Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inhalation Dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The development and use of decision support framework for informing selection of select agent toxins with modelling studies to inform permissible toxin amounts

Many countries have worked diligently to establish and implement policies and processes to regulate high consequence pathogens and toxins that could have a significant public health impact if misused. In the United States, the Antiterrorism and Effective Death Penalty Act of 1996 (Public Law 104-132, 1996), as amended by the Bioterrorism Preparedness and Response Act of 2002 (Public Law 107-188, 2002) requires that the Department of Health and Human Services (HHS) [through the Centers for Disease Control and Prevention (CDC)] establish a list of bacteria, viruses, and toxins that have the potential to pose a severe threat to public health and safety. Currently, this list is reviewed and updated on a biennial basis using input from subject matter experts (SMEs). We have developed decision support framework (DSF) approaches to facilitate selection of select toxins and, where toxicity data are known, conducted modelling studies to inform selection of toxin amounts that should be excluded from select agent regulations. Exclusion limits allow laboratories to possess toxins under an established limit to support their research or teaching activities without the requirement to register with the Federal Select Agent Program. Fact sheets capturing data from a previously vetted SME workshop convened by CDC, literature review and SME input were developed to assist in evaluating toxins using the DSF approach. The output of the DSF analysis agrees with the current select toxin designations, and no other toxins evaluated in this study were recommended for inclusion on the select agent and toxin list. To inform the selection of exclusion limits, attack scenarios were developed to estimate the amount of toxin needed to impact public health. Scenarios consisted of simulated aerosol releases of a toxin in high-population-density public facilities and the introduction of a toxin into a daily consumable product supply chain. Using published inhalation and ingestion median toxic dose (TD 50 ) and median lethal dose (LD 50 ) values, where available, a range of toxin amounts was examined to estimate the number of people exposed to these amounts in these scenarios. Based on data generated by these models, we proposed toxin exclusion values corresponding to levels below those that would trigger a significant public health response (i.e., amounts estimated to expose up to ten people by inhalation or one hundred people by ingestion to LD 50 or TD 50 levels of toxin in the modeled scenarios).

60 APPLIED LIFE SCIENCES↗

Conclusions of the Capstone Depleted Uranium Aerosol Characterization and Risk Assessment Study

The rationale for the Capstone Depleted Uranium (DU) Aerosol Characterization and Risk Assessment Program and its results and applications have been examined in the previous 13 articles of this special issue. This paper summarizes the results and discusses its successes and lessons learned. The robust data from the Capstone DU Aerosol Study have provided a sound basis for assessing the inhalation exposure to DU aerosols and the dose and risk to personnel in combat vehicles at the time of perforation and to those entering immediately after perforation. The Human Health Risk Assessment provided a technically sound process for evaluating chemical and radiological doses and risks from DU aerosol exposure using well-accepted biokinetic and dosimetric models innovatively applied. An independent review of the study process and results is summarized, and recommendations for possible avenues of future study by the authors and by other major reviews of DU health hazards are provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Site-Specific Reference Person Parameters and Derived Concentration Standards for the Savannah River Site

The U.S. Department of Energy Order 458.1 states that the compliance with the 1 mSv annual dose constraint to a member of the public may be demonstrated by calculating dose to the maximally exposed individual (MEI) or to a representative person. Historically, the MEI concept was used for dose compliance at the Savannah River Site (SRS) using adult dose coefficients and adult male usage parameters. For future compliance, SRS plans to use the representative person concept for dose estimates to members of the public. The representative person dose will be based on the reference person dose coefficients from the U.S. DOE Derived Concentration Technical Standard and on usage parameters specific to SRS for the reference and typical person. Usage parameters and dose coefficients were determined for inhalation, ingestion and external exposure pathways. The parameters for the representative person were used to calculate and tabulate SRS-specific derived concentration standards (DCSs) for the pathways not included in DOE-STD-1196-2011.

