Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser Time Transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Development of In-Situ Erosion Measurement Techniques for Application to Real-Time Determination of Plasma Thruster Component Lifetimes

This research has resulted in advancing the laser-based diagnostic capability and the ion optics development in the ion propulsion program at NASA GRC. Laser-based plasma diagnostics have been demonstrated in tabletop experiments and, in the case of LDI, on laboratory hollow cathodes. Assessment by GRC of its resources and priorities two years into the grant lead to a refocusing of the research effort away from the development of a real-time erosion rate measurement technique. The extension of the diagnostic techniques to diagnostic tools has been transferred to graduate students under the technical direction of the PI. These diagnostics may facilitate the development of ion thruster with significantly improved throughput capability for lower-power (10 kW) missions High-Isp, Long-lived ion optics development has proceeded from simple extensions of state-of-the-art geometries to radically different geometries and materials. Full-scale testing of these ion optics has demonstrated a significant advance in the throughput capability of ion thrusters enabling significantly more demanding missions. The capability to predict the throughput was developed and will continue to be upgraded. The performance models have been validated via full-scale testing. Partial validation of the throughput prediction will be completed via an upcoming wear test of the ion optics.

Source record↗

Lasing in N2O and CO2 isotope mixtures pumped by blackbody radiation

The use of N2O and CO2 isotopes as active species for a blackbody radiation pumped laser has been experimentally demonstrated and theoretically analyzed. The results obtained for mixtures containing N2O, (C-13) (O-16)2, and (C-12) (O-18)2 are presented. For the first time, continuous lasing action with blackbody radiation pumping has been obtained for this species. Two active species mixtures were tested, obtaining up to a 100 percent increase in output power due to v-v transfer. A simple model was developed and gain calculations are presented.

Sirota, J. M.↗

Thermal Performance of ATLAS Laser Thermal Control System Demonstration Unit

The second Ice, Cloud, and Land Elevation Satellite mission currently planned by National Aeronautics and Space Administration will measure global ice topography and canopy height using the Advanced Topographic Laser Altimeter System {ATLAS). The ATLAS comprises two lasers; but only one will be used at a time. Each laser will generate between 125 watts and 250 watts of heat, and each laser has its own optimal operating temperature that must be maintained within plus or minus 1 degree Centigrade accuracy by the Laser Thermal Control System (LTCS) consisting of a constant conductance heat pipe (CCHP), a loop heat pipe (LHP) and a radiator. The heat generated by the laser is acquired by the CCHP and transferred to the LHP, which delivers the heat to the radiator for ultimate rejection. The radiator can be exposed to temperatures between minus 71 degrees Centigrade and minus 93 degrees Centigrade. The two lasers can have different operating temperatures varying between plus 15 degrees Centigrade and plus 30 degrees Centigrade, and their operating temperatures are not known while the LTCS is being designed and built. Major challenges of the LTCS include: 1) A single thermal control system must maintain the ATLAS at 15 degrees Centigrade with 250 watts heat load and minus 71 degrees Centigrade radiator sink temperature, and maintain the ATLAS at plus 30 degrees Centigrade with 125 watts heat load and minus 93 degrees Centigrade radiator sink temperature. Furthermore, the LTCS must be qualification tested to maintain the ATLAS between plus 10 degrees Centigrade and plus 35 degrees Centigrade. 2) The LTCS must be shut down to ensure that the ATLAS can be maintained above its lowest desirable temperature of minus 2 degrees Centigrade during the survival mode. No software control algorithm for LTCS can be activated during survival and only thermostats can be used. 3) The radiator must be kept above minus 65 degrees Centigrade to prevent ammonia from freezing using no more than 135 watts of heater power. 4) The LHP reservoir control heater power is limited to 15 watts with a 70 percent duty cycle. 5) The voltage of the power supply can vary between 26 volts direct current and 34 volts direct current during the spacecraft lifetime. A design analysis shows that a single LTCS can satisfy these requirements. However, shutdown of· the LHP is particularly challenging and the shutdown heater must be wired in series with two reservoir thermostats and two CCHP thermostats at different set points. An LTCS demonstration unit has been tested to verify these performance characteristics experimentally prior to proceeding to the final LTCS design and fabrication. Test results showed that the LHP shutdown scheme would be able to shut down the LHP as designed and the reservoir control heater can maintain the ATLAS mass simulator within the plus or minus 1 degrees Centigrade accuracy under various combinations of the heat load, sink temperature, and power supply voltage.

