Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

FTIR instrumentation to monitor vapors from Shuttle tile waterproofing materials

The Space Shuttle Thermal Protection System (TPS) tiles and blankets are waterproofed using DimethylEthoxySilane (DMEX) in the Orbiter Processing Facilities (OPF). DMES has a Threshold Limit Value (TLV) for exposure of personnel to vapor concentration in air of 0.5 ppm. The OPF high bay cannot be opened for normal work after a waterproofing operation until the DMES concentration is verified by measurement to be below the TLV. On several occasions the high bay has been kept closed for up to 8 hours following waterproofing operations due to high DMES measurements. In addition, the Miran 203 and Miran 1 BX infrared analyzers calibrated at different wavelengths gave different readings under the same conditions. There was reason to believe that some of the high DMES concentration readings were caused by interference form water and ethanol vapors. The Toxic Vapor Detection Laboratory (TVDL) was asked to test the existing DMES instruments and identify the best qualified instrument. In addition the TVDL was requested to develop instrumentation to ensure the OPF high bay could be opened safely as soon as possible after a waterproofing operation. A Fourier Transform Infrared (FTIR) spectrophotometer instrument developed for an earlier project was reprogrammed to measure DMES vapor along with ethanol, water, and several common solvent vapors. The FTIR was then used to perform a series of laboratory and field tests to evaluate the performance of the single wavelength IR instruments in use. The results demonstrated that the single wavelength IR instruments did respond to ethanol and water vapors, more or less depending on the analytical IR wavelength selected. The FTIR was able to separate the responses to DMES, water and ethanol, and give consistent readings for the DMES vapor concentration. The FTIR was then deployed to the OPF to monitor real waterproofing operations. The FTIR was also used to measure the time for DMES to evaporate from TPS tile under a range of humidity conditions in controlled laboratory tests. The combination of laboratory and field tests with the FTIR instrument demonstrated superior sensitivity, ability to reject interference from water and ethanol vapors, ruggedness to be transported from the lab to the OPF and set up without special procedures or degradation of performance. The multiple component vapor analysis algorithm was developed at KSC and incorporates automatic baseline correction and shape fitting of the spectra. The analysis for DMES, TetraMethylDiSiloxane (TMDS), ethanol, methanol, isopropanol, and baseline parameters uses 161 points per sample at 4 cm(exp -1) resolution, and processes an eight scan sample every ten seconds. The standard deviation of the measurements is 0.013 ppm and the upper linear limit is 125 ppm DMES. Based on successful demonstration of capabilities we produced three mobile instrument carts to be used in each OPF to support future waterproofing operations. The design and building of the 'DMES Carts' were accomplished in Fiscal year 1995.

Mattson, C. B.↗

Using XML and Java for Astronomical Instrumentation Control

Traditionally, instrument command and control systems have been highly specialized, consisting mostly of custom code that is difficult to develop, maintain, and extend. Such solutions are initially very costly and are inflexible to subsequent engineering change requests, increasing software maintenance costs. Instrument description is too tightly coupled with details of implementation. NASA Goddard Space Flight Center is developing a general and highly extensible framework that applies to any kind of instrument that can be controlled by a computer. The software architecture combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML), a human readable and machine understandable way to describe structured data. A key aspect of the object-oriented architecture is software that is driven by an instrument description, written using the Instrument Markup Language (IML). ]ML is used to describe graphical user interfaces to control and monitor the instrument, command sets and command formats, data streams, and communication mechanisms. Although the current effort is targeted for the High-resolution Airborne Wideband Camera, a first-light instrument of the Stratospheric Observatory for Infrared Astronomy, the framework is designed to be generic and extensible so that it can be applied to any instrument.

