Search NASA⌕ Search

SEARCH · Search NASA

Results for “KeV X-rays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Analysis of Two Models for the Angular Structure of the Outflows Producing the Swift/XRT “Larger-angle Emission” of Gamma-Ray Bursts

The quasi-instantaneous emission from a relativistic surface endowed with a Lorentz factor that decreases away from the outflow symmetry axis can naturally explain the three phases observed by Swift X-Ray Telescope (XRT) in gamma-ray bursts (GRBs) and their afterglows (GRB tail, afterglow plateau, and postplateau) based only on the angular change of the relativistic Doppler boost across the outflow surface. We develop further the analytical formalism of the “larger-angle emission” model for the case of “n-exponential” outflows (where the Lorentz factor Γ dependence of the angular location θ is Γ ~ exp{-(θ/θ c ) n }), and compare its ability to account for the X-ray emission of XRT afterglows relative to that of “power-law” outflows (Γ ∼ θ −g ). Power-law outflows yield longer afterglow plateaus, followed by slower postplateau flux decays than n-exponential outflows, features which may be used in identifying which type of angular structure is at work in a given afterglow. Identifying the Γ(θ) angular structure that accommodates XRT light curves is slightly complicated by the fact that the afterglow X-ray light curve is also determined by how two characteristics of the comoving-frame emission spectrum (peak energy $E'_p$ and peak intensity $i'_p$) change with the angular location or, equivalently, with the Lorentz factor. Here, we assume power-law Γ dependences of those spectral characteristics and find that, unlike power-law outflows, n-exponential outflows cannot account for plateaus with a temporal dynamical range larger than 100 (2 dex in logarithmic space). To capture all the information contained in XRT afterglow measurements (0.3–10 keV unabsorbed flux and effective spectral slope), we calculate 0.3 and 10 keV light curves using a broken-power-law emission spectrum of peak energy and low- and high-energy slopes that are derived from the effective slope measured by XRT. This economical peak energy determination is found to be consistent with the results of more expensive spectral fits. The angular distributions of the Lorentz factor, comoving frame peak energy, and peak intensity (Γ(θ), $E'_p$(θ), $i'_p$(θ)) constrain the (yet-to-be determined) convolution of various features of the production of relativistic jets by solar-mass black holes and of their propagation through the progenitor/circumburst medium, while the $E'_p$(Γ) and $i'_p$(Γ) dependences may constrain the GRB dissipation mechanism and the GRB emission process.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray escape peaks in gamma-ray spectrum acquired by perovskite detector

The X-ray escape peaks are clearly visible in the high-resolution gamma spectra acquired by CsPbBr 3 , credit to the rapidly improving energy resolution of perovskite gamma detectors. But it also raises concerns. If this peak remains as significant as it is, perovskite gamma detectors would have very limited use in complex gamma spectrometry applications. This paper discusses the origin of the escape peaks in CsPbBr 3 detectors, benchmarked against Ge and CZT detectors. The Pb escape peak consists of four escape peaks that are merged together, while the Cs and Br escape peaks are hidden inside the photopeak of 137 Cs (662 keV). These combined effects either create a noticeable gamma peak observed to the left of the 662 keV photopeak when acquired using a high-resolution CsPbBr 3 detector or raise the left slope of the photopeak. We also explore potential methods to mitigate these peaks, such as applying anti-coincidence method. The height of the escape peaks diminishes as the detector volume increases but will not go away entirely. The relationship between the observed Pb escape peak and the detector's dimensions is demonstrated through Monte Carlo simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of automated chemical-guided segmentation and human annotation of soil organic matter in X-ray microcomputed tomography imaging in contrasted soil types

