Search NASA⌕ Search

SEARCH · Search NASA

Results for “Interface Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Serpentine Magnet Designs for the Interaction Region of the Electron-Ion Collider (EIC)

The Electron-Ion Collider (EIC), hosted by Brookhaven National Laboratory, is designed to deliver a peak luminosity of 1 × 10 34 cm −2 sec −1 . The interaction region (IR) of the EIC imposes several constraints in terms of field quality, aperture, and spatial layout, which necessitates the development of several unique superconducting serpentine direct wind magnets. These magnets are constructed using either a single strand or a small-diameter 6-around-1 NbTi cable, presenting unique challenges for design and optimization. This paper introduces a new computational code specifically developed to streamline and integrate the design process for these magnets, enabling faster design iterations while addressing their complex requirements. Here, in this paper, we first introduce the code, which builds on established electromagnetic fundamentals. The code incorporates tools for optimizing winding patterns and for correcting magnetic multipoles; additionally, it interfaces with established magnet design software. We also present the design of several serpentine magnets for the EIC IR, demonstrating the code’s capability to deliver precise and efficient solutions. These designs highlight the code’s ability to accelerate the development cycle, ensuring the serpentine magnets meet the demanding specifications of the EIC project.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chemo‐Mechanics Interplay Dictates Interface Instability and Asymmetry in Plating and Stripping of Sodium Metal Electrodes

Abstract The development of practical sodium (Na) metal batteries is hindered by key challenges including dendrite growth, dead metal formation, and unstable solid electrolyte interphase (SEI) growth. A fundamental understanding of the chemo‐mechanical interactions at the Na/SEI interface is critical for designing stable Na metal electrodes. In this work, the coupled electrochemical‐mechanical processes governing the morphological evolution and stability of Na metal during plating and stripping are investigated. The heterogeneous nature of transport and morphological interactions at the Na/SEI interface is revealed to result in nonuniform mechanical overpotentials and reaction fronts, eventually leading to Na filaments or pits. The spatio‐temporal evolution of stress heterogeneities during Na plating and stripping is shown to be asymmetric, manifesting in varying morphological nonuniformities and instability modes. The crucial role of external pressure in modulating the electrochemical‐transport interactions, the mechanical response of Na, and the localized reaction currents and stresses at the Na/SEI interface is demonstrated. At different external pressure conditions, the correlation between transport heterogeneities in the SEI and the onset and propagation of interface instability has been delineated. This work highlights the need for synergistic tailoring of external pressure and SEI heterogeneity toward achieving stable electrodeposition and dissolution in Na metal electrodes.

Singla, Aditya [School of Mechanical Engineering P↗

Constellation: The autonomous control and data acquisition system for dynamic experimental setups

The operation of instruments and detectors in laboratory or beamline environments presents a complex challenge, requiring stable operation of multiple concurrent devices, often controlled by separate hardware and software solutions. These environments frequently undergo modifications, such as the inclusion of different auxiliary devices depending on the experiment or facility, adding further complexity. The successful management of such dynamic configurations demands a flexible and robust system capable of controlling data acquisition, monitoring experimental setups, enabling seamless reconfiguration, and integrating new devices with limited effort. This paper presents Constellation, a flexible and network-distributed control and data acquisition software framework tailored to laboratory and beamline environments, that addresses the limitations of existing solutions. The framework is designed with a focus on extensibility, providing a streamlined interface for instrument integration. It supports efficient system setup via network discovery mechanisms, promotes stability through autonomous operational features, and provides comprehensive documentation and supporting tools for operators and application developers such as controllers and logging interfaces. At the core of the architectural design is the autonomy of the individual components, called satellites, which can make independent decisions about their operation and communicate these decisions to other components. This paper introduces the design principles and framework architecture of Constellation, presents the available graphical user interfaces, shares insights from initial successful deployments, and provides an outlook on future developments and applications.

