At least 127 records · Page 7

Technical Performance of Refractory Liners for Molten Chloride Salt Thermal Energy Storage Systems

A chloride-based molten-salt system that uses a ternary blend of MgCl2/KCl/NaCl is investigated to provide higher temperature thermal energy storage capability. Despite higher thermal stability, molten chlorides present several unique challenges, including the design of internal refractory-ceramic liners to prevent the corrosion and thermal stress of alloy tank shells. This work discusses issues and potential solutions related to containment of molten chloride salt, specifically the optimization of the refractory material at the molten salt interface (hot face). The down-selected hot face candidate limits permeation of salt through the material and forms a highly stable secondary surface phase in equilibrium with the molten salt. A mortar is created using the corrosion resistant hot face brick. Brick and mortar composite are subjected to mechanical stress/strain analysis, in order to calculate composite material properties and better inform thermomechanical models. The U.S. Department of Energy Generation 3 (DOE Gen3) program seeks to develop higher efficiency CSP plants that can provide cost-competitive, flexible power in the U.S. electric grid. The proposed Gen3 Liquid Pathway CSP plant closely resembles the configuration of current nitrate salt power towers with two-tank storage (Gen2). The differences between Gen2 and Gen3 include the types of compatible materials used in salt storage tank construction. Stainless steel loses strength at Gen3 temperatures, and although nickel superalloys would be capable of withstanding sustained high temperatures, these materials are prohibitively expensive at scale. Uninsulated tank shells also pose a significant risk as common steels are highly susceptible to chemical attack from molten chloride salt. To address these concerns, refractory-ceramic based containment materials are proposed to line the inside of the hot and cold storage tanks. In doing so, stainless or carbon steel shells may be used in construction depending on the level of insulation provided. The composition of the internal liner requires careful consideration to maximize the efficacy of multiple parameters including corrosion resistance, strength at operating temperature, durability, and cost. This is particularly true for the material at the interface with the salt, known as the "hot face", which is responsible for protecting the insulating layers between the tank shell and the hot face brick layer. The molten salt in this system is superheated over 300 °C above its freeze temperature. Therefore, unlike other industrial processes which use refractory-lined vessels, it is not expected that a freeze plane will develop in the hot face. Therefore, the hot face must be designed to withstand chemical corrosion and inhibit permeation of molten salt into the insulating layers. A down selection was performed to identify a hot face candidate best equipped to maintain thermal, mechanical, and chemical integrity when exposed to molten salt over extended periods of time. Long-duration chemical capability experiments were conducted with the down selected hot face refractory fully immersed in molten chloride salt for up to 3000 hours. The average salt penetration does not exceed 100 microns. When extrapolated to 20 and 30 years of continuous exposure, the expected salt penetration depth is approximately 2.0 mm and 2.9 mm, respectively. A magnesium-rich secondary phases develops at the salt/refractory interface. X-ray diffraction identifies the material as forsterite (Mg2SiO4), which is reported to form synthetically in molten chloride salt solutions. These results suggest the selected hot face will adequately inhibit salt permeation. While there is optimism that the hot face brick will inhibit salt permeation, mortar joints are typically the weakest point of a refractory brick liner. From a thermochemical perspective, differing thermal expansion coefficients may result in the mortar and brick to grow independent of each other, creating gaps through which molten salt can penetrate. To address this issue, NREL has developed an in-house mortar composed of the down selected hot face brick that has been shown to be compatible with the salt. Compressive stress/strain analyses have been performed on the brick/ mortar composites to generate stress/strain curves. Modulus of elasticity and Poisson's ratio of the composite may be calculated from the stress/strain curves, in order to provide more representative data to finite element mechanical models for accurate approximation of stress on the tank shell and the amount of thermal expansion expected within the tank liner.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Bay Area Regional Energy: Network Integrated Commercial Retrofits (BRICR) Project. Final Report

The BRICR project applied large-scale building energy modeling concepts with the aim of reducing the cost of energy efficiency targeting, design, and project development, and measurement of energy savings for energy efficiency programs implemented by local governments that serve small and medium commercial buildings (SMB). The project leveraged the services and resources of existing local government energy programs serving disadvantaged and hard-to-reach SMB customers. In contrast to programs run by utilities, local government programs generally do not have direct access to energy billing records for an entire class of customers in a geographic area, which prior research demonstrated useful for large-scale building energy model baseline development and calibration. , However, local governments are rich in public records that offer important clues about physical attributes and uses that, along with behavior, determine energy use. Relying only on public records, BRICR demonstrated development of credible baseline energy models for 3,792 office, retail, and hotel buildings. Publicly disclosed annual energy use data from a local energy benchmarking program and anonymized data from the Building Performance Database, the nation’s largest dataset about energy-related characteristics of buildings, were utilized to validate and calibrate energy models via an innovative method comparing distributions of energy intensity by fuel type for portfolios of buildings of similar size, vintage, and use. Portfolio calibration does not provide certainty that an energy model fits an individual building; the method is useful when billing data is not accessible – a common situation for researchers, energy service providers and ESCOs, local governments, and any party other than a utility. A software component was developed, the BRICR gem, which automates simulation when relevant data is added or edited by the user to a file saved in the standardized BuildingSync XML schema for energy audit data. The component was demonstrated as a simplified means to generate a mass of energy models corresponding to public records containing basic attributes such as building scale, location, use, year built, and aspect ratio in combination with building energy code prototype data corresponding to use and vintage. The component was also demonstrated as a simplified means to automate energy simulation when attributes are revised; the intention was to enable iterative improvement of the baseline model and energy savings estimates for common energy conservation measures as users revise relevant attributes based on their observations. In the context of institutional change and uncertainty for the participating local government energy programs, 13 whole building retrofits were completed. Impacts were measured by applying the CalTRACK2.0 methods to standardize measurement of normalized metered energy consumption. The GRIDMeter methods of stratified sampling and individual load shape analysis were applied to adjust for impacts of the effect of COVID-19 on retrofitted buildings in the context of all local buildings of similar size and use. Excluding impacts of the pandemic, retrofitted buildings demonstrated between 1.6% and 25.1% reduction in energy use. The project contributed use cases and feedback that helped inform evolution of the software tools and data formats that were combined for the first time in the BRICR project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Using the Carbon Capture Simulation Initiative (CCSI) Tool to Design the Experiments in the Parametric Campaign of a Novel Compact Absorber for Carbon Capture

