Search NASA⌕ Search

SEARCH · Search NASA

Results for “Latent control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Maintaining the Body's Immune System: Incidence of Latent Virus Shedding During Space Flight

Your body protects you from illness with its own security system - the immune system. This system keeps illness at bay not only by mounting a defense against foreign organisms, but also by controlling the population of bacteria and viruses that normally live in your body. But there's no need to panic: certain microbes can actually exist in your body without causing illness. Some bacteria are even beneficial - like the E. coli in the large intestine that are an important source of vitamin K. While viruses are not exactly considered beneficial, they can also inhabit the human body without causing immediate harm or infection. A good example is the herpes simplex virus type 1 (HSV1), more commonly known as cold sores or fever blisters. This virus infects 70 to 80 percent of all adults but remains latent much of the time. While latent, the virus within cells remains dormant. Activation of the dormant virus causes it to make copies of itself (known as replication) constantly detectable in body fluids such as urine or saliva in a process called shedding. When a person becomes sick or stressed, however, this weakened condition allows the virus to reactivate and multiply. These elevated levels may be enough to produce symptoms, but shedding can also occur without symptoms. This ability to shed without showing signs of infection, or asymptomatic shedding, is of great interest, as it increases the chances of infecting others. The stresses associated with space flight - adapting to microgravity, isolation from family and friends, living and working in a confined space, sleep deprivation, and busy schedules, to name but a few - may weaken astronauts' immune systems, leaving them at greater risk of viral reactivation. Members of the STS-107 crew will participate in this experiment, Incidence of Latent Viral Shedding in Space Flight, to help scientists understand how reactivation works in space, and at what level replication reaches before symptoms begin to show. This study also promises more insight into the behavior of the larger virus family, herpesvirus, which will help us understand how to prevent infection in populations on Earth and reactivation in those already infected.

Pierson, Duane↗

Learning and Fast Adaptation for Grid Emergency Control via Deep Meta Reinforcement Learning

As power systems are undergoing a significant transformation with more uncertainties, less inertia and closer to operation limits, there is increasing risk of large outages. Thus, there is an imperative need to enhance grid emergency control to maintain system reliability and security. Towards this end, great progress has been made in developing deep reinforcement learning (DRL) based grid control solutions in recent years. However, existing DRL-based solutions have two main limitations: 1) they cannot handle well with a wide range of grid operation conditions, system parameters, and contingencies; 2) they generally lack the ability to fast adapt to new grid operation conditions, system parameters, and contingencies, limiting their applicability for real-world applications. Here, in this paper, we mitigate these limitations by developing a novel deep meta-reinforcement learning (DMRL) algorithm. The DMRL combines the meta strategy optimization together with DRL, and trains policies modulated by a latent space that can quickly adapt to new scenarios. We test the developed DMRL algorithm on the IEEE 300-bus system. We demonstrate fast adaptation of the meta-trained DRL polices with latent variables to new operating conditions and scenarios using the proposed method, which achieves superior performance compared to the state-of-the-art DRL and model predictive control (MPC) methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The role of the epidermis and cortex in gravitropic curvature of maize roots

In order to determine the role of the epidermis and cortex in gravitropic curvature of seedling roots of maize (Zea mays L. cv. Merit), the cortex on the two opposite flanks was removed from the meristem through the growing zone; gravitropic curvature was measured with the roots oriented horizontally with the cut flanks either on the upper and lower side, or on the lateral sides as a wound control. Curvature was slower in both these treatments (53 degrees in 5 h) than in intact roots (82 degrees), but there was no difference between the two orientations in extent and rate of curvature, nor in the latent time, showing that epidermis and cortex were not the site of action of the growth-regulating signal. The amount of cortex removed made no difference in the extent of curvature. Curvature was eliminated when the endodermis was damaged, raising the possibility that the endodermis or the stele-cortex interface controls gravitropic curvature in roots. The elongation rate of roots from which just the epidermis had been peeled was reduced by 0.01 mM auxin (indole-3-acetic acid) from 0.42 to 0.27 mm h-1, contradicting the hypothesis that only the epidermis responds to changes in auxin activity during gravistimulation. These observations indicate that gravitropic curvature in maize roots is not driven by differential cortical cell enlargement, and that movement of growth regulator(s) from the tip to the elongating zone is unlikely to occur in the cortex.