Soil organic matter (OM) formation and persistence is strongly influenced by the spatial distribution of organic substrates and microscale soil heterogeneity by dictating OM accessibility to microorganisms. However, traditional size and/or density fractionation techniques disrupt aggregate architecture, eliminating spatial information needed to fully understand intra-aggregate OM distribution. To quantify three-dimensional OM spatial distribution and automate segmentation in X-ray microcomputed tomography (µCT) imaging without human annotation bias, we developed an iodine gas vapor (I2) based staining workflow that eliminates labor-intensive manual annotation while maintaining segmentation accuracy, using aggregates from four taxonomically diverse soils (Xerofluvent, Haploxeroll Sphagnofibrist, Palehumult) with an 8-fold range of soil organic carbon. Human annotation of 10 µCT slices by the experienced and inexperienced annotators resulted in variations up to 3% in the Dice similarity coefficient (DSC), reflecting a degree of inherent subjectivity of manual labeling. Such inconsistencies are expected to compound as the number of manually annotated slices increases. Dual-energy µCT imaging at 33.1 keV (below the iodine (I) K-edge) and 33.2 keV (above the I K-edge) was used to resolve aggregate microstructure following I2 staining. The automated image subtraction pipeline identified OM regions by the I Kedge induced brightness increases, achieving DSC values of 0.58–0.83 relative to an experienced annotator. Sensitivity analyses revealed that the reconstruction alpha value—optimized via the open-source tool TomocuPy—and the 3D registration slice count were the primary determinants of accuracy, providing a novel benchmark for dual-energy soil imaging. The pipeline without GPU acceleration achieved 9.6 to 43.2 times faster than manual annotation. Using GPU-accelerated image post-processing and affine transformation matrices, the pipeline successfully segmented OM elements for large-scale datasets (3232×3232 pixel, 2048 slices) within ~5200 s from raw file acquisition to segmented output. The high-throughput approach enables the quantification of OM spatial distribution across diverse and heterogeneous soil.

Soil microbial biomass↗

Diagnosing inertial confinement fusion ignition

Abstract Fusion ignition by inertial confinement requires compression and heating of the fusion fuel to temperatures in excess of 5 keV and densities exceeding hundreds of g/cc. In August 2021, this scientific milestone was surpassed at the National Ignition Facility (NIF), when the Lawson criterion for ignition was exceeded generating 1.37MJ of fusion energy (Abu-Shawareb et al 2022 Phys. Rev. Lett. 129 075001), and then in December 2022 target gain >1 was realized with the production of 3.1MJ of fusion energy from a target driven by 2.0MJ of laser energy (Abu-Shawareb et al 2024 Phys. Rev. Lett. 132 065102). At the NIF, inertial confinement fusion research primarily uses a laser indirect drive in which the fusion capsule is surrounded by a high-Z enclosure (‘hohlraum’) used to convert the directed laser energy into a symmetric x-ray drive on the capsule. Precise measurements of the plasma conditions, x-rays, γ -rays and neutrons produced are key to understanding the pathway to higher performance. This paper discusses the diagnostics and measurement techniques developed to understand these experiments, focusing on three main topics: (1) key diagnostic developments for achieving igniting plasmas, (2) novel signatures related to thermonuclear burn and (3) advances to diagnostic capabilities in the igniting regime with a perspective toward developments for intertial fusion energy.

Moore, A. S. (ORCID:0000000221258882)↗

Key advancements toward eliminating the “drive deficit” in ICF hohlraum simulations

This paper, extended from a Letter [Chen et al., Phys. Rev. E 110, L013201 (2024)] published in Phys. Rev. E in 2024, presents detailed results from a set of experiments studying the x-ray drive produced in laser-heated ignition-scale hohlraums at the National Ignition Facility. The results reveal that deficiencies in non-local thermodynamic equilibrium atomics physics calculations of gold emissivity lead to the overestimation of the “M-band” radiation and are responsible for discrepancies in drive predictions vs measurements in these hohlraums. These experiments were performed on ViewFactor targets with the same gas fill and laser pulse shapes as currently used in ongoing ignition experiments. The common hohlraum model with a magnetohydrodynamics heat transport model and a 10%–20% reduction to the M-band absorption and emission opacity can bring the simulations into agreement with several independent measurements, including the absolute radiation flux, the radiation flux in the 2–4 keV spectral range, and spectroscopic measurements of both K-shell dopant and L-shell gold. This new model is applicable to ICF and high-energy density experiments that use gold hohlraums as drivers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ self-ion (Fe + ) irradiation of ODS-FeCrAl alloy fuel cladding materials with different Cr contents: The early stages of Cr-rich α’ phase precipitation