54 ENVIRONMENTAL SCIENCES↗

Basis for the ICRP’s updated biokinetic model for carbon inhaled as CO 2

Here, the International Commission on Radiological Protection (ICRP) is updating its biokinetic and dosimetric models for occupational intake of radionuclides (OIR) in a series of reports called the OIR series. This paper describes the basis for the ICRP's updated biokinetic model for inhalation of radiocarbon as carbon dioxide (CO 2 ) gas. The updated model is based on biokinetic data for carbon isotopes inhaled as carbon dioxide or injected or ingested as bicarbonate $({{{\rm{HCO}}}_{3}}^{-}).$ The data from these studies are expected to apply equally to internally deposited (or internally produced) carbon dioxide and bicarbonate based on comparison of excretion rates for the two administered forms and the fact that carbon dioxide and bicarbonate are largely carried in a common form (CO 2 –H${{{\rm{CO}}}_{3}}^{-})$ in blood. Compared with dose estimates based on current ICRP biokinetic models for inhaled carbon dioxide or ingested carbon, the updated model will result in a somewhat higher dose estimate for 14 C inhaled as CO 2 and a much lower dose estimate for 14 C ingested as bicarbonate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Verification of RESRAD-BUILD Code Version 4

This report documents the verification of the RESRAD-BUILD code, Version 4.0, which was released on December 22, 2022. Two earlier reports verifying Versions 3.0 and 3.1, respectively, were published in 2001 (Kamboj, et al. 2001) and 2003 (Tetra Tech NUS 2003). Version 4.0 of the RESRAD-BUILD code has many new features and modeling enhancements over the earlier versions, including the previously released Version 3.5. Chapter 2 of this report focuses on verifying the external dose and risk modeling for point, line, area, and volume sources, as well as for floor deposition. Besides verification, the external radiation doses calculated by RESRAD-BUILD were also benchmarked with those calculated by the MCNP code (Briemeister 1993). Section J.3 of the RESRAD-BUILD User’s Manual Vol. 1 (Yu et al. 2022) documents the results of that benchmarking effort. Chapter 3 of this report focuses on verifying the ventilation modeling, from checking the remaining source inventory, releases of radionuclides to the air, air concentrations and deposited floor concentrations over time, to the radiation dose and risk associated with inhalation, ingestion, and air submersion, with and without vacuuming. The verification efforts involve designing spreadsheets to perform calculations the same as or like those performed by the RESRAD-BUILD code and then comparing the spreadsheet results with those produced by the code. When the results agree or the differences are within acceptable range, the accuracy of model implementation in the code is verified. In addition to model implementation, the implementation of key functions and features that facilitate the modeling or the use of the code were also verified during the release testing of the code. Appendix A presents the test cases developed for these verification testing, and Appendix B presents the testing results that verify proper implementation of key functions and features.

54 ENVIRONMENTAL SCIENCES↗

Influence of Manufacturing Processes on the Performance of Phantom Lungs

Chest counting is an important tool for estimating the radiation dose to individuals who have inhaled radioactive materials. Chest counting systems are calibrated by counting the activity in the lungs of phantoms where the activity in the phantom lungs is known. In the United States a commonly used calibration phantom was developed at the Lawrence Livermore National Laboratory and is referred to as the Livermore Torso Phantom. An important feature of this phantom is that the phantom lungs can be interchanged so that the counting system can be challenged by different combinations of radionuclides and activity. Phantom lungs are made from lung tissue substitutes whose constituents are foaming plastics and various adjuvants selected to make the lung tissue substitute similar to normal healthy lung tissue. Some of the properties of phantom lungs cannot be readily controlled by phantom lung manufacturers. Some, such as density, are a complex function of the manufacturing process, while others, such as elemental composition of the bulk plastic are controlled by the plastics manufacturer without input, or knowledge of the phantom manufacturer. Despite the fact that some of these items cannot be controlled, they can be measured and accounted for. This report describes how manufacturing processes can influence the performance of phantom lungs. It is proposed that a metric that describes the brightness of the lung be employed by the phantom lung manufacturer to determine how well the phantom lung approximates the characteristics of a human lung. For many purposes, the linear attenuation of the lung tissue substitute is an appropriate surrogate for the brightness.

