Search NASA⌕ Search

SEARCH · Search NASA

Results for “LIGHTING EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The S π RIT time projection chamber

The SAMURAI Pion Reconstruction and Ion-Tracker Time Projection Chamber (SπRIT TPC) was designed to enable measurements of heavy ion collisions with the SAMURAI spectrometer at the RIKEN Radioactive Isotope Beam Factory and provide constraints on the Equation of State of neutron-rich nuclear matter. The SπRIT TPC has a 50.5 cm drift length and an 86.4 cm × 134.4 cm 2 pad plane with 12,096 pads that are equipped with the Generic Electronics for TPCs. The SπRIT TPC allows excellent reconstruction of particles and provides isotopic resolution for pions and other light charged particles across a wide range of energy losses and momenta. Here, details of the SπRIT TPC are presented, along with discussion of the TPC performance based on cosmic ray and charged particles emitted in heavy ion collisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

November 2019 Initial Deployment of LiDAR in the H-Canyon Exhaust Tunnel

The H-Canyon Exhaust Tunnel (CAEX) structure is periodically inspected under the Structural Integrity Program using camera equipped crawlers or poles to remotely perform visual inspections. To explore the use of enhanced inspection methods a “Proof of Concept” using the Light Detection and Ranging (LiDAR) technology was performed over a 2-day period in November 2019. The purpose of the “Proof of Concept” deployment was to confirm whether a commercially available LiDAR unit could successfully operate and remotely transmit data from the tunnel CAEX environment and whether the data would provide quantitative information to establish baseline measurements. The LiDAR performance requirement was a measurement accuracy of ± 0.25-inches over a 30-foot distance. This report documents the work activities leading to the deployment, the deployment and processing of data, lessons learned from the deployment and the post data processing methods that will be applied to future deployments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Noble Liquid Test Facility at Fermilab

The Noble Liquid Test Facility (NLTF) at Fermilab is a liquid argon detector R\&D facility open to the national and international HEP community. The facility consists of 4 permanent cryostats, ranging from 250L up to 3000L, open space for small open dewar testing, and an optical test stand facility capable of measuring the optical properties of materials and characterizing photon detectors. NLTF’s strongest advantage is its capability to provide ultra-pure LAr in a reliable manner. Its inline filters are capable of filtering all of the three biggest contaminants for standard LAr detectors, O$_2$ and H$_2$O down to $< 1$ppb and N$_2$ $< 1$ppm. This is critical for the users of the test stands as small levels of impurities can dramatically change the efficiency of LArTPCs for the collection of charge and light. The smallest cryostat is mainly used for material testing, a service provided to the international HEP community interested in understanding how the introduction of a specific material might affect the electron lifetime in LAr. The test stands can be equipped with a purity monitor, which allows measuring the electron lifetime in real time, as well as gas sampling and analyzing, and in the near future, local recirculation and filtering. The facility has hosted many successful R\&D projects, which have published their results in well-known journals and talks. A few examples of such projects are: NIR light production in LAr and GAr, the characterization of VUV metalenses, the testing of new filter media capable of filtering N$_2$ from LAr, high voltage studies and direct charge amplification in LAr, and various doping studies.

Blaszczyk, Flor María [Fermilab]↗

Massively scalable Kerr comb-driven silicon photonic link

Abstract The growth of computing needs for artificial intelligence and machine learning is critically challenging data communications in today’s data-centre systems. Data movement, dominated by energy costs and limited ‘chip-escape’ bandwidth densities, is perhaps the singular factor determining the scalability of future systems. Using light to send information between compute nodes in such systems can dramatically increase the available bandwidth while simultaneously decreasing energy consumption. Through wavelength-division multiplexing with chip-based microresonator Kerr frequency combs, independent information channels can be encoded onto many distinct colours of light in the same optical fibre for massively parallel data transmission with low energy. Although previous high-bandwidth demonstrations have relied on benchtop equipment for filtering and modulating Kerr comb wavelength channels, data-centre interconnects require a compact on-chip form factor for these operations. Here we demonstrate a massively scalable chip-based silicon photonic data link using a Kerr comb source enabled by a new link architecture and experimentally show aggregate single-fibre data transmission of 512 Gb s −1 across 32 independent wavelength channels. The demonstrated architecture is fundamentally scalable to hundreds of wavelength channels, enabling massively parallel terabit-scale optical interconnects for future green hyperscale data centres.