Ames, Troy↗

Using Model-Based Reasoning for Autonomous Instrument Operation - Lessons Learned From IMAGE/LENA

Model-based reasoning has been applied as an autonomous control strategy on the Low Energy Neutral Atom (LENA) instrument currently flying on board the Imager for Magnetosphere-to-Aurora Global Exploration (IMAGE) spacecraft. Explicit models of instrument subsystem responses have been constructed and are used to dynamically adapt the instrument to the spacecraft's environment. These functions are cast as part of a Virtual Principal Investigator (VPI) that autonomously monitors and controls the instrument. In the VPI's current implementation, LENA's command uplink volume has been decreased significantly from its previous volume; typically, no uplinks are required for operations. This work demonstrates that a model-based approach can be used to enhance science instrument effectiveness. The components of LENA are common in space science instrumentation, and lessons learned by modeling this system may be applied to other instruments. Future work involves the extension of these methods to cover more aspects of LENA operation and the generalization to other space science instrumentation.

Johnson, Michael A.↗

Evaluation of Experimental Data from the GAINS Balloon GPS Surface Reflection Instrument

The GPS Surface Reflection Instrument was integrated as an experiment on the GAINS (Global Airocean IN-situ System) 48-hour balloon mission flown in September 2001. The data collected by similar instruments in the past has been used to measure sea state from which ocean surface winds can be accurately estimated. The GPS signal has also been shown to be reflected from wetland areas and even from subsurface moisture. The current version of the instrument has been redesigned to be more compact, use less power, and withstand a greater variation in environmental conditions than previous versions. This instrument has also incorporated a new data collection mode to track 5 direct satellites (providing a continuous navigation solution) and multiplex the remaining 7 channels to track the reflected signal of the satellite tracked in channel 0. The new software mode has been shown to increase the signal to noise ratio of the collected data and enhance the science return of the instrument. During the 48-hour flight over the Northwest US, the instrument will measure surface reflections that can be detected over the balloon's ground track. Since ground surface elevations in this area vary widely from the WGS-84 ellipsoid altitude, the instrument software has been modified to incorporate a surface altitude correction based on USGS 30-minute Digital Elevation Models. Information presented will include facts about instrument design goals, data collection methodologies and algorithms, and results of the science data analyses for the 48-hour mission.

Gance, George G.↗

Evaluation of Experimental Data from the Gains Balloon GPS Surface Reflection Instrument

The GPS Surface Reflection Instrument was integrated as an experiment on the GAINS (Global Airocean IN-situ System) 48-hour balloon mission flown in June 2002. The data collected by similar instruments in the past has been used to measure sea state from which ocean surface winds can be accurately estimated. The GPS signal has also been shown to be reflected from wetland areas and even from subsurface moisture. The current version of the instrument has been redesigned to be more compact, use less power, and withstand a greater variation in environmental conditions than previous versions. This instrument has also incorporated a new data collection mode to track 5 direct satellites (providing a continuous navigation solution) and multiplex the remaining 7 channels to track the reflected signal of the satellite tracked in channel 0. The new software mode has been shown to increase the signal to noise ratio of the collected data and enhance the science return of the instrument. During the GAINS balloon flight over the Northwest US, the instrument measured surface reflections as they were detected over the balloon's ground track. Since ground surface elevations in this area vary widely from the WGS-84 ellipsoid altitude, the instrument software has been modified to incorporate a surface altitude correction based on USGS 30-minute Digital Elevation Models. Information presented will include facts about instrument design goals, data collection methodologies and algorithms, and will focus on results of the science data analyses for the mission.

Ganoe, George G.↗

Instrument Drift Uncertainties and the Long-Term TOMS/SBUV Total Ozone Record

Long-term climate records from satellites are often constructed from the measurements of a sequence of instruments launched at different times. Each of these instruments is calibrated prior to launch. After launch they are subjected to potential offsets and slow drifts in calibration. We illustrate these issues in the construction of a merged total ozone record from two TOMS and three SBUV instruments. This record extends from late 1978 through the present. The question is "How good are these records?". We have examined the uncertainty in determining the relative calibration of two instruments during an overlap period in their measurements. When comparing a TOMS instrument, such as that on Nimbus 7, with an SBUV instrument, also on Nimbus 7, we find systematic differences and random differences. We have combined these findings with estimates of individual instrument drift into a monte- carlo uncertainty propagation model. We estimate an instrument drift uncertainty of a little larger than 1 percent per decade over the 25-year history of the TOMS/SBUV measurements. We make an independent estimate of the drift uncertainty in the ground-based network of total ozone measurements and find it to be of similar, but slightly smaller magnitude. The implications of these uncertainties for trend and recovery determination will be discussed.

