Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laue diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Unnamed Pt(Cu 0.67 Sn 0.33 ) from the Bolshoy Khailyk River, Western Sayans, Russia, and a Review of Related Compounds and Solid Solutions

We describe a potentially new species of a platinum cupride–stannide mineral (PCSM) of composition Pt(Cu 0.67 Sn 0.33 ). It occurs in a placer deposit in the River Bolshoy Khailyk, southern Krasnoyarskiy kray, Russia. A synthetic equivalent of PCSM was obtained and characterized. The PCSM occurs as anhedral or subhedral grains up to 15 μm × 30 μm in association with various platinum-group minerals, Rh–Co-rich pentlandite and magnetite, all hosted by a placer grain of Cu–Au–Pt alloy. Synchrotron micro-Laue diffraction studies indicate that the PCSM mineral is tetragonal and belongs to the inferred space-group P4/mmm (#123). Its unit-cell parameters are a = 2.838 (3) Å, c = 3.650 (4) Å, and V = 29.40 (10) Å 3 , and Z = 1. The c:a ratio calculated from the unit-cell parameters is 1.286. These characteristics are in good agreement with those obtained for specimens of synthetic Pt(Cu 0.67 Sn 0.33 ). A review on related minerals and unnamed phases is provided to outline compositional variations and extents of solid solutions in the relevant systems PtNi–PtFe–PtCu, PdCu–PdHg–PdAu, PdHg–PtHg, and AuCu–PtCu. The PCSM-bearing mineralization appears to be related genetically with an ophiolitic source-rock of the Aktovrakskiy complex of the western Sayans. The unnamed phase likely crystallized from microvolumes of a highly fractionated melt rich in Cu and Sn.

36 MATERIALS SCIENCE↗

Growth of ZnTe by Physical Vapor Transport and Traveling Heater Method

ZnTe crystals were grown by horizontal physical vapor transport (PVT) and a Te-solution vertical traveling heater method (THM). The grown crystals were examined by X-ray Laue diffraction technique and Hall measurements to determine the growth orientation and the electrical properties of the crystals. They were also characterized by low temperature infrared (IR) absorption measurements. Several sets of distinct peaks were observed in the IR absorption spectra for the THM samples and were identified as resulting from CU(2+) impurities. Similar measurements on vapor grown ZnTe showed featureless absorption spectra. Chemical analyses were carried out to measure the impurity content in various ZnTe samples and synchrotron radiation topography was used to Study crystalline microstructure of the (111) ZnTe single crystals grown by PVT.

Su, Ching-Hua↗

Characterization of 4H <000-1> Silicon Carbide Films Grown by Solvent-Laser Heated Floating Zone

Commercially available bulk silicon carbide (SiC) has a high number (>2000/sq cm) of screw dislocations (SD) that have been linked to degradation of high-field power device electrical performance properties. Researchers at the NASA Glenn Research Center have proposed a method to mass-produce significantly higher quality bulk SiC. In order for this bulk growth method to become reality, growth of long single crystal SiC fibers must first be achieved. Therefore, a new growth method, Solvent-Laser Heated Floating Zone (Solvent-LHFZ), has been implemented. While some of the initial Solvent-LHFZ results have recently been reported, this paper focuses on further characterization of grown crystals and their growth fronts. To this end, secondary ion mass spectroscopy (SIMS) depth profiles, cross section analysis by focused ion beam (FIB) milling and mechanical polishing, and orientation and structural characterization by x-ray transmission Laue diffraction patterns and x-ray topography were used. Results paint a picture of a chaotic growth front, with Fe incorporation dependant on C concentration.