61 RADIATION PROTECTION AND DOSIMETRY↗

Air Exchange Rate Impact on Activity Equilibrium Factors and Inhalation Fractional Equilibrium Factors for Rn, Xe, Kr, Ar, Ne, and Their Progeny in Vapor Intrusion, Risk, and Dose Models

Exposure to the radioactive noble gasses, especially radon, is of high concern and poses a significant risk to humans in an indoor air environment as the second leading cause of lung cancer in the United States. To evaluate and minimize the risks posed by these gasses, it is important to understand their radiological and physical properties. The EPA’s Radon Vapor Intrusion Screening Level (RVISL) calculator calculates indoor air RVISLs based on target working levels (WLs), target excess lifetime cancer risk (ELCR), and annual dose limits for the actinon (Rn-219), thoron (Rn-220), and radon (Rn-222) decay series. The RVISLs are based on inhalation and submersion in gas cloud exposure routes for residential and commercial settings. The RVISLs are analogous to preliminary remediation goals (PRGs) and dose compliance concentrations (DCCs), where the isotope-specific values are in units of activity concentration (activity per unit volume). If the concentration of a parent isotope of radon or its progeny is found to exceed the RVISL, then further action to ensure cleanup of the contaminant may be necessary. In residential and commercial settings, the RVISLs will vary based on the air exchange rate present. The EPA’s Radionuclide PRG and DCC Calculators also assess the risk/dose from noble gases in the air due to household use of water like showering. In this study, a computational method in MATLAB was developed to determine the impact of the air exchange rate on the activity equilibrium factor (A eq ) and the inhalation fractional equilibrium factor (F eq ). Both factors are values that reflect the equilibrium concentrations of progeny to their parent in the air. These factors have a direct impact on the RVISL, PRG, and DCC calculations of WL, ELCR, and annual dose, respectively. This study builds on a previous report that only focused on actinon, thoron, and radon by revisiting the original A eq and F eq calculation methods, as well as including the values for the Rn-207, Rn-209, Rn-210, Rn-211, Rn-215, Rn-216, Rn-217, Rn-218, Rn-223, Ne-24, Ar-42, Ar-43, Ar-44, Kr-74, Kr-75, Kr-76, Kr-77, Kr-88, Kr-89, Xe-120, Xe-121, Xe-122, Xe-123, Xe-135m, and Xe-138 decay chains, which are not currently available in literature. The EPA’s RVISL calculator will be updated to include the new A eq and F eq values for the actinon, thoron, and radon decay chains, while the rest of the calculators will incorporate all the new A eq and F eq values as appropriate.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Acute respiratory changes and pulmonary inflammation involving a pathway of TGF-β1 induction in a rat model of chlorine-induced lung injury

We investigated acute and delayed respiratory changes after inhalation exposure to chlorine (Cl{sub 2}) with the aim to understand the pathogenesis of the long-term sequelae of Cl{sub 2}-induced lung-injury. In a rat model of nose-only exposure we analyzed changes in airway hyperresponsiveness (AHR), inflammatory responses in airways, expression of pro-inflammatory markers and development of lung fibrosis during a time-course from 5 h up to 90 days after a single inhalation of Cl{sub 2}. A single dose of dexamethasone (10 mg/kg) was administered 1 h following Cl{sub 2}-exposure. A 15-min inhalation of 200 ppm Cl{sub 2} was non-lethal in Sprague-Dawley rats. At 24 h post exposure, Cl{sub 2}-exposed rats displayed elevated numbers of leukocytes with an increase of neutrophils and eosinophils in bronchoalveolar lavage (BAL) and edema was shown both in lung tissue and the heart. At 24 h, the inflammasome-associated cytokines IL-1β and IL-18 were detected in BAL. Concomitant with the acute inflammation a significant AHR was detected. At the later time-points, a delayed inflammatory response was observed together with signs of lung fibrosis as indicated by increased pulmonary macrophages, elevated TGF-β expression in BAL and collagen deposition around airways. Dexamethasone reduced the numbers of neutrophils in BAL at 24 h but did not influence the AHR. Inhalation of Cl{sub 2} in rats leads to acute respiratory and cardiac changes as well as pulmonary inflammation involving induction of TGF-β1. The acute inflammatory response was followed by sustained macrophage response and lack of tissue repair. It was also found that pathways apart from the acute inflammatory response contribute to the Cl{sub 2}-induced respiratory dysfunction. - Highlights: • Inhalation of Cl{sub 2} leads to acute lung inflammation and airway hyperreactivity. • Cl{sub 2} activates an inflammasome pathway of TGF-β induction. • Cl{sub 2} leads to a fibrotic respiratory disease. • Treatment with corticosteroids alone is insufficient to counteract acute lung injury.