Oxide-dispersion-strengthened FeCrAl (ODS-FeCrAl) alloys are candidate accident-tolerant fuel cladding materials for light water reactors because they demonstrate satisfactory resistance to materials degradation effects such as high-temperature oxidation, radiation-induced swelling, and creep. Their perspective deployment to market is challenged, however, by their inherent susceptibility to irradiation embrittlement caused by the precipitation of the brittle Cr-rich α’ phase at relatively low temperatures (≤475 °C). This work used in situ self-ion irradiation (150 keV Fe + ) in a transmission electron microscope to elucidate the early stages of Cr-rich α’ phase precipitation in three candidate ODS-FeCrAl alloy fuel cladding materials with different Cr contents (10, 12, and 20 wt.%) and microstructures. The early stages of the process resulting in the precipitation of the Cr-rich α’ phase in these three ODS-FeCrAl alloys under Fe + irradiation were investigated at room temperature and 300 °C up to total fluences of 1.7 × 10 15 ions·cm -2 (2 dpa) and 3.4 × 10 15 ions·cm -2 (4 dpa), using three damage dose rates (5 × 10 –5 , 3.3 × 10 –4 , and 2 × 10 –3 dpa·s -1 ). Post-irradiation examination via scanning transmission electron microscopy, energy-dispersive X-ray spectroscopy and electron energy loss spectroscopy suggested that the precipitation of the Cr-rich α’ phase might be promoted by the phase separation of the alloy matrix into Cr-rich and Fe-rich regions. Interestingly, oxygen impurities segregated preferentially in the Cr-rich regions, possibly promoting the radiation-assisted formation of the Cr-rich α’ phase. α’ phase precipitation was more pronounced at room temperature when compared to 300 °C, and it was clearly promoted by the progressive increase in the Cr content of the ODS-FeCrAl alloy.

36 MATERIALS SCIENCE↗

Impact of gas background on XFEL single-particle imaging

Abstract Single-particle imaging (SPI) using X-ray free-electron Lasers (XFELs) offers the potential to determine protein structures at high spatial and temporal resolutions without the need for crystallization or vitrification. However, the technique faces challenges due to weak diffraction signals from single proteins and significant background scattering from gases used for sample delivery. A recent observation of a diffraction pattern from an isolated GroEL protein complex Ekeberg T et al. (Light Sci Appl 13:15, 2024.https://doi.org/10.1038/274s41377-023-01352-7) had similar numbers of signal and background photons. Ongoing efforts aim to reduce the background created by sample delivery, with one approach replacing most of the used gas with helium Yenupuri T et al. (Sci Rep 14:4401, 2024.https://doi.org/10.1038/s41598-024-54605-9). In this study, we investigate the effects of a reduced background on the resolution limits for SPI of isolated proteins under different experiment conditions. As a test case, we used GroEL, and we used experimentally derived parameters for our simulations. We observe that background significantly impacts the achievable resolution, particularly when the signal strength is comparable to the background. This is best exemplified at 6.0 keV, where a background reduction by a factor of 10 leads to a resolution improvement from 1.9 to 1.2 nm, for a dataset of$$10^4$$patterns.

Science & Technology - Other Topics↗

Performance of an X-γ ray detection system based on a thick silicon LGAD

We present the performance of a X-γ ray detection systems based on a 300 µm thick silicon low-gain avalanche diode (LGAD) and of an equivalent Diode structure without the gain layer, read-out by a custom-made low-noise charge amplifier. For the LGAD structure, the multiplication gains M s from 10.2 to 19.3 are measured, and the Equivalent Noise Charge (ENC) components have been studied in detail. As expected, a significant reduction of the white and 1/f voltage series and dielectric ENC components is observed with increasing gain, shortening the optimum peaking time to τ = 0.4÷8 μs depending on the gain value, with respect to the standard diode, while the parallel ENC component increases proportionally to the gain up to M s = 15. Setting the gain M s = 12.7, a minimum ENC = 34.5 electrons r.m.s. (298 eV FWHM) at τ = 1 μs is found. However, the electronic noise, evaluated on the pulser FWHM, is found to only marginally contribute to the width of the spectral lines of a radioactive source, which are dominated instead by the statistical noise of the charge multiplication within the LGAD structure. The spectral lines' excess width is found to be proportional to the signal multiplication gain M s and increases with the energy of the photons. A minimum line width of 850 eV FWHM at 13.9 keV is measured at room temperature, τ = 2 μs and a gain M s = 10.2.