Gas absorption towers with structured packing and solvent have been used for Carbon Dioxide (CO 2 ) Capture for about many decades. To overcome process limitations and practical disadvantages for CO 2 capture from the stationary emitter (e.g. NG and coal power plant), many new designs have been proposed and explored at the various scales in the last decade with aim of either low energy penalty or low capital cost. To reduce the size of the absorption tower and hence the total cost of CO 2 capture, the University of Kentucky Center for Applied Energy Research Center (UK CAER) has designed and built a novel CO 2 capture absorption tower or Compact Absorber, integrated into an existing large-bench scale CO 2 capture unit. The Compact Absorber has three sections. The top of the column is a fogging section where the solvent is sprayed through a nozzle producing droplets flowing downward in a co-current fashion with the flue gas. The center of the column is a frothing section where the solvent and flue gas flow through regenerative frothing screens designed by Industrial Climate Solutions, Inc. The bottom of the column is a typical structured packing section were the flue gas and solvent flow in a counter-current fashion. The parametric campaign will be conducted in order to optimize the operating parameters for CO 2 capture including liquid/gas ratio, lean loading, and temperature, liquid residence time. A simulated flue gas with 14% CO 2 will be used along with a UK CAER developed proprietary solvent. The 100-hour parametric campaign is designed using a statistical approach of the Sequential Design of Experiments (sDOE). sDOE is one of the CCSI tools that provides an adaptive statistical approach for designing future experiments based on the results of previous experiments. Application of a typical DOE provides the user with the minimum number of experiments required to get the same data, but sDOE allows the user to make an informed choice of experiments based on the results of previous experiments. The complete absorption column has been constructed and has been partially commissioned. Initial data has been collected by operating using the fogging section and the frothing section. The fogging section produces solvent droplets of about 100 μm sauter mean diameter and as small as 25 μm using a hydraulic nozzle by BETE. The frothing section produces bubbles of about 5mm with high mixing of solvent promoting the higher mass transfer from gas to liquid. The absorber reaches the capture efficiency of about 50% with only two sections in operation. Based on the current results, it can be deduced that increasing the solvent feed temperature and including the packed section for absorption the capture efficiency will increase further. Initial data will be collected using all three sections of the absorber and will be used for sDOE. Non-Uniform Space Filling model of sDOE will be used to prioritize the input conditions resulting into maximum capture efficiency. sDOE is performed using the platform called Framework Optimization, Quantification of Uncertainty, and Surrogates (FOQUS). The method and results demonstrating the progress of the parametric campaign from the initial set of experiments to the final stage of obtaining optimized parameters using sDOE tool will be presented in detail.

20 FOSSIL-FUELED POWER PLANTS↗

Assessment of Bulk Oxygen Capacity and Transient Redox Behavior of Foamed Lanthanum Strontium Manganese Perovskites

Synthesis of solar thermochemical hydrogen (STCH) production redox materials with engineered structures, for example, replica foams, can enable efficient heat and mass transport and are critical for scaled-up systems. Prior work has motivated the use of lanthanum strontium manganese (LSM)-type perovskites as foamed STCH materials, but the effect of their morphology on bulk and kinetic behavior has not been reported. In this work, replica and direct foamed samples of La 0.65 Sr 0.35 MnO 3-δ (LSM35) were fabricated and compared to synthesized powders and dense monoliths, and similarly synthesized CeO 2-δ (ceria) foams, regarding their specific reaction rates and bulk oxygen capacity/H 2 yields. Changes in oxygen capacity (Δδ) and reaction rates were measured between 1200 °C and 1400 °C by using fixed ratios of steam and hydrogen during both reduction and oxidation steps, allowing for analysis under practical high conversion conditions. Results suggest bulk behavior and reaction rates of the foamed LSM materials are comparable to their powder analogues. Differences in reaction rates were observed only when replica foamed samples were subjected to rapid laser heating (emulating conditions expected in solar furnaces), which is expected but has not been demonstrated at such a small scale. Here, foamed samples were further subjected to 50 redox cycles at 1400 °C to evaluate their stability. Results show no statistically significant decrease in hydrogen production for any of the foamed samples, but the direct foamed samples became brittle with time. Together, these results demonstrate the viability of replica foamed LSM perovskites for integration in scaled-up STCH systems.

