ultrasonic imaging have found many secondary applications in medicine. Examples of technology spinoffs are briefly discussed to illustrate the benefits realized through adaptation of aerospace technology to solve health care problems. Successful implementation of new technologies increasingly requires the collaboration of industry, universities, and government, and the TU Program serves as the liaison to establish such collaborations with NASA. NASA technology is an important resource to support the development of new medical products and techniques that will further advance the quality of health care available in the U.S. and worldwide.

Biomedical Engineering/instrumentation/trends↗

Proof of principle study: synchrotron X-ray fluorescence microscopy for identification of previously radioactive microparticles and elemental mapping of FFPE tissues

Biobanks containing formalin-fixed, paraffin-embedded (FFPE) tissues from animals and human atomic-bomb survivors exposed to radioactive particulates remain a vital resource for understanding the molecular effects of radiation exposure. These samples are often decades old and prepared using harsh fixation processes which limit sample imaging options. Optical imaging of hematoxylin and eosin (H&E) stained tissues may be the only feasible processing option, however, H&E images provide no information about radioactive microparticles or radioactive history. Synchrotron X-ray fluorescence microscopy (XFM) is a robust, non-destructive, semi-quantitative technique for elemental mapping and identifying candidate chemical element biomarkers in FFPE tissues. Still, XFM has never been used to uncover distribution of formerly radioactive micro-particulates in FFPE canine specimens collected more than 30 years ago. In this work, we demonstrate the first use of low-, medium-, and high-resolution XFM to generate 2D elemental maps of ~ 35-year-old, canine FFPE lung and lymph node specimens stored in the Northwestern University Radiobiology Archive documenting distribution of formerly radioactive micro-particulates. Additionally, we use XFM to identify individual microparticles and detect daughter products of radioactive decay. The results of this proof-of-principle study support the use of XFM to map chemical element composition in historic FFPE specimens and conduct radioactive micro-particulate forensics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiresponse Imaging For Improved Resolution

Images restored with resolution finer than sampling lattice. Multiresponse imaging overcomes sampling-passband constraint and critically constrained only by optical response and sensitivity of image-gathering device. Process consists of multiresponse image gathering and Wiener-matrix restoration. Image-gathering process acquires sequence of images, each with different optical response so within-pass-band and aliased signal components weighted differently. Wiener-matrix filter, in turn, unscrambles within-passband and aliased frequency components of undersampled signal and restores them up to cutoff frequency of optical response.

Fales, Carl L., Jr.↗

Two-dimensional optical processing using one-dimensional input devices

Two-dimensional optical processing architectures that are implemented with one-dimensional input spatial light modulators are reviewed. The advanced state of the art of available one-dimensional devices and the flexibility that exists in the design of two-dimensional architectures with one-dimensional transducers leads to the implementation of the most powerful and versatile optical processors. Signal and image processing architectures of this type are discussed.

Psaltis, D.↗

NASA spinoffs to bioengineering and medicine

The societal and economic benefits derived from the application of aerospace technology to improved health care are examined, and examples of the space-technology spinoffs are presented. Special attention is given to the applications of aerospace technology from digital image processing, space medicine and biology, microelectronics, optics and electrooptics, and ultrasonic imaging. The role of the NASA Technology Application Team in helping the potential technology users to identify and evaluate the technology transfer opportunities and to apply space technology in the field of medicine is discussed.

Rouse, Doris J.↗

Development of polarization-sensitive optical coherence tomography imaging platform and metrics to quantify electrostimulation-induced peripheral nerve injury in vivo in a small animal model

Neuromodulation devices are rapidly evolving for the treatment of neurological diseases and conditions. Injury from implantation or long-term use without obvious functional losses is often only detectable through terminal histology. New technologies are needed that assess the peripheral nervous system (PNS) under normal and diseased or injured conditions. We aim to demonstrate an imaging and stimulation platform that can elucidate the biological mechanisms and impacts of neurostimulation in the PNS and apply it to the sciatic nerve to extract imaging metrics indicating electrical overstimulation. A sciatic nerve injury model in a 15-rat cohort was observed using a newly developed imaging and stimulation platform that can detect electrical overstimulation effects with polarization-sensitive optical coherence tomography. The sciatic nerve was electrically stimulated using a custom-developed nerve holder with embedded electrodes for 1 h, followed by a 1-h recovery period, delivered at above-threshold Shannon model k-values in experimental groups: sham control (SC, n = 5, 0.0 mA / 0 Hz), stimulation level 1 (SL1, n = 5, 3.4 mA / 50 Hz, and k = 2.57), and stimulation level 2 (SL2, n = 5, 6.8 mA / 100 Hz, and k = 3.17). The stimulation and imaging system successfully captured study data across the cohort. When compared to a SC after a 1-week recovery, the fascicle closest to the stimulation lead showed an average change of +4 % / – 309 % (SL1/SL2) in phase retardation and –79 % / – 148 % in optical attenuation relative to SC. Analysis of immunohistochemistry (IHC) shows a +1 % / – 36 % difference in myelin pixel counts and –13 % / + 29 % difference in axon pixel counts, and an overall increase in cell nuclei pixel count of +20 % / + 35 % . These metrics were consistent with IHC and hematoxylin/eosin tissue section analysis. The poststimulation changes observed in our study are manifestations of nerve injury and repair, specifically degeneration and angiogenesis. Optical imaging metrics quantify these processes and may help evaluate the safety and efficacy of neuromodulation devices.