NASA Program Space Biology↗

Development, Testing, and Failure Mechanisms of a Replicative Ice Phase Change Material Heat Exchanger

Phase change materials (PCM) may be useful for thermal control systems that involve cyclical heat loads or cyclical thermal environments such as Low Earth Orbit (LEO) and Low Lunar Orbit (LLO). Thermal energy can be stored in the PCM during peak heat loads or in adverse thermal environments. The stored thermal energy can then be released later during minimum heat loads or in more favorable thermal environments. One advantage that PCM s have over evaporators in this scenario is that they do not use a consumable. Wax PCM units have been baselined for the Orion thermal control system and also provide risk mitigation for the Altair Lander. However, the use of water as a PCM has the potential for significant mass reduction since the latent heat of formation of water is approximately 70% greater than that of wax. One of the potential drawbacks of using ice as a PCM is its potential to rupture its container as water expands upon freezing. In order to develop a space qualified ice PCM heat exchanger, failure mechanisms must first be understood. Therefore, a methodical experimental investigation has been undertaken to demonstrate and document specific failure mechanisms due to ice expansion in the PCM. An ice PCM heat exchanger that replicates the thermal energy storage capacity of an existing wax PCM unit was fabricated and tested. Additionally, methods for controlling void location in order to reduce the risk of damage due to ice expansion are investigated. This paper presents the results to date of this investigation.

Leimkuehler, Thomas O.↗

Development, Testing, and Failure Mechanisms of a Replicative Ice Phase Change Material Heat Exchanger

Phase change materials (PCM) may be useful for thermal control systems that involve cyclical heat loads or cyclical thermal environments such as Low Earth Orbit (LEO) and Low Lunar Orbit (LLO). Thermal energy can be stored in the PCM during peak heat loads or in adverse thermal environments. The stored thermal energy can then be released later during minimum heat loads or in more favorable thermal environments. One advantage that PCM's have over evaporators in this scenario is that they do not use a consumable. Wax PCM units have been baselined for the Orion thermal control system and also provide risk mitigation for the Altair Lander. However, the use of water as a PCM has the potential for significant mass reduction since the latent heat of formation of water is approximately 70% greater than that of wax. One of the potential drawbacks of using ice as a PCM is its potential to rupture its container as water expands upon freezing. In order to develop a space qualified ice PCM heat exchanger, failure mechanisms must first be understood. Therefore, a methodical experimental investigation has been undertaken to demonstrate and document specific failure mechanisms due to ice expansion in the PCM. An ice PCM heat exchanger that replicates the thermal energy storage capacity of an existing wax PCM unit was fabricated and tested. Additionally, methods for controlling void location in order to reduce the risk of damage due to ice expansion are investigated. This paper presents the results to date of this investigation. Nomenclature

Leimkuehler, Thomas O.↗

Biosphere/atmosphere Interactions

Vegetation influences the energy, mass and momentum exchange between land-surface and atmosphere and, in that way, may significantly affect weather and climate. The morphology and physiology of the vegetation determine the surface albedo, precipitation interception and interception loss, stomatal control of transpiration, moisture storage in the root zone and, through the vegetation roughness height, the aerodynamic resistance to the transfers of latent and sensible heat and momentum between land-surface and atmosphere. That the albedo and soil moisture have a large influence on the atmospheric circulation and rainfall was demonstrated in sensitivity experiments with general circulation models. Moreover, through its effect on the convergence of the horizontal water vapor transport in the planetary boundary layer, the surface roughness height has a large influence on rainfall.

Mintz, Y.↗

Measurement and analysis of workload effects on fault latency in real-time systems

The authors demonstrate the need to address fault latency in highly reliable real-time control computer systems. It is noted that the effectiveness of all known recovery mechanisms is greatly reduced in the presence of multiple latent faults. The presence of multiple latent faults increases the possibility of multiple errors, which could result in coverage failure. The authors present experimental evidence indicating that the duration of fault latency is dependent on workload. A synthetic workload generator is used to vary the workload, and a hardware fault injector is applied to inject transient faults of varying durations. This method makes it possible to derive the distribution of fault latency duration. Experimental results obtained from the fault-tolerant multiprocessor at the NASA Airlab are presented and discussed.

