Search NASA⌕ Search

SEARCH · Search NASA

Results for “LENS DESIGN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Design of a Multi-Color Plenoptic Camera for Snapshot Hyperspectral Imaging

The design of a custom camera lens including: a two-lens optical system, filter array, and iris has been developed enabling a greyscale plenoptic camera to acquire full field-of-view, 2D, instantaneous hyperspectral measurements. This work focuses on the use of 7 discrete color filters and their effect on the image quality. It was determined that the placement of the filters inside the aperture plane of the camera was paramount to mitigating image artifacts. In addition, design rules were developed such that the optimal optical parameters (image distance, working distance, and focal length) can be easily determined from a few charts.

Fahringer, Timothy W., Jr.↗

A layout designer's data projection reticle

The designer's projection reticle is a modified surplus weapons sighting device consisting of a 3.5 cm diameter, 8.9 focal length coated objective lens. It is placed 1.5 cm in front of a clear flat glass plate on which the aluminized reflective pattern has been deposited. Reflected light passes through the objective lens, off the front surface of the coating, and off the rear coated surface of the objective lens. Several reticle patterns have been designed and tested, and other patterns are in the planning stage. The device may be used for a variety of applications including determining the optimum locations on a cockpit panel for luminous warning indicators requiring rapid manual responses.

Haines, R. F.↗

Endoscopic measurements using a panoramic annular lens

The objective of this project was to design, build, demonstrate, and deliver a prototype system for making measurements within cavities. The system was to utilize structured lighting as the means for making measurements and was to rely on a stationary probe, equipped with a unique panoramic annular lens, to capture a cylindrical view of the illuminated cavity. Panoramic images, acquired with a digitizing camera and stored in a desk top computer, were to be linearized and analyzed by mouse-driven interactive software.

Gilbert, John A.↗

Can salt on an optical rain gauge lens affect performance?

The optical rain gauge (ORG) by ScTI is designed to be tolerant to reduction of infrared beam intensity due to a dirty lens. Recently there is interest in long term use of optical gauges onboard buoys at sea. Because of logistics, these systems are serviced infrequently, i.e., every several months. Due to the proximity of the gauges to the sea surface, salt can be expected to be deposited on the lens. To obtain an indication of the potential for dirty lens to affect the ORG calibration, two simple experiments were conducted. In the control experiment, a sample ORG was compared to three other ORG's during natural rain events. Next a translucent mask was placed on the transmitter lens of the sample ORG and again data were collected under natural rain conditions. The mask reduced the gain of the perturbed ORG by about 30%. The perturbed ORG operated rather well in that the mask only causes a change in the gain and does not cause data drop out at low rain rates. However, the reduced gain would seriously impact an assessment of rain statistics.

Bliven, Larry F.↗

Feasibility test of a solid state spin-scan photo-imaging system

The feasibility of using a solid-state photo-imaging system to obtain resolution imagery from a Pioneer-type spinning spacecraft in future exploratory missions to the outer planets is discussed. Evaluation of the photo-imaging system performance, based on electrical video signal analysis recorded on magnetic tape, shows that the signal-to-noise (S/N) ratios obtained at low spatial frequencies exceed the anticipated performance and that measured modulation transfer functions exhibited some degradation in comparison with the estimated values, primarily owing to the difficulty in obtaining a precise focus of the optical system in the laboratory with the test patterns in close proximity to the objective lens. A preliminary flight model design of the photo-imaging system is developed based on the use of currently available phototransistor arrays. Image quality estimates that will be obtained are presented in terms of S/N ratios and spatial resolution for the various planets and satellites. Parametric design tradeoffs are also defined.

Laverty, N. P.↗

Coronal observations from the SMM satellite

The scientific purpose, coronal observations, and the instrument design and control of the Coronagraph/Polarimeter aboard the Solar Maximum Mission (SMM) satellite are discussed. The instruments were made with an optical design using an achromatic objective lens providing a 10 arcsec resolution in imaging and an SEC vidicon detector allowing integration on the low light levels of the corona. The computer control assures flexibility in the observing program to optimize observations of changing solar phenomena and allows rapid response to SMM or ground-commanded solar flare alerts.