Autonomy↗

Tough and circular glass fiber composites via a tailored dynamic boronic ester interface

Glass fiber reinforced polymer (GFRP) composites are valued for their strength and cost-effectiveness. However, traditional GFRPs often face challenges for end-of-life recycling due to their non-depolymerizable thermoset matrices, and long-term performance due to inadequate interfacial adhesion, which can lead to fiber–matrix delamination. Here, in this work, we have designed dynamic fiber–matrix interfaces to allow tough and closed-loop recyclable GFRPs by utilizing a vitrimer, derived from upcycled polystyrene-b-poly(ethylene-co-butylene)-b-polystyrene (SEBS) with boronic ester (S-Bpin) and amine-based diol crosslinker. The boronic ester groups in S-Bpin form dynamic covalent bonds with the naturally present hydroxyl groups on the unsized GF surface, which eliminates the need for fiber sizing and enables facile closed-loop recyclability of both the fibers and the vitrimer matrix. The resulting strong fiber–matrix interface, depicted by the Raman mapping, leads to a 552% increase in-plane shear toughness (6.2 ± 0.3 MJ m -3 ) and 27% ultimate tensile strength (361 ± 89.2 MPa) compared to those of the conventional epoxy-based matrix (0.95 ± 0.05 MJ m -3 and 264 ± 59.7 MPa, respectively). The network rearrangement through dynamic boronic ester exchange enables fast thermoformability and repairability of micro-cracks at elevated temperatures. Additionally, both the matrix and composite demonstrate strong adhesion to various surfaces including steel and glasses exhibiting ≥6 MPa lap shear strength, which expands their suitability for diverse industrial applications. The readily created dynamic interface between boronic ester functionalized vitrimer and neat GFs presents a promising strategy for developing closed-loop recyclable, multifunctional structural materials, offering a sustainable alternative to non-recyclable thermoset GFRPs and contributes to a circular economy in composite materials.

36 MATERIALS SCIENCE↗

Molecular Interlocking Multidimensional Modulations of Cathode‐Electrolyte Interface for Constructing High Energy Density Quasi‐Solid‐State Batteries

Gel polymers are regarded as a promising candidate electrolyte for lithium-metal quasi-solid-state batteries, primarily due to their high ionic conductivity and solid-liquid synergistic properties. However, challenges such as interfacial side reactions, limitations in Li + transport caused by interfacial issues, and leaching of transition metals from the cathode have yet to be effectively solved. Herein, a novel gel electrolyte modulation strategy based on electrostatic filler assembly is proposed to address the issues of ineffective capacity utilization and inadequate cycling stability of high-energy-density cathode materials in solid-state lithium-ion batteries. It constructs a 3D interpenetrating charge-bridge network that effectively tackles the phase-separation challenge between fillers and electrolytes at the molecular level. Meanwhile, the molecular interlocking structure effectively inhibits the electrolyte erosion. More critically, it optimizes and stabilizes the cathode-electrolyte interface film, which facilitates the conduction of Li + -ions through a size-sieving mechanism. Consequently, this strategy enables effective adaptation across diverse high-energy-density cathode materials with satisfactory capacity performance (170.4 mAh g −1 at 4.5 V/1 C for LiNi 0.6 Co 0.2 Mn 0.2 O 2 and 194.0 mAh g −1 at 4.3 V/1 C for LiNi 0.9 Co 0.08 Mn 0.02 O 2 ). In conclusion, this investigation offers a straightforward and effective reference for addressing the critical challenges of ionic transport and interface stabilization in the design of gel electrolytes.

cathode-electrolyte interface↗

Analysis of the electrical double layer using electrochemical X-ray photoelectron spectroscopy