Solarski, Richard S.↗

Issues in Shuttle System Instrumentation

The purose: a) Customer's perspective on Space Shuttle Return to Flight instrumentation; b) Focus on the difficult instrumentation issues; and c) Enable a discussion of new technologies (i.e.- NANO/MEMS/Small Tech) that could enhance Shuttle instrumentation posture. The T-10 Umbilical allows the vehicle instruments to be monitored and recorded prior to each launch and retract during launch.Launch Complex Instrumentation are instruments needed for assessment of Launch Commit Criteria (LCC) Salt-air and launch environments are issues. Instrumentation (Drag-On Instrumentation) can be added as needed to the vehicle for non-flight use. The current Roll-out Fatigue Testing is a primary example.

James, George↗

Pointing compensation system for spacecraft instruments

A closed loop system reduces pointing errors in one or more spacecraft instruments. Associated with each instrument is a electronics package (3) for commanding motion in that instrument and a pointing control system (5) for imparting motion in that instrument in response to a command (4) from the commanding package (3). Spacecraft motion compensation logic (25) compensates for instrument pointing errors caused by instrument-motion-induced spacecraft motion. Any finite number of instruments can be so compensated, by providing each pointing control system (5) and each commanding package (3), for the instruments desired to be compensated, with a link to the spacecraft motion compensation logic (25). The spacecraft motion compensation logic (25) is an electronic manifestation of the algebraic negative of a model of the dynamics of motion of the spacecraft. An example of a suitable model, and computer-simulated results, are presented.

Plescia, Carl T.↗

The Hurricane Imaging Radiometer (HIRAD): Instrument Status and Performance Predictions

The Hurricane Imaging Radiometer (HIRAD) is an innovative radiometer which offers new and unique remotely sensed observations of both extreme oceanic wind events and strong precipitation. It is based on the airborne Stepped Frequency Microwave Radiometer (SFMR) [Uhlhorn and Black, 2004]. The HIRAD instrument advances beyond the current nadir viewing SFMR to an equivalent wide-swath SFMR imager using passive microwave synthetic thinned aperture radiometer (STAR) technology [Ruf et al., 1988]. This sensor operates over 4-7 GHz, where the required tropical cyclone remote sensing physics has been validated by both SFMR and WindSat radiometer [Bettenhausen et al., 2006; Brown et al., 2006]. HIRAD incorporates a new and unique array antenna design along with several technologies successfully demonstrated by the Lightweight Rain Radiometer instrument [Ruf et al., 2002; Ruf and Principe, 2003]. HIRAD will be a compact, lightweight, low-power instrument with no moving parts that will produce wide-swath imagery of ocean winds and rain in hurricane conditions. Accurate observations of surface ocean vector winds (OVW) with high spatial and temporal resolution are required for understanding and predicting tropical cyclones. The Hurricane Imaging Radiometer (HIRAD) is an innovative architecture which offers new and unique remotely sensed observations of both extreme oceanic wind events and strong precipitation. It is based on the airborne Stepped Frequency Microwave Radiometer (SFMR), which is a proven remote sensing technique for observing tropical cyclone (TC) ocean surface wind speeds and rain rates. The proposed HIRAD instrument advances beyond the current nadir viewing SFMR to an equivalent wide-swath SFMR imager using passive microwave synthetic thinned aperture radiometer (STAR) technology combined with a a unique array antenna design. The overarching design concept of HIRAD is to combine the multi-frequency C-band observing strategy of the SFMR with STAR technology to produce a wide-swath imager. Single frequency STAR technology The Hurricane Imaging Radiometer (HIRAD) is an innovative radiometer which offers new and unique remotely sensed observations of both extreme oceanic wind events and strong precipitation. It is based on the airborne Stepped Frequency Microwave Radiometer (SFMR) [Uhlhorn and Black, 2004]. The HIRAD instrument advances beyond the current nadir viewing SFMR to an equivalent wide-swath SFMR imager using passive microwave synthetic thinned aperture radiometer (STAR) technology [Ruf et al., 1988]. This sensor operates over 4-7 GHz, where the required tropical cyclone remote sensing physics has been validated by both SFMR and WindSat radiometer [Bettenhausen et al., 2006; Brown et al., 2006]. HIRAD incorporates a new and unique array antenna design along with several technologies successfully demonstrated by the Lightweight Rain Radiometer instrument [Ruf et al., 2002; Ruf and Principe, 2003]. HIRAD will be a compact, lightweight, low-power instrument with no moving parts that will produce wide-swath imagery of ocean winds and rain in hurricane conditions. Accurate observations of surface ocean vector winds (OVW) with high spatial and temporal resolution are required for understanding and predicting tropical cyclones. The Hurricane Imaging Radiometer (HIRAD) is an innovative architecture which offers new and unique remotely sensed observations of both extreme oceanic wind events and strong precipitation. It is based on the airborne Stepped Frequency Microwave Radiometer (SFMR), which is a proven remote sensing technique for observing tropical cyclone (TC) ocean surface wind speeds and rain rates. The proposed HIRAD instrument advances beyond the current nadir viewing SFMR to an equivalent wide-swath SFMR imager using passive microwave synthetic thinned aperture radiometer (STAR) technology combined with a a unique array antenna design. The overarching design concept of HIRAD is to combine the multi-frequency C-banbserving strategy of the SFMR with STAR technology to produce a wide-swath imager. Single frequency STAR technology