60 APPLIED LIFE SCIENCES↗

A biokinetic model for manganese for use in radiation protection

The ICRP is updating its recommendations regarding occupational exposure to radionuclides including the biokinetic models used to derive dose coefficients and assess bioassay data for internally deposited radionuclides. This report reviews biokinetic data for manganese and proposes a biokinetic model for systemic manganese consistent with the current database. The model provides a more detailed and biologically realistic description of the movement of absorbed manganese in the body than the model currently recommended by the International Commission on Radiological Protection (ICRP). The proposed model and current ICRP model yield broadly similar estimates of dose per unit activity of inhaled or ingested radio-manganese but differ substantially with regard to interpretation of bioassay data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiological Dose Calculations And Supplemental Dose Assessment Data For Neshap Compliance For SNL Nevada Facilities 1996.

Operations of Sandia National Laboratories, Nevada (SNL/NV) at the Tonopah Test Range (TTR) resulted in no planned point radiological releases during 1996. Other releases from SNL/NV included diffuse transuranic sources consisting of the three Clean Slate sites. Air emissions from these sources result from wind resuspension of near-surface transuranic contaminated soil particulates. The total area of contamination has been estimated to exceed 20 million square meters. Soil contamination was documented in an aerial survey program in 1977 (EG&G 1979). Surface contamination levels were generally found to be below 400 pCi/g of combined plutonium-238, plutonium-239, plutonium-240, and americium-241 (i.e., transuranic) activity. Hot spot areas contain up to 43,000 pCi/g of transuranic activity. Recent measurements confirm the presence of significant levels of transuranic activity in the surface soil. An annual diffuse source term of 0.39 Ci of transuranic material was calculated for the cumulative release from all three Clean Slate sites. A maximally exposed individual dose of 1.1 mrem/yr at the TTR airport area was estimated based on the 1996 diffuse source release amounts and site-specific meteorological data. A population dose of 0.86 person-rem/yr was calculated for the local residents. Both dose values were attributable to inhalation of transuranic contaminated dust.

61 RADIATION PROTECTION AND DOSIMETRY↗

A planning study investigating dual-gated volumetric arc stereotactic treatment of primary renal cell carcinoma

This is a planning study investigating the dosimetric advantages of gated volumetric-modulated arc therapy (VMAT) to the end-exhale and end-inhale breathing phases for patients undergoing stereotactic treatment of primary renal cell carcinoma. VMAT plans were developed from the end-inhale (VMATinh) and the end-exhale (VMATexh) phases of the breathing cycle as well as a VMAT plan and 3-dimensional conformal radiation therapy plan based on an internal target volume (ITV) (VMATitv). An additional VMAT plan was created by giving the respective gated VMAT plan a 50% weighting and summing the inhale and exhale plans together to create a summed gated plan. Dose to organs at risk (OARs) as well as comparison of intermediate and low-dose conformity was evaluated. There was no difference in the volume of healthy tissue receiving the prescribed dose for the planned target volume (PTV) (CI100%) for all the VMAT plans; however, the mean volume of healthy tissue receiving 50% of the prescribed dose for the PTV (CI50%) values were 4.7 (± 0.2), 4.6 (± 0.2), and 4.7 (± 0.6) for the VMATitv, VMATinh, and VMATexh plans, respectively. The VMAT plans based on the exhale and inhale breathing phases showed a 4.8% and 2.4% reduction in dose to 30 cm{sup 3} of the small bowel, respectively, compared with that of the ITV-based VMAT plan. The summed gated VMAT plans showed a 6.2% reduction in dose to 30 cm{sup 3} of the small bowel compared with that of the VMAT plans based on the ITV. Additionally, when compared with the inhale and the exhale VMAT plans, a 4% and 1.5%, respectively, reduction was observed. Gating VMAT was able to reduce the amount of prescribed, intermediate, and integral dose to healthy tissue when compared with VMAT plans based on an ITV. When summing the inhale and exhale plans together, dose to healthy tissue and OARs was optimized. However, gating VMAT plans would take longer to treat and is a factor that needs to be considered.

