Search NASA⌕ Search

SEARCH · Search NASA

Results for “LIQUID ROTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Effects of rotation and magnetic field on the onset of convective instability in a liquid layer due to buoyancy and surface tension

Thermocapillary stability characteristics of a horizontal liquid layer heated from below rotating about a vertical axis and subjected to a uniform vertical magnetic field are analyzed under a variety of thermal and electromagnetic boundary conditions. Results based on analytical solutions to the pertinent eigenvalue problems are discussed in the light of earlier work on special cases of the more general problem considered here to show in particular the effects of the heat transfer, nonzero curvature and gravity waves at the two-fluid interface. Although the expected stabilizing action of the Coriolis and Lorentz force fields in this configuration are in evidence the optimal choice of an appropriate range for the relevant parameters is shown to be critically dependent on the interfacial effects mentioned above.

Sarma, G. S. R.↗

Interface stability in a slowly rotating, low gravity tank Experiments

Analytical models of liquid in partially-filled rotating tanks predict both the shape of the interface between the liquid and its vapor, and the stability of that interface. The models are of necessity incomplete and experimental data are needed to assess the approximations made. Presented are preliminary experimental studies both in the laboratory and in the low-gravity environment of a free-falling aircraft. Emphasis is placed on bubbles which intersect the container boundaries. Measurements of rotating equilibrium bubble shapes are in agreement with theoretical profiles derived from Laplace's formula. The interface shape depends on the contact angle, the radius of intersection with container, and the ratio of centrifugal force to surface tension.

Leslie, F.↗

Gravity jitter excited cryogenic liquid slosh waves in microgravity environment

The dynamical behavior of fluids, in particular the effect of surface tension on partially-filled rotating fluids (cryogenic liquid helium and helium vapor) in a full-scale Gravity Probe-B Spacecraft liquid helium container tank without probe imposed by various frequencies of gravity jitter have been investigated. Results disclose the conditions for the excitation of large amplitude slosh waves which should be avoided in the design of cryogenic liquid propellant system.

Hung, R. J.↗

Laser velocimeter application to oscillatory liquid flows

A laser velocimeter technique was used to measure the mean velocity and the frequency characteristics of an oscillatory flow component generated with a rotating flapper in liquid flow system at Reynolds numbers approximating 93,000. The velocity information was processed in the frequency domain using a tracker whose output was used to determine the flow spectrum. This was accomplished with the use of an autocorrelator/Fourier transform analyzer and a spectrum averaging analyzer where induced flow oscillations up to 40 Hz were detected. Tests were conducted at a mean flow velocity of approximately 2 m/s. The experimental results show that the laser velocimeter can provide quantitative information such as liquid flow velocity and frequency spectrum with a possible application to cryogenic fluid flows.

Gartrell, L. R.↗

Three-dimensional spacecraft angular momentum fluctuations due to gravity jitter excited slosh waves in liquid propellant system

The paper investigates the dynamical behavior of fluids affected by asymmetric gravity jitter oscillations, in particular the effect of surface tension on partially filled rotating fluids (cryogenic liquid helium and helium vapor) in a subscale Gravity Probe-B spacecraft propellant dewar tank imposed by time-dependent variation in the direction of the background gravity environment. It is shown that lower frequency gravity jitter imposed on the time-dependent variation in the direction of background gravity induced a greater amplitude of oscillations and a stronger degree of asymmetry in liquid-vapor interface geometry than that made by the higher frequency gravity jitter. Fluctuations of angular momentum and spacecraft moment caused by slosh wave excitation are also studied. Slosh-wave-induced fluctuations in angular momentum and moment are important factors in spacecraft dynamics, guidance, and attitude controls.

Hung, R. J.↗

Computer code for gas-liquid two-phase vortex motions: GLVM

A computer program aimed at the phase separation between gas and liquid at zero gravity, induced by vortex motion, is developed. It utilizes an explicit solution method for a set of equations describing rotating gas-liquid flows. The vortex motion is established by a tangential fluid injection. A Lax-Wendroff two-step (McCormack's) numerical scheme is used. The program can be used to study the fluid dynamical behavior of the rotational two-phase fluids in a cylindrical tank. It provides a quick/easy sensitivity test on various parameters and thus provides the guidance for the design and use of actual physical systems for handling two-phase fluids.