The element-sensitivity of X-ray spectroscopies offers the potential to disentangle the individual chemistries of water, ions, and adsorbates at the electrode-electrolyte interface in an element-by-element manner. However, targeted experimental design is needed to establish interface-sensitive in situ X-ray spectroscopy in a realistic electrochemical environment. Here, we demonstrate how electrochemical X-ray photoelectron spectroscopy (EC-XPS) in the dip-and-pull geometry can be used to specifically probe the behavior of ions in the electrical double layer. Taking the case study of a polycrystalline Au foil in 50 mM KClO 4 electrolyte, we tracked the electrochemical response of interfacial K + cations across a broad potential range. We show how, in combination with modeling, key parameters such as the potential of zero charge (PZC), ion packing behavior, dielectric saturation, and the electrostatic potential decay in the double layer can be extracted from the data. Importantly, we also analyze how the experimental conditions and non-idealities can influence the results and put forward criteria for reliable experimentation and data analysis.

Dip-and-pull↗

One-dimensional heterocyclic carbene–Au metal–organic frameworks bridging ultra-high vacuum models and scalable liquid-phase growth

The controlled design of molecule–metal interfaces is central to the development of functional nanomaterials for catalysis, sensing, and molecular electronics. Here we show that the adsorption of a Janus-type diimidazolium precursor on gold yields one-dimensional (1D) N-heterocyclic carbene (NHC)–Au–NHC metal organic frameworks (MOFs) featuring positively charged gold nodes. Using synchrotron X-ray photoemission spectroscopy (XPS), near edge X-ray adsorption fine structure (NEXAFS) spectroscopy and scanning tunnelling microscopy (STM), we demonstrate that thermal activation promotes counterion removal and drives the formation of extended 1D arrays, characterized by ∼1.0 nm Au–Au spacing and adatom densities up to 0.6 atom nm −2 (∼4% of surface atoms). Importantly, we translate this ultra-high vacuum (UHV) benchmark into a scalable solution-phase protocol in ethanol, enabling 1D-MOF growth under mild, base-free, open-air conditions. The resulting films retain structural and electronic signatures of UHV-grown systems, bridging model studies and practical synthesis. This approach establishes NHC–metal frameworks as accessible, tunable platforms for catalysis and materials design.

Gold adatoms↗

Impact of Anode to Cathode Crossover in Lithium‐metal Batteries With High‐Nickel Cathodes

The advancement of high-energy-density lithium-metal batteries (LMBs) is hindered by the chemical instability of both lithium-metal anode and high-nickel layered oxide cathodes. While cathode-to-anode crossover is well-documented, the reverse process of anode-to-cathode crossover remains underexplored. Here, we systematically investigate such crossovers and the degradation pathway in pouch cells with a localized high-concentration electrolyte, comparing NMC622, NMC811, and NMC90 cathodes paired with lithium-metal and graphite anodes. Despite delivering higher initial capacities, LMBs exhibit faster capacity fade under long-term cycling at 45 °C. To isolate cathode-side degradation, galvanostatic electrochemical impedance spectroscopy (GEIS) measurements of cycled cathodes paired with delithiated lithium iron phosphate (LFP) counter electrodes reveal significantly higher charge-transfer resistance in cathodes cycled with lithium-metal. Surface characterization via X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) reveals greater electrolyte decomposition on cathodes cycled with lithium metal, leading to thicker, more organic-rich cathode–electrolyte interphases (CEIs), consistent with the elevated charge-transfer resistance observed in GEIS measurements. Notably, NMC90 shows the most pronounced CEI thickening, linking higher cathode surface reactivity to greater susceptibility to anode-to-cathode crossover. This work presents compelling evidence of crosstalk degradation originating from lithium-metal anodes and underscores the importance of cross-interface stability for the design of durable LMBs.