Ku, Jentung↗

Uniformity of Ludwieg tube flows

Pressure and speed of sound measurements are used to obtain averaged gas properties in a Ludwieg combustion tube in which the gas is burned just prior to use. Absorption of a laser beam in the exit flow is used to check the predicted temperature uniformity. The burning process and the heat transfer to the cold walls are modeled. Interferograms of Ludwieg tube boundary layers are utilized to develop a new semiempirical boundary layer expression referred to as the integral density thickness, which is then applied to a recently developed linearized analysis of the effects of this layer. Pressure-time histories are determined for a wide range of tube flow Mach number and aspect ratio. Viscous and nonviscous effects are considered. It is shown that although the influence of the integral density thickness on the flow can be large, a modified linear theory can be used to estimate the effects for arbitrary tube flow Mach number and values of the aspect ratio that include cases where the boundary layers have merged.

Russell, D. A.↗

Observation of Vibrational Relaxation Dynamics in X(sup 3)Sigma(sup -)(sub g) Oxygen Following Stimulated Raman Excitation to the v=1 Level: Implications for the RELIEF Flow Tagging Technique

The vibrational relaxation of ground-state molecular oxygen (O2, X(sup 3)Sigma(sup -)(sub g)) has been observed, following stimulated Raman excitation to the first excited vibrational level (v=1). Time delayed laser-induced fluorescence probing of the ro-vibrational population distribution was used to examine the temporal relaxation behavior. In the presence of water vapor, the relaxation process is rapid, and is dominated by near-resonant vibrational energy exchange between the v=1 level of O2 and the n2 bending mode of H2O. In the absence of H2O, reequilibration proceeds via homogeneous vibrational energy transfer, in which a collision between two v=1 O2 molecules leaves one molecule in the v=2 state and the other in the v=0 state. Subsequent collisions between molecules in v=1 and v>1 result in continued transfer of population up the vibrational ladder. The implications of these results for the RELIEF flow tagging technique are discussed.

Diskin, Glenn S.↗

A radiative transfer model for remote sensing of laser induced fluorescence of phytoplankton in non-homogeneous turbid water

A radiative transfer computer model was developed to characterize the total flux of chlorophyll a fluoresced or backscattered photons when laser radiation is incident on turbid water that contains a non-homogeneous suspension of inorganic sediments and phytoplankton. The radiative transfer model is based on the Monte Carlo technique and assumes that: (1) the aquatic medium can be represented by a stratified concentration profile; and (2) that appropriate optical parameters can be defined for each layer. The model was designed to minimize the required computer resources and run time. Results are presented for an anacystis marinus culture.

Venable, D. D.↗

Iodine monofluoride emission spectrum and formation kinetics in electron-beam-produced plasmas

The observation of intense blue-green spontaneous emission attributed to IF from electron-beam-excited Ar/CF3I/NF3 gas mixtures is reported. Intense emission from a structured band centered at a wavelength of 484 nm was observed when mixtures of 2000-4000 Torr AR (or He or Ne), 3 Torr CF3I and 1 Torr NF3 (or F2) were irradiated with a 3-nsec FWHM electron beam. Analysis of ICl and IBr spectra, which the present spectrum closely resembles, indicates that the 484-nm emission originates from the E to A 3 pi 1 transition of IF. Examination of the time dependence of metastable IF and I2 emission reveals that the IF (E) level is formed primarily by excitation transfer from metastable I(4P) states. The fluorescence efficiency of the E-A transition and the radiative lifetime of the metastable IF (E) state are estimated to be approximately 6% and 15 nsec, respectively, and it is suggested that metastable IF is an attractive candidate for a blue-green laser.

