Search NASA⌕ Search

SEARCH · Search NASA

Results for “LHD DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Spatiotemporal dynamics and transport reduction in helical magnetic configuration

Effects of multihelicity confinement magnetic fields on turbulent transport and zonal flows are investigated by means of spatiotemporal analysis of gyrokinetic Vlasov simulation results for the ion temperature gradient turbulence, where the standard and the inward-shifted configurations of the Large Helical Device are considered. The analysis of simulation results demonstrates that fluctuations of electrostatic potential for zonal flows exhibit spatiotemporal chaos in both configurations. However, the intensity of chaos found is considerably decreased in the inward-shifted configuration consistent with improved confinement. Enhanced zonal flow generation in the inward shifted case is accompanied by transport reduction which may be a direct consequence of chaos suppression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characteristics of magnetic island formation due to resistive interchange instability in helical plasma

Focusing attention on the magnetic island formation, we investigate the characteristics of the resistive interchange magnetohydrodynamics instabilities, which would limit a high beta operational regime in helical type fusion reactors. An introduction of a new index, i.e., the ratio of the magnetic fluctuation level to the radial displacement, enables us to make a systematic analysis on the magnetic island formation in the large helical device-like plasmas during the linear growth phase; (i) the interchange instability with the second largest growth rate makes the magnetic island larger than that with the largest growth rate when the amplitude of the radial displacement in both cases is almost the same as each other; (ii) applied to a typical tearing instability, the index is smaller than that for the interchange instability with the second largest growth rate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast excitation of geodesic acoustic mode by energetic particle beams

A new mechanism for geodesic acoustic mode (GAM) excitation by a not fully slowed down energetic particle (EP) beam is analyzed to explain experimental observations in Large Helical Device. It is shown that the positive velocity space gradient near the lower-energy end of the EP distribution function can strongly drive the GAM unstable. The new features of this EP-induced GAM (EGAM) are: (1) no instability threshold in the pitch angle; (2) the EGAM frequency can be higher than the local GAM frequency; and (3) the instability growth rate is much larger than that driven by a fully slowed down EP beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coaxial pellets for metallic impurity injection on the large helical device

Two coaxial pellets with tungsten inserted into graphite carbon and polyethylene (PE) tubes are compared for tungsten spectroscopic study in the Large Helical Device. The tungsten pellet with carbon tube causes plasma collapse, while that with PE tube smoothly ablates without collapse. The deposition profile of the pellets is analyzed with a help of pellet ablation spectroscopy. It is found that the tungsten pellet with carbon tube can significantly penetrate into the core plasma and leads to the plasma collapse. A tungsten spectrum with radial profile is successfully observed when the tungsten pellet with PE tube is used.

36 MATERIALS SCIENCE↗

Development of two color laser diagnostics for the ITER poloidal polarimeter

Two color laser diagnostics using terahertz laser sources are under development for a high performance operation of the Large Helical Device and for future fusion devices such as ITER. So far, we have achieved high power laser oscillation lines simultaneously oscillating at 57.2 and 47.7 {mu}m by using a twin optically pumped CH{sub 3}OD laser, and confirmed the original function, compensation of mechanical vibration, of the two color laser interferometer. In this article, application of the two color laser diagnostics to the ITER poloidal polarimeter and recent hardware developments will be described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of electron cyclotron emission imaging system on Large Helical Device

A combined system of microwave imaging reflectometry and electron cyclotron emission (ECE) imaging has been developed for the Large Helical Device. This system includes a wide-band two-dimensional horn-antenna mixer array (HMA). The HMA consists of horn antennas, waveguides, mixers, and intermediate frequency circuits. The frequency response of the HMA is between 50 and 110 GHz. The ECE signal is selected using a 95 GHz local oscillator and a 93 GHz high-pass filter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress in development of the neutron profile monitor for the large helical device

The neutron profile monitor stably operated at a high-count-rate for deuterium operations in the Large Helical Device has been developed to enhance the research on the fast-ion confinement. It is composed of a multichannel collimator, scintillation-detectors, and a field programmable gate array circuit. The entire neutron detector system was tested using an accelerator-based neutron generator. This system stably acquires the pulse data without any data loss at high-count-rate conditions up to 8 × 10{sup 5} counts per second.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvement of accelerator of negative ion source on the Large Helical Device