60 APPLIED LIFE SCIENCES↗

NAECON 87; Proceedings of the IEEE National Aerospace and Electronics Conference, Dayton, OH, May 18-22, 1987. Volumes 1, 2, 3, & 4

The present conference discusses topics in VLSI components and their packaging, signal processing, uses of cartographic data, data transmission, advanced avionics architectures, fiber-optics, information control and display, image processing, airborne radar and fire control, navigation, air data, Kalman filtering, power generation and control, spacecraft power structures, aircraft flying qualities, flight management, fault-tolerant computer architectures, actuation technologies, self-repairing flight control system technology, multivariable control, stability and control methods, and AFTI/F-16 flight test reports. Also discussed are the ADA/JOVIAL language and its applications, software acquisition and testing, advanced software concepts, software management, computer graphics and visual systems softwear, ADA in embedded avionics, 16- and 32-bit architectures, voice interaction applications, human/machine systems analysis, human factors and AI, mental workloads and displays, pilot acceleration protection research, communications system technology, space communications, reliability and maintainability, managerial techniques, engineering management, EM compatibility and nuclear hardening, expert systems, AI language/knowledge representation, expert system implementation, machine vision/optical processing, and advanced AI concepts and architectures.

Avionics↗

Science Application Teams

This paper discusses the science application team activities. Science Application team are: (1) Represent the diversity of NASA onboard computing of the future. (2) Drive architecture and system software requirements. (3) Demonstrate the benefit of highly capable computing onboard. (4) Study the birth of the first galaxies. (5) Study formation of stars. (6) Discusses the next generation space telescope hardware/software requirement: image processing and on-board optical calibration. Also discusses gamma ray large area space telescope; orbital thermal imaging spectrometer; solar terrestrial probe program; autonomous Mars rover;fault tolerance and errors.

Source record↗

Spatio-temporal ablation dynamics and plasma chemistry of aluminum induced by temporally modulated ytterbium fiber laser

Here, in this work, we studied single-pulse ablation dynamics of a temporally modulated continuous wave laser-material interaction with Al using in situ multimodal time-resolved diagnostics that describe in detail the associated physical and chemical processes. Time-resolved scattering, emission imaging, and optical emission spectroscopy unveiled a sequence of events spread out across three distinct phases: (i) early phase ablation process, associated with particle generation and liquid Al column formation (<20 μs), (ii) secondary detonation when sufficient ejected material is accumulated over the surface (20-50 μs), and (iii) molten liquid Al pool oscillation on the surface, followed by large droplet ejection from the liquid pool (100-500 μs). Atomic Al and AlO were observed with optical emission spectroscopy at different ratios during the entire lifetime of the event, verifying the formation of oxidized Al vapor upon its interaction with air. Morphological and compositional characterization confirmed surface oxidation and material re-solidification in the form of protrusions produced during the irradiation process. This work provides insights into the complex physical and chemical mechanisms of single-pulse ablation in the sub-millisecond laser pulse regime, which are critically important for parameter optimization in a variety of laser processing, microfabrication, and deposition applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Biomedical applications of NASA technology

Through the active transfer of technology, NASA Technology Utilization (TU) Program assists private companies, associations, and government agencies to make effective use of NASA's technological resources to improve U.S. economic competitiveness and to provide societal benefit. Aerospace technology from such areas as digital image processing, space medicine and biology, microelectronics, optics, and electro-optics, and ultrasonic imaging have found many secondary applications in medicine. Examples of technology spinoffs are briefly discussed to illustrate the benefits realized through adaptation of aerospace technology to solve health care problems. Successful implementation of new technologies increasingly requires the collaboration of industry, universities, and government and the TU Program serves as the liaison to establish such collaborations with NASA. NASA technology is an important resource to support the development of new medical products and techniques that will further advance the quality of health care available in the U.S. and worldwide.

Friedman, Donald S.↗

Experimentally-Derived Bidirectional Reflectance Distribution Function Data in Support of the Orbital Debris Program Office