08 HYDROGEN↗

Suppressing CO formation in low-temperature methanol steam reforming via Ce-modified CuZnGa layered oxide catalysts

Cu-based layered double hydroxides (LDHs) are widely recognized as effective catalysts for low-temperature methanol steam reforming, yet achieving high hydrogen productivity together with near-complete suppression of CO formation remains challenging. Here, we report the synthesis and evaluation of a series of CuZnGa LDH-derived catalysts and Ce-modified analogues prepared via an aqueous miscible organic method, which enables high metal dispersion and precise structural control. The optimized CuZnGa catalyst exhibits a hydrogen production rate of 16.9 µmol H 2 ·g cat −1 ·s −1 at 180 °C with an H 2 /CO ratio exceeding 3500, outperforming many state-of-the-art low-temperature systems. Importantly, the incorporation of small amounts of Ce further suppresses CO formation while maintaining high hydrogen productivity. Combined spectroscopic characterization and density functional theory calculations reveal that Ce is incorporated into the LDH lattice by substituting Ga 3+ sites up to a critical threshold, beyond which highly dispersed CeO x species are formed. These species provide mobile lattice oxygen that participates in a Mars-van Krevelen-type pathway, selectively oxidizing CO and suppressing the reverse water-gas shift reaction. This study establishes a clear relationship between Ce speciation, oxygen mobility, and catalytic selectivity in LDH-derived systems. The resulting catalysts demonstrate the potential of interface-engineered Cu-based materials for efficient low-temperature hydrogen production with minimal CO contamination.

09 BIOMASS FUELS↗

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems

Neutron multiplicity counting (NMC) is a technique for the assay of fissile material. In this work, three detection systems are utilized for active interrogation assay of shells of the Rocky Flats shells (highly enriched uranium, 93% 235U) stacked from 13.25-54.92 kg assemblies. The singles ($R_1$) and doubles ($R_2$) rates are calculated with each system to estimate two sample parameters: $M_L$- the leakage multiplication and F - the sample fission rate. The estimated mass, m, is found by dividing F by a constant activity per unit mass. Since we are interrogating HEU, the α ratio of (α; n) to fission neutrons is taken to be zero. The system of equations to calculate these quantities was originally derived. The Neutron Multiplicity 3 He Array Detector (NOMAD) consists of 15 3 He tubes inside polyethylene and is the traditional, capture-based detection system for NMC. The polyethylene moderates incoming neutrons for thermal capture in individual tubes. The low gamma background, discrete capture signals, and high efficiency of the NOMAD are beneficial for NMC. However, the time to slow down neutrons to thermal energies leads to a system die away time on the scale of microseconds. Comparatively, the Rossi-alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAMRODD) and the Organic Scintillator Array (OSCAR) are scatter-based detection systems. RAMRODD consists of 8, 5.08 by 5.08 cm EJ-309 liquid scintillators in 4 pairs, evenly-spaced with 90 degrees separation about the center of each assembly. OSCAR consists of a single array of 12, 5.08 by 5.08 cm trans-stilbene crystals aligned with the center of the assembly. Scatter-based systems detect fast neutrons without any moderation, leading to system die away times on the scale of tens of nanoseconds. This allows much shorter timing gate widths compared to thermal systems, thus increasing counting statistics of true correlated fission events. However, scatter-based systems are susceptible to neutron cross-talk when an incident neutron scatters off one detector and interacts in an adjacent detector, causing two seemingly correlated detection signals. The equations developed adjust for cross-talk to conduct NMC with scatter-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robust Combined Heat and Hybrid Power (CHHP) for High Electrical Efficiency Cogeneration