61 RADIATION PROTECTION AND DOSIMETRY↗

Area Factor Determinations for an Industrial Worker Exposed to a Concrete Slab End-State

The U.S. Department of Energy's (DOE) Savannah River Site (SRS) is decommissioning many of its excess facilities through removal of the facility structures leaving only the concrete-slab foundations in place. Site-specific, risk-based derived concentration guideline levels (DCGLs) for radionuclides have been determined for a future industrial worker potentially exposed to residual contamination on these concrete slabs as described in Jannik. These risk-based DCGLs were estimated for an exposure area of 100 m{sup 2}. During deactivation and decommissioning (D and D) operations at SRS, the need for area factors for larger and smaller contaminated areas arose. This paper compares the area factors determined for an industrial worker exposed to a concrete slab end-state for several radionuclides of concern at SRS with 1) the illustrative area factors provided in MARSSIM, 2) the area correction factors provided in the U.S. Environmental Protection Agency's (EPA) Soil Screening Guidance, and 3) the hot spot criterion for field application provided in the RESRAD User's Manual. The purpose of this site-specific assessment is to determine if any of the recommended area factors provided in the guidance documents could be utilized at SRS for field applications of the industrial worker DCGLs. Results show the area factors that were determined for an SRS industrial worker exposed to concrete slab end-states for the common radionuclides provided in the referenced guidance documents. In addition to the SRS site-specific area factors, the following area factors are provided for comparison: - Illustrative examples of outdoor area dose factors (MARSSIM); - Area correction factors as a function of source area (Soil Screening Guidance). Note: the area correction factors were inverted to correspond to a DCGL area factor. - Recommended area correction factors as a function of source area (Soil Screening Guidance); - Ranges for hot spot multiplication factors (RESRAD). As it can be seen, because the MARSSIM area factors are highly affected by ingestion and inhalation pathways, they do not compare well with the SRS area factors. The Soil Screening Guidance area factors are in general more conservative than the SRS area factors because they are based exclusively on external exposures. The RESRAD multiplication factors (though limited to area less than 25 m{sup 2}), are in general more conservative than the SRS area factors but compare well with them. These are the factors that were recommended for use in SRS D and D projects field applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Translating nanoparticle dosimetry from conventional in vitro systems to occupational inhalation exposures

As encouraged by Toxicity Testing in the 21st Century, researchers increasingly apply high-throughput in vitro approaches to identify and characterize nanoparticle hazards, including conventional aqueous cell culture systems to assess respiratory hazards. Translating nanoparticle dose from conventional toxicity testing systems to relevant human exposures remains a major challenge for assessing occupational risk of nanoparticle exposures. Here, we explored existing computational tools and data available to translate nanoparticle dose metrics from cellular test systems to inhalation exposures of silver nanoparticles in humans. We used the Multiple-Path Particle Dosimetry (MPPD) Model to predict deposition of humans exposed to 20 and 110 nm silver nanoparticles at 0.9 µg/m3 over an 8 hr period, the proposed a National Institute of Occupational Safety and Health (NIOSH) recommended exposure limit (REL). MPPD predicts 1.88 and 0.98 µg of silver deposited in an 8 hr period for 20 and 110 nm nanoparticles, respectively, with 20 nm particles displaying nearly 11-fold higher total surface area deposited. Peak nanoparticle concentrations occurred more proximal in the pulmonary tract compared to mass deposition patterns (generation 5 vs. generations 20-21, respectively) due to regional differences in lung lining fluid volumes. Assuming 0.4% nanoparticle dissolution by mass as previously measured, we predict peak concentrations of silver ions in cells of 0.24 and 0.17 µg/mL for 20 and 110 nm particles, respectively. Both predicted concentrations are below the measured toxic threshold of 1.7 µg/mL of silver ions in cells from in vitro assessments. Assuming 4% dissolution by mass, we predict 10-fold higher silver concentrations in tissues, peaking at 2.4 and 1.7 µg/mL, for 20 and 110 nm nanoparticles respectively, exceeding the observed in vitro toxic threshold and highlighting the importance and sensitivity of dissolution rates. Overall, this approach offers a framework for extrapolating nanotoxicity results from in vitro cell culture systems to human exposures. Aligning appropriate dose metrics from in vitro and in vivo hazard characterizations and human pulmonary doses from occupational exposures are critical components for successful nanoparticle risk assessment and worker protection and provide guidance for designing future in vitro studies aimed at relevant human exposures.