47 OTHER INSTRUMENTATION↗

Directional dependence of equilibrated TLD-400 chips in multiple radiation fields

Fielding of thermoluminescent dosimeters (TLDs) for measurement of photon radiation dose in experiments is the standard practice for γ-irradiation facilities, pulsed power x-ray facilities, and reactor facilities at Sandia National Laboratories (SNL). Due to the high-dose experimental conditions and the mixed ( 1 n, γ) fields in these facilities, SNL radiation metrologists have historically used CaF 2 :Mn TLDs (also known as TLD-400). Recent inquiries to the radiation metrology staff have raised concerns that the aluminum-equilibrated TLD-400 chips may exhibit a directionally dependent response. The metrologists were asked whether the dose measured by the chip may be impacted by the angle of incidence on the equilibrated TLD. To provide a thorough answer to this query, a set of adjoint Monte Carlo radiation transport calculations was performed for three different equilibrated TLDs as well as bare TLD chips using the Integrated Tiger Series (ITS) code. The key feature of the adjoint calculations performed in this study is that each photon escaping the modeled geometry was tallied into angular bins to provide information on both the energy and angular dependence of the equilibrated chip. After the adjoint Monte Carlo calculations were completed, the resulting energy-dependent response function for each angular bin was convolved with multiple photon energy spectra representing various radiation facilities at SNL. The radiation facilities selected for analysis span a range of photon energies from approximately 1 keV up to approximately 20 MeV. Thus, the presented results are applicable to a wide variety of radiation facilities around the world. Although the bare TLD-400 chip was expected to display the largest variation due to the photon angle of impact on the dosimeter, the dosimeter with the thinnest aluminum equilibrator (SNL thin equilibrated TLD-400) was determined to have the biggest differential between the impact angle with the maximum dose ( D max ) and the impact angle with the minimum dose ( D min ). However, the SNL normal equilibrated TLD-400 chip demonstrated a dramatic reduction in that differential between maximum and minimum dose angles. The reduction in this differential is one of the dominant factors in experimenters’ choice to field these dosimeters at SNL radiation facilities. The results from the PNNL (Hanford) energy-flattening field capsule are consistent with the previous publications. The differential dose responses due to the photon impact angle indicate that experimenters should strive to field their TLD-400 dosimeters in a consistent manner to avoid additional uncertainty in the measurements based on dosimeter orientation.

Adjoint radiation transport↗

A platform for non-local thermodynamic equilibrium atomic physics research using the buried layer target approach at a kJ level laser facility

Here we present a design and first use of a kJ level laser facility for research of non-local thermodynamic equilibrium atomic physics using the buried layer target method. The target design included a metal layer buried inside a plastic tamper with thicknesses tailored to the expected laser intensities. The target was illuminated from each side by two laser beams with intensities of 0.5–5 × 10 14 W/cm 2 . The advanced diagnostic suite included static and time-resolved imagers and spectrometers with various spectral resolutions. A 3D printed dual elliptically curved spectrometer is presented, and its results are compared to a traditional crystal spectrometer. Experimental results and radiation hydrodynamic simulations demonstrate that the target achieved the desired thermodynamic conditions of n e ≈ 10 21 –10 22 cm -3 and T e ≈ 1–2 keV.

3D printing↗

Efficient backward x-ray emission in a finite-length plasma irradiated by a laser pulse of picosecond duration

Motivated by experiments employing picosecond-long, kilojoule laser pulses, we examined x-ray emission in a finite-length underdense plasma irradiated by such a pulse using two-dimensional particle-in-cell simulations. We found that, in addition to the expected forward emission, the plasma also efficiently emits in the backward direction. Our simulations reveal that the backward emission occurs when the laser exits the plasma. The longitudinal plasma electric field generated by the laser at the density down-ramp turns around some of the laser-accelerated electrons and re-accelerates them in the backward direction. As the electrons collide with the laser, they emit hard x rays. The energy conversion efficiency is comparable to that for the forward emission, but the effective source size is smaller. We show that the picosecond laser duration is required for achieving a spatial overlap between the laser and the backward energetic electrons. At peak laser intensity of 1.4×1020 W/cm2, backward-emitted photons (energies above 100 keV and 10° divergence angle) account for 2×10−5 of the incident laser energy. This conversion efficiency is three times higher than that for similarly selected forward-emitted photons. The source size of the backward photons (5 μm) is three times smaller than the source size of the forward photons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gold L-shell emission spectroscopy as a temperature diagnostic in laser-driven experiments