25 ENERGY STORAGE↗

Preheat effects in laser-driven Rayleigh–Taylor instability experiments at intensities greater than $10^{15}$ $\textrm{W}$ $\textrm{cm}^{-2}$ at OMEGA EP and the NIF

The propagation of high-energy X-rays or hot electrons have the potential to alter the initial conditions in experimental target designs, especially at material interfaces, for laser-driven inertial confinement fusion (ICF) and high-energy density (HED) experimental platforms. Hot-electron preheat can drastically modify the initial conditions of experimental targets used to study the deceleration-stage Rayleigh–Taylor instability (RTI) both with and without applied magnetic fields. Therefore, it is necessary to understand and quantify the impact of hot-electron preheat. The hydrodynamic (HD) capabilities in the Ares code are used to study the effects varying levels of preheat can have on RTI evolution. The experimental and computational studies presented in this work demonstrate that at high laser intensities of around or greater than 10 15 W cm −2 , there is hot-electron generation from laser plasma instabilities which induces substantial preheat and impacts the morphology of RTI evolution and even inhibits the intended RTI growth such that it is not observable experimentally. The necessity of better quantifying hot-electron induced preheat and mitigating its impact on such high-intensity direct-drive laser experiments in the future is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface Charge in Electrical Double Layer as a Kinetic Descriptor of Electrocatalytic Reactions

The successful commercialization of electrochemical energy-conversion systems hinges on a deeper understanding of electrocatalytic reaction kinetics. Despite extensive research, a key descriptor that characterizes electrolyte effects on reaction kinetics remains elusive. Here, surface charge in electrical double layers (EDLs) is introduced as a descriptor for electrolyte-dependent kinetics. The surface charge is calculated with a continuum EDL model parameterized by density-functional theory. The model is validated by reproducing the anomalously low slope of Pt(111) in Parsons-Zobel plots. Strong correlations are observed between calculated surface charge and experimental kinetic currents for hydrogen evolution, oxygen reduction, and CO 2 -reduction reactions across various pH levels and cationic species. These correlations can be either promotional or inhibitory, depending on solute-intermediate interactions. In acidic media, incorporating adsorbate charge captures specific adsorption effects in oxygen reduction reaction. In conclusion, these findings establish surface charge density as a key descriptor for electrolyte-dependent kinetics, which will guide the design of the electrode/electrolyte interface.

Adsorption↗

On-the-fly data set combinations with RNTuple

With the expected data volume increase for HL-LHC and the even more complex computing challenges set by future colliders, the need for efficient data storage and processing becomes more pressing. ROOT’s next-generation data format and I/O subsystem, RNTTuple, is designed to address these challenges. RNTTuple already demonstrates a clear improvement in storage and I/O efficiency, as well as overall stability and robustness with respect to its predecessor, TTTree. These improvements provide a solid baseline to introduce novel extensions to common high-energy and nuclear physics (HENP) workflows. Notably, many workflows could benefit from the ability to arbitrarily join and chain data set samples at runtime, which could reduce overall storage requirements and improve application runtime and ergonomics. In this paper, we present the RNTupleProcessor, which enables HENP data set combinations with RNTuple. We will discuss the main design considerations, present the interfaces to support data set combinations and show how they integrate in typical workflows.

de Geus, Florine Willemijn [CERN; Twente U., Ensch↗

Language and design evolution of the OpenMC Monte Carlo particle transport code

The OpenMC Monte Carlo particle transport code has been continuously developed for 13 years by a large community of contributors. In that time span, the codebase has undergone significant changes that have redefined what OpenMC is and made it an enduring presence in the nuclear science and engineering community. In this paper, we discuss the evolution of programming language use in OpenMC, trends in the overall design of the programming interfaces, and implications for the future of the code.

Romano, Paul (ORCID:000000021147045X)↗

Application of the portable diagnostic package to the Wisconsin high-temperature-superconducting axisymmetric mirror (WHAM)

We present an application of the Portable Diagnostic Package (PDP) on the Wisconsin High-temperature-superconducting Axisymmetric Mirror (WHAM), which integrates an optical emission spectroscopy (OES) system and an active Thomson scattering (TS) system. The OES system facilitates a comprehensive impurity line survey and enables flow measurements through the Doppler effect observed on impurity lines. Plasma rotation profiles were successfully derived from doubly charged carbon lines. The TS system enabled the first measurements of the electron temperature in commissioning plasmas on WHAM. Notably, the PDP was installed, commissioned, and used to obtain OES and TS data within ∼6 months from project start, enabled by its designed portability and standardized interfaces. These results demonstrate the PDP’s potential to accelerate diagnostic readiness and advance experimental plasma studies.