Ruf, Christopher↗

SOFIA Science Instruments: Commissioning, Upgrades and Future Opportunities

The Stratospheric Observatory for Infrared Astronomy (SOFIA) is the world's largest airborne observatory, featuring a 2.5 meter telescope housed in the aft section of a Boeing 747sp aircraft. SOFIA's current instrument suite includes: FORCAST (Faint Object InfraRed CAmera for the SOFIA Telescope), a 5-40 μm dual band imager/grism spectrometer developed at Cornell University; HIPO (High-speed Imaging Photometer for Occultations), a 0.3-1.1 micron imager built by Lowell Observatory; FLITECAM (First Light Infrared Test Experiment CAMera), a 1-5 micron wide-field imager/grism spectrometer developed at UCLA; FIFI-LS (Far-Infrared Field-Imaging Line Spectrometer), a 42-210 micron IFU grating spectrograph completed by University Stuttgart; and EXES (Echelon-Cross- Echelle Spectrograph), a 5-28 micron high-resolution spectrometer being completed by UC Davis and NASA Ames. A second generation instrument, HAWC+ (Highresolution Airborne Wideband Camera), is a 50-240 micron imager being upgraded at JPL to add polarimetry and new detectors developed at GSFC. SOFIA will continually update its instrument suite with new instrumentation, technology demonstration experiments and upgrades to the existing instrument suite. This paper details instrument capabilities and status as well as plans for future instrumentation, including the call for proposals for 3rd generation SOFIA science instruments.

FLITECAM↗

Inter-Calibration and Concatenation of Climate Quality Infrared Cloudy Radiances from Multiple Instruments