Woodbury, Michael H.↗

Detection and quantification of Epstein-Barr virus EBER1 in EBV-infected cells by fluorescent in situ hybridization and flow cytometry

A rapid and highly sensitive fluorescent in situ hybridization (FISH) assay was developed to detect Epstein Barr virus (EBV)-infected cells in peripheral blood. Multiple fluorescein-labeled antisense oligonucleotide probes were designed to hybridize to the EBER1 transcript, which is highly expressed in latently infected cells. After a rapid (30 min) hybridization, the cells were analyzed by flow cytometry. EBER1 was detected in several positive control cell lines that have variable numbers of EBV genome copies. No EBER1 was detected in two known EBV-negative cell lines. Northern blot analyses confirmed the presence and quantity of EBER1 transcripts in each cell line. This method was used to quantify the number of EBV-infected cells in peripheral blood from a patient with chronic mononucleosis. These results indicate that EBV-infected cells can be detected at the single cell level, and that this assay can be used to quantify the number of EBV-infected cells in clinical samples.

NASA Discipline Regulatory Physiology↗

Evaporative Cooling and Dehumidification Garment for Portable Life Support Systems

This paper describes the design and development of an innovative thermal and humidity control system for future space suits. The system comprises an evaporation cooling and dehumidification garment (ECDG) and a lithium chloride absorber radiator (LCAR). The ECDG absorbs heat and water vapor from inside the suit pressure garment, while the LCAR rejects heat to space without venting water vapor. The ECDG is built from thin, flexible patches with coversheets made of non-porous, water-permeable membranes that -enclose arrays of vapor flow passages. Water vapor from inside the spacesuit diffuses across the water permeable membranes, enters the vapor flow channels, and then flows to the LCAR, thus dehumidifying the internal volume of the space suit pressure garment. Additional water evaporation inside the ECDG provides cooling for sensible heat loads. -The heat released from condensation and absorption in the LCAR is rejected to the environment by thermal radiation. We have assembled lightweight and flexible ECDG pouches from prototypical materials and measured their performance in a series of separate effects tests under well-controlled, prototypical conditions. Sweating hot plate tests at typical space suit pressures show that ECDG pouches can absorb over 60 W/ft of latent heat and 20 W/ft of sensible heat from the pressure garment environment. These results are in good agreement with the predictions of our analysis models.

Izenson, Michael↗

On the predictability of turbulent fluxes from land: PLUMBER2 MIP experimental description and preliminary results

Accurate representation of the turbulent exchange of carbon, water, and heat between the land surface and the atmosphere is critical for modelling global energy, water, and carbon cycles in both future climate projections and weather forecasts. Evaluation of models' ability to do this is performed in a wide range of simulation environments, often without explicit consideration of the degree of observational constraint or uncertainty and typically without quantification of benchmark performance expectations. We describe a Model Intercomparison Project (MIP) that attempts to resolve these shortcomings, comparing the surface turbulent heat flux predictions of around 20 different land models provided with in situ meteorological forcing evaluated with measured surface fluxes using quality-controlled data from 170 eddy-covariance-based flux tower sites. Predictions from seven out-of-sample empirical models are used to quantify the information available to land models in their forcing data and so the potential for land model performance improvement. Sites with unusual behaviour, complicated processes, poor data quality, or uncommon flux magnitude are more difficult to predict for both mechanistic and empirical models, providing a means of fairer assessment of land model performance. When examining observational uncertainty, model performance does not appear to improve in low-turbulence periods or with energy-balance-corrected flux tower data, and indeed some results raise questions about whether the energy balance correction process itself is appropriate. In all cases the results are broadly consistent, with simple out-of-sample empirical models, including linear regression, comfortably outperforming mechanistic land models. In all but two cases, latent heat flux and net ecosystem exchange of CO 2 are better predicted by land models than sensible heat flux, despite it seeming to have fewer physical controlling processes. Land models that are implemented in Earth system models also appear to perform notably better than stand-alone ecosystem (including demographic) models, at least in terms of the fluxes examined here. The approach we outline enables isolation of the locations and conditions under which model developers can know that a land model can improve, allowing information pathways and discrete parameterisations in models to be identified and targeted for future model development.