Rizzo, Anthony (ORCID:000000034752797X)↗

Implementation of an impurity diagnostic suite on the Pegasus-III experiment

A suite of diagnostics used to assess impurity content and dynamics has been updated, upgraded, and installed on the Pegasus-III Experiment. Typical plasma parameters during local helicity injection start-up are τ shot ~10 ms, n e ~ 1 × 10 19 m –3 , and T e ~ 50 eV. The deployed diagnostics are compatible with this modest temperature and density regime and provide species identification, source localization, and estimation of radiation losses. Impurity species are determined by recording time-evolving, single line-of-sight spectra at 1.25 kfps using a SPRED (Survey, Poor Resolution, Extended Domain) vacuum ultraviolet spectrometer. SPRED is equipped with 450 g/mm grating, giving a spectral resolution of 0.33 nm and a spectral range from ~10 to 110 nm, useful to identify light impurity species in this temperature and density range. An absolutely calibrated spectrometer that collects light from the plasma at R tan = 15.9 cm and Δt ≥ 2 ms is used as a visible survey spectrometer and for continuum measurements. The radiated power from the plasma is estimated with a photodiode-based diagnostic. Two 16-channel absolute extreme ultraviolet diode arrays are placed behind pinhole apertures, resulting in 32 lines of sight at Z = 0, with a spatial resolution of 2–3 cm and a time response of 60 kHz. A photometrically calibrated collinear D α /near infrared filtered photodiode-based system measures the D α emission and around 1040 nm. All these instruments have been designed to suppress electromagnetic interference from megawatt-class switching power supplies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detection of scintillation light in noble gases with wavelength-shifting optical fibers

Wavelength-shifting (WLS) techniques enable particle detectors based on noble gases, whose scintillation light is predominantly emitted in the vacuum-ultraviolet. We investigate WLS fibers coated with tetraphenyl butadiene (TPB) for scintillation light detection in gaseous xenon and argon at pressures up to 8.5 bar, motivated by future high-pressure xenon time-projection chambers of the NEXT program. Two detector configurations are studied: an elongated high-pressure vessel with four PTFE panels equipped with WLS fibers read by temperature-stabilized SiPMs, and a compact box-shaped detector operated at 1 bar Xe with WLS fibers read out by PMTs. Both operate with continuous gas purification. The detector response is characterized using cosmic muons and alpha particles from a $^{241}$Am source. With the SiPM setup, we measure a light collection efficiency (LCE) of ${1.18 \pm 0.01~\mathrm{(sta.)}~^{+0.07}_{-0.09}~\mathrm{(sys.)}~\%}$ for xenon and ${1.07 \pm 0.01~\mathrm{(sta.)}~^{+0.06}_{-0.08}~\mathrm{(sys.)}~\%}$ for argon. With PMT readout, we measure a LCE of ${0.45 \pm 0.01~\mathrm{(sta.)} \pm 0.05~\mathrm{(sys.)}~\%}$ in xenon, in agreement with the SiPM result once photon detection efficiency is accounted for. Average scintillation waveforms in xenon and argon are studied to assess the time structure of the emitted light. Cosmic-muon measurements yield a mean energy required to produce a scintillation photon $45\pm7~\mathrm{(sta.)}~^{+4}_{-5}~\mathrm{(sys.)}~\mathrm{eV}$ at 1.5 bar, in agreement with the literature. The results demonstrate that TPB-coated WLS fiber systems can reliably detect scintillation light in high-pressure gaseous noble detectors, with a LCE representing an upper limit for realistic large-scale TPCs, where additional photon losses from materials and fiber attenuation are expected.

Soleti, S. R. [Donostia Intl. Phys. Ctr., San Seba↗

Basic Research of Intrinsic Tamper indication Markings and Patterns defined by Pulsed Laser Irradiation

With our previous research, it was found that surface asperities or roughness must be present to create periodic surface structures upon laser exposure. In particular, an initial rough surface morphology (such as that found with a machined surface) provides multiple sites for light scattering, which underlies the formation of periodic ripple morphologies. Light scattering from a random surface creates patterns of periodic structures (with complex orientations) that could be used as intrinsic markings for tagging materials and equipment. Despite these initial findings, the fundamental mechanisms that give rise to periodic surface structures and their characteristic shapes were not identified in prior research.

