Search NASA⌕ Search

SEARCH · Search NASA

Results for “Key performance indicator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

42 ENGINEERING↗

High-Temperature Multi-Process Sensor Development and Demonstration at a Full-scale PC Combustion System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

High-Temperature Multi-Process Sensor Development and Demonstration at a Full-scale PC Combustion System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Photostability of Ambient-Processed, Conjugated Polymer Electrochromic Devices Encapsulated by Bioderived Barrier Films

Polymer-based electrochromic devices (ECDs) are a promising technology for enabling low-voltage, disposable displays, yet are currently limited by photo-oxidative bleaching of the active materials. Here, renewable barrier films composed of cellulose and chitin are presented as an alternative to poly(ethylene terephthalate) (PET) for encapsulating ECDs. To assess barrier film effectiveness, lateral ECDs composed of poly(3,4-propylenedioxythiophene-(CH 2 OEtHx) 2 ) (P(ProDOT)) active layers were constructed and encapsulated with a multilayer barrier consisting of chitin nanofibers and cellulose nanocrystals spray cast onto a cellulose acetate substrate (oxygen transmission rate (OTR) = 29 cm 3 m –2 day –1 ), a commercially available PET film (OTR = 8.5 cm 3 m –2 day –1 ), and a high-performance PET-Al 2 O 3 multilayer barrier film (OTR < 1 cm 3 m –2 day –1 ). The photodegradation of the P(ProDOT) active layer was determined by measuring the evolution of the colorimetric contrast (ΔE*) and switching speeds as a function of light exposure (100 mW cm –2 , AM 1.5 G light). Photodegradation was found to proceed at a similar rate for all encapsulated devices (roughly 10 times more slowly than unencapsulated devices), highlighting the opportunity for replacing petroleum packaging with bioderived barrier films. Analysis of the switching kinetics, the shifts in optical absorbance, and evidence of chemical degradation indicate that both photochemical breakdown of the electrolyte and cross-linking of the P(ProDOT) active material are key drivers for loss of device performance when oxygen flux to the active material is limited. Furthermore, pathways toward better understanding photodegradation are then proposed with sustainability in mind for future ECD design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving Conversion of Captured CO 2 on Mixed-Oxide Dual-Function Materials by Low-Concentration Metal Promotion

Reactive carbon capture (RCC) is a promising nascent approach to harness the untapped resource of waste CO 2 to produce fuels and platform chemicals. However, process economics relies on the design of dual-function materials (DFMs) that exhibit maximal conversion of captured CO 2 and high selectivity toward valuable carbon products (e.g., CO). Herein, we report the use of low-concentration (ca. 0.5 wt %) metal promotors (Pt and Au) to improve the conversion of captured CO 2 on a Zn-Al mixed-oxide DFM by >30%, while also more than doubling per-cycle CO yield due to enhanced retention of captured CO 2 and H 2 activation. In situ DRIFTS of bound CO 2 on the DFMs showed distinctions in surface carbonate formation for the Pt- and Au-modified materials that were correlated with product evolution during the reactive desorption step of RCC. Particularly, Pt afforded superior H 2 activation but formed irreversibly-bound bicarbonates, compromising overall productivity, while the Na/Au/ZA DFM predominantly adsorbed CO 2 on Na sites, resulting in polydentate carbonates that are retained until higher temperatures before conversion to CO. In conclusion, these results indicate that adding a low concentration of oxidation-resistant noble metals, especially Au, is an effective strategy for improving key performance metrics of Zn-Al mixed-oxide DFMs to further advance the development of scalable RCC technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Binder Effects on Processing, Mechanical Properties, and Performance of Thin Sulfide Solid‐State Electrolytes