Hutchison, S. B.↗

Satellite Laser Ranging operations

Satellite Laser Ranging (SLR) is currently providing precision orbit determination for measurements of: 1) Ocean surface topography from satellite borne radar altimetry, 2) Spatial and temporal variations of the gravity field, 3) Earth and ocean tides, 4) Plate tectonic and regional deformation, 5) Post-glacial uplift and subsidence, 6) Variations in the Earth's center-of-mass, and 7) Variations in Earth rotation. SLR also supports specialized programs in time transfer and classical geodetic positioning, and will soon provide precision ranging to support experiments in relativity.

Pearlman, Michael R.↗

Variability in Mt. Sharp Group Bedrock as Seen By ChemCam Passive and Active Spectra

The Curiosity rover landed in Gale crater in August 2012 and has since been travelling up the central sedimentary mound known as Mt. Sharp. The ChemCam instrument on Curiosity was designed primarily for the use of Laser Induced Breakdown Spectroscopy (LIBS), where a laser ablates a small amount of material from the target and the spectrum of the resulting plasma yields elemental abundance data. ChemCam’s three spectrometers range from 240-905 nm and can also take passive spectra (without the use of the laser). The spectral range ChemCam passive spectra observe is sensitive to charge-transfer and crystal field absorptions related to iron-bearing minerals. In the first 2934 sols of Curiosity’s mission, 9,400 passive spectra were taken of bedrock targets in Mt. Sharp’s Murray and Carolyn Shoemaker formations. We examine these spectra using spectral slope/ratio and band depth calculations as well as Principal Component Analysis (PCA). For the first time, paired passive spectra and LIBS elemental abundances are compared on a large scale. Finally, CheMin data are compared to ChemCam passive observations to understand sources of spectral variability.

H T Manelski↗

Video-Camera-Based Position-Measuring System

A prototype optoelectronic system measures the three-dimensional relative coordinates of objects of interest or of targets affixed to objects of interest in a workspace. The system includes a charge-coupled-device video camera mounted in a known position and orientation in the workspace, a frame grabber, and a personal computer running image-data-processing software. Relative to conventional optical surveying equipment, this system can be built and operated at much lower cost; however, it is less accurate. It is also much easier to operate than are conventional instrumentation systems. In addition, there is no need to establish a coordinate system through cooperative action by a team of surveyors. The system operates in real time at around 30 frames per second (limited mostly by the frame rate of the camera). It continuously tracks targets as long as they remain in the field of the camera. In this respect, it emulates more expensive, elaborate laser tracking equipment that costs of the order of 100 times as much. Unlike laser tracking equipment, this system does not pose a hazard of laser exposure. Images acquired by the camera are digitized and processed to extract all valid targets in the field of view. The three-dimensional coordinates (x, y, and z) of each target are computed from the pixel coordinates of the targets in the images to accuracy of the order of millimeters over distances of the orders of meters. The system was originally intended specifically for real-time position measurement of payload transfers from payload canisters into the payload bay of the Space Shuttle Orbiters (see Figure 1). The system may be easily adapted to other applications that involve similar coordinate-measuring requirements. Examples of such applications include manufacturing, construction, preliminary approximate land surveying, and aerial surveying. For some applications with rectangular symmetry, it is feasible and desirable to attach a target composed of black and white squares to an object of interest (see Figure 2). For other situations, where circular symmetry is more desirable, circular targets also can be created. Such a target can readily be generated and modified by use of commercially available software and printed by use of a standard office printer. All three relative coordinates (x, y, and z) of each target can be determined by processing the video image of the target. Because of the unique design of corresponding image-processing filters and targets, the vision-based position- measurement system is extremely robust and tolerant of widely varying fields of view, lighting conditions, and varying background imagery.