36 MATERIALS SCIENCE↗

Cybersecurity Governance

Cybersecurity governance helps an organization detect, prevent, and respond to cyber incidents by establishing cybersecurity policies and procedures for use across the enterprise. As modern energy systems become increasingly reliant on smaller and decentralized generation sources-equipped with complex, data-driven communications-governance will be of growing importance for the continued protection of the electric grid. This presentation sheds light on the important aspects of cybersecurity governance, best practices to ensure a culture of cybersecurity, and approaches to frequent monitoring and assessment of an organization's cybersecurity posture.

business requirements↗

Development of a Scalable Risk-informed Predictive Maintenance Cloud-based Strategy at Nuclear Power Plants

The fact that light-water reactor operation and maintenance costs are prohibitively expensive and contribute to the premature decommissioning of nuclear power plants is partly due to how the equipment is monitored. In recent years, cloud computing has emerged as a dominant technology, as its low cost, computing and storage adaptability, and ability to host applications across numerous virtual infrastructures potentially make it a cost-effective alternative to onsite storage and diagnostics. In this paper, a technological assessment is carried out on a provisional cloud deployment architecture for a nuclear power plant predictive monitoring system. This cloud-based monitoring system would enable maintenance and diagnostic analysts and other authorized plant users to remotely monitor equipment functionality, thus enabling early fault detection and effective predictive maintenance practices. To provide data processing and storage, sensor device networking, and database management, the Microsoft Azure cloud platform is utilized as part of the proposed cloud architecture; however, this analysis could be extended to other cloud computing service providers as well. The focus of this paper is on application of cloud resources for enabling predictive maintenance, identification of technological hurdles associated with moving to a cloud-computing-based architecture, and potential benefits from moving to a centralized cloud system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Considerations for Department of Defense Implementation of Zero-Emission Vehicles and Charging Infrastructure

This guide provides a roadmap to comply with Executive Order (EO) 14057 requirements and transition to a zero-emission vehicle (ZEV) fleet efficiently and quickly. EO 14057 on Catalyzing Clean Energy Industries and Jobs Through Federal Sustainability requires the Department of Defense (DoD) to transition its non-tactical vehicles to a 100% ZEV fleet, including 100% of light-duty acquisitions by 2027 and 100% of medium- and heavy-duty acquisitions by 2035. The report covers planning for ZEVs and electric vehicle supply equipment (EVSE), roles and responsibilities of key stakeholders in designing EVSE, and execution issues including acquisition, installation, and ongoing fleet management.

33 ADVANCED PROPULSION SYSTEMS↗

Low-Cost Preform and Molding Processes

The entry cost for prototyping a composite component for manufacture using automated, high rate processes is prohibitively expensive in many cases, especially for small business, where tooling costs may be several $100k. Discussions with industry also indicate that many small companies, tier 1 and 2 suppliers, have an interest to mold composite parts but do not want to deal with the capital cost, material handling issues, and labor associated with dry fiber preforming operations. While the molders may locate near the end user for logistics reasons, it may be more cost effective for the performer to remain regional and invest in capital equipment to support preform automation, thus keeping costs to a minimum. This project was designed to explore and demonstrate several options to meet these industry needs. Dry fiber preforming approaches were evaluated which allow for low pressure resin infusion, single sided tooling options such a vacuum assisted resin transfer molding (VARTM) or low pressure resin transfer molding (RTM-light). Unlike sheet molding compound, SMC compression molding where typical molding pressures of 1000 psi are required to push material into the desired location; positioning of a dry fiber preform into the desired location on the tool allows for low molding pressures of 10-50 psi. Lower molding pressures allow for use of low cost, additive fabrication of polymeric tooling. Polymeric tooling is suitable for rapid part prototyping and limited production. Dry fiber preforming approaches evaluated included use of commercial chopped strand mat, robotic chopper gun deposition, and continuous fiber preform augmentation using tailored fiber placement (TFP). Use of chopped strand mat does not require a robotic deposition method, however a cutting table is generally required and there is typically 20-30% scrap generation. While various fiber areal weights are available, the preform is not readily optimized for minimal fiber use or weight savings. In contrast, a robotic chopper gun approach allows for localized deposition where fiber is required to meet structural requirements. The robotic method is highly automated and minimizes fiber scrap, however the capital cost of the equipment and engineering labor for programming can result in higher preform cost compared to chopped strand mat in certain cases depending on preform complexity. Dry fiber preforming using the robotic chopper gun method allows for creation of three dimensional forms. This approach may be ideal for molding in-house, or if the preforms stack together densely to allow for efficient shipping. Applications evaluated for this program considered trade-off between fabrication of a fully 3D preform versus production of a flat preform which is designed to readily drape into the final desired shape. Such a preform design greatly simplifies robotic programming and requires no specialized tooling. The flat preforms are easily stacked and shipped to the final molding location. Flat preforms are much easier to augment with TFP continuous fiber to provide local reinforcement. The demonstration and evaluation of these preforming and tooling methods were completed on three component applications. The first application was a battery box cover for an electric vehicle which was highly three dimensional. The second demonstrator article was comprised of complex contours and was used to demonstrate the use of TFP and RTM-light molding process. The third demonstration article was the roof of an operator’s cab for large construction equipment. The roof is relatively flat however it is comprised of complex changes in thickness which clearly demonstrate the advantage of robotic chopper gun approach as compared to using numerous preform layers of chopped strand mat. The cost trades for the various preforming methods are summarized to help guide the reader as to preforming method considerations. Finally, these demonstrations all used glass fiber roving. A fourth, exploratory task was added to evaluate the ability to make preforms using Zoltek’s carbon fiber split tow roving. We were able to adapt the chopper gun to make flat preforms for laminate testing, but further development effort would be required to make suitable preforms.