Csoeke-Poeckh, A.↗

Thermal Lens Measurement in Diode-Pumped Nd:YAG Zig-Zag Slab

A major advantage that solid state zig-zag slab lasers have over conventional rod-based designs is that a much weaker thermal lens is produced in the slab when side-pumped with Quasi-CW laser diode arrays, particularly if the pump radiation is kept well away from the Brewster-cut ends. This paper reports on a rather strong thermal lens produced when diode pump radiation is collimated into a narrow portion of the zig-zag slab. The collimation of multi-bar pump packages to increase brightness and improve overlap is a direct consequence of designs which seek to maximize performance and efficiency. Our slab design employed a 8.1 cm x 2.5 mm x 5 mm slab with opposing Brewster end faces. It was pumped through the 2.5 mm direction by seven laser diode array packages, each housing four 6OW diode bars, 1 cm in width. The pump face, anti-reflection (AR) coated at 809 nm, was 6.8 cm in width and the 8.1 cm opposing side, high-reflection (HR) coated at 809 nm, reflected the unabsorbed pump beam for a second pass through the slab.

Smoak, M. C.↗

A SEP Mission to Jupiter Using the Stretched Lens Array

As space exploration continues to be a primary focus of NASA, solar electric propulsion (SEP) becomes a forerunner in the mode of transportation to reach other planets in our solar system. Several critical issues emerge as potential barriers to this approach such as reducing solar array radiation damage, operating the array at high voltage (>300 V) for extended times for Hall or ion thrusters, and designing an array that will be resistant to micrometeoroid impacts and the differing environmental conditions as the vehicle travels further into space. It is also of great importance to produce an array that is light weight to preserve payload mass fraction and to do this at a cost that is lower than today's arrays. This paper will describe progress on an array that meets all these requirements and will detail its use in a solar electric mission to Jupiter. From 1998-2001, NASA flew the Deep Space 1 mission that validated the use of ion propulsion for extended space missions. This highly successful two-year mission also used a novel SCARLET solar array that concentrated sunlight eight-fold onto small area solar cells. This array performed flawlessly and within 2% of its projected performance over the entire mission. That design has evolved into the Stretched Lens Array (SLA) shown in figure 1. The primary difference between SCARLET and the SLA is that no additional glass cover is used over the silicone lens. This has led to significant mass, cost and complexity reductions. The module shown in figure 1 is the latest version of the design. This design leads to a specific power exceeding 300 W/kg at voltages exceeding 300 V. In addition, this module has been tested to voltages over 1000 V while under hypervelocity particle impact in a plasma environment with no arcing. Furthermore array segments are under test for corona breakdown that can become a critical issue for long term, high voltage missions.

Brandhorst, Henry W.↗

Miniature Optical Wide-Angle-Lens Startracker (Mini-OWLS)

This paper provides a brief overview of the design considerations and the current status of the Miniature Optical Wide-Angle Lens Startracker Program. Mini-OWLS offers a revolutionary alternative to the conventional startracker. It is a small, lightweight, low cost, high performance startracker that can be used in a variety of applications including calibration and alignment of Inertial Measurement Units (IMU's) Mini-OWLS makes use of a strap down design incorporating Holographic Optical Elements (HOES) in place of conventional optics. HOES can be multiplexed so that the same aperture can be used for multiple separate optical paths looking in several directions simultaneously without startracker rotation. Additionally, separate Schmidt corrector plates are not required to compensate for spherical aberration. The optical assembly, or what would normally be considered as the telescope, is less than 20 cc in volume, weighs less than 55 grams, and contains the equivalent of three individual telescopes. Each one has a 4 deg Field of View (FOV) with a field of regard of 48 square degrees. Mini-OWLS has a bandwidth of approximately 300 nm in or near the visible wavelength. The projected resolution of the startracker is 5 to 10 arcseconds, depending on the centroiding algorithm used. The Mini-OWLS program was initiated last year and represents a miniaturized version of a similar design for aeronautical applications. The contract is managed by Wright Laboratory, Air Force Systems Command, Wright-Patterson AFB, Ohio, with funding from the Strategic Defense Initiative Organization through Eglin AFB. The initial phase of the program is to build and test a development unit. The second phase is to integrate the startracker with the Charles Stark Draper Laboratory Micromechanical Inertial Guidance System (MIGS) and the Signal Processing Packaging Design (SPPD) being developed by Texas Instruments. The preliminary design review was conducted in November 1991. Three-axes prototype telescope assemblies have been built and design evaluation tests initiated.