Lane, John↗

The construction of a highly transportable laser ranging station

The technology of the transportable Laser Ranging Station (TLRS) used in crustal dynamics studies was examined. The TLRS used a single photoelectron beam of limited energy density returned from the Laser Geodynamic Satellite (LAGEOS). Calibration was accomplished by the diversion of a small portion of the outgoing beam attenuated to the same level as the satellite return. Timing for the system was based on a self calibrating Ortec TD811, 100 picosec time interval device. The system was contained in a modified, single chassis recreational vehicle that allowed rapid deployment. The TLRS system was only airmobile on the largest transport aircraft. A 30 cm simple plano/concave transfer lens telescope aided in beam direction. The TLRS system fulfills the need for an accurate method of obtaining range measurements to the LAGEOS satellite incorporated in a mobile, air transportable, and economical configuration.

Source record↗

Communications, Signal Processing, and Telemetering Research Program Review

A Communications, Signal Processing, and Telemetering Research Program Review was held on February 23, 1999. Research conducted under the grant was presented and reviewed, for progress, and for possible technology transfers. The research reviewed was in the following areas: (1) Bandwidth-efficient Modulation and nonlinear equalization; (2) Investigation of an architecture for parallel signal processing applicable to communications problems; (3)Coded partial response over satellites; (4) synchronization at Low SNR; (5) Serial concatenated convolutional codes and some implementation issues on high rate turbo codes; (6) Flight experiments; (7) Real time doppler tracking; (8) Space protocol testing; (9) Lightweight optical communications without carrying a laser in space. The presentations are given by the graduate students who performed the research.

Source record↗

A high speed buffer for LV data acquisition

The laser velocimeter (autocovariance) buffer interface is a data acquisition subsystem designed specifically for the acquisition of data from a laser velocimeter. The subsystem acquires data from up to six laser velocimeter components in parallel, measures the times between successive data points for each of the components, establishes and maintains a coincident condition between any two or three components, and acquires data from other instrumentation systems simultaneously with the laser velocimeter data points. The subsystem is designed to control the entire data acquisition process based on initial setup parameters obtained from a host computer and to be independent of the computer during the acquisition. On completion of the acquisition cycle, the interface transfers the contents of its memory to the host under direction of the host via a single 16-bit parallel DMA channel.

Cavone, Angelo A.↗

Petabyte mass memory system using the Newell Opticel(TM)

A random access system is proposed for digital storage and retrieval of up to a Petabyte of user data. The system is comprised of stacked memory modules using laser heads writing to an optical medium, in a new shirt-pocket-sized optical storage device called the Opticel. The Opticel described is a completely sealed 'black box' in which an optical medium is accelerated and driven at very high rates to accommodate the desired transfer rates, yet in such a manner that wear is virtually eliminated. It essentially emulates a disk, but with storage area up to several orders of magnitude higher. Access time to the first bit can range from a few milliseconds to a fraction of a second, with time to the last bit within a fraction of a second to a few seconds. The actual times are dependent on the capacity of each Opticel, which ranges from 72 Gigabytes to 1.25 Terabytes. Data transfer rate is limited strictly by the head and electronics, and is 15 Megabits per second in the first version. Independent parallel write/read access to each Opticel is provided using dedicated drives and heads. A Petabyte based on the present Opticel and drive design would occupy 120 cubic feet on a footprint of 45 square feet; with further development, it could occupy as little as 9 cubic feet.

Newell, Chester W.↗

Enhanced Boiling on Micro-Configured Composite Surfaces Under Microgravity Conditions

