Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Failure of metoclopramide to control emesis or nausea due to stressful angular or linear acceleration

Orally administered metoclopramide (REGLAN) at doses of 10 or 20 mg, 75 min prior to either stressful linear acceleration (parabolic flight) or cross-coupled accelerative semicircular canal stimulation in a rotating chair was evaluated for its ability to prevent emesis or nausea II, respectively. Although metoclopramide is an effective antiemetic agent that enhances gastric emptying and prevents cancer chemotherapy-induced emesis, it was not possible to demonstrate any significant (p less than 0.05) effects of this drug on motion sickness.

Kohl, Randall Lee↗

SU-F-J-150: Development of An End-To-End Chain Test for the First-In-Man MR-Guided Treatments with the MRI Linear Accelerator by Using the Alderson Phantom

The Alderson phantom is a human shaped quality assurance tool that has been used for over 30 years in radiotherapy. The phantom can provide integrated tests of the entire chain of treatment planning and delivery. The purpose of this research was to investigate if this phantom can be used to chain test a treatment on the MRI linear accelerator (MRL) which is currently being developed at the UMC Utrecht, in collaboration with Elekta and Philips. The latter was demonstrated by chain testing the future First-in-Man treatments with this system.An Alderson phantom was used to chain test an entire treatment with the MRL. First, a CT was acquired of the phantom with additional markers that are both visible on MR and CT. A treatment plan for treating bone metastases in the sacrum was made. The phantom was consecutively placed in the MRL. For MRI imaging, an 3D volume was acquired. The initially developed treatment plan was then simulated on the new MRI dataset. For simulation, both the MR and CT data was used by registering them together. Before treatment delivery a MV image was acquired and compared with a DRR that was calculated form the MR/CT registration data. Finally, the treatment was delivered. Figure 1 shows both the T1 weighted MR-image of the phantom and the CT that was registered to the MR image. Figure 2 shows both the calculated and measured MV image that was acquired by the MV panel. Figure 3 shows the dose distribution that was simulated. The total elapsed time for the entire procedure excluding irradiation was 13:35 minutes.The Alderson Phantom yields sufficient MR contrast and can be used for full MR guided radiotherapy treatment chain testing. As a result, we are able to perform an end-to-end chain test of the future First-in-Man treatments.

60 APPLIED LIFE SCIENCES↗

Experimental Platform for Ultra-high Dose Rate FLASH Irradiation of Small Animals Using a Clinical Linear Accelerator

Purpose: A key factor limiting the effectiveness of radiation therapy is normal tissue toxicity, and recent preclinical data have shown that ultra-high dose rate irradiation (>50 Gy/s, “FLASH”) potentially mitigates this effect. However, research in this field has been strongly limited by the availability of FLASH irradiators suitable for small animal experiments. We present a simple methodologic approach for FLASH electron small animal irradiation with a clinically available linear accelerator (LINAC). Methods and Materials: We investigated the FLASH irradiation potential of a Varian Clinac 21EX in both clinical mode and after tuning of the LINAC. We performed detailed FLUKA Monte Carlo and experimental dosimetric characterization at multiple experimental locations within the LINAC head. Results: Average dose rates of ≤74 Gy/s were achieved in clinical mode, and the dose rate after tuning exceeded 900 Gy/s. We obtained 220 Gy/s at 1-cm depth for a >4-cm field size with 90% homogeneity throughout a 2-cm-thick volume. Conclusions: We present an approach for using a clinical LINAC for FLASH irradiation. We obtained dose rates exceeding 200 Gy/s after simple tuning of the LINAC, with excellent dosimetric properties for small animal experiments. This will allow for increased availability of FLASH irradiation to the general research community.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reevaluating linear accelerator shielding for 320 µA of proton beam

