Search NASA⌕ Search

SEARCH · Search NASA

Results for “Incubation temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

115 records · Page 7

Development of a Two Dimensional Synthetic Aperture Radiometer at L-Band

A radiometer that uses aperture synthesis in two dimensions is being built as part of research under NASA's Instrument Incubator Program. The instrument development team consists of engineers at the Goddard Space Flight Center, the University of Massachusetts and Quadrant Engineering. This will be an aircraft instrument operating at L-band which builds on the heritage of Electronically Steered Thinned Array Radiometer (ESTAR). This instrument is a next step in the development of aperture synthesis (STAR technology) to meet the goal of a future mission to monitor soil moisture globally from space. The instrument will be designed to fly on the NASA P-3 aircraft in a nadir pointing mode, although other options are possible. The antenna will consist of an array of modules in a rectangular grid. Each module will be comprised of a printed circuit dual-polarized patch and integrated receiver. The distribution of modules within the rectangular array will be adjustable so that several different imaging configurations (e.g. '+', 'Y', 'T') can be employed. The integrated receiver will provide amplification and conversion to infrared (IF). The IF signal will be routed to a processor where the required correlations performed. The I and Q channels will be created digitally and the correlations will be done digitally in this processor. The digitization will be done with sufficient bits to study the effects of quantization on radiometer performance. A computer/controller will store the data for conversion to an image and will also perform temperature control and other data interfacing and housekeeping tasks. The design of critical components has been completed and hardware is being assembled to test the individual elements. It is expected that a complete two-channel correlator will be tested by the end of 2000 and that the complete instrument will be ready for flight tests the following summer (2001).

LeVine, D. M.↗

MISTiC Winds, a Micro-Satellite Constellation Approach to High Resolution Observations of the Atmosphere Using Infrared Sounding and 3D Winds Measurements

MISTiC(TM) Winds is an approach to improve short-term weather forecasting based on a miniature high resolution, wide field, thermal emission spectrometry instrument that will provide global tropospheric vertical profiles of atmospheric temperature and humidity at high (3-4 km) horizontal and vertical ( 1 km) spatial resolution. MISTiCs extraordinarily small size, payload mass of less than 15 kg, and minimal cooling requirements can be accommodated aboard a 27U-class CubeSat or an ESPA-Class micro-satellite. Low fabrication and launch costs enable a LEO sunsynchronous sounding constellation that would collectively provide frequent IR vertical profiles and vertically resolved atmospheric motion vector wind observations in the troposphere. These observations are highly complementary to present and emerging environmental observing systems, and would provide a combination of high vertical and horizontal resolution not provided by any other environmental observing system currently in operation. The spectral measurements that would be provided by MISTiC Winds are similar to those of NASA's AIRS that was built by BAE Systems and operates aboard the AQUA satellite. These new observations, when assimilated into high resolution numerical weather models, would revolutionize short-term and severe weather forecasting, save lives, and support key economic decisions in the energy, air transport, and agriculture arenasat much lower cost than providing these observations from geostationary orbit. In addition, this observation capability would be a critical tool for the study of transport processes for water vapor, clouds, pollution, and aerosols. Key remaining technical risks are being reduced through laboratory and airborne testing under NASA's Instrument Incubator Program.