Woodworth, Andrew, A↗

2D and 3D X-Ray Structural Microscopy Using Submicron-Resolution Laue Microdiffraction

We have developed a scanning, polychromatic x-ray microscopy technique with submicron spatial resolution at the Advanced Photon Source. In this technique, white undulator radiation is focused to submicron diameter using elliptical mirrors. Laue diffraction patterns scattered from the sample are collected with an area detector and then analyzed to obtain the local crystal structure, lattice orientation, and strain tensor. These new microdiffraction capabilities have enabled both 2D and 3D structural studies of materials on mesoscopic length-scales of tenths-to-hundreds of microns. For thin samples such as deposited films, 2D structural maps are obtained by step-scanning the area of interest. For example, 2D x-ray microscopy has been applied in studies of the epitaxial growth of oxide films. For bulk samples, a 3D differential-aperture x-ray microscopy technique has been developed that yields the full diffraction information from each submicron volume element. The capabilities of 3D x-ray microscopy are demonstrated here with measurements of grain orientations and grain boundary motion in polycrystalline aluminum during 3D thermal grain growth. X-ray microscopy provides the needed, direct link between the experimentally measured 3D microstructural evolution and the results of theory and modeling of materials processes on mesoscopic length scales.

36 MATERIALS SCIENCE↗

INTERFACE RESIDUAL STRESSES IN DENTAL ZIRCONIA USING LAUE MICRO-DIFFRACTION

Due to their aesthetic value and high compressive strength, dentists have recently employed ceramics for restoration materials. Among the ceramic materials, zirconia provides high toughness and crack resistant characteristics. Residual stresses develop in processing due to factors including grain anisotropy and thermal coefficient mismatch. In the present study, polychromatic X-ray (Laue) micro-diffraction provided grain orientation and residual stresses on a clinically relevant zirconia model ceramic disk. A 0.5 mm x 0.024 mm region on zirconia was examined on a 500 nm scale for residual stresses using a focused poly-chromatic synchrotron X-ray beam. Large stresses ranging from - to + 1GPa were observed at some grains. On average, the method suggests a relatively small compressive stress at the surface between 47 and 75 MPa depending on direction.

36 MATERIALS SCIENCE↗

Texture, residual strain, and plastic deformation around scratches in alloy 600 using synchrotron x-ray Laue micro-diffraction.

Deformation around two scratches in Alloy 600 (A600) was studied nondestructively using synchrotron Laue differential aperture X-ray microscopy. The orientation of grains and elastic strain distribution around the scratches were measured. A complex residual deviatoric elastic strain state was found to exist around the scratches. Heavy plastic deformation was observed up to a distance of 20 {micro}m from the scratches. In the region 20-30 {micro}m from the scratches the diffraction spots were heavily streaked and split indicating misoriented dislocation cell structures.

43 PARTICLE ACCELERATORS↗

Extracting information from X-ray diffraction patterns containing Laue oscillations

The presence of Laue oscillations in a film grown on a solid surface is broadly taken as indicating a high quality, crystallographically aligned film of the targeted compound. In this paper we briefly review the origins of both Laue oscillations and Kiessig fringes and show how they can be used together to determine if extra thickness exists above or below the coherently diffracting domains. The differences between experimental and “ideal” films are discussed and the effect of structural features (roughness, different thickness coherently diffracting domains and thickness in addition to the coherently diffracting domains) are illustrated with experimental and simulated data for metal and mixed-metal chalcogenide films of titanium, bismuth, vanadium/iron, and bismuth/molybdenum. Examples are given showing how quantitative information can be extracted from experimental diffraction patterns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical pendulum effect in one-dimensional diffraction-thick porous silicon based photonic crystals

We present the realization of the multiperiodic optical pendulum effect in 1D porous silicon photonic crystals (PhCs) under dynamical Bragg diffraction in the Laue scheme. The diffraction-thick PhC contained 360 spatial periods with a large variation of the refractive index of adjacent layers of 0.4. The experiments reveal switching of the light leaving the PhC between the two spatial directions, which correspond to Laue diffraction maxima, as the fundamental wavelength or polarization of the incident light is varied. A similar effect can be achieved when the temperature of the sample or the intensity of the additional laser beam illuminating the crystal are changed. We show that in our PhC structures, the spectral period of the pendulum effect is down to 5 nm, while the thermal period is about 10 °C.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Economical Laue x-ray diffraction using photographic film and orientation of single crystals

Many Laue x-ray diffraction systems using the Polaroid XR-7 Land Diffraction Cassette camera became inactive after production of the required high sensitivity Polaroid T-57 instant film ceased. This Tutorial reports on a low-cost solution using the readily available replacement film with push processing to increase the effective film speed. The use of this film in the polaroid camera is described along with film development and digitization. The orientation of single crystals with the obtained data and free software is explained. A simple method to prepare single crystals with surfaces perpendicular to a desired crystallographic orientation is described. The content of this Tutorial may prove beneficial for educational and research laboratories.