Georgia Tech (Prime Recipient), the University of Texas at El Paso (UTEP) and the National Energy Technology Laboratory (NETL) investigated a hybrid fuel cell/ gas turbine system concept as a combined heat and hybrid power (CHHP) system for both robust and high power-to-process heat ratio cogeneration. The novelty of the proposed system entailed the distinct, elevated electrical efficiencies it maintains while simultaneously supporting a broad span of heating needs (e.g., supply temperatures) demanded across variable heat loads. The scope included: 1) leveraging a pioneering national lab facility configured for dynamic system operability development of hybrid fuel cell/gas turbine cycles; 2) enabling technology development to adjust and modulate the quality and quantity of thermal supply to bottoming heat loads via novel extreme temperature gas bypass valves. Hybrid fuel cell/gas turbine systems have primarily been reduced-to-practice in a constrained (e.g., initial proof-of-concept) manner and have still demonstrated considerable electrical efficiencies. However, these pre-pilot systems have focused upon electrical efficiencies and electrical power generation as the exclusive energy demand. Such hybrid systems had not been extensively researched or developed for flexible and variable operation consisting of both power and heat demands; however, these variable combined power and heat demands are characteristic of many types of manufacturers such as animal/poultry processing, bakeries and milk/flour/pastry manufacturing, textile mills, and electrochemical processing. Commercially, developing the system into a working combined heat and power system benefits these types of manufacturers by allowing them to meet their power and heat demands at a lower cost, higher efficiency, and/or through onsite generation. Therefore, the technical scope of this project was largely to study and facilitate these hybrid systems as combined heat and hybrid power (CHHP) systems that include dynamic operability for variable heat and power loads and/or grid dynamics for various types of manufacturers. Simulation results were used to predict the performance of the CHHP system and conceptually develop it to achieve desired dynamic operability. Experimentally, the primary goal was to design, manufacture, and experiment upon a high-temperature bypass valve. Experimental data included air mass flow rates through the valve orifice when the valve was changed to variable extent between fully closed and fully open. The experimental data was then used to create a semi-empirical computational model of the bypass valve. Concluded simulation goals for the research included developing computational heat exchanger models for the hybrid system inclusive of the bottoming heat exchanger and the recuperative heat exchanger, and then combining the computational recuperator model with the computational valve model. Afterwards, the computational models were then integrated to predict the dynamic operation of hybrid fuel cell/gas turbine cycles throughout a design space and reporting such. The scope stated in the preceding paragraph was packaged into five specific goals: 1) enabling the simulation of dynamic combined heat and power through the creation of computational, modular heat exchanger models; 2) simulation and exploration of the CHHP system’s performance by integrating the heat exchanger models with the national lab’s pre-existing hybrid system (computational) simulation, but without the recuperator bypass valve concept in order to initially determine how the (baseline) system behaves and can be controlled in order to meet variable heat and power demands; 3) development and initial deployment of the high-temperature recuperator bypass valve technology in order to confirm and characterize the approach; 4) usage of the experimental data for the valve to create a semi-empirical computational model for the bypass valve which could then be combined with the heat exchanger computational models; 5) repeat of the second task of simulating and exploring the system’s performance, but this time including the bypass valve to resolve its efficacy. Tasks were successfully completed, and the general notion of flexibly operating, high electrical efficiency CHHP was further corroborated. Supportive details are provided in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity Study for Forecasting Variables of WRF-Solar Using a Tangent Linear Approach

Integrating solar generation in recent years has highlighted the need for improved accuracy in predicting solar power. Confidence in solar power forecasting can be achieved by designing an ensemble that provides reliable probabilistic information for solar radiation with reduced uncertainty and error. Ideally, ensemble members are created through the optimized perturbation of the initial conditions in numerical weather prediction (NWP) models. Tangent linear models are capable of efficiently investigating the sensitivity of solar radiation to model input parameters because they do not require individual perturbation of each variable. This sensitivity study using tangent linear models provide us the capability to identify the right variables to perturb in an ensemble prediction system. In this study, we developed tangent linear models for WRF-Solar modules that directly impact the computation of solar radiation and the simulation of cloud formation and dissipation including the Fast All-sky Model for Solar Applications (FARMS), the Noah land surface model (LSM), the Thompson microphysics, the Mello-Yamada-Nakanishi-Niino (MYNN) boundary layer parameterization, and the Deng scheme for a shallow-convection parameterization. A sensitivity analysis was conducted under various scenarios based on satellite observations and model simulations from the National Solar Radiation Data Base (NSRDB) and WRF-Solar, respectively. Critical forecasting variables that are highly sensitive to the forecasting of global horizontal irradiance (GHI), direct normal irradiance (DNI), cloud mixing ratio, cloud tendency, cloud fraction, and sensible and latent heat fluxes were determined using the relevant WRF-Solar module. This study will be used as a guidance on future research leading to high-quality probabilistic solar forecasting. In this presentation, we discuss the validation of tangent linear approach for WRF-Solar modules and illustrate how the sensitivity results are valuable in the improvement of probabilistic solar prediction.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Demonstration of a High-Pressure Swirl Oxy-Coal Combustor