Measurements of plasma conditions within gold hohlraums are challenging but provide important information about hohlraum energy transport. To date, there are no reliable passive diagnostic approaches that produce information about the hohlraum plasma conditions. Gold L-shell emission spectroscopy is a promising method to measure the electron temperature in multi-keV gold hohlraum plasmas. In this study, we compare time-resolved measurements of gold L-shell spectra against a more conventional electron temperature-sensitive diagnostic, K-shell emission from zinc, a mid-Z dopant. The Au L-shell and Zn K-shell spectra are taken simultaneously. The analysis of both sets of data exhibits good agreement with a singular rad-hydro model, suggesting a similar evolution in the mean electron temperature of the hohlraum plasma. These findings support the use of L-shell spectroscopy of gold as a method to study gold plasma conditions.

Emission spectroscopy↗

Exploring high-intensity laser-driven secondary sources via high-order spectral pulse shaping for high-energy-density experiments

We present here the results of an investigation that aims to explore the impact of spectral pulse shaping on the generation of high-energy electrons (>1 MeV) and x rays (∼5–9 keV) using a high-intensity (I∼10 21 W/cm 2 ) laser system. The study involved a systematic scan of a broad parameter space in group delay dispersion and third-order dispersion, with variations up to 4 × 10 3 fs −2 and 6 × 10 4 fs −3 , respectively, to identify optimal conditions for enhancing secondary source yields. Several spectral phase conditions were found to significantly enhance the generation of hot electrons and x rays by amounts reaching up to 50% relative to the transform-limited pulse. The experiment, conducted at the Scarlet laser facility (800 nm, 5 J, 30 fs) at the Ohio State University, highlights the potential of spectral pulse shaping as a powerful tool for tuning secondary laser-driven sources. These findings are particularly relevant for advancing brighter x-ray and electron probes for high-energy-density science.

Physics - Plasma physics↗

First use of an InSb crystal for x-ray imaging spectroscopy of highly ionized tungsten in the Wendelstein 7-X stellarator

Advances in time and space resolved measurements of highly charged states of tungsten (W) through x-ray imaging spectroscopy have enabled investigation of impurity transport in the Wendelstein 7-X (W7-X) stellarator. The high-resolution x-ray imaging spectrometer (HR-XIS) system on W7-X utilizes the Bragg diffraction properties of a set of multiple crystals to measure a range of impurity emission lines within sections of the 1–7 Å wavelength range, including transitions of W. A new indium–antimonide crystal has been installed on the HR-XIS system to allow viewing of the 5.5–6.2 Å region focusing on emissions of W. Consequently, many bright W emission lines from W 40+ to W 47+ were observed in this wavelength range, both in plasmas with injected W and in those with only intrinsic W impurity sources, showing the high sensitivity of the diagnostic. Three W 46+ emissions correspond in wavelength and intensity with calculated photon emissivity coefficients and can be exploited for W transport and concentration applications in plasmas with T e ≳ 2.1 keV. Here, an estimate of the core W density behavior in two separate turbulence-reduced ‘high-performance’ (HP) discharges on W7-X is done using the 5.6893 Å W 46+ line. The n W behavior in HP scenarios can be explained by previous experimental results and neoclassical predictions.

XICS↗

XRISM/Resolve view of Abell 2319: Turbulence, sloshing, and ICM dynamics

Here, we present results from XRISM/Resolve observations of the core of the galaxy cluster Abell 2319, focusing on its kinematic properties. The intracluster medium (ICM) exhibits temperatures of approximately 8 keV across the core, with a prominent cold front and a high-temperature region (⁠~11 keV) in the north-west. The average gas velocity in the 3' x 4' region around the brightest cluster galaxy (BCG) covered by two Resolve pointings is consistent with that of the BCG to within 40 km s -1 ⁠ and we found modest average velocity dispersion of 230–250 km s -1 ⁠. On the other hand, spatially resolved spectroscopy reveals interesting variations. A blueshift of up to ~230 km s -1 ⁠ is observed around the east edge of the cold front, where the gas with the lowest specific entropy is found. The region further south inside the cold front shows only a small velocity difference from the BCG; however, its velocity dispersion is enhanced to ~400 km s -1 ⁠, implying the development of turbulence. These characteristics indicate that we are observing sloshing motion with some inclination angle following BCG and that gas phases with different specific entropy participate in sloshing with their own velocities, as expected from simulations. No significant evidence for a high-redshift ICM component associated with the subcluster Abell 2319B was found in the region covered by the current Resolve pointings. These results highlight the importance of sloshing and turbulence in shaping the internal structure of Abell 2319. Further deep observations are necessary to better understand the mixing and turbulent processes within the cluster.