47 OTHER INSTRUMENTATION↗

Complementary use of monochromatic and white-beam X-ray micro-diffraction for the investigation of ancient materials

Archaeological artefacts are often heterogeneous materials where several phases coexist in a wide grain size distribution. Most of the time, retrieving structure information at the micrometre scale is of great importance for these materials. Particularly, the organization of different phases at the micrometre scale is closely related to optical or mechanical properties, manufacturing processes, functionalities in ancient times and long-term conservation. Between classic X-ray powder diffraction with a millimetre beam and transmission electron microscopy, a gap exists and structure and phase information at the micrometre scale are missing. Using a micrometre-size synchrotron X-ray beam, a hybrid approach combining both monochromatic powder micro-diffraction and Laue single-crystal micro-diffraction was deployed to obtain information from nanometre- and micrometre-size phases, respectively. Therefore providing a way to bridge the aforementioned gap, this unique methodology was applied to three different types of ancient materials that all show a strong heterogeneity. In Roman terra sigillata, the specific distribution of nanocrystalline hematite is mainly responsible for the deep-red tone of the slip, while the distribution of micrometre-size quartz in ceramic bodies reflects the change of manufacturing process between pre-sigillata and high-quality sigillata periods. In the second example, we investigated the modifications occurring in Neolithic and geological flints after a heating process. By separating the diffracted signal coming from the nano- and the micrometre scale, we observed a domain size increase for nanocrystalline quartz in geological flints and a relaxation of the residual strain in larger detritic quartz. In conclusion, through the study of a Roman iron nail, we showed that the carburation process to strengthen the steel was mainly a surface process that formed 10–20 µm size domains of single–crystal ferrite and nanocrystalline cementite.

36 MATERIALS SCIENCE↗

Surface Curvatures and Diffraction Profiles of Sagittaly Bent Laue Crystals

The performance of a bent Laue crystal monochromator crucially depends on the sagittal and meridional bending curvatures of the crystal. To optimize the design of monochromator crystals, the surface curvatures and diffraction profiles of a set of sagittally bent Laue crystals with different aspect ratios have been studied experimentally by optical metrology and X-ray measurements. The results were confirmed with finite-element analysis using large-deformation theory. The nonlinear relationship between the curvatures necessitates an experimentally determined parameter in the theoretical modeling of the diffraction profiles. By taking into account the local stress and the aspect ratio of the sagittally bent Laue crystal, the modified analytical approach successfully predicts the rocking-curve width and the integrated reflecting power. The effect of extreme sagittal bending on the rocking curve is also discussed. To retain high reflectivity, the bending curvature should not exceed its critical value for the specified crystal geometry. Furthermore, the uniformity of the bending curvatures across the crystal surface has been examined, which suggests that the minimum crystal dimension should be approximately twice the size of the beam footprint.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computer simulation on spatial resolution of X-ray bright-field imaging by dynamical diffraction theory for a Laue-case crystal analyzer

Recently, dark-field imaging (DFI) and bright-field imaging (BFI) have been proposed and applied to visualize X-ray refraction effects yielded in biomedical objects. In order to clarify the spatial resolution due to a crystal analyzer in Laue geometry, a program based on the Takagi-Taupin equation was modified to be used for carrying out simulations to evaluate the spatial resolution of images coming into a Laue angular analyzer (LAA). The calculation was done with a perfect plane wave for diffraction wave-fields, which corresponded to BFI, under the conditions of 35 keV and a diffraction index 440 for a 2100 {mu}m thick LAA. As a result, the spatial resolution along the g-vector direction showed approximately 37.5 {mu}m. 126 {mu}m-thick LAA showed a spatial resolution better than 3.1 {mu}m under the conditions of 13.7 keV and a diffraction index 220.