A change in climate is not likely captured from any single instrument, since no single instrument can span decades of time. Therefore, to detect signals of global climate change, observations from many instruments on different platforms have to be concatenated. This requires careful and detailed consideration of instrumental differences such as footprint size, diurnal cycle of observations, and relative biases in the spectral brightness temperatures. Furthermore, a common basic assumption is that the data quality is independent of the observed scene and therefore can be determined using clear scene data. However, as will be demonstrated, this is not necessarily a valid assumption as the globe is mostly cloudy. In this study we highlight challenges in inter-calibration and concatenation of infrared radiances from multiple instruments by focusing on the analysis of deep convective or anvil clouds. TRMM/VIRS is potentially useful instrument to make correction for observational differences in the local time and foot print sizes, and thus could be applied retroactively to vintage instruments such as AIRS, IASI, IRIS, AVHRR, and HIRS. As the first step, in this study, we investigate and discuss to what extent AIRS and VIRS agree in capturing deep cloudy radiances at the same local time. The analysis also includes comparisons with one year observations from CrIS. It was found that the instruments show calibration differences of about 1K under deep cloudy scenes that can vary as a function of land type and local time of observation. The sensitivity of footprint size, view angle, and spectral band-pass differences cannot fully explain the observed differences. The observed discrepancies can be considered as a measure of the magnitude of issues which will arise in the comparison of legacy data with current data.

cloudy radiance↗

New Methods for Retrieval of Chlorophyll Red Fluorescence from Hyperspectral Satellite Instruments: Simulations and Application to GOME-2 and SCIAMACHY

Global satellite measurements of solar-induced fluorescence (SIF) from chlorophyll over land and ocean have proven useful for a number of different applications related to physiology, phenology, and productivity of plants and phytoplankton. Terrestrial chlorophyll fluorescence is emitted throughout the red and far-red spectrum, producing two broad peaks near 683 and 736nm. From ocean surfaces, phytoplankton fluorescence emissions are entirely from the red region (683nm peak). Studies using satellite-derived SIF over land have focused almost exclusively on measurements in the far red (wavelengths greater than 712nm), since those are the most easily obtained with existing instrumentation. Here, we examine new ways to use existing hyperspectral satellite data sets to retrieve red SIF (wavelengths less than 712nm) over both land and ocean. Red SIF is thought to provide complementary information to that from the far red for terrestrial vegetation. The satellite instruments that we use were designed to make atmospheric trace-gas measurements and are therefore not optimal for observing SIF; they have coarse spatial resolution and only moderate spectral resolution (0.5nm). Nevertheless, these instruments, the Global Ozone Monitoring Instrument 2 (GOME-2) and the SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY (SCIAMACHY), offer a unique opportunity to compare red and far-red terrestrial SIF at regional spatial scales. Terrestrial SIF has been estimated with ground-, aircraft-, or satellite-based instruments by measuring the filling-in of atmospheric andor solar absorption spectral features by SIF. Our approach makes use of the oxygen (O2) gamma band that is not affected by SIF. The SIF-free O2 gamma band helps to estimate absorption within the spectrally variable O2 B band, which is filled in by red SIF. SIF also fills in the spectrally stable solar Fraunhofer lines (SFLs) at wavelengths both inside and just outside the O2 B band, which further helps to estimate red SIF emission. Our approach is then an extension of previous approaches applied to satellite data that utilized only the filling-in of SFLs by red SIF. We conducted retrievals of red SIF using an extensive database of simulated radiances covering a wide range of conditions. Our new algorithm produces good agreement between the simulated truth and retrievals and shows the potential of the O2 bands for noise reduction in red SIF retrievals as compared with approaches that rely solely on SFL filling. Biases seen with existing satellite data, most likely due to instrumental artifacts that vary in time, space, and with instrument, must be addressed in order to obtain reasonable results. Our 8-year record of red SIF observations over land with the GOME-2 allows for the first time reliable global mapping of monthly anomalies. These anomalies are shown to have similar spatiotemporal structure as those in the far red, particularly for drought-prone regions. There is a somewhat larger percentage response in the red as compared with the far red for these areas that are drought sensitive. We also demonstrate that good-quality ocean fluorescence line height retrievals can be achieved with GOME-2, SCIAMACHY, and similar instruments by utilizing the full complement of radiance measurements that span the red SIF emission feature.