The NASA Orbital Debris Program Office (ODPO) has used various optical assets to acquire photometric data of Earth-orbiting objects to define the orbital debris environment. To better characterize and model optical data acquired from ground-based telescopes, the Optical Measurements Center (OMC) at NASA Johnson Space Center emulates illumination conditions seen in space by using equipment and techniques that parallel telescopic observations and source-target-sensor orientations. One of the OMC goals is to improve the size calculation used for optical data by developing an optical-based Size Estimation Model. The current size estimation requires applying a Lambertian phase function, a set albedo value, and range to the observed magnitude. The first step to improving the sampled brightness of laboratory targets is to remove aspect-angle dependencies. Then, the volume of possible object viewing angles is sampled at 21 combinations of azimuth and zenith angles for each solar phase angle. Finally, the acquired images are input into an image processing program that generates approximations for the object’s Bidirectional Reflectance Distribution Function (BRDF) and phase function. The BRDF is a radiometric concept that identifies an object’s material composition by matching a BRDF approximated with photometric data collected by ground-based telescopes with a BRDF generated experimentally from a known object in the laboratory. This paper discusses the validation of experimental BRDF and phase function approximations produced in the OMC and how the findings will be incorporated into ODPO models. A Lambertian sphere is imaged and the subsequent experimental functions are scrutinized to confirm that they correspond to an object that has an isotropic luminance. With the image processing algorithm validated, test objects with varying optical properties are then imaged to confirm that the produced photometric functions are both unique and repeatable. Once the validation is complete, the OMC will be used to evaluate a subset of fragments from a hypervelocity impact test of a mock-up satellite and assess the appropriate phase function and size estimates using BRDF measurements for a large volume of targets composed of various shapes, sizes, and materials.

Orbital Debris Program Office (ODPO)↗

Pedestal fluctuation measurements with charge exchange imaging at the DIII-D tokamak

A new high radial resolution 2D multichannel Charge eXchange Imaging (CXI) diagnostic is under development for deployment at DIII-D. Here, the diagnostic system will measure low-to-intermediate radial wavenumber carbon density fluctuations by observing the n = 8 – 7 (λ = 529.06 nm) C-VI emission line, resulting from charge exchange collisions between heating neutral beam atoms and the intrinsic carbon ion density. The new CXI diagnostic will provide measurements with ΔR ~ 0.4 cm to access higher k r instabilities (k r < 8 cm –1 ) predicted to arise in the steep-gradient region of the H-mode pedestal. The CXI system will feature 60 fiber bundles in a 12 × 5 arrangement, with each bundle consisting of four 1 mm fibers. A custom optical system has been designed to filter and image incoming signals onto an 8 × 8 avalanche photodiode array. Additionally, a novel electronics suite has been designed and commissioned to amplify and digitize the relatively low-intensity carbon signal at a 2 MHz bandwidth. Forward modeling results of the active C-VI emission suggest sufficient signal to noise ratios to resolve turbulent fluctuations. Prototype measurements demonstrate the ability to perform high frequency pedestal measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coherent optical data processing and remotely sensed imagery

It is shown that an automatic imaging system consisting of a combination of optical and digital computer elements is feasible and has considerable advantages over direct image scanning systems. With such a system, it is possible to process very large quantities of remotely sensed image spectra.

Macdougall, E. B.↗

Advances in the photon avalanche luminescence of inorganic lanthanide-doped nanomaterials

Photon avalanche (PA)—where the absorption of a single photon initiates a ‘chain reaction’ of additional absorption and energy transfer events within a material—is a highly nonlinear optical process that results in upconverted light emission with an exceptionally steep dependence on the illumination intensity. Over 40 years following the first demonstration of photon avalanche emission in lanthanide-doped bulk crystals, PA emission has been achieved in nanometer-scale colloidal particles. The scaling of PA to nanomaterials has resulted in significant and rapid advances, such as luminescence imaging beyond the diffraction limit of light, optical thermometry and force sensing with (sub)micron spatial resolution, and all-optical data storage and processing. In this review, we discuss the fundamental principles underpinning PA and survey the studies leading to the development of nanoscale PA. Finally, we offer a perspective on how this knowledge can be used for the development of next-generation PA nanomaterials optimized for a broad range of applications, including mid-IR imaging, luminescence thermometry, (bio)sensing, optical data processing and nanophotonics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ocean water color assessment from ERTS-1 RBV and MSS imagery

The author has identified the following significant results. Photo-optical and electronic density slicing were applied to ERTS-1 E 1007-151651-4, 30 July 1972, an area in the Caribbean showing deep ocean water, and shallow areas on the Great Baham Bank ranging from 0.5 meter or less to 18 meters. The density slicing processes were adjusted to correlate water radiance to bathmetric contours shown on C and GS Chart 1112. A number of large areas corresponding to water depths of 2 meters or less, 5 to 10 meters, and 10 to about 20 meters were isolated by both processes. Where clear water and uniformly reflective bottom was found, clear of marine growths, the photo-optical and electronic image density slicing processes proved effective in delineating areas where the depth was in the order of 5 meters, plus or minus 1 meter.

Ross, D. S.↗

Enhanced spatial resolution of Eljen-204 plastic scintillators for use in rep-rated proton diagnostics

A pixelated scintillator has been designed, fabricated, and tested using a laser-accelerated proton source for use in proton diagnostics at rep-rated laser facilities. The work presented here demonstrates the enhanced spatial resolution of thin, organic scintillators through a novel pixelation technique. Furthermore, experimental measurements using laser-generated protons incident onto 130 μm-thick scintillators indicate a >20% reduction in the scintillator point spread function (PSF) for the detectors tested. The best performing pixelated detector reduced the ~200 μm PSF of the stock material to ~150 μm. The fabrication technique may be tailored to reduce the pixel size and achieve higher spatial resolutions.

47 OTHER INSTRUMENTATION↗