Maschhoff, K. R.↗

Development of a Two Dimensional Synthetic Aperture Radiometer at L-Band

A radiometer that uses aperture synthesis in two dimensions is being built as part of research under NASA's Instrument Incubator Program. The instrument development team consists of engineers at the Goddard Space Flight Center, the University of Massachusetts and Quadrant Engineering. This will be an aircraft instrument operating at L-band which builds on the heritage of ESTAR. The choice of L-band was made because the problem of achieving adequate resolution in space is most critical at this wavelength and because a polarimetric, conical scanning airborne radiometer for future experiments to validate soil moisture and ocean salinity retrieval algorithms is not currently available. The instrument will be designed to fly on the NASA P-3 aircraft in a nadir pointing mode, although other options are possible. The antenna will consist of an array of modules arranged in a rectangular grid. Each module will be comprised of a printed circuit dual-polarized patch and integrated receiver. The distribution of modules within the rectangular array will be adjustable so that several different imaging configurations (e.g. "+","Y", "T") can be employed. The integrated receiver will provide amplification and conversion to IF. The IF signal will be routed to a processor where the required correlations performed. The I and Q channels will be created digitally and the correlations will be done digitally in this processor. The digitization will be done with sufficient bits to study the effects of quantization on radiometer performance. A computer/controller will store the data for conversion to an image and will also perform temperature control and other data interfacing and housekeeping tasks. The instrument is currently in the bread boarding phase of development. A design of the critical components has been completed and hardware is being assembled to test the individual elements. It is expected that a complete 2-channel correlator will be tested by the summer of 2000 and that the complete instrument will be ready for flight tests the following summer (2001).

LeVine, D. M.↗

Use of an adaptable cell culture kit for performing lymphocyte and monocyte cell cultures in microgravity

The results of experiments performed in recent years on board facilities such as the Space Shuttle/Spacelab have demonstrated that many cell systems, ranging from simple bacteria to mammalian cells, are sensitive to the microgravity environment, suggesting gravity affects fundamental cellular processes. However, performing well-controlled experiments aboard spacecraft offers unique challenges to the cell biologist. Although systems such as the European 'Biorack' provide generic experiment facilities including an incubator, on-board 1-g reference centrifuge, and contained area for manipulations, the experimenter must still establish a system for performing cell culture experiments that is compatible with the constraints of spaceflight. Two different cell culture kits developed by the French Space Agency, CNES, were recently used to perform a series of experiments during four flights of the 'Biorack' facility aboard the Space Shuttle. The first unit, Generic Cell Activation Kit 1 (GCAK-1), contains six separate culture units per cassette, each consisting of a culture chamber, activator chamber, filtration system (permitting separation of cells from supernatant in-flight), injection port, and supernatant collection chamber. The second unit (GCAK-2) also contains six separate culture units, including a culture, activator, and fixation chambers. Both hardware units permit relatively complex cell culture manipulations without extensive use of spacecraft resources (crew time, volume, mass, power), or the need for excessive safety measures. Possible operations include stimulation of cultures with activators, separation of cells from supernatant, fixation/lysis, manipulation of radiolabelled reagents, and medium exchange. Investigations performed aboard the Space Shuttle in six different experiments used Jurkat, purified T-cells or U937 cells, the results of which are reported separately. We report here the behaviour of Jurkat and U937 cells in the GCAK hardware in ground-based investigations simulating the conditions expected in the flight experiment. Several parameters including cell concentration, time between cell loading and activation, and storage temperature on cell survival were examined to characterise cell response and optimise the experiments to be flown aboard the Space Shuttle. Results indicate that the objectives of the experiments could be met with delays up to 5 days between cell loading into the hardware and initial in flight experiment activation, without the need for medium exchange. Experiment hardware of this kind, which is adaptable to a wide range of cell types and can be easily interfaced to different spacecraft facilities, offers the possibility for a wide range of experimenters successfully and easily to utilise future flight opportunities.