Smith, Jordan N.↗

Four-Dimensional Treatment Planning for Stereotactic Body Radiotherapy

Purpose: To investigate the influence of tumor motion on the calculation of four-dimensional (4D) dose distributions of the gross tumor volume (GTV) in pulmonary stereotactic body radiotherapy. Methods and Materials: For 7 patients with eight pulmonary tumors, a respiratory-correlated 4D-computed tomography study was acquired. The internal target volume was the sum of all tumor positions in the planning 4D-computed tomography study, and a 5-mm margin was used for generation of the planning target volume. Three-dimensional (3D) treatment plans were generated with a dose prescription of 3 x 12.5 Gy to the planning target volume enclosing the 65% and 80% isodose. After model-based nonrigid image registration, the 4D dose distributions were calculated. Results: No significant difference was found in the dose to the GTV with the tumor in the end-exhalation, end-inhalation, or mid-ventilation phase of the breathing cycle. The high-dose region was confined to the solid tumor, and lower doses were delivered to the surrounding pulmonary tissue of lower density. This nonstatic, variant dose distribution increased the 4D dose to the GTV by 6.2%, on average, compared with calculations using on a static dose distribution during the breathing cycle. The 4D accumulation resulted in a biologic effective dose (BED) of 143 {+-} 8 Gy and 106 {+-} 4 Gy to the GTV in the plan-65% and plan-80%, respectively. The dose to the ipsilateral lung was not different between the 3D and 4D dose calculations or between plan-65% and plan-80%. Conclusions: In this study, the dose to the GTV was not decreased or blurred in the 4D plan compared with the 3D plan. The 3D doses to the GTV, internal target volume, and dose at the isocenter were good approximations of the 4D dose calculations. The 3D dose at the planning target volume margin underestimated the 4D dose significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Disposition of smoked cannabis with high {Delta}{sup 9}-tetrahydrocannabinol content: A kinetic model

Introduction: No model exists to describe the disposition and kinetics of inhaled cannabis containing a high THC dose. We aimed to develop a kinetic model providing estimates of the THC serum concentrations after smoking cannabis cigarettes containing high THC doses (up to 69 mg THC). Methods: Twenty-four male non-daily cannabis users smoked cannabis cigarettes containing 29.3 mg, 49.1 mg, and 69.4 mg THC. Blood samples were collected over a period of 0-8 h and serum THC concentrations were measured. A two-compartment open model was fitted on the individual observed data. Results: Large inter-individual variability was observed in the pharmacokinetic parameters. The median pharmacokinetic parameters generated by the model were C{sub max} = 175 ng/mL, T{sub max} = 14 min, and AUC{sub 0-8h} = 8150 ng x min/mL for the 69.4 mg THC dose. Median model results show an almost linear dose response relation for C{sub max}/Dose = 2.8 x 10{sup -6}/mL and AUC{sub 0-8h}/Dose = 136 x 10{sup -6} min/mL. However, for increasing dose level, there was a clear decreasing trend: C{sub max}/Dose = 3.4, 2.6 and 2.5 x 10{sup -6}/mL and AUC{sub 0-8h}/Dose = 157, 133 and 117 x 10{sup -6} min/mL for the 29.3, 49.1 and 69.4 mg dose, respectively. Within the restriction of 8 h of observation, the apparent terminal half life of THC was 150 min. Conclusion: The model offers insight into the pharmacokinetics of THC in recreational cannabis users smoking cannabis containing high doses of THC mixed with tobacco. The model is an objective method for providing serum THC concentrations up to 8 h after smoking cannabis with a high THC content (up to 23%).