All‐solid‐state batteries (ASSBs) offer enhanced safety and energy density compared to conventional lithium‐ion batteries by replacing flammable liquid electrolytes with solid‐state electrolytes (SSEs). Among SSEs, sulfide‐based electrolytes exhibit high ionic conductivity and mechanical deformability, making them promising candidates for next‐generation energy storage. However, their practical implementation is hindered by interfacial instability, mechanical brittleness, and challenges in fabricating ultrathin electrolyte membranes (<30 μm) with robust mechanical integrity. Here, this study systematically examines the influence of polymeric binders—polyisobutylene, hydrogenated nitrile butadiene rubber, and styrene–ethylene–butylene–styrene (SEBS)—on the structural, mechanical, and electrochemical performance of thin sulfide SSE membranes. Key findings reveal that SEBS enables the fabrication of ultrathin, uniform membranes, while binder elasticity significantly affects structural stability during cycling. Operando stack pressure measurements indicate that binder properties directly influence adhesion force for LPSCl particles, influencing their stabilizing cycling period. These results underscore the critical role of polymer binders beyond mechanical reinforcement, positioning them as essential design variables in sulfide SSE engineering. By linking binder chemistry to processability and electrochemical performance, this study provides insights into optimizing sulfide SSEs, advancing their commercial viability in ASSBs.

argyrodite sulfide electrolyte↗

Optimizing Hybrid-Phase IrO2 Catalysts with Ti for Enhanced Oxygen Evolution Reaction for Proton Exchange Membrane Water Electrolysis

To realize a sustainable energy transition, water electrolysis-particularly proton exchange membrane water electrolysis (PEMWE)-holds significant promise. However, practical deployment is hindered by the cost and instability of the anode catalyst, IrO2. Recent studies indicate that tuning the Ir-O bond distance, via doping or composite formation, is key to enhancing the oxygen evolution reaction (OER) performance of IrO2-based electrocatalysts. Herein, a hybrid-phase Ti-incorporated IrO2 electrocatalyst is developed, exhibiting outstanding OER activity (298.8 mV at 100 mA cm-2) and stability over 25 h. This improvement originates from asymmetric interatomic interactions introduced by Ti, as revealed by combined experimental X-ray analyses and theoretical modeling. Ti incorporation induces tensile strain along the z-axis in IrO2 motifs, effectively reducing the average Ir-O bond distance and thereby enhancing OER activity. In situ X-ray absorption spectroscopy further confirms that at 1.5 V (vs. RHE), the elongated Ir-O bond facilitates -OOH* intermediate formation while suppressing Ir dissolution, contributing to superior stability. These findings underscore the critical role of Ir-O bond engineering in balancing activity and durability, offering strategic insights for the rational design of high-performance OER catalysts for renewable energy technologies.

08 HYDROGEN↗

Techno-Economic Assessments of Second-Life Batteries for Electric Vehicle Charging Stations

When electric vehicle (EV) batteries degrade below a certain capacity, they may no longer be suitable for automotive use but can be repurposed as second-life batteries (SLBs) for other applications, such as EV charging stations. When integrated with photovoltaic (PV) systems, SLB can store surplus solar energy, reducing reliance on the grid and lowering operational costs. This paper presents a novel techno-economic assessment framework for deploying SLBs in combination with PV in grid-connected EV charging stations. The proposed framework integrates the value proposition, charging station operation, optimal dispatch strategies, battery degradation modeling, input data requirements, and detailed procedures for generating key economic performance metrics. Insightful analyses are performed to assess the performance of SLBs in comparison to new batteries across various cost scenarios. The results indicate that SLBs become financially attractive when their cost is 40% or lower than new batteries.

energy storage↗

Comparative life-cycle assessments and techno-economic analysis of renewable natural gas production pathways from biogas

Renewable natural gas (RNG) offers a promising pathway for decarbonizing hard-to-abate sectors. This study shows that, relative to conventional upgrading technologies (i.e., membrane separation and pressure swing adsorption), the catalytic methanation reaction (CMR) at water resource recovery facilities doubles RNG output. When consuming lowcarbon hydrogen, the CMR reduces operational energy use and global warming potential. Techno-economic analysis indicates that the CMR is not yet competitive but will become viable if hydrogen reaches $1/kg. Heat integration and hydrogen cost are key drivers of overall performance.