The collider-accelerator facilities at Brookhaven National Laboratory (BNL) have been developing since the completion of the experiments they were originally built for, and their uses for research have evolved over the years with a variety of users. With these changes, we must be careful to avoid potential radiation hazards of worst-case scenarios, although these faults are unlikely. One of these changes in the Collider-Accelerator Department (C-AD) is the replacement of power supplies and upgrading the linear accelerator (Linac) radiofrequency system to allow the Brookhaven Linac Isotope Producer (BLIP) to use a 320 μA average current. This current of 320 μA is greater than any current that the Linac shielding has withstood before, and thus this project in reevaluating the Linac shielding is necessary to ensure all future Linac research is conducted safely. Particularly, this project aims to estimate the radiation doses in the Alternating Gradient Synchrotron (AGS) tunnel near the Linac tunnel and in the equipment bay room near the gate valve of the last tank (tank 9) of Linac. To do this, we used the particle transport code, Monte Carlo N-Particle 6.2 (MCNP6.2), to perform the simulation and model the facilities of Linac and AGS at BNL. This simulation allowed us to investigate the extent of radiation dose rates in various areas of the facilities by placing detectors in specific locations. We could therefore determine whether the dose rates due to these faults is acceptable for limits set by the Department of Energy (DOE) and BNL, and if the shielding is sufficient.

43 PARTICLE ACCELERATORS↗

Machine-Protection System for the PIP-II Linear Accelerator: Architecture and Data Processing Schemes

PIP-II at Fermilab features a brand-new, 800 MeV leading-edge Linear Accelerator (Linac) that will enable the Fermilab complex to deliver more than a megawatt of beam power to the Long Base-line Neutrino Facility (LBNF), requiring a robust Machine Protection System (MPS) to prevent beam-induced damage to delicate cryomodules and vacuum components. Signals in various accelerator components, in both analog and digital format, are collected and processed to assest the operating conditions of the accelerator. In the situation a potential damage is foreseen, the beam permit signal will be drop. A critical element of this system is the fast Analog Machine Protection System, a high-bandwidth platform designed for real-time beam loss monitoring. The system utilizes a modular, FPGA-based architecture to digitize signals from beam-sensing devices, such as AC Current Transformers (ACCTs), non-invasive Ring Pickups (RPUs) and beam scrapers. To eliminate both high frequency as well as 60 Hz noise that might be picked up in the industrial environment, data processing schemes beyond regular digital filtering are planned and implemented.

Wu, Jinyuan [Fermilab] (ORCID:0000000344329521)↗

High-power test of a C-band linear accelerating structure with an RFSoC-based LLRF system

Normal conducting linear particle accelerators consist of multiple rf stations with accelerating structure cavities. Low-level rf (LLRF) systems are employed to set the phase and amplitude of the field in the accelerating structure and to compensate for the pulse-to-pulse fluctuation of the rf field in the accelerating structures with a feedback loop. The LLRF systems are typically implemented with analog rf mixers, heterodyne-based architectures, and discrete data converters. There are multiple rf signals from each of the rf stations, so the number of rf channels required increases rapidly with multiple rf stations. With a large number of rf channels, the footprint, component cost, and system complexity of the LLRF hardware will increase significantly. To meet the design goals of being compact and affordable for future accelerators, we have designed the next-generation LLRF (NG-LLRF) with a higher integration level based on RFSoC technology. The NG-LLRF system samples rf signals directly and performs rf mixing digitally. Further, the NG-LLRF has been characterized in loopback mode to evaluate the performance of the system and has also been tested with a standing-wave accelerating structure, a prototype for the Cool Copper Collider (C 3 ) with a peak rf power level up to 16.45 MW. The loopback test demonstrated amplitude fluctuation below 0.15% and phase fluctuation below 0.15°, which are considerably better than the requirements of C 3 . The rf signals from the different stages of the accelerating structure at different power levels are measured by the NG-LLRF, which will be critical references for the control algorithm designs. The NG-LLRF also offers flexibility in waveform modulation, so we have used rf pulses with various modulation schemes, which could be useful for controlling some of the rf stations in accelerators. In this paper, the high-power test results at different stages of the test setup will be summarized, analyzed, and discussed.

