The effect of oxygen concentration on the speciation of laser ablated uranium

Abstract In order to model the fate and transport of particles following a nuclear explosion, there must first be an understanding of individual physical and chemical processes that affect particle formation. One interaction pertinent to fireball chemistry and resultant debris formation is that between uranium and oxygen. In this study, we use laser ablation of uranium metal in different concentrations of oxygen gas, either 16 O 2 or 18 O 2 , to determine the influence of oxygen on rapidly cooling uranium. Analysis of recovered particulates using infrared absorption and Raman spectroscopies indicate that the micrometer-sized particulates are predominantly amorphous UO x (am-UO x , where 3 ≤ x ≤ 4) and UO 2 after ablation in 1 atm of pure O 2 and a 1% O 2 /Ar mixture, respectively. Energy dispersive X-ray spectroscopy (EDS) of particulates formed in pure O 2 suggest an O/U ratio of ~ 3.7, consistent with the vibrational spectroscopy analysis. Both am-UO x and UO 2 particulates convert to α-U 3 O 8 when heated. Lastly, experiments performed in 18 O 2 environments show the formation of 18 O-substituted uranium oxides; vibrational frequencies for am-U 18 O x are reported for the first time. When compared to literature, this work shows that cooling timescales can affect the structural composition of uranium oxides (i.e., crystalline vs. amorphous). This indicator can be used in current models of nuclear explosions to improve our predicative capabilities of chemical speciation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Growth and patterning of laser ablated superconducting YBa2Cu3O7 films on LaAlO3 substrates

A high quality superconducting film on a substrate with a low dielectric constant is desired for passive microwave circuit applications. In addition, it is essential that the patterning process does not effect the superconducting properties of the thin films to achieve the highest circuit operating temperatures. YBa2Cu3O7 superconducting films were grown on lanthanum aluminate substrates using laser ablation with resulting maximum transition temperature (T sub c) of 90 K. The films were grown on a LaAlO3 which was at 775 C and in 170 mtorr of oxygen and slowly cooled to room temperature in 1 atm of oxygen. These films were then processed using photolithography and a negative photoresist with an etch solution of bromine and ethanol. Results are presented on the effect of the processing on T(sub c) of the film and the microwave properties of the patterned films.

Warner, J. D.↗

Fe-carbide/Fe-oxide-based nanocomposites synthesized as magnetic nanomaterials via laser ablation synthesis in solution (LASiS)

Magnetic nanostructured materials (MNMs) have gained prominence in materials technology developments owing to their potential biomedical applications for hyperthermia cancer treatment, and transplant organ cryopreservation. Herein, we report the facile and cost-effective synthesis of Fe-based composite MNMs, comprising both Fe@Fe 2 O 3 and Fe 3 C@C core-shell nanoparticles (NPs), via Laser Ablation Synthesis in Solution (LASiS) using Fe targets ablated under acetone and toluene. Detailed materials characterizations using electron microscopy-based imaging, diffraction studies, and spectroscopic analyses - including Raman and Mössbauer spectroscopy - relate the structure-composition properties for different Fe-oxide/carbide phases in the aforesaid MNMs to their respective magnetic responses. Specifically, we confirm the presence of ultra-small (2–10 nm) amorphous Fe-oxide NPs, as well as Fe@Fe 2 O 3 core-shell NPs (20–40 nm) in the samples synthesized by ablating Fe under acetone. In contrast, samples synthesized under toluene indicate a higher concentration of Fe 3 C@C core-shell NPs (20–40 nm) with a relatively low concentration of Fe 2 O 3 NPs (2–10 nm). Furthermore, the crystallinity of the metallic phases and carbonaceous shell coatings are systematically increased by carrying out LASiS under heated toluene (up to ~95 °C). Importantly, mössbauer spectroscopy results indicate that the elevation in toluene temperature leads to an increase in the concentrations of Fe 3 C@C NPs from ~40 % to ~53 % (at.).

36 MATERIALS SCIENCE↗

Dependence of millimeter wave surface resistance on the deposition parameters of laser ablated YBa2Cu3O(x) thin films

Measurements of millimeter-wave surface resistance versus temperature have been performed for YBa2Cu3O(x) thin films on 100 line-type SrTiO(3) substrates using a TE(011) cylindrical copper cavity at 80 GHz. The 0.6-micron thick films were grown at several deposition temperatures in the range 690 C to 810 C by means of a pulsed excimer laser ablation technique. A surface resistance minimum (60 milliohm at 77 K) near 770 C is shown to correlate with a minimum in c-axis lattice parameter (11.72 A). The highest value of Tc also occurs near this temperature. The surface resistance of films deposited at 790 C on 110 line-type LaAlO3 subtrates is lower, reaching 8 milliohm at 98 GHz and 80 K, demonstrating the influence of substate material on film quality.