short duration↗

A METHOD TO REDUCE BIOBURDEN IN ASTROMATERIALS CURATION FACILITIES WITHOUT INTRODUCING UNWANTED CONTAMINATION

Introduction: NASA curates its Astromaterials collections in cleanrooms that are carefully monitored for particulate, inorganic and trace metal contamination. Current sample collections are not particularly susceptible to organic contamination or biological alteration. However, new collections like those from the OSIRIS-REx and Hayabusa2 missions will have organic contamination requirements and are susceptible to biodegradation. It will be necessary sterilize or at least disinfect curation labs, as well as tools and equipment in a manner that does not introduce additional contamination and does not affect the samples 1. Current curation cleaning procedures utilize isopropyl alcohol which offers some bioburden reduction, but is not effective against spore-forming bacteria or fungal spores 2. We present a modified disinfection method that uses ultrapure hydrogen peroxide to reduce bioburden inside curation labs and glove boxes without introducing contamination or damaging curation equipment. We tested this method in the meteorite processing lab as well as on a glovebox being cleaned for use in processing ANGSA (Apollo Next Generation Sample Analysis) samples and present the results of those tests. We discuss the limitations of this method and describe potential situations in which it will not be applicable. The CDC guidelines for disinfection andsterilization in healthcare facilities discusses over 15different methods for reducing bioburden in hospitalsettings 3. The most common method, steamsterilization, is well suited to sterilizing curationprocessing tools but cannot easily be used to sterilizecleanroom surfaces or large equipment likegloveboxes. Chemical sterilization with bleach(NaOCl) is also a common strategy in healthcare andpharmaceutical settings that presents materialcompatibility issues as well as serious inorganiccontamination concerns for curation facilities.Introducing a new source of Na and Cl into curationlabs is not acceptable. Other chemical methods likeethylene oxide, formaldehyde, iodophors andquaternary ammonium compounds could introduceorganic and inorganic contamination. We chose tofocus on hydrogen peroxide because it is generallycompatible with commonly used curation materialslike stainless steel, aluminum and Teflon and becauseit decomposes to oxygen and water. The CDCguidelines for hydrogen peroxide specify using a 7.5wt% solution at 25 ̊C with a contact time of 30 minutesfor high level disinfection and 6 hours for sterilization.High level disinfection is defined as a technique thatwill kill all microorganisms except large numbers ofbacterial spores 3. Methods: We prepared a solution of 7.5 wt%hydrogen peroxide from a stock solution of ultrapure30 wt% peroxide (JT Baker) and curation gradeultrapure water. This ultrapure water is already used incuration cleaning procedures and thus is not consideredand additional source of contamination. We conducteda materials compatibility test by exposing unanodizedand anodized 6061 T6 Al alloy to the peroxide solutionfor up to six hours and periodically inspecting thesurfaces for visible defects. We used this peroxide todisinfect the floor of the meteorite processing lab andthe interior of a curation glovebox by exposing thesesurfaces to the peroxide solution for 30 min. Thesurfaces were swabbed with a dry macrofoam swabbefore (Puritan Brand 2518051PFRNDFD) and afterperoxide treatment to collect microbes present on thesurfaces. Microbes were extracted by sonication fromthe swab into 15 ml of PBS (phosphate buffered saline)and inoculated onto the following media: TSA (trypticsoy agar) BA (blood agar), R2A (Reasoners 2 agar),Potato Dextrose Agar, Saboraud Dextrose Agar andSaboraud Dextrose Agar with 0.1 mg/ mlchloramphenicol. Four TSA plates and two BA plateswere inoculated with 0.1 ml of PBS each andincubated at 35 and 37 for 48 hours. Two R2A°C°Cplates (0.1 ml of PBS each) were incubated at 25 .°CThe remaining plates were inoculated with 0.2ml ofPBS and incubated at 30 ̊C for seven days. Afterincubation bacterial and fungal isolates were countedand transferred to new plates for identification usingthe VITEK24 automated system or by sequencing aportion of the barcode gene (16S rRNA for bacteria,small subunit gene for fungi) on an ABI 3500 Sangersequencer. Negative controls consisted of swabs thatwere opened in the sampling environment andanalyzed alongside the experimental samples.Results: A 6 hour exposure to hydrogen peroxideresulted in visible pitting on un-anodized 6061 Al, butnot on anodized surfaces. No visible pitting occurredafter a 30 minute exposure. Therefore, we decided tolimit our experimental tests to 30 min. exposures. 17bacterial CFU (colony forming units) representing 4distinct organisms were isolated from the meteorite processing lab floor prior to hydrogen peroxidetreatment. We were unable culture any organisms afterperoxide treatment. In the glovebox we were able toculture three bacterial CFU representing three distinctspecies, including a spore forming bacterium prior todisinfection with peroxide. After the peroxidetreatment we were unable to culture any organisms.Routine monitoring of the meteorite processing lab andthe glovebox did not indicate any increase in unwantedinorganic contamination after these peroxidetreatments. Discussion: A 30 minute treatment with 7.5 wt%peroxide appears to be an effective method forreducing bioburden on typical cleanroom surfaces. Themethod does not introduce unwanted organic orinorganic contamination and is compatible withcommonly used curation materials like stainless steel,Teflon and anodized aluminum alloys. Special careshould be taken with un-anodized aluminum.Prolonged exposure to hydrogen peroxide can causepitting on this material. We recommend using thismethod to disinfect curation labs and equipment whenbiological alteration is a concern. This method iseffective at room temperature and cannot be used todisinfect labs and equipment where the ambienttemperature is < 0 ̊C. Astromaterials samples shouldbe removed from the area where disinfection is tooccur. Hydrogen peroxide is a powerful oxidizingagent and will react with any organic carbon present inthe sample. References: [1.] Mccubbin, F. M. et al.Sp. Sci Rev(2019) doi:10.1007/s11214-019-0615-9. [2.] Mogul, R.et al.Astrobiology 18, ast.2017.1814 (2018). [3.]Rutala, W. A. & Weber, D. J. Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008. [4.] Pincus, D. H. in Encyclopedia of Rapid Microbiological Methods (2005).