This technical report presents the exploration of the design and prototyping of a High-Pressure Swirl Oxy-coal Combustor. Pressurized oxy-coal combustion systems have the potential to improve efficiency along with an increased carbon capture rate. Reduction of flue gas at higher pressure, smaller system size, and capital cost reductions render high-pressure oxy-coal systems particularly attractive as next-generation energy-producing systems. High-pressure oxy-coal combustion systems are a recent concept, and thus operability issues of combustor designs for such systems are not fully understood. Significant challenges exist to maintain oxy-coal combustion stability at elevated pressure and a high CO 2 diluent environment. Although a body of knowledge exists for high-pressure oxygen combustion in rocket engines (or similar applications), it is yet to be strategized how these fundamental concepts can be translated to low-temperature CO 2 diluent combustion regimes. The realization of the pressurized oxy-coal based systems requires combustor components to be designed and demonstrated for an operating pressure over 10 bar. However, pressurized oxy-coal combustor design information at this pressure range and scale relevant to validate those proposed systems is currently limited. Experimental data from MWth scale oxy-coal combustors are needed to identify the optimal trade-off between net efficiency and systems size. The proposed effort is aimed at demonstrating a 1 MWth down-fired swirl Oxy-Coal combustor and investigate the interrelation between combustor operating conditions (pressure; flame stability; flue gas recirculation ratio) and conversion efficiencies to minimize oxygen requirements. One of the key challenges is to configure burner design (i.e., swirl number and injector) and operating conditions for high-pressure oxy-coal combustion systems. These experiments differ from current systems partly due to the high theoretical flame temperature and related burner operability issues associated with oxy-combustion. An ASPEN PLUS® model study for 550 MWe TIPS and ENEL pressurized oxy-coal systems with CO 2 recirculation was performed to evaluate system design, subsystems sizing, and operating condition determination. The system analysis effort included TRL and technology gap determination of subsystems and critical components. This information was scaled to develop design requirements (design pressure and flue gas recirculation: RR Flue Gas = $\frac{m_{flue}}{m_{total}}$) for the 1 MWth combustor. The effects of a wide range of carbon dioxide recirculation ratios on the thermal efficiency of ENEL and TIPS cycles are studied. The pressure of 10 bar and 80 bar are used for ENEL and TIPS cycles, respectively. The thermal efficiency of ENEL is significantly higher than the efficiency of TIPS at a pressure of less than 10 bar. The insights from system analysis were then used to design a 1 MWth swirl oxy-coal combustor. Flame temperature analysis and material strength analysis was performed to determine the combustor thickness. The structural integrity of the combustor was validated by finite element analysis using Abacus® and Hypermesh®. Feasibility of igniters and secondary burners are investigated in successful high-pressure oxy-methane combustion. The secondary burners are designed in such a way that it can operate between 100 to 500 kW firing input. Three generations of the pintle injector were designed based on swirl numbers (S=0, 0.9, and 1.2). Key pintle injector parameters such as pintle size, pintle orifice size, spray pattern were investigated by cold flow tests. Information from these tests was used to modify injector design for smooth and successful operation. A 5 mm pintle orifice size was decided upon as the optimum size for oxy-coal operation for the combustor. Shadow sizing experiments were performed to identify the atomization rate of each injector. Different coal water slurry mixtures (30 – 50% coal by wt% in the mixture) at various total momentum ratios (TMR) were investigated for this purpose. These experiments provided decisive information to choose the best design of the injector. The injector with 1.2 swirl provided higher atomization in all cases than other designs. The mean equivalent droplet size of the jet was similar at different TMR and mixture ratios using this injector, thus making it suitable for use in most cases. Therefore, the 1.2 swirl-pintle injector was chosen for the shakedown test. The combustor and other sub-systems, including feed systems and control and data acquisition, have been manufactured, assembled, and integrated. The total system integration and installation began on July 1, 2020. The shake-down tests and initial operational capability demonstration are expected to be completed by September 30, 2020.

01 COAL, LIGNITE, AND PEAT↗

Weatherization Assistant NEAT/MHEA

The software provides a measure selection technique indicating cost effective retrofit activities that can be applied to a home using a standard Savings to Investment Ratio (SIR). Users must provide an input file describing the characteristics of the home to be evaluated. The software takes the input data provided and calculates energy savings and cost savings predicted for a standard set of measures given the input parameters. The Weatherization Assistant computes estimates of pre-retrofit whole building space heating and cooling energy consumptions based on the house description data supplied by the user. The consumptions are computed using a monthly heating and cooling variable base degree-day method by algorithms similar to those developed for the CIRA program [LBL, 1982]. The building consumptions are needed in computing the energy savings from measures affecting the efficiencies of the heating and cooling equipment. Weatherization Assistant then computes the energy savings and costs for each individual measure applicable to the building described as if it were the only measure installed in the house. From these energy savings, a discounted dollar savings over the life of each measure is computed. The ratio of this dollar savings to the cost of installing the measure, the "savings-to-investment ratio" (SIR), is used in an initial ranking of the measures' effectiveness. The "interacted" savings and SIR of measures are then determined assuming the measures are added to the house collectively, in order of their ranking, e.g., the second ranked measure is installed in the house initially described by the user after having been modified by the first ranked measure. If this second-ranked measure's updated SIR is greater than a user-defined limit, the measure is left implemented, else it is removed so that the next measure's effectiveness is not dependent on it. The choice between two mutually exclusive measures (such as different levels of insulation) is made on the basis of their "net present value" (NPV), the difference of life-time savings and installation cost, rather than their SIR. This has been shown to be the more correct criterion on which to base the selection between two measures, both of which cannot be installed. The audit computes and reports to the user the energy savings, discounted dollar savings, installation cost, and SIR for each measure considered cost-effective. For those with SIR greater than the user-designated cutoff, a materials list gives the material name, type, and quantity required for installation of the measure. Weatherization Assistant permits entry of pre-retrofit billing data for gas or electrically heated homes or homes with electric air-conditioning. The user may then make the decision to have the savings of the measures adjusted to reflect the difference in billed consumption and that predicted by the program.