To improve the performance of negative-ion based neutral beam injection on the Large Helical Device, the accelerator was modified on the basis of numerical investigations. A field limiting ring was installed on the upper side of a grounded grid (GG) support and a multi-slot GG was adopted instead of a multi-aperture GG. As a result, the voltage holding capability is improved and the heat load on the GG decreases by 40%. In addition, the arc efficiency is improved significantly only by replacing the GG.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of fast steering mirror control system for plasma heating and diagnostics

A control system for a fast steering mirror has been newly developed for the electron cyclotron heating (ECH) launchers in the large helical device. This system enables two-dimensional scan during a plasma discharge and provides a simple feedback control function. A board mounted with a field programmable gate array chip has been designed to realize feedback control of the ECH beam position to maintain higher electron temperature by ECH. The heating position is determined by a plasma diagnostic signal related to the electron temperature such as electron cyclotron emission and Thomson scattering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of high-energy neutral particles on extreme ultraviolet spectroscopy in large helical device

Spectra measured by an extreme ultraviolet (EUV) spectrometer frequently suffer large spike noise when Large Helical Device is operated in low-density range ({<=}3 Multiplication-Sign 10{sup 13} cm{sup -3}) with neutral beam injection (NBI). The spike noise completely disappears in electron cyclotron heating discharges. In order to examine the effect of NBI, a carbon filter with thickness of 150 nm was installed in the EUV spectrometer. As a result, the spike noise was reduced by an order of magnitude. It is experimentally verified that the spike noise is caused by escaping high-energy neutral particles resulting from the circulating high-energy hydrogen ions borne from NBI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of polarizers for a mega-watt long-pulse millimeter-wave transmission line on the large helical device

The polarizer is one of the critical components in a high-power millimeter-wave transmission line. It requires full and highly efficient coverage of any polarization states, high-power tolerance, and low-loss feature. Polarizers with rounded shape at the edge of the periodic groove surface are designed and fabricated by the machining process for a mega-watt long-pulse millimeter-wave transmission line of the electron cyclotron resonance heating system in the large helical device. The groove shape of λ/8- and λ/4-type polarizers for an 82.7 GHz transmission line is optimally designed in an integral method developed in the vector theories of diffraction gratings so that the efficiency to realize any polarization state can be maximized. The dependence of the polarization states on the combination of the two polarizer rotation angles (Φ{sub λ/8}, Φ{sub λ/4}) is examined experimentally in a low-power test with the newly developed polarization monitor. The results show that the measured polarization characteristics are in good agreement with the calculated ones.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A close-coupling multi-antenna type radio frequency driven ion source

A newly close coupling multi-antenna type radio frequency driven ion source is tested for the purpose of essentially improving plasma coupling on the basis of our old type ion source, which reuses a NNBI (negative ion source for neutral beam injection) ion source used in 1/5th scale of the Large Helical Device NNBI. The ion source and the antenna structure are described, and the efficient plasma production in terms of the positive ion saturation current (the current density) is studied. The source is made of a metal-walled plasma chamber which is desirable from the point of view of the structural toughness for fusion and industrial application, etc. At around 160 kW of rf input power, the ion saturation current density successfully reaches the 5 A/cm{sup 2} level with a gas pressure of 0.6-2 Pa in hydrogen for 10 ms pulse duration. The rf power efficiency of the plasma production with a close coupling configuration of the antenna is improved substantially compared to that with the previous antenna unit in the old type ion source. The power efficiency is assessed as competing with that of other types of sources.

43 PARTICLE ACCELERATORS↗

Electron cyclotron beam measurement system in the Large Helical Device

In order to evaluate the electron cyclotron (EC) heating power inside the Large Helical Device vacuum vessel and to investigate the physics of the interaction between the EC beam and the plasma, a direct measurement system for the EC beam transmitted through the plasma column was developed. The system consists of an EC beam target plate, which is made of isotropic graphite and faces against the EC beam through the plasma, and an IR camera for measuring the target plate temperature increase by the transmitted EC beam. This system is applicable to the high magnetic field (up to 2.75 T) and plasma density (up to 0.8 × 10{sup 19} m{sup −3}). This system successfully evaluated the transmitted EC beam profile and the refraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Equilibrium and stability in a heliotron with anisotropic hot particle slowing-down distribution