A. B. Regberg↗

Mineral induction by immobilized phosphoproteins

Dentin phosphoproteins are thought to have a primary role in the deposition of mineral on the collagen of dentin. In this study we determined the type of binding between collagen and phosphoproteins necessary for mineral formation onto collagen fibrils and whether the phosphate esters are required. Bovine dentin phosphophoryn or phosvitin from egg yolk were immobilized on reconstituted skin type I collagen fibrils by adsorption or by covalent cross-linking. In some samples the ester phosphate was removed from the covalently cross-linked phosphoproteins by treatment with acid phosphatase. All samples were incubated at 37 degrees C in metastable solutions that do not spontaneously precipitate. Reconstituted collagen fibrils alone did not induce mineral formation. The phosphoproteins adsorbed to the collagen fibrils desorbed when the mineralization medium was added, and mineral was not induced. The mineral induced by the cross-linked phosphoproteins was apatite, and the crystals were confined to the surface of the collagen fibrils. With decreasing medium saturation the time required for mineral induction increased. The interfacial tensions calculated for apatite formation by either phosphoprotein cross-linked to collagen were about the same as that for phosphatidic acid liposomes and hydroxyapatite. This similarity in values indicates that the nucleation potential of these highly phosphorylated surfaces is about the same. It is concluded that phosphoproteins must be irreversibly bound to collagen fibrils for the mineralization of the collagen network in solutions that do not spontaneously precipitate. The phosphate esters of phosphoproteins are required for mineral induction, and the carboxylate groups are not sufficient.

Non-NASA Center↗

Understanding and Utilizing PBL Height Data from Multiple Observing Systems in the GEOS System