03 NATURAL GAS↗

Design and Technoeconomic Analysis of High-Temperature Particle Conveyance Components for a 100 MW e Concentrating Solar Power Plant

Levelized costs of electricity (LCOE) approaching the U.S. Department of Energy Solar Energy Technologies Office 2030 goal of 0.05 $/kWh may be achievable using Brayton power cycles that use supercritical CO2 as the working fluid and flowing solid particles with temperatures >700° C as the heat transfer media. The handling and conveyance of bulk solid particles at these temperatures in an insulated environment is a critical technical challenge that must be solved for this approach to be used. A design study was conducted at the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories in Albuquerque, NM, with the objective of identifying the technical readiness level, performance limits, capital and O&M costs, and expected thermal losses of particle handling and conveyance components in a particle-based CSP plant. Key findings indicated that chutes can be a low-cost option for particle handling but uncertainties in tower costs make it difficult to know whether they can be cost effective in areas above the receiver if tower heights must then be increased. Skips and high temperature particle conveyance technology are available for moving particles up to 640° C. This limits the use of mechanical conveyance above the heat exchanger and suggests vertical integration of the hot storage bin and heat exchanger to facilitate direct gravity fed handling of particles.

14 SOLAR ENERGY↗

Benefits Of Automated Construction And Energy Efficiency Measures In Modular Homes

This article builds on and adds to a Buildings XV publication that introduced the Transformative Efficiency and Automation in Modular Homes (TEAMH) project. The TEAMH project sought to develop a scalable solution for producing modular homes with 20-50% energy savings and similar cost relative to site-fabricated single-family home construction. A key aspect of the project was assessing the potential for labor cost reductions through automation-assisted construction using light gauge steel (LGS). To quantify the advantages of this approach, side-by-side comparisons were made between traditional wood-framed construction and automation-assisted LGS construction. This demonstration involved constructing one wood-framed wall and several LGS test walls, accompanied by a time-and-motion study. The results indicated that automation assistance could decrease construction time and associated labor costs by as much as 46%. High-performance envelope technologies for exterior insulation and air sealing were evaluated to compare modular homes with site-built homes that meet the International Energy Conservation Code (IECC). A key technology considered was vacuum insulation panels (VIPs) with fiberglass cores. Guarded hot box testing of multiple full-scale wall assemblies containing different combinations of exterior continuous insulation systems containing phenolic foam and VIPs. Testing on various full-scale wall assemblies revealed that, with LGS construction, cavity insulation had minimal impact on exterior wall performance. Omitting cavity insulation can reduce labor and material costs while streamlining manufacturing, as its installation is labor-intensive and not easily automated due to the need for precise placement around wiring and other internal components. Guarded hot box tests of multiple LGS test walls with foam and VIP-based exterior insulation systems achieved R-values of up to 31 hr-ft2-°F/Btu. Finally, building energy modeling of multiple modular home designs indicated that the upgraded envelope assemblies can yield heating energy savings of up to 50% and cooling energy savings of up to 30% compared to IECC 2018 standards.

Shrestha, Som [ORNL] (ORCID:0000000183993797)↗

Modular Hydronic Room Conditioning System (CRADA NFE-24-10120 Final Report)

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin-tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular Hydronic Room Conditioning System

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methyl formate oxidation kinetics up to 100 atm