Wosik, J.↗

A preliminary investigation into the feasibility of laser ablation U–Pb isotope ratio measurement via all‐faraday cup detection with 10 11 ‐ and 10 13 ‐Ω amplifiers on the Neoma multicollector‐inductively coupled plasma‐mass spectrometer

Rationale Signal detection for uranium–lead (U–Pb) dating of zircon is typically performed via ion counters. Here, we develop a preliminary understanding of the strengths and limitations of faraday‐cup‐based detection. Methods A suite of zircon reference materials and the NIST‐610 glass were sampled using laser ablation followed by U–Pb isotope ratio measurement on a Neoma multicollector‐inductively coupled plasma‐mass spectrometer. Results We were able to produce geologically accurate 207 Pb/ 206 Pb, 206 Pb/ 238 U, and 207 Pb/ 235 U ratios for the NIST‐610 glass and the zircon standards, with ages ranging from ~2.5 Ga to ~337 Ma (TanBrown A, Oracle, 91550, Mud Tank, Temora, and Plešovice). Two of the younger zircon standards examined (94‐35, ~55.6 Ma, and Fish Canyon, 28.6 Ma) yielded accurate 206 Pb/ 238 U but not 207 Pb/ 235 U or 207 Pb/ 206 Pb ratios, whereas the youngest zircon standard (Penglai, ~4.4 Ma) failed for all three ratios of interest. The accuracy and precision of the all‐faraday method are directly tied to signal intensity, with reliable data capable of being produced even when both isotopes in a ratio have signals below ~0.001 V (equivalent to ~62 500 cps on an ion counter). Conclusion The all‐faraday cup multicollection method provides sufficient sensitivity to obtain geologically meaningful U–Pb data, with possible advantages being that laser pit depth‐dependent changes in the observed interelemental fractionation behavior may be easier to correct using a static collector configuration compared to when the ion beam is swept across a single detector while also removing the need for an interdetector‐type calibration. Further work is needed to refine the all‐faraday cup method (e.g., application of background subtraction and common Pb corrections, outlier removal, and interelement as well as down‐hole fractionation corrections), but our initial results demonstrate that the faraday detector method has sufficient sensitivity to warrant further study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave conductivity of laser ablated YBaCuO superconducting films and its relation to microstrip transmission line

The discovery of high temperature superconductor oxides has raised the possibility of a new class of millimeter and microwave devices operating at temperatures considerably higher than liquid helium temperatures. Therefore, materials properties such as conductivity, current density, and sheet resistance as a function of temperature and frequency, possible anisotropies, moisture absorption, thermal expansion, and others, have to be well characterized and understood. The millimeter wave response was studied of laser ablated YBa2Cu3O(7-x)/LaAlO3 thin films as a function of temperature and frequency. In particular, the evaluation of their microwave conductivity was emphasized, since knowledge of this parameter provides a basis for the derivation of other relevant properties of these superconducting oxides, and for using them in the fabrication of actual passive circuits. The microwave conductivity for these films was measured at frequencies from 26.5 to 40.0 GHz, in the temperature range from 20 to 300 K. The values of the conductivity are obtained from the millimeter wave power transmitted through the films, using a two fluid model.

Bhasin, K. B.↗

Microwave conductivity of laser ablated YBa2Cu3O(7-delta) superconducting films and its relation to microstrip transmission line performance

The discovery of high temperature superconductor oxides has raised the possibility of a new class of millimeter and microwave devices operating at temperatures considerably higher than liquid helium temperatures. Therefore, materials properties such as conductivity, current density, and sheet resistance as a function of temperature and frequency, possible anisotropies, moisture absorption, thermal expansion, and others, have to be well characterized and understood. The millimeter wave response of laser ablated YBa2Cu3O(7-delta)/LaAlO3 thin films was studied as a function of temperature and frequency. In particular, the evaluation of their microwave conductivity was emphasized, since knowledge of this parameter provides a basis for the derivation of other relevant properties of these superconducting oxides, and for using them in the fabrication of actual passive circuits. The microwave conductivity for these films was measured at frequencies from 26.5 to 40.0 GHz, in the temperature range from 20 to 300 K. The values of the conductivity are obtained from the millimeter wave power transmitted through the films, using a two fluid model.