Yeh, T. T.↗

Effect of asymmetric gravity jitter excited slosh waves at liquid-vapor interface under microgravity

The dynamical behavior of fluids affected by the asymmetric gravity jitter oscillations, in particular the effect of surface tension on partially-filled rotating fluids (cryogenic liquid helium and helium vapor) in a sub-scale Gravity Probe-B Spacecraft propellant dewar tank imposed by time-dependent various directions of background gravity environment have been investigated. Results show that lower frequency gravity jitter imposed on the time-dependent variations of the direction of background gravity induced a greater amplitude of oscillations and a stronger degree of asymmetry in liquid-vapor interface geometry than that made by the higher frequency gravity jitter. Furthermore, the greater the components of background gravity in radial and circumferential directions will provide a greater contribution in driving more to the increasing amplitude and degrees of symmetry of liquid-vapor interface profiles which, in turn, modify the disturbance of moment of inertia and angular momentum of spacecraft.

Hung, R. J.↗

Rotary plant growth accelerating apparatus

Rotary plant growth accelerating apparatus for increasing plant yields by effectively removing the growing plants from the constraints of gravity and increasing the plant yield per unit of space is described. The apparatus is comprised of cylindrical plant beds supported radially removed from a primary axis of rotation, with each plant bed being driven about its own secondary axis of rotation and simultaneously moved in a planetary path about the primary axis of rotation. Each plant bed is formed by an apertured outer cylinder, a perforated inner cylinder positioned coaxially, and rooting media disposed in the space between. A rotatable manifold distributes liquid nutrients and water to the rooting media through the perforations in the inner cylinders as the plant beds are continuously rotated by suitable drive means.

Dedolph, R. D.↗

Oscillations of a compound drop system undergoing rotation

A compound liquid-drop system is comprised of three immiscible concentric fluids: a core fluid of density p(i) surrounded by a shell of density p(s) which is embedded in a medium of density p(o). In this analysis, the fluids are incompressible and inviscid. The effect of rotation upon the modes of oscillation of a compound drop is investigated. Rotation rate is considered as a small perturbation of the normal modes of the compound drop, thus introducing the effects of a Coriolis force and a centrifugal distortion.

Lyell, M. J.↗

Dip molding to form intricately-shaped medical elastomer devices

Preshaped mandrel mounted on rotating mechanism is partically immersed in tank filled with liquid elastomer. While mandrel rotates, elastomer film forms om mandrel surface due to surface tension and capillary behavior of liquid. Devices with well-defined flanges can be made using process.

Broyles, H. F.↗

Liquid Motion Experiment Flight Test Results

The Liquid Motion Experiment (LME), designed to study the effects of liquid motion in rotating tanks, was flown on STS 84. LME was essentially a spin table that created a realistic nutation motion of scale-model tanks containing liquid. TWo spherical and two cylindrical transparent tanks were tested simultaneously, and three sets of such tanks were employed to vary liquid viscosity, fill level, and propellant management device (PMD) design. All the tanks were approximately 4.5 inches diameter. The primary test measurements were the radial and tangential torques exerted on the tanks by the liquid. Resonant frequencies and damping of the liquid oscillations were determined by sine sweep tests. For a given tank shape, the resonant frequency depended on fill level. For the cylindrical tanks, the resonances had somewhat different frequencies for the tangential axis (0.55 to 0.75 times spin rate) and the radial axis (0.73 to 0.78 times spin rate), and the tangential axis resonance agreed more closely with available analytical models. For the spherical tanks, the resonant frequencies were between 0.74 to 0.77 times the spin rate and were the same for the tangential and radial axes. The damping coefficients varied from about I% to 3% of critical, depending on tank shape, fill level, and liquid viscosity. 'Me viscous energy dissipation rates of the liquid oscillations were determined from sine dwell tests. The LME energy dissipation rates varied from 0.3 to 0.5 times the estimates obtained from scaling previous ground tests and spacecraft flight data. The PNDs sometimes enhanced the resonances and energy dissipation rates and sometimes decreased them, which points out the need to understand better the effects of PMD on liquid motion as a function of PMD and tank design.