54 ENVIRONMENTAL SCIENCES↗

On the validity and limitations of 1D model for heat and mass transfer performance evaluation in a multilayer binder-free desiccant dehumidifier: isothermal dehumidification with internal cooling

Efficient humidity control is essential for maintaining indoor thermal comfort, yet conventional vapor-compression-based dehumidifiers are energy-intensive. Employing separate sensible and latent cooling through desiccant-coated heat exchangers (DCHEs) combined with evaporative coolers offers energy savings of up to 80 % compared to conventional systems. However, the dehumidification performance of DCHEs remains limited due to the use of polymer binders for coating desiccant materials onto heat exchange surfaces. In our previous study, we developed a multilayer fixed-bed binder-free desiccant dehumidifier (MFBDD) that demonstrated high dehumidification capacity and low pressure drop compared to rotary desiccant wheels. Nevertheless, its potential for further enhancement through internal cooling and the use of step-shaped adsorption isotherms has not been explored. In this study, a physics-based one-dimensional (1D) transient model is developed and validated to capture the coupled heat and mass transfer processes in the MFBDD and extended to simulate internal cooling using a high-capacity composite metal–organic framework, MIL-101/GO-6 (water uptake ≈1.6 g/g within 35–47 % RH). The model enables detailed analysis of local air and bed temperature dynamics and quantifies how internal cooling affects the dehumidification performance under a wide range of operating conditions. Results show that integrating internal cooling and using MIL-101/GO-6 enhance mass adsorbed, moisture removal capacity, and dehumidification effectiveness by 50 %–99 % compared with the M.S. Gel baseline. The study further reveals that achieving near-isothermal operation requires simultaneous enhancement of the convective heat transfer coefficient and heat exchange surface area. In conclusion, this work provides the first detailed physical insight into the interplay between internal cooling and step-shaped isotherms in a binder-free desiccant device and establishes a validated modeling framework for scaling up and system-level performance evaluation of next-generation energy-efficient dehumidification systems.

Heat and mass transfer↗

Nonlinear dynamics of global atmospheric and Earth-system processes

General Circulation Model (GCM) studies of the atmospheric response to change boundary conditions are discussed. Results are reported on an extensive series of numerical studies based on the National Center for Atmospheric Research (NCAR) Community Climate Model (CCM) general circulation model. In these studies the authors determined the response to systematic changes in atmospheric CO2 ranging from 100 to 1000 ppm; to changes in the prescribed sea surface temperature (SST) in the Gulf of Mexico, such as occurred during the deglaciation phase of the last ice age; to changes in soil moisture over North America; and to changes in sea ice extent in the Southern Hemisphere. Study results show that the response of surface temperature and other variables is nearly logarithmic, with lower levels of CO2 implying greater sensitivity of the atmospheric state to changes in CO2. It was found that the surface temperature of the Gulf of Mexico exerts considerable control over the storm track and behavior of storm systems over the North Atlantic through its influence on evaporation and the source of latent heat. It was found that reductions in soil moisture can play a significant role in amplifying and maintaining North American drought, particularly when a negative soil moisture anomaly prevails late in the spring.

Saltzman, Barry↗

Meteorological Variables and Energy Fluxes at the Pumphouse Site, Crested Butte, CO 2017-2019

This data contains output from the pumphouse eddy covariance tower that includes shortwave radiation, longwave radiation, net radiation, air temperature, relative humidity, as well as sensible, latent, and ground heat fluxes. Also included is calculated evapotranspiration from the latent heat flux and the latent heat of vaporization. All data are on a daily timestep and displayed in Mountain Time. The data has been processed, and Quality Assurance / Quality Control (QA/QC) was done, but any daily gaps in the data have not been filled in. This research was funded by the Department of Energy and performed as part of the Watershed Function Scientific Focus Area. This research aimed to constrain evapotranspiration in a high-elevation catchment.The dataset includes one comma-separated values (CSV) data file (EddyCovariance_MeteorlogicalVariables_CrestedButtePumphouse.csv). Additionally, three metadata CSV files are included: (1) location metadata file (locations.csv), which contains location metadata and coordinates; (2) a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata; and (3) a data dictionary (dd.csv) file that contains column/row headers used throughout the files along with a definition, units, and data type.This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES↗