Bhasin, K. B.↗

An Investigation on the Use of a Laser Ablation Treatment on Metallic Surfaces and the Influence of Temperature on Fracture Toughness of Hybrid Co-Cured Metal-PMC Interfaces

Hybrid composite laminates that contain alternating layers of titanium alloys and carbon fabric reinforced polyimide matrix composites (PMC) are excellent candidates for light-weight, high-temperature structural materials for high-speed aerospace vehicles. The delamination resistance of the hybrid titanium-PMC interface is of crucial consideration for structural integrity during service. Here, we report the first investigations on the use of laser ablation in combination with sol-gel treatment technique on Ti/NiTi foil surfaces in co-cured hybrid polyimide matrix composite laminates. Mode-I and mode-II fracture toughness of the hybrid Ti/NiTi-PMC interface as a function of temperature were determined via experimental testing and finite element analysis.

Connell, John↗

The Laser Ablation Ion Funnel: Sampling for in situ Mass Spectrometry on Mars

A considerable investment has been made by NASA and other space agencies to develop instrumentation suitable for in situ analytical investigation of extra terrestrial bodies including various mass spectrometers (time-of-flight, quadrupole ion trap, quadrupole mass filters, etc.). However, the front-end sample handling that is needed to collect and prepare samples for interrogation by such instrumentation remains underdeveloped. Here we describe a novel approach tailored to the exploration of Mars where ions are created in the ambient atmosphere via laser ablation and then efficiently transported into a mass spectrometer for in situ analysis using an electrodynamic ion funnel. This concept would enable elemental and isotopic analysis of geological samples with the analysis of desorbed organic material a possibility as well. Such an instrument would be suitable for inclusion on all potential missions currently being considered such as the Mid-Range Rover, the Astrobiology Field Laboratory, and Mars Sample Return (i.e., as a sample pre-selection triage instrument), among others.

Johnson, Paul V.↗

Siderophile Element Profile Measurements in Iron Meteorites Using Laser Ablation ICP-MS

Understanding the behaviour of siderophile elements during cooling of iron meteorites can lead to insight into the general thermal histories of the meteorites as well as their respective parent bodies. Traditionally trace element analyses in meteorites have been done using techniques that only measure the average concentration in each phase. With these methods, all of the spatial information with respect to the distribution of an element within one phase is lost. Measuring concentration profiles of trace elements in meteorites is now possible, with the advent of high-resolution analytical techniques such as laser ablation, inductively coupled plasma mass spectrometry (LA-ICP-MS) with spatial resolution <20 microns. [e.g. 1,2] and secondary ion mass spectrometry [3]. These profiles can give more insight into both the partitioning and diffusive behavior of siderophile elements in metal systems relevant to iron meteorites, as well as parent body cooling rates.

Watson, H. C.↗

Detection limits for laser absorption spectroscopy of Li in laser ablation plumes

A high-sensitivity laser absorption spectroscopy (LAS) method is demonstrated for rapid and non-contact analysis of Li in solids. Glass samples with Li concentrations ranging from 1-500 ppm by mass are ablated in 5 Torr air, and time-resolved Li atomic absorption is measured using a tunable laser near 671 nm. Significant improvements in analytical performance over prior laser-induced breakdown techniques are demonstrated. Here, a single-shot limit of detection (LOD) of 180 ppb is shown for fixed wavelength operation, improving to 6 ppb with averaging over 1000 ablation shots (100 s acquisition time). Isotope-resolved Li absorption spectra are measured with a 17 ppb LOD in 40 s. Methods for optimizing LOD based on noise/averaging properties of LAS experiments in LA plumes are discussed.

(020.3260) Isotope shifts↗

Magnesium Isotopes in the Earth, Moon, Mars, and Pallasite Parent Body: High-Precision Analysis of Olivine by Laser-Ablation Multi-Collector ICPMS

Magnesium isotopes potentially offer new insights into a diverse range of processes including evaporation and condensation in the solar nebula, melting and metasomatism in planetary interiors, and hydrothermal alteration [1,2,3,4]. Volatility-related Mg isotopic variations of up to 10 per mil/amu relative to a terrestrial standard have been found in early nebular phases interpreted as evaporation residues [1], and relatively large variations (up to 3 per mil/amu) in the terrestrial mantle have been reported recently [4]. In order to investigate possible differences in the nebular history of material contributing to the terrestrial planets, and to search for evidence of a high-temperature origin of the Moon, we have measured the magnesium isotopic composition of primitive olivines from the Earth, Moon, Mars, and pallasite parent body using laser-ablation multicollector ICPMS.

Norman, M.↗

Single-shot, double-pulse determination of the detonation energy in nanosecond-laser ablation using the blast model

We demonstrate a novel single-shot method to determine the detonation energy of laser-induced plasma and investigate its performance. This approach can be used in cases where there are significant shot-to-shot variations in ablation conditions, such as laser fluctuations, target inhomogeneity, or multiple filamentation with ultrashort pulses. The Sedov blast model is used to fit two time-delayed shadowgrams measured with a double-pulse laser. We find that the reconstruction of detonation parameters is insensitive to the choice of interpulse delay in double-pulse shadowgraphy. In contrast, the initial assumption of expansion dimensionality has a large impact on the reconstructed detonation energy. The method allows for a reduction in the uncertainties of blast wave energy measurements as a diagnostic technique employed in various laser ablation applications.