Chato David J.↗

Dynamics of rotating and oscillating free drops

The Dynamics of Rotating and Oscillating Free Drops (DROP) experiment is to be performed using the Drop Dynamics Module (DDM). The main scientific objectives of the DROP experiment are the study of the equilibrium figures of a rotating drop and the study of the large-amplitude oscillations of a liquid drop. The objective of the DROP experiment in relation to the DDM is to establish the advantages of conducting future drops and bubbles experiments in space. The DROP experiment will be subjected to continual to ensure that the experiments are scientifically current and available. The two component experiments (rotation and oscillation) of the DROP experiment have been chosen as the simplest experiments representative of the entire class of drop dynamics experiments. The component experiment on the equilibrium shapes of a rotating liquid drop of a simple liquid is not only an important and interesting experiment in its own right, but is also the simplest gyrostatic experiment that can be performed. In later experiments, more complicated liquids can be used; bubbles can be included; and the dynamics of rotating drops can be studied. This experiment, as it now stands, is an important exercise of the module's ability to provide drop rotation and the requisite science data.

Wang, T. G.↗

Slosh wave excitation in a partially filled rotating tank due to gravity jitters in a microgravity environment

The dynamical behavior of fluids, in particular the effect of surface tension on partially-filled rotating fluids (cryogenic liquid helium and helium vapor), in a full-scale Gravity Probe-B Spacecraft propellant tank without probe imposed by various frequencies of gravity jitters have been investigated. Twelve case studies of slosh wave excitation due to various frequencies of gravity jitters under different rotating speeds of propellant tank and different levels of background gravity environment have been numerically simulated. Results disclose the conditions for the excitation of large amplitude slosh waves which shall be avoided in the design of cryogenic liquid propellant system.

Hung, R. J.↗

Prediction of pump cavitation performance

A method for predicting pump cavitation performance with various liquids, liquid temperatures, and rotative speeds is presented. Use of the method requires that two sets of test data be available for the pump of interest. Good agreement between predicted and experimental results of cavitation performance was obtained for several pumps operated in liquids which exhibit a wide range of properties. Two cavitation parameters which qualitatively evaluate pump cavitation performance are also presented.

Moore, R. D.↗

Measuring Thicknesses of Wastewater Films

Sensor determines when thickness of film of electrically conductive wastewater on rotating evaporator drum exceeds preset value. Sensor simple electrical probe that makes contact with liquid surface. Made of materials resistant to chemicals in liquid. Mounted on shaft in rotating cylinder, liquid-thickness sensor extends toward cylinder wall so tip almost touches. Sensor body accommodates probe measuring temperature of evaporated water in cylinder.

Schubert, F. H.↗

Mathematical and computational studies of equilibrium capillary free surfaces

The results of several independent studies are presented. The general question is considered of whether a wetting liquid always rises higher in a small capillary tube than in a larger one, when both are dipped vertically into an infinite reservoir. An analytical investigation is initiated to determine the qualitative behavior of the family of solutions of the equilibrium capillary free-surface equation that correspond to rotationally symmetric pendent liquid drops and the relationship of these solutions to the singular solution, which corresponds to an infinite spike of liquid extending downward to infinity. The block successive overrelaxation-Newton method and the generalized conjugate gradient method are investigated for solving the capillary equation on a uniform square mesh in a square domain, including the case for which the solution is unbounded at the corners. Capillary surfaces are calculated on the ellipse, on a circle with reentrant notches, and on other irregularly shaped domains using JASON, a general purpose program for solving nonlinear elliptic equations on a nonuniform quadrilaterial mesh. Analytical estimates for the nonexistence of solutions of the equilibrium capillary free-surface equation on the ellipse in zero gravity are evaluated.

Albright, N.↗