spatiotemporal structure↗

Prelaunch and On-Orbit Electronic Calibration for Earth Observing Instruments

"The Electronic Calibration (Ecal) tests are performed during various stages of instrument development to examinethe linearity of the instrument electronics. During this process, charges with stepwise increments are injected inthe analog electronics circuitry to generate a ramp signal that can be used to characterize any nonlinearities in theelectronics. The prelaunch characterization of MODIS (on the Terra and Aqua platforms) and VIIRS (on SNPP,JPSS-1 and JPSS-2) involved a regular evaluation of the electronics linearity using the Ecal tests. On orbit,the Ecal tests have been regularly performed over the mission for both the MODIS instruments to derive theelectronics gain and linearity. Unlike MODIS, the Ecal tests on the VIIRS instruments are performed on an as-needed basis. To date, no Ecal tests were performed for S-NPP VIIRS on orbit. The VIIRS instrument on JPSS-1(now NOAA 20) was launched on November 18, 2017. An Ecal test was performed to support the instrumentsinitial post-launch performance assessment. Shortly after the first on-orbit emissive band calibration, degradationin the instrument gain was observed for the LWIR bands (M15, M16 and I5). As a part of the investigationrelated to this anomaly, a second Ecal test was performed and results were compared with the prelaunch results.In this paper, we discuss the prelaunch Ecal tests and representative results from MODIS and VIIRS prelaunchcharacterization. Also, discussed are the on-orbit results from the two MODIS instruments as well as from therecently launched VIIRS instrument."

ECAL↗

Cross‐Instrument Comparison of MapCam and OVIRS on OSIRIS‐REx

Two of the instruments onboard the OSIRIS-REx spacecraft, the MapCam color imager and the OVIRS visible and 20 infrared spectrometer, observed the surface of asteroid (101955) Bennu in partially overlapping wavelengths. 21 Significant scientific advances have been enabled by using data from these two instruments in tandem, but a robust 22 statistical understanding of their relationship is needed for future analyses to cross-compare their data as accurately 23 and sensitively as possible. Here we present a cross-instrument comparison of data acquired by MapCam and 24 OVIRS, including methods and results for all global and site-specific observation campaigns in which both 25 instruments were active. In our analysis, we consider both the absolute radiometric offset and the relative 26 (normalized) variation between the two instruments; we find that both depend strongly on the photometric and 27 instrumental conditions during the observation. The two instruments have a large absolute offset (>15%) due to their 28 independent radiometric calibrations. However, they are very consistent (relative offset as low as 1%) when each 29 instrument’s response is normalized at a single wavelength, particularly at low phase angles where shadows on 30 Bennu’s rough surface are minimized. We recommend using the global datasets acquired at 12:30 pm local solar 31 time for cross-comparisons; data acquired at higher phase angles have larger uncertainties.

D R Golish↗

Production of Flight Instruments for Multi-Satellite Constellations

Recent National Academy of Science Decadal Surveys in space and Earth-science have called for simultaneous, distributed multi-point measurements in and from space, requiring constellations of small spacecraft. Small satellites have demonstrated their utility for enabling high-quality science measurements and observations. NASA missions have leveraged advances in sensor miniaturization, technology innovations, and new small satellite mission architectures to enable meaningful measurement-based scientific investigations that operate on small satellites and that are responsive to science objectives described in National Academy of Science Decadal Surveys. The advent of high capability small spacecraft enables consideration of science missions involving multiple small spacecraft, constellations of a few or many for simultaneous distributed in situ observations or remote observations from a variety of viewpoints. The central challenge for fielding instrumented space-flight constellations is to provide the required multiple sets of fully verified and calibrated instrument hardware, software, and operational processes from within a one-off project-based scientific space flight culture. Although there are numerous commercial entities providing “off-the shelf” spacecraft and avionics, the challenge lies in the multi-unit production of the uniquely targeted instrumentation necessary to perform the specific measurements required for a particular science investigation. Traditionally, the cost of such instrumentation has represented a significant portion of the hardware cost for a mission and posed the highest risk area for implementation. A shift in paradigm from large science platforms to constellations of smaller satellites drives the challenge to build instruments in a quasi-production environment. This paper describes key aspects of, and challenges encountered in the development program for the successful production of instruments for the Fast-Plasma Investigation (FPI) instrument suite of 64 flight plasma spectrometers and supporting electronics on the NASA Magnetospheric Multiscale (MMS) 4 satellite constellation mission. Although the MMS mission was not composed of small satellites, there are key aspects of the instrument production that apply directly to constellations of small satellites.