Miller, Rick↗

Acoustic lens is gas-filled

Fluorocarbon gas contained by plastic membrane is effective lens for sound waves. In tests, lens substantially improved accuracy of sound "maps" of turbulent airflow. It could also be used to record sound intensity patterns in design of speakers, lecture halls, and auditoriums. Lens is fabricated by clamping together two membranes of thin plastic and filling enclosed space with fluorocarbon gas. Since speed of sound in gas is considerably less than in air, lens refracts and focuses sound waves, analogous to focusing light by glass lens. Focal length is adjusted simply by changing gas pressure, which changes lens curvature.

Kendall, J. M., Jr.↗

Wavefront Sensing With Switched Lenses for Defocus Diversity

In an alternative hardware design for an apparatus used in image-based wavefront sensing, defocus diversity is introduced by means of fixed lenses that are mounted in a filter wheel (see figure) so that they can be alternately switched into a position in front of the focal plane of an electronic camera recording the image formed by the optical system under test. [The terms image-based, wavefront sensing, and defocus diversity are defined in the first of the three immediately preceding articles, Broadband Phase Retrieval for Image-Based Wavefront Sensing (GSC-14899-1).] Each lens in the filter wheel is designed so that the optical effect of placing it at the assigned position is equivalent to the optical effect of translating the camera a specified defocus distance along the optical axis. Heretofore, defocus diversity has been obtained by translating the imaging camera along the optical axis to various defocus positions. Because data must be taken at multiple, accurately measured defocus positions, it is necessary to mount the camera on a precise translation stage that must be calibrated for each defocus position and/or to use an optical encoder for measurement and feedback control of the defocus positions. Additional latency is introduced into the wavefront sensing process as the camera is translated to the various defocus positions. Moreover, if the optical system under test has a large focal length, the required defocus values are large, making it necessary to use a correspondingly bulky translation stage. By eliminating the need for translation of the camera, the alternative design simplifies and accelerates the wavefront-sensing process. This design is cost-effective in that the filterwheel/lens mechanism can be built from commercial catalog components. After initial calibration of the defocus value of each lens, a selected defocus value is introduced by simply rotating the filter wheel to place the corresponding lens in front of the camera. The rotation of the wheel can be automated by use of a motor drive, and further calibration is not necessary. Because a camera-translation stage is no longer needed, the size of the overall apparatus can be correspondingly reduced.

Dean, Bruce H.↗

Endoscopic inspection using a panoramic annular lens

The objective of this one year study was to design, build, and demonstrate a prototype system for cavity inspection. A cylindrical view of the cavity interior was captured in real time through a compound lens system consisting of a unique panoramic annular lens and a collector lens. Images, acquired with a digitizing camera and stored in a desktop computer, were manipulated using image processing software to aid in visual inspection and qualitative analysis. A detailed description of the lens and its applications is given.

Gilbert, John A.↗

Instrument Performance of GISMO, a 2 Millimeter TES Bolometer Camera used at the IRAM 30 m Telescope