The equilibrium and linear fluid Magnetohydrodynamic (MHD) stability in an inward-shifted large helical device heliotron configuration are investigated with the 3D ANIMEC and TERPSICHORE codes, respectively. A modified slowing-down distribution function is invoked to study anisotropic pressure conditions. An appropriate choice of coefficients and exponents allows the simulation of neutral beam injection in which the angle of injection is varied from parallel to perpendicular. The fluid stability analysis concentrates on the application of the Johnson-Kulsrud-Weimer energy principle. The growth rates are maximum at <{beta}>{approx}2%, decrease significantly at <{beta}>{approx}4.5%, do not vary significantly with variations of the injection angle and are similar to those predicted with a bi-Maxwellian hot particle distribution function model. Stability is predicted at <{beta}>{approx}2.5% with a sufficiently peaked energetic particle pressure profile. Electrostatic potential forms from the MHD instability necessary for guiding centre orbit following are calculated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linear properties of energetic particle driven geodesic acoustic mode

Linear properties of energetic particle driven geodesic acoustic mode (EGAM) in the large helical device plasmas are investigated using a hybrid simulation code for a magnetohydrodynamics fluid interacting with energetic particles. It is found that the EGAM is a global mode with the spatially uniform oscillation frequency despite the spatial variation of the local geodesic acoustic mode frequency. The poloidal mode numbers of poloidal velocity fluctuation, plasma density fluctuation, and magnetic fluctuation are m = 0, 1, and 2, respectively. Oscillation frequency, linear growth rate, and spatial width of EGAM are compared for different physics conditions. The EGAM frequency is proportional to the square root of the plasma temperature. The frequency is lower for higher energetic particle {beta} value. The mode spatial width is larger for larger spatial width of the energetic particle distribution and for the reversed shear safety-factor profile than the normal shear profile. It is also found that the EGAM propagates radially outward in the linearly growing phase, and the propagation speed is slower for the spatially broadened modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-dimensional wave-number spectral analysis techniques for phase contrast imaging turbulence imaging data on large helical device

An analysis method for unfolding the spatially resolved wave-number spectrum and phase velocity from the 2D CO{sub 2} laser phase contrast imaging system on the large helical device is described. This is based on the magnetic shear technique which identifies propagation direction from 2D spatial Fourier analysis of images detected by a 6 × 8 detector array. Because the strongest modes have wave-number at the lower end of the instrumental k range, high resolution spectral techniques are necessary to clearly resolve the propagation direction and hence the spatial distribution of fluctuations along the probing laser beam. Multiple-spatial point cross-correlation averaging is applied before calculating the spatial power spectrum. Different methods are compared, and it is found that the maximum entropy method (MEM) gives best results. The possible generation of artifacts from the over-narrowing of spectra are investigated and found not to be a significant problem. The spatial resolution Δρ (normalized radius) around the peak wave-number, for conventional Fourier analysis, is ∼0.5, making physical interpretation difficult, while for MEM, Δρ ∼ 0.1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of steady-state operation using ion cyclotron heating in the Large Helical Device

Using a handshake shape (HAS) antenna phasing dipole for ion cyclotron heating (ICH), the heating efficiency was higher than that using a previous poloidal array antenna in the Large Helical Device. In order to sustain the dipole operation, real-time feedback for impedance matching and maintaining the same phase and power was adopted during long-pulse discharge. The HAS antenna was designed to reduce parasitic losses associated with energetic particle and radio-frequency (RF) sheath effects by field-aligned current concentration on the midplane. Local hot spots and the inhomogeneity of the diverter heat profile in the toroidal direction were reduced. The long-pulse discharge with an electron density (n{sub e0}) of 1 × 10{sup 19} m{sup −3}, center electron temperature (T{sub e0}) of 2.5 keV, a plasma duration time (t{sub d}) of 19 min, and RF heating power (P{sub RF}) of 1 MW was achieved by ICH and electron cyclotron heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and performance of a punch mechanism based pellet injector for alternative injection in the large helical device

A low speed single barrel pellet injector, using a mechanical punch device has been developed for alternative injection in the large helical device. A pellet is injected by the combined operation of a mechanical punch and a pneumatic propellant system. The pellet shape is cylindrical, 3 mm in diameter and 3 mm in length. Using this technique the speed of the pellet can be controlled flexibly in the range of 100-450 m/s, and a higher speed can be feasible for a higher gas pressure. The injector is equipped with a guide tube selector to direct the pellet to different injection locations. Pellets are exposed to several curved parts with the curvature radii R{sub c}= 0.8 and 0.3 m when they are transferred in guided tubes to the respective injection locations. Pellet speed variation with pressure at different pellet formation temperatures has been observed. Pellet intactness tests through these guide tubes show a variation in the intact speed limit over a range of pellet formation temperatures from 6.5 to 9.8 K. Pellet speed reduction of less than 6% has been observed after the pellet moves through the curved guide tubes.

42 ENGINEERING↗