36 MATERIALS SCIENCE↗

Correlating Sampling and Intensity Statistics in Nanoparticle Diffraction Experiments

In this article, [Öztürk, Yan, Hill & Noyan (2014). J. Appl. Cryst. 47, 1016-1025] it was shown that the sampling statistics of diffracting particle populations within a polycrystalline ensemble depended on the size of the constituent crystallites: broad X-ray peak breadths enabled some nano-sized particles to contribute more than one diffraction spot to Debye-Scherrer rings. Here it is shown that the equations proposed by Alexander, Klug & Kummer [J. Appl. Phys. (1948), 19, 742-753] (AKK) to link diffracting particle and diffracted intensity statistics are not applicable if the constituent crystallites of the powder are below 10 nm. In this size range, (i) the one-to-one correspondence between diffracting particles and Laue spots assumed in the AKK analysis is not satisfied, and (ii) the crystallographic correlation between Laue spots originating from the same grain invalidates the assumption that all diffracting plane normals are randomly oriented and uncorrelated. Such correlation produces unexpected results in the selection of diffracting grains. Three or more Laue spots from a given grain for a particular reflection can only be observed at certain wavelengths. In addition, correcting the diffracted intensity values by the traditional Lorentz term, 1/cos [theta], to compensate for the variation of particles sampled within a reflection band does not maintain fidelity to the number of poles contributing to the diffracted signal. A new term, cos [theta]B/cos [theta], corrects this problem.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Neutron Macromolecular Crystallography Instruments at Oak Ridge National Laboratory: Advances, Challenges, and Opportunities

The IMAGINE and MaNDi instruments, located at Oak Ridge National Laboratory High Flux Isotope Reactor and Spallation Neutron Source, respectively, are powerful tools for determining the positions of hydrogen atoms in biological macromolecules and their ligands, orienting water molecules, and for differentiating chemical states in macromolecular structures. The possibility to model hydrogen and deuterium atoms in neutron structures arises from the strong interaction of neutrons with the nuclei of these isotopes. Positions can be unambiguously assigned from diffraction studies at the 1.5–2.5 Å resolutions, which are typical for protein crystals. Neutrons have the additional benefit for structural biology of not inducing radiation damage to protein crystals, which can be critical in the study of metalloproteins. Here we review the specifications of the IMAGINE and MaNDi beamlines and illustrate their complementarity. IMAGINE is suitable for crystals with unit cell edges up to 150 Å using a quasi-Laue technique, whereas MaNDi provides neutron crystallography resources for large unit cell samples with unit cell edges up to 300 Å using the time of flight (TOF) Laue technique. The microbial culture and crystal growth facilities which support the IMAGINE and MaNDi user programs are also described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method of making and structure of multilayer laue lens for focusing hard x-rays

A zone plate multilayer structure includes a substrate carrying a plurality of alternating layers respectively formed of tungsten silicide (WSi2) and silicon (Si). The alternating layers are sequentially deposited precisely controlling a thickness of each layer from a minimum thickness of a first deposited layer adjacent the substrate to a maximum thickness of a last deposited layer. The first minimum thickness layer has a selected thickness of less than or equal to 5 nm with the thickness of the alternating layers monotonically increasing to provide a zone plate multilayer structure having a thickness of greater than 12 μm (microns). The x-rays are diffracted in Laue transmission geometry by the specific arrangement of silicon and tungsten silicide.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy resolution of the CdTe-XPAD detector:calibration and potential for Laue diffractionmeasurements on protein crystals

The XPAD3S-CdTe, a CdTe photon-counting pixel array detector, has been used to measure the energy and the intensity of the white-beam diffraction from a lysozyme crystal. A method was developed to calibrate the detector in terms of energy, allowing incident photon energy measurement to high resolution (approximately 140 eV), opening up new possibilities in energy-resolved X-ray diffraction. In order to demonstrate this, Laue diffraction experiments were performed on the bending-magnet beamline METROLOGIE at Synchrotron SOLEIL. The X-ray energy spectra of diffracted spots were deduced from the indexed Laue patterns collected with an imaging-plate detector and then measured with both the XPAD3S-CdTe and the XPAD3S-Si, a silicon photon-counting pixel array detector. The predicted and measured energy of selected diffraction spots are in good agreement, demonstrating the reliability of the calibration method. These results open up the way to direct unit-cell parameter determination and the measurement of high-quality Laue data even at low resolution. Based on the success of these measurements, potential applications in X-ray diffraction opened up by this type of technology are discussed.

36 MATERIALS SCIENCE↗