Gettings, Michael↗

Demonstration of gold nanorod systems for enhanced total efficiency: Experimental and numerical analysis

This study investigates the photothermal performance of gold nanorods engineered to exhibit longitudinal plasmon resonances at 695 nm, 780 nm, and 970 nm. The work combines synthesis, structural characterization, extinction measurements, numerical modeling, and controlled temperature experiments to quantify how nanorod geometry, resonance tuning, concentration, and chamber shape jointly influence heat generation. Transmission electron microscopy confirms that increasing nanorod aspect ratio systematically shifts the longitudinal plasmon peak toward the near-infrared region. Extinction measurements show strong agreement with theoretical predictions, validating the numerical model across two independent datasets. Three chamber geometries were tested under laser excitation at 640 nm, 808 nm, and 980 nm: an ascending stepped base, a flat base, and a descending stepped base. Without nanorods, the ascending geometry produced the highest efficiency due to enhanced natural convection. After introducing gold nanorods, all geometries exhibited substantial thermal enhancement, with total efficiencies exceeding 20%. The strongest improvement was obtained for nanorods resonant at 780 nm with a mass concentration of 4.6 mg/mL implemented on the descending stepped-base geometry. This performance resulted from the combined effect of spectral overlapping with the 808 nm laser, the highest nanorod concentration, and localized heat accumulation that intensified buoyancy-driven flow. The findings demonstrate that total efficiency is governed by a synergistic interplay between optical resonance, nanoparticle concentration, and macroscopic chamber design, revealing the system-level coupling between nanoscale plasmonic absorption and macroscale heat-transfer phenomena. The results provide a validated framework for tuning nanoscale plasmonic absorbers and optimizing thermal systems for applications requiring efficient light-to-heat conversion.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Nested Pebble Bed Blanket (NesPeB)

Recent advances in magnetic confinement fusion technology have attracted billions of dollars of investments in startups from venture capitals and corporations, resulting in the development of devices aiming to demonstrate net energy gain in a self-heated burning plasma, such as SPARC (under construction) and others. However, future fusion power plants must operate in regimes that will require technologies far beyond current experience. According to a National Academies of Science, Engineering, and Medicine report, to have nuclear fusion power plants contributing in a timely manner to the planned reduction of atmospheric carbon dioxide, a pilot plant should be built by 2035, and it should demonstrate fusion power production and the performance of the tritium fuel system (requiring a high enough tritium breeding) by 2040. A recognized key technology gap by [26] is the fusion first wall and blanket since no current blanket concept is considered satisfactory or has been built and proven. The first wall and blanket in magnetic fusion reactors form a vital and complex system, as it must satisfy different functions such as power extraction, tritium breeding, plasma containment, radiation shielding, and safety. The list of design requirements is even longer: high enough tritium production for fusion self-sufficiency, low material activation, decay heat and shutdown dose rates, high thermal efficiency, high-capacity factor, high magnets-divertor-vacuum vessel-first wall life, low corrosion, low cost, and intrinsically safe (requiring minimal licensing). Despite fifty-plus years of research, the first wall and blanket concepts proposed suffer from fundamental technical problems and immaturity (TRL=2-3) that jeopardize the timely delivery of a commercial fusion power plant. A fusion first-wall blanket has never been built nor tested, and a "winning", practical functioning design requires enough engineering margins (high enough tritium breeding considering the uncertainty, etc.), manufacturing simplicity, ease of continuous operation, maintenance, and low cost. A new, groundbreaking blanket concept called "Nested Pebble Bed Blanket" (NesPeB) was developed at ORNL under the successful ARPA-E GAMOW FERMI project (patent application allowed by the USPTO). The NesPeB blanket concept addresses current blanket concepts' shortcomings and technical immaturity, paving the way for accelerated delivery of fusion power plants. NesPeB is based on nested pebbles, which are binary-sized lithium-ceramic pebbles enclosed in "Beryllide" perforated and coated spherical shells, which are also binary-sized, stacked on top of each other, forming a "bed" and cooled by Nitrogen gas also "sweeping" the Helium and Tritium generated by the neutron irradiation of Lithium; the vacuum vessel plasma facing material is Molybdenum-96 and -97 with the first wall cooled by Helium while the divertor armor is made of Tungsten. The simulations of the NesPeB blanket using Fusion Reactors Models Integrator (FERMI) are encouraging as they estimate a tritium breeding ratio (TBR) greater than 1.2 using natural Lithium, acceptable pressure drop, and excellent heat transfer properties. Furthermore, the NesPeB blanket is not limited by magneto-hydro-dynamics (MHD) effects, is designed for online refueling, relies on existing tritium extraction technologies, has a simple construction, and limits the corrosion and chemical reactivity problems. NesPeB has the potential to be transformational and disruptive since it can solve all the main, challenging technical problems of fusion device blankets and accelerate a pilot plant delivery for 10 or more years.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heat Integration Optimization and Dynamic Modeling Investigation for Advancing the Coal-Direct Chemical Looping Process