Doppler effect↗

Packaging a 650V/400A GaN Half-bridge Power Module with Ultra-low Parasitics for Electric Vehicle Drive Applications

This paper proposes a compact and efficient half-bridge power module with three 650 V / 150 A GaN dies in parallel. The power module incorporates a main power printed circuit board (PCB), an interface PCB, and a flex PCB to achieve low parasitics in both power loop and gate-side connection, resolving the issue of high parasitics typically encountered with wire bonding in high-current applications. Additionally, the interface PCB decouples the design constraints between the power loop and the gate loops. The proposed design is optimized with a vertical loop configuration to reduce power loop inductance through magnetic flux cancellation. Finite element analysis indicates that the power loop inductance is 0.58 nH at 100 MHz, while the maximum die junction temperature reaches 131 °C under an ambient temperature of 65 °C and a load current of 385 A. The proposed multi-piece PCB structure reduces the inductance of the drive circuit to minimize EMI and to mitigate false triggering. At the same time, it reduces impedance mismatches across different driver circuits, thereby achieving dynamic current sharing in multi-chip parallel configurations. Under simulation conditions of 400 V / 385 A, the current imbalance among chips was limited to 5 A. A 400 V / 385 A double-pulse test was conducted to experimentally validate the performance of the proposed power module.

30 DIRECT ENERGY CONVERSION↗

Evaluating FRI3D for Cost Savings in Fire Hazard Analysis at DOE Sites

A fire hazard analysis, required for many U.S. Department of Energy (DOE) facilities, is a complex, cumbersome, and costly process. Fire hazard analyses may be viewed as a checkbox, but ideally and in spirit with the DOE-STD-1066, the fire hazard analysis (FHA) should be a part of the workflow and used to help in modifications, maintenance, and improving operational safety. With current FHA development processes, it is both time and cost prohibitive for true integration. A tool called Fire Risk Investigation in 3D or FRI3D was developed under the DOE Light Water Reactor Sustainability program to simplify and automate many aspects of a fire probabilistic risk analysis for existing nuclear power plants. The FRI3D tool automates fire scenarios by combining approved fire simulation codes, U.S. Nuclear Regulatory Commission fire calculations methods, 3D modeling and visualization, and probabilistic risk analysis models into a single workflow supported with a user interface. FRI3D was initially designed for used in combination with a PRA, this case study, evaluated using FRI3D for a plant modification, determined the benefits that detailed fire modeling can have for U.S. Department of Energy facilities with or without a PRA model. It also looked at what tasks from DOE requirements could be reduced using the tool and what is needed to integrate fire hazard analysis into site workflow.

97 - MATHEMATICS AND COMPUTING↗

Human-system Interface Style Guide for ACORN Control System

The purpose of this style guide is to provide a clear, consistent framework for the design and development of human system interfaces (HSIs) used throughout the Fermilab accelerator complex. It establishes a shared visual and interaction foundation to ensure that interfaces remain intuitive, effective, and cohesive, regardless of when or by whom they are developed. By adhering to these guidelines, developers can avoid introducing unnecessary deviations that compromise usability or increase system training burden. This consistency is especially critical in long-term, multi-contributor projects where interface continuity and maintainability are paramount. This document serves as a practical reference for all HSI development activities related to the accelerator control environment. While the guidance provided is comprehensive, it is not exhaustive of every potential design scenario. As such, the style guide is intended to function as a living document, subject to regular review and revision. Updates will be made at least annually to incorporate emerging best practices, operational feedback, and evolving system needs. Areas where detailed guidance is still under development are clearly indicated in gray throughout the document and will be addressed in future revisions according to project priorities.

Hill, Rachael [Idaho Natl. Lab.] (ORCID:0000000263↗