Methyl formate (MF, CH3OCHO), the simplest ester, is a representative oxygenated fuel with high oxygen content, and low sooting tendency. However, its oxidation behavior under high-pressure and intermediate-temperature conditions remains insufficiently understood, especially where low-temperature peroxy radical chemistry, methanol chemistry, and pressure-dependent reaction pathways play a critical role. In this study, MF oxidation experiments were conducted in the Princeton supercritical-pressure jet-stirred reactor (SP-JSR) at 20 and 100 atm over the temperature range of 400–950 K under both fuel-lean and fuel-rich conditions. Based on the experimental results, an updated HP-Mech was developed by incorporating previous MF sub-mechanisms, expanded low-temperature peroxy pathways, and evaluated pressure-dependent decomposition kinetics. The newly updated HP-Mech shows greatly improved performance in predicting the onset temperature, the key intermediate species fractions, methanol formation, and the progression of MF oxidation across all the experimental conditions. Path flux analysis indicates that MF consumption at the onset stage is dominated by H-abstraction at the methyl site, forming CH2OCHO radicals that lead to the formation and isomerization of O2CH2OCHO, driving low-temperature chain propagation. Moreover, H-abstraction at the formate site forms CH3OCO radicals that preferentially decompose to CH3, initiating the methanol formation pathway linked to CH3O2 and HO2 chemistry. At the same time, HO2 formation is strongly coupled to MF oxidation through multiple MF-derived radical pathways. HCO originates from MF oxidation and acts as a key coupling species linking fuel consumption to HO2 buildup, especially under high-pressure and intermediate-temperature conditions. In addition to this dominant channel, supplementary HO2 formation pathways involving CH3, CH3O, CH2OH, and CH3O2 reacting with O2 further connect methanol chemistry and oxygenated radical chemistry to the HO2 pool, indicating the central role of HO2 in governing MF oxidation. Sensitivity analysis identifies MF with OH/HO2/CH3O2 reactions and the HO2/H2O2/OH sequence as the key factors controlling reactivity in the high-pressure and intermediate-temperature regime. MF directly reacts with OH/HO2/CH3O2 to consume the fuel and produce reactive radicals like CH2OCHO and CH3OCO that undergo subsequent oxidation pathways. Moreover, HO2 recombination suppresses oxidation at lower temperatures, while thermal decomposition of H2O2 accelerates OH production and promotes fuel consumption as temperature increases. The direct formation of active OH from HO2 radicals further completes the mechanism, improving its prediction especially during the oxidation onset stage.

Low-temperature Chemistry↗

Towards operational atmospheric correction of airborne hyperspectral imaging spectroscopy: Algorithm evaluation, key parameter analysis, and machine learning emulators

Atmospheric correction of airborne hyperspectral imaging spectroscopy (AHIS) to obtain high-quality surface reflectance is the prerequisite for remote sensing applications. Over the last decades, different atmospheric correction methods have been developed based on radiative transfer models (RTMs), however, the relative performances of different algorithms are unclear. Automated operational atmospheric correction methods to process large-volume AHIS data in a high-accurate and high-throughput manner are still lacking. Therefore, this study proposed an operational atmospheric correction pipeline for deriving surface reflectance from AHIS data. To ensure the accuracy and efficiency of the pipeline, we focused on three specific aspects: (1) selecting a suitable RTM for the development of atmospheric lookup tables (LUTs) by comparing the commercial MODerate resolution atmospheric TRANsmission (MODTRAN) and open-sourced Library for Radiative TRANsfer (LibRadTRAN) models, where the widely-used software, Atmospheric/Topographic Correction for Airborne Imagery (ATCOR), was used as benchmarks; (2) identifying key atmospheric correction parameters and determining suitable sources for parameter retrievals including AHIS, Moderate Resolution Imaging Spectroradiometer (MODIS), and AErosol RObotic NETwork (AERONET); and (3) testing the performance of using machine learning emulators to speed up the RTM-based atmospheric correction. Results indicate that (1) atmospheric correction based on MODTRAN LUTs can produce surface reflectance accurately with mean absolute errors < 0.05 and cosine similarities > 0.98 compared to field measurements, which is comparable to the software ATCOR and slightly outperforms the LibRadTRAN LUTs; (2) sobol global sensitivity analysis demonstrates that in the atmospheric correction, visibility and water vapor are two key parameters that can be accurately derived from AHIS in contrast to MODIS or AERONET data; and (3) Random Forest emulators can produce accurate estimations of surface reflectance with mean absolute errors < 0.03 and cosine similarities > 0.98 for higher processing efficiency and determine a suitable set of wavelengths for retrieving atmospheric visibility and water vapor. In conclusion, the proposed atmospheric correction pipeline also improved the four-stream radiative transfer theory for airborne applications by considering adjacent effects from airborne surrounding pixels and can also be applied for atmospheric correction of hyperspectral data from spaceborne missions.