The accuracy of PBL height simulation is a key issue in many applications including forecasting near surface meteorology and air quality, however, it is a very challenging problem due to the lack of not only comprehensive, global Planetary Boundary Layer (PBL) observations but also a strategy and infrastructure to utilize PBL height data from a variety of sensors. Following the designation of PBL as an incubation class observable in the 2017 Decadal Survey, the PBL Incubation Study Team Report [14] made clear that “a future global PBL observing system requires modeling and data assimilation as essential components.” There is an urgent need for global modeling development in order to utilize Program of Record (POR) observations, assess their impacts, and identify gaps to be filled by future PBL missions. Our overall objective is to develop PBL data assimilation capabilities in the NASA Global Earth Observing System (GEOS), focusing on PBL height from multiple observing systems, to support the assessment and use of future PBL observations. The NASA GEOS system is composed of the GEOS global atmospheric general circulation model (AGCM) and the atmospheric data assimilation system (ADAS). The PBL parameterizations include the “Lock” K-profile scheme driven by surface and cloud-top buoyancy fluxes ([4]), and the “Louis” local scheme for stable conditions based on the Richardson number ([5]). Above the mixed layer defined by the Lock surface plume, shallow cumulus convection is represented by the mass flux scheme of [9]. Additional parameterizations are summarized in [1]. The ADAS employs the hybrid 4D Ensemble- Variational (EnVar) configuration ([15]), with the ensemble providing flow-dependent background error covariance information. The resultant analysis increments are fed back to the forecast model through the 4D incremental analysis update (IAU) approach ([11]). In this study, PBL height data are being or have been generated from radiosondes, GNSS RO, satellite (CATS, CALIPSO and ICESat-2) and ground-based (MPLNET) lidars, and wind profiler. Investigations have been conducted to specify quality marks for PBL height retrievals for the data assimilation purpose. These PBL height data have different strengths and weaknesses ([2], [3], [6], [7], [8], [10]), and the satellite PBL height data provide better global coverage and complement in-situ PBL height data. Radiosondes offer high accuracy and in situ measurement of temperature and humidity profiles, but with poor spatio-temporal sampling. The in-situ observing systems like MPLNET and wind profiler provide long history of PBL height records at each station. The GNSS RO based PBL height is retrieved based on the sharp gradients in refractivity profile that represent the fine vertical structure of temperature and moisture changes above the PBL. However, not all RO refractivity profiles reach the surface depending on location and regime, and RO refractivity retrievals can be negatively biased below 2km. The PBL height data from satellite lidars provide high resolution along track PBL height retrievals, but over land they are affected by previous day convective PBL aerosol and strongly associated with mixing layer and retrievals cannot be made below thick, attenuating clouds. A successful assimilation of PBL height data requires a thorough understanding of the observing method and the retrieval algorithm for each observing system in order to use the PBL height data from multiple observing systems properly. Due to the sensitivity of PBL height data to the observing method and choice of algorithm, it is important to use a model definition appropriate for each observation type to compute differences between PBL height data and model PBL height (OmFs). The GEOS model currently includes two PBL height definitions suitable for direct comparison with observed PBL height, and additional definitions are being added in this study. Evaluation of different model PBL height definitions is underway. Meanwhile, efforts have been made in the GEOS data assimilation system to develop PBL height data assimilation capability. PBL height data can be assimilated using two different approaches. The traditional approach is to construct an observation operator and its tangent linear and adjoint, which link control variables to PBL height data from each observing system. This observation operator can be very complicated, e.g., the lidar-based PBL height observation operator includes the backscatter lidar forward observation operator, the algorithm to derive PBL height from attenuated total backscatter, interpolation, and calculations handling the mismatch between observed and model scales. The other approach is to augment PBL height to the control variable vector, and it is adopted in this study. The latter approach was also used in previous studies, e.g., the assimilation of PBL height data from radiosonde and aircraft in the Real Time Mesoscale Analysis (RTMA) system for a dispersion modelling study ([13]); the PBL height assimilation study using lidar PBL height data at Greensburg, Kansas for a field campaign ([12]). The PBL height assimilation from multiple observing systems in this study allows us to take advantage of the diverse PBL height data that provide much better global coverage collectively under different meteorological conditions and with different temporal and spatial scales. As all the PBL heights are tightly coupled with the PBL thermodynamic variables, the strong correlations, which are provided by the 4D ensemble forecast, enable PBL height data from various sources to interact and combine coherently and provide additional information for PBL temperature and moisture fields. The results of comparisons among PBL height data from different sources and the evaluation of the model PBL height definitions with the PBL height data will be presented, and the PBL height data synergy strategies and preliminary results will also be discussed at the conference.

Y. Zhu↗