Two experimental setups: High Heat Flux Pool Boiling Setup and Optical system of Measuring Contact Angle and Spreading Parameters were established and a series of experiments was conducted. The experimental work on the nucleate boiling performance of both Freon-113 and water on the composite surfaces has been finished and the results show that the composite surface with 25% volume fraction of graphite fibers in the copper matrix has the best enhancing performance. Stronger enhancement was obtained for water compared to Freon-113. The wall superheat initiating boiling was reduced 40% and 35% and the heat flux of the nucleate boiling was augmented up to ten times and 6.7 times, respectively. A bubble departure model has been presented to explain the enhancement mechanism of the boiling heat transfer on the composite surfaces. A powerful optical method to measure contact angle and spreading parameters of liquids on solid surfaces, including both transparent and non-transparent substrates, has been developed and successfully used in the measurements for various liquid-solid systems. The experimental work on identification of profiles near three-phase line by laser shadowgraphy method has been finished and the characteristics of the three-phase line for different liquid-solid systems were unveiled, which is very important to understand the mechanism of boiling under microgravity conditions. The four basic patterns of sessile profile were discovered through caustics and caustic-diffraction analysis by applying wave theory in shadowgraphy technology, which contributes to clearly explain the different characteristics of wetting and spreading of various liquids on a solid surface, and therefore to further understand the bubble departure mechanisms. A new working pattern of heat pipes using working fluids with positive surface-tension gradient against temperature was discovered and analyzed, and then the new heat pipe systems using this kind of working fluids have been presented. Two patent devices, i.e. Shadowgraphic Method to Measure Properties of Sessile Drops and Heat Pipe Systems Using New Working Fluids, have been developed; the former has been approved by The United States Patent & Trademark Office and the latter is being examined.

Source record↗

Time-resolved double-probe study in a He-Hg afterglow plasma

An experimental double-probe technique is described which allows the He(+) ion density to be measured directly as a function of time in the afterglow of a helium-metal-vapor discharge. As an application example, two CW laser transitions of the He-Hg(+) laser at 6150 and 7944 A are considered which both arise from excited 7p (2) P terms of Hg II. The time-resolved double-probe technique is used to measure the destruction rate of the He(+) ion density, which is then compared with the spontaneous-emission decay rate for 7p (2) P terms of Hg II. The results obtained show unambiguously and directly that the dominant excitation process for the two transitions considered is a charge-transfer collisional reaction of the form He(+) plus Hg yields He plus metastable Hg(+) plus the energy defect for this reaction. It is noted that the time-resolved double-probe technique may provide a simple method for measuring ion mobilities in a multi-ion plasma.

Shay, T.↗

Detailed investigation of a vaporising fuel spray. Part 1: Experimental investigation of time averaged spray

A laser tomographic light scattering technique provides rapid and accurate high resolution measurements of droplet sizes, concentrations, and vaporization. Measurements using a computer interfaced thermocouple are presented and it is found that the potential exists for separating gas and liquid temperature measurements and diagnosing local spray density by in situ analysis of the response characteristics of the thermocouple. The thermocouple technique provides a convenient means for measuring mean gas velocity in both hot and cold two phase flows. The experimental spray is axisymmetric and has carefully controlled initial and boundary conditions. The flow is designed to give relatively insignificant transfer of momentum and mass from spray to air flow. The effects of (1) size-dependent droplet dispersion by the turbulence, (2) the initial spatial segregation of droplet sizes during atomization, and (3) the interaction between droplets and coherent large eddies are diagnosed.

Yule, A. J.↗

Comparison of spectroscopic properties of Tm and Ho in YAG and YLF crystals

The paper compares the cross-relaxation, energy transfer and loss processes in Tm- and Ho-doped YAG and YLF as a function of temperature, Tm concentration, and excitation power. Significant differences in the behavior of Tm and Tm,Ho in YAG and YLF crystals were found. The cross-relaxation rates of Tm(6 pct) are faster in YLF (about 5 microsec) than YAG (about 10 microsec). The energy transfer rates between Tm and Ho are faster in YLF than YAG. The time it takes for the maximum intensity of 1.7-micron emission to drop 10 percent is 25 microsec for YLF:Tm(6 pct),Ho(0.6 pct) and 65 microsec YAG:Tm(6 pct),Ho(0.5 pct). The losses occurring with increasing pump power for 2.1-micron emission of the above samples are 30 percent less in YLF than YAG. These qualitative differences point to YLF as a valuable 2-micron laser host material.

Armagan, G.↗