The purpose of the project is to address the optimization and startup operation of a modular coal direct chemical looping (CDCL) combustion system integrated with a steam cycle for power generation to reduce the risks involved in further scale-up of the technology. The modular reactor design of the CDCL process provides flexibility in the fabrication of the reactor and in its operating capacity (i.e. turndown ratio) at the cost of a more complex heat exchange network (HEN) design and integration. To address the technology gaps and advance the efficiency and economic feasibility of the CDCL technology, the project will perform a detailed and comprehensive analysis of the integration of a modular CDCL reactor system and a steam cycle system under both static and transient conditions via HEN process performance simulations and system dynamic modeling, respectively. The scope of work consists of 1) Experimental and computational studies of the CDCL combustor reactor 2) Comprehensive static (i.e. steady-state) system HEN design analysis in CDCL 550 MWe commercial unit for power generation and 3) Dynamic modeling of site specific design of 10MWe CDCL large pilot plant. The project team has successfully developed and validated a kinetic model for the oxidation of oxygen carriers in the combustor using the unreacted shrinking core model (UCSM). The model is capable of capturing the oxidation kinetics of fully or partially reduced oxygen carrier particles. A computational fluid dynamics (CFD) model is developed to simulate the hydrodynamics, heat transfer, and chemical reaction occurring in the CDCL combustor. The model is developed in MFIX and ANSYS Fluent. Key aspects of CDCL combustor operation, including heat transfer, oxygen carrier oxidation, and the transport of oxygen carrier particles, are simulated using this CFD model. The HEN for a commercial scale 550 MWe CDCL power plant is simulated and optimized using ASPEN Plus. Practical design considerations are incorporated based on industrial experiences. The performance and cost for the commercial CDCL plant is updated based on these analyses. A dynamic model for the 10 MWe CDCL pilot plant is developed in ProTRAX simulation software. The model is based on the pilot plant design developed in project DE-FE0027654 “10 MWe CDCL Large Pilot Plang – Pre-FEED Study” and the steam cycle data obtained from Dover Light & Power plant. The transient behaviors during pilot plant load variation are simulated using the dynamic model.

01 COAL, LIGNITE, AND PEAT↗

Measured Performance of Over the Range Microwave Range Hoods

The California residential building code requires kitchen exhaust ventilation to protect indoor air quality. The requirement can be met with a kitchen exhaust fan or a range hood that conforms to airflow and sound specifications based on certified, standard test results. Appliances that integrate an exhaust fan with an over the range microwave (OTRs) are popular for their space saving utility; but for years there were none with the certified performance data required for building code compliance. This project, initiated during that period, aimed to evaluate OTR models found in new California homes and compare their performance to range hoods that minimally met code requirements. The study aimed to expand on limited information available about OTR performance with a particular focus on measuring the fraction of cooktop-generated air pollutants that are captured and removed by the exhaust devices, a parameter called “capture efficiency”. Airflow and capture efficiency (CE) were measured in a simulated kitchen in Berkeley Lab’s FLEXLAB facility. Airflows were measured using several variations of a balanced-pressure flow method (Walker et al. 2001) including a protocol that had been used in the California Healthy Efficient New Gas Homes (HENGH) field study. Measurements were made for six OTRs observed in the field study, including three with certified test results (published after the start of this project) for airflow and sound. Measurements were also made on two standard range hoods with comparable airflows and costs to the OTRs, when accounting for the microwave functionality. CE was measured using the CO 2 emitted from burners while heating pots of water (POW) as a tracer and calculating the ratio of added CO 2 in the exhaust flow over the total CO 2 generated from burning fuel. Results show that OTRs generally met the California code requirements for airflow, which are the same as those of the residential ventilation standard of ASHRAE. It was determined that the field protocol used in HENGH study homes was biased low by ~14% on average. The CE performance of OTRs tested in this study were consistent with those tested under controlled conditions in prior studies, showing CE increasing with airflow and being higher for emissions occurring at the back cooktop burner(s) compared with front burner emissions. The measured CE covered a range of 40% to 85% for the front burners and 60% to 100% for the back burners. The relationship of CE to airflow for OTRs was within the range of those found for standard range hoods in this study and prior studies, with the key caveat that OTRs appear to have more consistent CE performance for emissions on the front burner.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Differential cross-sections for events with missing transverse momentum and jets measured with the ATLAS detector in 13 TeV proton-proton collisions

Measurements of inclusive, differential cross-sections for the production of events with missing transverse momentum in association with jets in proton-proton collisions at √s = 13 TeV are presented. The measurements are made with the ATLAS detector using an integrated luminosity of 140 fb –1 and include measurements of dijet distributions in a region in which vector-boson fusion processes are enhanced. They are unfolded to correct for detector resolution and efficiency within the fiducial acceptance, and are designed to allow robust comparisons with a wide range of theoretical predictions. A measurement of differential cross sections for the Z → νν process is made. The measurements are generally well-described by Standard Model predictions except for the dijet invariant mass distribution. Auxiliary measurements of the hadronic system recoiling against isolated leptons, and photons, are also made in the same phase space. Ratios between the measured distributions are then derived, to take advantage of cancellations in modelling effects and some of the major systematic uncertainties. These measurements are sensitive to new phenomena, and provide a mechanism to easily set constraints on phenomenological models. To illustrate the robustness of the approach, these ratios are compared with two common Dark Matter models, where the constraints derived from the measurement are comparable to those set by dedicated detector-level searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