36 MATERIALS SCIENCE↗

Ultrafast optical modulation of vibrational strong coupling in ReCl(CO) 3 (2,2-bipyridine)

Polaritons – hybrid light-matter states formed from the strong coupling of a bright molecular transition with a confined photonic mode – may offer new opportunities for optical control of molecular behavior. Vibrational strong coupling (VSC) has been reported to impact ground-state chemical reactivity, but its influence on electronic excited-state dynamics remains unexplored. Here, we take a first step towards excited-state VSC by demonstrating optical modulation of the ReCl(CO) 3 (bpy), (bpy = 2,2-bipyridine) complex under VSC using femtosecond ultraviolet (UV)-pump/infrared (IR)-probe spectroscopy. We establish ground-state VSC of ReCl(CO) 3 (bpy) in a microfluidic Fabry-Pérot cavity equipped with indium tin oxide (ITO)-coated mirrors. ITO is effectively dichroic as it is reflective in the IR and transmissive in the UV-visible and therefore minimizes optical interference. Excitation with UV pump light drives ReCl(CO) 3 (bpy) into a manifold of electronic excited states that subsequently undergo non-radiative relaxation dynamics. We probe the transient response of the strongly-coupled system in the mid-IR, observing both Rabi contraction and cavity-filtered excited-state absorption signatures. We reconstruct the intrinsic response of intracavity molecules from the transient cavity transmission spectra to enable quantitative comparison with extracavity control experiments. We report no changes in the excited-state dynamics of ReCl(CO) 3 (bpy) under ground-state VSC. However, we do observe significant amplification of transient vibrational signals due to classical cavity-enhanced optical effects. This effort lays the groundwork to pursue direct excited-state VSC aimed at modulating photochemical reactivity.

cavity-enhanced spectroscopy↗

Exploring quantum statistics for massive Dirac and Majorana neutrinos using spinor-helicity techniques

Recently, there has been interest in the applicability of quantum statistics to distinguish Dirac from Majorana neutrinos in multineutrino final states. In particular, debate has arisen over the validity of the Dirac-Majorana confusion theorem in these processes, i.e., that any distinction between the Dirac and Majorana processes goes to zero as the neutrino mass goes to zero. Here we approach this problem equipped with spinor-helicity methods generalized for massive Dirac and Majorana fermions. We explicitly calculate all helicity amplitudes, and their squares, for the decay of a light scalar particle to two neutrinos and two oppositely charged leptons. This allows us to pinpoint the crucial steps which could lead to claims of a violation of the confusion theorem. We show that, if the correct antisymmetrization of Dirac to Majorana amplitudes is used, identification of which is clear in this framework, and all relevant contributions are appropriately summed, a scalar decay into two charged leptons and two neutrinos satisfies the Dirac-Majorana confusion theorem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low Carbon Technology Strategies: Hospital

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon hospitals within their existing building portfolios. Hospitals typically include complex heating and cooling systems and specialty medical equipment.

analytics↗

Literature Review of Optocouplers, Their polymer Components and Current Applicaitons

Optocouplers, also called optoisoloators and photocouplers, are devices that use a light emitting diode (LED) to conduct an electrical signal. The LED receives an electrical signal and emits light proportional to that signal. The light is then received by a photodetector and the signal is propagated. Optocouplers provide a high degree of electrical isolation and are therefore used extensively in commercial electronic equipment. Variations in optocouplers come from the type of photodetector used, the anatomy of the contents and the encapsulating polymers used. Current research involves investigating the tolerance of optocouplers to radiation for the purpose of improving spacecraft and satellites, as well as identifying failure mechanisms and improving design.

42 ENGINEERING↗