Incidence of Latent Virus Shedding during Space Flight

Measurements of immune parameters of both cellular and innate immunity indicate alterations in immune function in astronauts. Immune changes are due to stress and perhaps other factors associated with launch, flight, and landing phases. Medical relevance of observed changes is not known. The reactivation of latent viruses has been identified as an important in vivo indicator of clinically relevant immune changes. The polymerase chain reaction (PCR) was used to detect the presence of specific viral DNA in body fluids. Initial studies demonstrated Epstein-Barr virus (EBV) reactivation during all 3 mission phases. EBV is shed in saliva following reactivation from B-cells. Incidence of EBV in saliva was higher than control subjects during all 3 mission phases. However, quantitative PCR revealed 10-fold higher levels of EBV DNA present in saliva collected during flight than found in pre- and post flight specimens. To determine if other latent viruses showed similar effects, cytomegalovirus (CMV), another herpes virus, shed in urine following reactivation was studied. A very low incidence (less than 2%) of CMV in urine is found in healthy, lowstressed individuals. However, 25-50% of astronauts shed CMV in their urine before, during, or after flight. Our studies are now focused on varicella-zoster virus (VZV), the etiological agent of chicken-pox during childhood and shingles later in life. We demonstrated reactivation of VZV and shedding of the virus during and after spaceflight in saliva of astronauts with no sign of active infection or symptoms. The maximum shedding of VZV occurred during the flight phase and diminishes rapidly during the first five days after landing. We have utilized the same PCR assay for VZV in a clinical study of shingles patients. Generally, shingles patients shed much more VZV in saliva than astronauts. However, the VZV levels in astronauts overlap with the lower range of VZV numbers in shingles patients. Saliva from shingles patients and astronauts were cultured and infectious VZV was recovered from both groups. We have concluded that multiple latent viruses do reactivate before, during, and after spaceflight and serve as very sensitive indicators for diminished cellular immunity. Future plans will be focused on the clinical risks posed by the reactivation of these viruses. Initial efforts will determine the effect of longer missions on the International Space Station on the reactivation patterns of these viruses.

Mehta, Satish K.↗

Novel Representation of Leaf Phenology Improves Simulation of Amazonian Evergreen Forest Photosynthesis in a Land Surface Model

Leaf phenology in the humid tropics largely regulates the seasonality of forest carbon and water exchange. However, it is inadequately represented in most global land surface models due to limited understanding of its controls. Based on intensive field studies at four Amazonian evergreen forests, we propose a novel, quantitative representation of tropical forest leaf phenology, which links multiple environmental variables with the seasonality of new leaf production and old leaf litterfall. The new phenology simulates higher rates of leaf turnover (new leaves replacing old leaves) in dry seasons with more sunlight, which is then implemented in ORCHIDEE, together with recent findings of ontogeny-associated photosynthetic capacity, and is evaluated against ground-based measurements of leaf phenology (canopy leaf area index and litterfall), eddy covariance fluxes (photosynthesis and latent heat), and carbon allocations from field observations. Results show the periodical cycles of solar radiation and vapor pressure deficit are the two most important environmental variables that are empirically related to new leaf production and old leaf abscission in tropical evergreen forests. The model with new representation of leaf phenology captures the seasonality of canopy photosynthesis at three out of four sites, as well as the seasonality of litterfall, latent heat, and light use efficiency of photosynthesis at all tested sites, and improves the seasonality of carbon allocations to leaves, roots, and sapwoods. This study advances understanding of the environmental controls on tropical leaf phenology and offers an improved modeling tool for gridded simulations of interannual CO 2 and water fluxes in the tropics.

54 ENVIRONMENTAL SCIENCES↗

Flight prototype CO2 and humidity control system

A regenerable CO2 and humidity control system is presently being developed for potential use on shuttle as an alternative to the baseline lithium hydroxide system. The system utilizes a sorbent material (designated HS-C) to adsorb CO2 and the latent heat load from the cabin atmosphere and desorb the CO2 and water vapor overboard when exposed to a space vacuum, thus reducing the overall vehicle heat rejection load. Continuous operation is achieved by utilizing two beds which are alternatively cycled between adsorption and desorption. The HS-C material process was verified. Design concepts for the auxiliary components for the HS-C prototype system were generated. Performance testing verified system effectiveness in controlling CO2 partial pressure and humidity.

Rudy, K. M.↗

Modular Hydronic Room Conditioning System (CRADA NFE-24-10120 Final Report)

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin-tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular Hydronic Room Conditioning System

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