COMPUTATIONAL MODELING OF IGNITION AND PREMIXED FLAME PROPAGATION INITIATED BY A PRE-CHAMBER TURBULENT JET

Addressing the pressing need for reduced carbon emissions, Turbulent Jet Ignition (TJI) emerges as a promising technology for ultra-lean combustion, offering enhanced thermal efficiencies and minimized cyclic variability in spark-ignited engines. To facilitate rapid testing and integration of this technology, a robust computational modeling framework is crucial. This study delves into the predictive capabilities of computational models for main-chamber ignition and premixed flame propagation using a single-cycle TJI rig measured by Biswas et al. (Applied Thermal Engineering, vol 106, 2016). Employing an open-source compressible flow simulation solver with Large Eddy Simulation (LES) for turbulence modeling, the investigation integrates the conventional Laminar Finite Rate Chemistry (LFRC) model alongside the transported Probability Density Method (PDF) for turbulence-chemistry interaction. A fully-consistent Eulerian Monte-Carlo Fields (EMCF) method is utilized to approximate the transported PDF, while Interaction by Exchange with Mean is employed to close micro-mixing terms in stochastic differential equations. A reduced chemical reaction mechanism with 21 species and 84 reactions (DRM-19) is used for solving chemical kinetics, and a double Gaussian energy deposition model is used to approximate the spark ignition in the pre-chamber. An unstructured O-grid mesh with 0.3 million cells in the prechamber and 1 million cells in the main chamber is employed. Results are divided into two phases: pre-chamber initialization and full TJI simulations. Validation of the predicted pre-chamber flame propagation and the lean ignition in the main-chamber is carried out by using available experimental data. Under quiescent conditions, both the LFRC and transported PDF methods largely underestimate the flame speed and subsequent pressure growth in the pre-chamber. A linear momentum forcing technique is applied to investigate the impact of initial turbulence in the pre-chamber, demonstrating a notable influence on flame propagation. Fine-tuning of the forcing coefficient reproduces the sudden pressure growth observed in the experiment. The experimentally validated pre-chamber simulation serves as the initial condition for the full TJI simulations. It is found that the LFRC model fails to predict lean-ignition in the main-chamber, resulting in a misfiring event. Incorporation of turbulence-chemistry interaction using the transported PDF method substantially improves the prediction of the ignition event in the main-chamber, achieving fair qualitative agreement and quantitative validation of combustion parameters within ±10% of the reported experimental data. The rich simulation results consisting of a full set of statistical description of the thermo-chemical states enable us to gain deep insights into the ignition mechanisms in the main chamber, which is limited when done experimentally. A novel dual ignition phenomenon is revealed in the TJI rig for the first time. Initially, a primary ignition kernel is formed at a downstream location which eventually detaches from the main jet. As the jet momentum decreases, a secondary ignition event follows, this time at a more upstream location which eventually combines with the primary ignition kernel to form a single connected flame front. Investigation of these ignition sequences in chemical composition space reveal distinct differences between the two. The primary ignition event in the main-chamber is followed by a large concentration of active radicals from the pre-chamber jet, accelerating the chain-branching steps, characterizing what has been referred to as flame ignition. In contrast, the secondary ignition occurs in the absence of active radicals in the pre-chamber jet, hence characterized as jet ignition. Further analysis of the effect of pre-chamber jet characteristics on lean ignition in the main-chamber is conducted by setting up cases with different initial pressure ratios (por) between the two chambers, a non-dimensional parameter, ranging from 1.2 to 3.2. As the initial pressure ratio increases, jet momentum increases, with dual ignition observed in cases above por= 2.2. Case with por= 3.2 lead to misfiring. The effect of ignition sequence on global combustion characteristics of TJI is analyzed. Dual ignition events lead to non-monotonicity in combustion characteristics such as global reaction progress variable, flame penetration, and global heat release rate. In dual ignition events, although the rate of fuel consumption and global heat release rate is initially lower, the secondary ignition leads to a sudden increase in flame surface area, resulting in a sudden jump and promoting the overall performance of the TJI system.

42 ENGINEERING↗

Time-dependent scenario modeling for the ST-E1 fusion power plant

ST-E1 is a low aspect ratio fusion power plant being designed by Tokamak Energy targeting 1.5 GW of fusion power. Characterization of the ST-E1 flat-top scenario is described elsewhere McNamara et al (2026 Nucl. Fusion 66 086008); here we focus on addressing the question of how to ramp-up the ST-E1 plasma from an initial state following breakdown and flux-surface formation to the target flat-top state. Being low-aspect ratio, the available solenoid flux of ST-E1 is limited. Therefore, particular consideration is placed on developing ramp-up scenarios that predominantly use inductive flux provided by external vertical field coils. Through time-dependent modeling with METIS, we show that this is possible when the ramp-up is performed at relatively high plasma density: although auxiliary current drive efficiency is reduced, this is significantly outweighed by (1) higher electron-ion collisional equilibration, (2) higher fusion power once ions become sufficiently hot, (3) higher poloidal beta for increased vertical-field flux, and (4) potentially favorable exhaust compatibilities. Ultimately, we show the target ST-E1 flat-top performance can be reached after a ramp-up period lasting 150 s using less than 40 Vs of solenoid flux (with vertical field providing ∼ 90 Vs of flux). The sensitivity to model assumptions are presented, with the general observation that deleterious effects can be mitigated through minor alterations of the auxiliary power temporal waveform and/or total auxiliary power level. The impact of a solenoid and the auxiliary power mix (electron cyclotron heating only versus electron and ion cyclotron heating) on the ST-E1 ramp-up success are also discussed in appendices. On this latter topic, we show that the effect of direct-ion heating during ramp-up is obscured by the uncertainty in the pedestal dynamics, identifying a clear line of future work required to make a definite decision on the ST-E1 auxiliary power mix.