42 ENGINEERING↗

Below-Band-Gap Laser Ablation Of Diamond For TEM

Thin, electron-transparent layers of diamond for examination in transmission electron microscope (TEM) fabricated from thicker diamond substrates by using laser beam to ablate surface of substrate. Involves use of photon energy below band gap. Growing interest in use of diamond as bulk substrate and as coating material in variety of applications has given rise to increasing need for TEM for characterization of diamond-based materials. Below-band-gap laser ablation method helps to satisfy this need. Also applied in general to cutting and etching of diamonds.

George, Thomas↗

Laser ablation for the synthesis of carbon nanotubes

Single walled carbon nanotubes are produced in a novel apparatus by the laser-induced ablation of moving carbon target. The laser used is of high average power and ultra-fast pulsing. According to various preferred embodiments, the laser produces an output above about 50 watts/cm.sup.2 at a repetition rate above about 15 MHz and exhibits a pulse duration below about 10 picoseconds. The carbon, carbon/catalyst target and the laser beam are moved relative to one another and a focused flow of side pumped, preheated inert gas is introduced near the point of ablation to minimize or eliminate interference by the ablated plume by removal of the plume and introduction of new target area for incidence with the laser beam. When the target is moved relative to the laser beam, rotational or translational movement may be imparted thereto, but rotation of the target is preferred.

Holloway, Brian C.↗

Laser ablation for the synthesis of carbon nanotubes

Single walled carbon nanotubes are produced in a novel apparatus by the laser-induced ablation of moving carbon target. The laser used is of high average power and ultra-fast pulsing. According to various preferred embodiments, the laser produces and output above about 50 watts/cm.sup.2 at a repetition rate above about 15 MHz and exhibits a pulse duration below about 10 picoseconds. The carbon, carbon/catalyst target and the laser beam are moved relative to one another and a focused flow of "side pumped", preheated inert gas is introduced near the point of ablation to minimize or eliminate interference by the ablated plume by removal of the plume and introduction of new target area for incidence with the laser beam. When the target is moved relative to the laser beam, rotational or translational movement may be imparted thereto, but rotation of the target is preferred.

Holloway, Brian C.↗

Laser Ablation Experiments on the Tamdakht H5 Chondrite

High-powered lasers were used to induce ablation and to form fusion crusts in the lab on Tamdakht H5 chondrites and basalt. These ground tests were undertaken to improve our understanding, and ultimately improve our abilty to model and predict, meteoroid ablation during atmospheric entry. The infrared fiber laser at the LHMEL facilty, operated in the continuous wave (i.e. non-pulsed) mode, provided radiation surface heat flux at levels similar to meteor entry for these tests. Results are presented from the first round of testing on samples of Tamdakht H5 ordinary chondrite which were ex-posed to entry-relevant heating rates between 2 and 10 kWcm2.

meteor↗

Observation of laser ablation of silicon as a function of pulse length at constant fluence via time-resolved x-ray spectroscopy

We investigate the ablation of silicon as a function of laser pulse length at a constant fluence using time-resolved x-ray spectroscopy data obtained from OMEGA EP experiments at the University of Rochester's Laboratory for Laser Energetics. Our targets consisted of three-layer planar structures composed of Si (50 μm), Cu (25 μm), and SiO 2 (500 μm) layers. The Si layer was irradiated by a 351-nm laser with varying pulse widths of 250 ps, 500 ps, 1 ns, and 10 ns while maintaining a constant fluence of ~27.9 kJ/cm 2 . Electron temperatures and densities of the ablated plasma were determined by analyzing the time-resolved x-ray spectroscopy data through a comparison of experimental measurements with synthetic results obtained from Si atomic calculations in a steady state and non-local thermodynamic equilibrium. These calculations were computed using PrismSPECT. Additionally, radiation-hydrodynamics simulations with FLASH are used to generate simulated plasma-density and plasma-temperature profiles, which are then compared with the experimental measurements. Our analyses reveal that increasing the laser pulse length at a constant fluence results in a decrease in electron temperatures and densities. Furthermore, the longer pulses with lower intensities lead to deeper ablation regions before reaching the peak ablation but lower ionization balances in the silicon layer. Furthermore, these findings emphasize the critical role of laser pulse length in plasma ablation and shock generation for laser-impulse studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