In November of 2007 we demonstrated a monolithic Backshort-Under-Grid (BUG) 8x16 array in the field using our 2 mm wavelength imager GISMO (Goddard IRAM Superconducting 2 Millimeter Observer) at the IRAM 30 m telescope in Spain for astronomical observations. The 2 mm spectral range provides a unique terrestrial window enabling ground-based observations of the earliest active dusty galaxies in the universe and thereby allowing a better constraint on the star formation rate in these objects. The optical design incorporates a 100 mm diameter silicon lens cooled to 4 K, which provides the required fast beam yielding 0.9 lambda/D pixels. With this spatial sampling, GISMO will be very efficient at detecting sources serendipitously in large sky surveys, while the capability for diffraction limited imaging is preserved. The camera provides significantly greater detection sensitivity and mapping speed at this wavelength than has previously been possible. The instrument will fill in the spectral energy distribution of high redshift galaxies at the Rayleigh-Jeans part of the dust emission spectrum, even at the highest redshifts. Here1 will we present early results from our observing run with the first fielded BUG bolometer array. We have developed key technologies to enable highly versatile, kilopixel, infrared through millimeter wavelength bolometer arrays. The Backshort-Under-Grid (BUG) array consists of three components: 1) a transition-edge-sensor (TES) based bolometer array with background-limited sensitivity and high filling factor, 2) a quarter-wave reflective backshort grid providing high optical efficiency, and 3) a superconducting bump-bonded large format Superconducting Quantum Interference Device (SQUID) multiplexer readout. The array is described in more detail elsewhere (Allen et al., this conference). In November of 2007 we demonstrated a monolithic 8x 16 array with 2 mm-pitch detectors in the field using our 2 mm wavelength imager GISMO (Goddard IRAM Superconducting 2 Millimeter Observer) at the IRAM 30 m telescope in Spain for astronomical observations. The 2 mm spectral range provides a unique terrestrial window enabling ground-based observations of the earliest active dusty galaxies in the universe and thereby allowing a better constraint on the star formation rate in these objects. The optical design incorporates a 100 mm diameter silicon lens cooled to 4 K, which provides the required fast beam yielding 0.9 lambda1D pixels. With this spatial sampling, GISMO will be very efficient at detecting sources serendipitously in large sky surveys, while the capability for diffraction limited imaging is preserved. The camera provides significantly greater detection sensitivity and mapping speed at this wavelength than has previously been possible. The instrument will fill in the spectral energy distribution of high redshift galaxies at the Rayleigh-Jeans part of the dust emission spectrum, even at the highest redshifts. Here I will we present early results from our observing run with the first fielded BUG bolometer array.

Staguhn, Johannes↗

Design of An Improved Miniature Ion Neutral Mass Spectrometer for NASA Applications

The ion optics of NASA's Ion Neutral Mass Spectrometer (INMS) sensor was simulated with three dimensional models of the open source, the quadrupole deflector, the exit lens system and the quadrupole mass analyzer to design more compact models with lower weight. Comparison of calculated transmission with experimental results shows good agreement. Transmission analyses with varying geometrical parameters and voltages throw light on possible ways of reducing the size of the sensor. Trajectories of ions of mass 1-99 amu were simulated to analyze and optimize transmission. Analysis of open source transmission with varying angle of attack shows that the angular acceptance can be considerably increased by programming the voltages on the ion trap/ collimator. Analysis of transmission sensitivity to voltages and misalignments of the quadrupole deflector rods indicate that increased transmission is possible with a geometrically asymmetrical deflector and a deflector can be designed with much lower sensitivities of transmission. Bringing the disks closer together can decrease the size of the quadrupole deflector and also increase transmission. The exit lens system can be redesigned to be smaller by eliminating at least one electrode entirely without loss of transmission. Ceramic materials were investigated to find suitable candidates for use in the construction of lighter weight mass spectrometer. A high-sensitivity, high-resolution portable gas chromatograph mass spectrometer with a mass range of 2-700 amu has been built and will be commercialized in Phase 3.

Swaminathan, Viji K.↗

Gas permeation measurements on small polymer specimens

Mass spectrometry was used to measure oxygen and nitrogen permeabilities while polarography was used to measure oxygen permeabilities for several contact lens materials. Applicable sample holders were designed and fabricated to accommodate curved and flat specimens. A prepared standard was used to calibrate the mass spectrometric analyses. The oxygen permeability values determined by mass spectrometry were significantly greater than those determined by polarography. This was attributed to the phase boundary phenomena and the limiting oxygen permeance of water inherent in the polarographic technique. Polarographic values determined were in good agreement with proprietary values obtained by polarography, with the exception of one material.

Burns, Karen S.↗

An intensified CCD detector using the phosphor TPB

The Research Amplifying Imaging Detector consists of a microchannel plate image intensifier with a thin coating (3500-10,000 A) of the phosphor tetraphenyl-butadiene (TPB) on the entrance window to convert EUV radiation to visible, and coupled via a lens to a CCD detector. This design allows great flexibility in selecting the pixel size and field of view, with a simple mechanical design. The phosphor appears to be quite rugged, with no degradation having appeared during several months of testing both in and out of vacuum. Tests have been made at visible and EUV (304 A) wavelengths of the following performance aspects: EUV spectral sensitivity, spatial resolution (both of components and of the system as a whole), noise, linearity, and dynamic range. An improved detector for the Coronal Diagnostic Spectrometer experiment on the Solar Heliospheric Observatory satellite is being presently designed.

Thompson, William T.↗