60 APPLIED LIFE SCIENCES↗

Rapid method to determine 226Ra in steel samples

The rapid measurement of 226 Ra in steel samples is very important in the event of a radiological emergency. 226 Ra (T 1/2 = 1600 y) is a natural radionuclide present in the environment and a highly toxic alpha-emitter. Due to its long life and tendency to concentrate in bones, 226 Ra ingestion or inhalation can lead to significant committed dose to individuals. A new method for the determination of 226 Ra in steel samples has been developed at the Savannah River Environmental Laboratory. The new method employs a rugged acid digestion method that includes hydrofluoric acid, followed by a single precipitation step to rapidly preconcentrate the radium and remove most of the dissolved steel sample matrix. Radium is then separated using a combination of cation exchange and extraction chromatography, and 226 Ra is measured by alpha spectrometry. This approach has a sample preparation time of ~ 8 h for steel samples, has a very high tracer yield (> 88%), and removes interferences effectively. A 133 Ba yield tracer is used so that samples can be counted immediately following the separation method, avoiding lengthy ingrowth times that are required in other methods.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Historical doses to the public from routine and accidental releases of tritium - Lawrence Livermore National Laboratory, 1953-2005

Throughout fifty-three years of operations, an estimated 29,300 TBq of tritium have been released to the atmosphere at the Livermore site of Lawrence Livermore National Laboratory; about 75% of this was released accidentally as gaseous tritium in 1965 and 1970. Routine emissions contributed slightly more than 3,700 TBq gaseous tritium and about 2,800 TBq tritiated water vapor to the total. Mean annual doses (with 95% confidence intervals) to the most exposed member of the public were calculated for all years using the same model and the same assumptions. Because time-dependent tritium models require detailed meteorological data that were unavailable for the large releases, ingestion/inhalation dose ratios were derived from experience with UFOTRI. Even with assumptions to assure that doses would not be underestimated, all doses from routine and accidental releases were below the level (3.6 mSv) at which adverse health effects have been documented, and most were below the current regulatory limit of 100 {mu}Sv per year from releases to the atmosphere. (authors)

54 ENVIRONMENTAL SCIENCES↗

Estimation of three-dimensional intrinsic dosimetric uncertainties resulting from using deformable image registration for dose mapping

Purpose: This article presents a general procedural framework to assess the point-by-point precision in mapped dose associated with the intrinsic uncertainty of a deformable image registration (DIR) for any arbitrary patient. Methods: Dose uncertainty is obtained via a three-step process. In the first step, for each voxel in an imaging pair, a cluster of points is obtained by an iterative DIR procedure. In the second step, the dispersion of the points due to the imprecision of the DIR method is used to compute the spatial uncertainty. Two different ways to quantify the spatial uncertainty are presented in this work. Method A consists of a one-dimensional analysis of the modules of the position vectors, whereas method B performs a more detailed 3D analysis of the coordinates of the points. In the third step, the resulting spatial uncertainty estimates are used in combination with the mapped dose distribution to compute the point-by-point dose standard deviation. The process is demonstrated to estimate the dose uncertainty induced by mapping a 62.6 Gy dose delivered on maximum exhale to maximum inhale of a ten-phase four-dimensional lung CT. Results: For the demonstration lung image pair, the standard deviation of inconsistency vectors is found to be up to 9.2 mm with a mean {sigma} of 1.3 mm. This uncertainty results in a maximum estimated dose uncertainty of 29.65 Gy if method A is used and 21.81 Gy for method B. The calculated volume with dose uncertainty above 10.00 Gy is 602 cm{sup 3} for method A and 1422 cm{sup 3} for method B. Conclusions: This procedure represents a useful tool to evaluate the precision of a mapped dose distribution due to the intrinsic DIR uncertainty in a patient. The procedure is flexible, allowing incorporation of alternative intrinsic error models.

60 APPLIED LIFE SCIENCES↗