Arthur D Jacques↗

Production of Flight Instruments for Multi-Satellite Constellations

Recent National Academy of Science Decadal Surveys in space and Earth-science have called for simultaneous, distributed multi-point measurements in and from space, requiring constellations of small spacecraft. Small satellites have demonstrated their utility for enabling high-quality science measurements and observations. NASA missions have leveraged advances in sensor miniaturization, technology innovations, and new small satellite mission architectures to enable meaningful measurement-based scientific investigations that operate on small satellites and that are responsive to science objectives described in National Academy of Science Decadal Surveys. The advent of high capability small spacecraft enables consideration of science missions involving multiple small spacecraft, constellations of a few or many for simultaneous distributed in situ observations or remote observations from a variety of viewpoints. The central challenge for fielding instrumented space-flight constellations is to provide the required multiple sets of fully verified and calibrated instrument hardware, software, and operational processes from within a one-off project-based scientific space flight culture. Although there are numerous commercial entities providing “off-the shelf” spacecraft and avionics, the challenge lies in the multi-unit production of the uniquely targeted instrumentation necessary to perform the specific measurements required for a particular science investigation. Traditionally, the cost of such instrumentation has represented a significant portion of the hardware cost for a mission and posed the highest risk area for implementation. A shift in paradigm from large science platforms to constellations of smaller satellites drives the challenge to build instruments in a quasi-production environment. This paper describes key aspects of, and challenges encountered in the development program for the successful production of instruments for the Fast-Plasma Investigation (FPI) instrument suite of 64 flight plasma spectrometers and supporting electronics on the NASA Magnetospheric Multiscale (MMS) 4 satellite constellation mission. Although the MMS mission was not composed of small satellites, there are key aspects of the instrument production that apply directly to constellations of small satellites.

Arthur D Jacques↗

Proceedings of the 25th International Instrumentation Symposium, May 7-10, 1979, Anaheim, California

The papers deal essentially with the instrumentation needs of the transportation industry, machinery diagnostics, and energy research. The sessions covered include: acoustic emission, reentry vehicle ground and flight testing, performance of nose tip materials, instrumentation for solar heating and cooling systems, vibration measurement, data acquisition and analysis, system for aerospace pressure measurements, wind tunnel instrumentation and control, energy source instrumentation, nondestructive testing, pressure and flow measurements, automated test facilities, strain measurements, electrooptical instrumentation, thermal measurements, microcomputer applications in instrumentation and automation, flight testing, blast pressure measurement, two-phase liquid/gas mass flow measurement, and machinery monitoring and instrumentation.

Conferences↗

Ambient Optomechanical Alignment and Pupil Metrology for the Flight Instruments Aboard the James Webb Space Telescope

The James Webb Space Telescope science instruments are in the final stages of being integrated into the Integrated Science Instrument Module (ISIM) element. Each instrument is tied into a common coordinate system through mechanical references that are used for optical alignment and metrology within ISIM after element-level assembly. In addition, a set of ground support equipment (GSE) consisting of large, precisely calibrated, ambient, and cryogenic structures are used as alignment references and gauges during various phases of integration and test (I&T). This GSE, the flight instruments, and ISIM structure feature different types of complimentary metrology targeting. These GSE targets are used to establish and track six degrees of freedom instrument alignment during I&T in the vehicle coordinate system (VCS). This paper describes the optomechanical metrology conducted during science instrument integration and alignment in the Spacecraft Systems Development and Integration Facility (SSDIF) cleanroom at NASA Goddard Space Flight Center (GSFC). The measurement of each instrument's ambient entrance pupil location in the telescope coordinate system is discussed. The construction of the database of target locations and the development of metrology uncertainties is also discussed.

Optomechanical Alignment↗