47 OTHER INSTRUMENTATION↗

Trustworthiness and Trust: Identifying Factors that Drive Successful Human-AI Interaction in Nuclear Power Plant Applications

Emerging technologies such as artificial intelligence (AI) and machine learning (ML) are rapidly evolving and considered a promising tool for efficient and continued safe operations of the U.S. nuclear power plants (NPPs). Emerging AI techniques like large language models (LLMs) are one such technology that may support personnel at existing NPPs perform work more efficiently. For example, operators may query the current operational status of a power plant via a chat interface leveraging LLMs to access plant-related information in an interactive manner rather than manually collecting various sensor data for tasks such as surveillances or completing work orders. This is a fundamental shift in the way operators currently perform their tasks today. The literature of human-automation interaction indicates that trust is a crucial factor that drives successful interaction between a human operator and an automated system, like an AI-infused NPP application. This work presents the results of a literature review on key factors that relate to trust in AI/LLM technologies for NPP applications. The relevant literature of human factors and cognitive engineering has identified various factors related to trust including trustworthiness, performance characteristics, operator skill and perceived risk. This preliminary literature review will guide development and evaluation of models involving the identified factors influencing trust in AI and develop a framework for human-centered design for interface between humans and AI. By addressing trust, this work supports developing a technical basis for designing key characteristics of AI/LLM to support calibrated trust, which will ultimately support wide-scale adoption of AI/LLM technologies, as well as ensure safe, effective, and reliable use.

99 - GENERAL AND MISCELLANEOUS↗

Particle-based high-temperature thermochemical energy storage reactors

Solar and other renewable energy driven gas-solid thermochemical energy storage (TCES) technology is a promising solution for the next generation energy storage systems due to its high operating temperature, efficient energy conversion, ultra-long storage duration, and potential high energy density. Experimental and theoretical studies suggest that the respective gravimetric and volumetric TCES energy storage densities vary from 200 to 3000 kJ kg –1 and 1–3 GJ m –3 . Solar radiation or heat generated from electric furnaces powered by renewable electricity can be stored in the form of chemical energy through endothermic reactions, while the stored chemical energy can be converted to thermal energy via an exothermic reaction when needed. The design of highly effective reactors requires a deep understanding of materials, thermodynamics, chemical kinetics, and transport phenomena. At time of writing, TCES reactors are yet to be deployed at commercially relevant scales, leaving a substantial gap between development efforts and commercial feasibility. Therefore, this review aims to examine the state-of-the-art design and performance of particle-based TCES reactors with different reactive materials. Fundamentals related to TCES reactive materials, reaction conditions, thermodynamics and kinetics, and transport phenomena are reviewed in detail to provide a comprehensive understanding of the reactor design and operation. Five major types of TCES reactors have been comprehensively reviewed and compared, including fixed, moving, rotary, fluidized, and entrained bed reactors. Most reported prototype reactors in the literature operate at lab scale with thermal inputs below 40 kW, and scaled TCES reactors (e.g., at megawatt level) are yet to be demonstrated. The nominal reactor operating temperatures range from 300 to 1500 °C, depending on the selected chemistry, reactive material, and heat sources. To evaluate their designs, the reactors are assessed in aspects of performance, cost, and durability. Discrepancies in performance indicators of energy storage density, extent of reaction, and various energy efficiencies are highlighted. The scale-up of reactors and power block integration, which hold the key to the successful commercialization of TCES systems, are critically analyzed. Furthermore, advanced materials (both reactive materials and ceramic reactor housing materials), effective particle flow control, advanced modeling tools, and novel system design may bring significant improvement to the energy efficiency, storage density and cost competitiveness of particle-based TCES reactors.

25 ENERGY STORAGE↗