Astronomy and AstroPhysics↗

Multiwavelength Afterglow Analysis of GRB 221009A: Unveiling the Evolution of a Cooling Break in a Wind-like Medium

Gamma-ray bursts (GRBs) are the most energetic explosions in the Universe, and their afterglow emission provides an opportunity to probe the physics of relativistic shock waves in an extreme environment. Several key pieces for completing the picture of GRB afterglow physics are still missing, including jet properties, the emission mechanism, and particle acceleration. Here, we present a study of the afterglow emission of GRB 221009A, the most energetic GRB ever observed. Using optical, X-ray, and gamma-ray data up to approximately 2 days after the trigger, we trace the evolution of the multiwavelength spectrum and the physical parameters behind the emission process. The broadband spectrum is consistent with the synchrotron emission emitted by relativistic electrons with its index of p = 2.29 ± 0.02. We identify a break energy at keV and an exponential cutoff at GeV in the observed multiwavelength spectrum. The break energy increases in time from $16.0^{+7.1}_{-4.9}$ keV at 0.65 days to $46.8^{+25.0}_{-15.5}$ keV at 1.68 days, favoring a stellar-wind-like profile of the circumburst medium with k = 2.4 ± 0.1 as in ρ(r) ∝ r -k . The high-energy attenuation at around 0.4 to 4 GeV is attributed to the maximum of the particle acceleration in the relativistic shock wave. This study confirms that the synchrotron process can explain the multiwavelength afterglow emission and its evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Bulk Motions in the Black Hole Jet Sheath as a Candidate for the Comptonizing Corona

Abstract Using two-dimensional general relativistic resistive magnetohydrodynamic simulations, we investigate the properties of the sheath separating the black hole jet from the surrounding medium. We find that the electromagnetic power flowing through the jet sheath is comparable to the overall accretion power of the black hole. The sheath is an important site of energy dissipation as revealed by the copious appearance of reconnection layers and plasmoid chains. About 20% of the sheath power is dissipated between 2 and 10 gravitational radii. The plasma in the dissipative sheath moves along a nearly paraboloidal surface with transrelativistic bulk motions dominated by the radial component, whose dimensionless 4-velocity is ∼1.2 ± 0.5. In the frame moving with the mean (radially dependent) velocity, the distribution of stochastic bulk motions resembles a Maxwellian with an “effective bulk temperature” of ∼100 keV. Scaling the global simulation to Cygnus X-1 parameters gives a rough estimate of the Thomson optical depth across the jet sheath, ∼0.01–0.1, and it may increase in future magnetohydrodynamic simulations with self-consistent radiative losses. These properties suggest that the dissipative jet sheath may be a viable “coronal” region, capable of upscattering seed soft photons into a hard, nonthermal tail, as seen during the hard states of X-ray binaries and active galactic nuclei.

Sridhar, Navin (ORCID:0000000255199550)↗

The XRISM/Resolve View of the Fe K Region of Cyg X-3

The X-ray binary system Cygnus X-3 (4U 2030+40, V1521 Cyg) is luminous but enigmatic owing to the high intervening absorption. High-resolution X-ray spectroscopy uniquely probes the dynamics of the photoionized gas in the system. In this Letter, we report on an observation of Cyg X-3 with the XRISM/Resolve spectrometer, which provides unprecedented spectral resolution and sensitivity in the 2–10 keV band. We detect multiple kinematic and ionization components in absorption and emission whose superposition leads to complex line profiles, including strong P Cygni profiles on resonance lines. The prominent Fe xxv Heα and Fe xxvi Lyα emission complexes are clearly resolved into their characteristic fine-structure transitions. Self-consistent photoionization modeling allows us to disentangle the absorption and emission components and measure the Doppler velocity of these components as a function of binary orbital phase. We find a significantly higher velocity amplitude for the emission lines than for the absorption lines. The absorption lines generally appear blueshifted by ∼−500–600 km s −1 . We show that the wind decomposes naturally into a relatively smooth and large-scale component, perhaps associated with the background wind itself, plus a turbulent, denser structure located close to the compact object in its orbit.

Audard, Marc (ORCID:000000034721034X)↗