47 OTHER INSTRUMENTATION↗

A MHz-repetition-rate hard X-ray free-electron laser driven by a superconducting linear accelerator

The European XFEL is a hard X-ray free-electron laser (FEL) based on a high-electron-energy superconducting linear accelerator. The superconducting technology allows for the acceleration of many electron bunches within one radio-frequency pulse of the accelerating voltage and, in turn, for the generation of a large number of hard X-ray pulses. In this paper, we report on the performance of the European XFEL accelerator with up to 5,000 electron bunches per second and demonstrating a full energy of 17.5 GeV. Feedback mechanisms enable stabilization of the electron beam delivery at the FEL undulator in space and time. The measured FEL gain curve at 9.3 keV is in good agreement with predictions for saturated FEL radiation. Hard X-ray lasing was achieved between 7 keV and 14 keV with pulse energies of up to 2.0 mJ. Using the high repetition rate, an FEL beam with 6 W average power was created.

43 PARTICLE ACCELERATORS↗

Cathode Side-emission Mitigation for Linear Induction Accelerators

Linear induction accelerators (LIAs) are one of the main technologies used in creating flash x-rays used for diagnosing hydrodynamic experiments. The quality of the data produced in these experiments is dependent on the dose of x-rays generated via bremsstrahlung radiation. There are several electron beam quantities that effect the amount of dose extracted from the bremsstrahlung radiation, such as beam instabilities, corkscrew motion, and beam emittance. Injector design is key in delivering well-behaved electron beams to the accelerator, and design choices include components such as anode-cathode (AK) gap dimensions based on required voltage and current, shroud shaping, and cathode type and composition. Thermionic cathodes have shown reliable performance in electron emission, however, if enough of the cathode side is subject to high-enough electric field values, electrons can be emitted. This issue is more likely to happen when the cathode is treated with materials that have lower work functions, which is common for cathodes used in LIAs. These extra electrons can work their way through the rest of the beam, inducing high non-linearities in phase space which can increase the emittance of this beam. In this paper we outline conducted trade-space studies where we examined different shaping parameters of the cathode shroud design to decrease the effect side electrons may have on the beam emittance. Particle trajectories are determined by electric potential contours across the face of the cathode shroud component, and so we hypothesize that the proper shaping of the cathode-shroud interface can tune the electric field to mitigate the effect of side electrons. Electron beam transport is simulated down the length of the injector and the beam quality is diagnosed by studying the emittance as a function of position. Acceptable emittance increase is recorded and noted to meet radiographic requirements.

42 ENGINEERING↗

Tuning of LANSCE 805-MHz high-energy linear accelerator with reduced beam losses

Suppression of beam losses is essential for successful operation of high-intensity linac. Historically, the values of the field amplitudes and phases of the side-coupled, 805-MHz LANSCE linac modules are maintained using a well-known delta-t tuning procedure. Transverse matching of the beam with accelerator is performed through adjustments of beam ellipses in 4D phase space with accelerator lattice using matching quadrupoles. Control of the beam-energy ramp along the length of a proton linear accelerator is required to improve tune of accelerator and decrease beam losses. Time-of-flight measurements of the H - beam energy are now being used to confirm and improve the overall control of the energy ramp along the linac. The time-of-flight method utilizes absolute measurements of beam energy using direct signals from beam at an oscilloscope, as well as the difference in RF phases measured as the beam passes installed delta-t pickup loops. A newly developed BPPM data acquisition system is used. Beam energy measurement along accelerator together with phase scans, klystrons output power control, and delta-t method, allow tuning of accelerator much more close to original design and reduce losses generated by linac. Details of the upgraded tuning procedure and results of tuning and operation are presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mitigation of Beam Losses in LANSCE Linear Accelerator

Suppression of beam losses is essential for successful operation of high-intensity accelerator facility. The LANSCE accelerator started routine operation in 1972 as a 0.8 MW average proton beam power facility for meson physics research, and delivered highpower beam for a quarter century. The accelerator currently delivers 100 MeV proton beam to Isotope Production Facility (IPF) and 800 MeV H- beams to various experimental areas. The accelerator is equipped with two independent injectors for H + and H - beams, merging at the entrance of a 201.25 MHz Drift Tube Linac (DTL). The DTL performs acceleration up to the energy of 100 MeV. After the DTL, the Transition Region beamline directs a 100 MeV proton beam to the Isotope Production Facility, while the H - beam is accelerated up to the final energy of 800 MeV in an 805- MHz Coupled Cavity Linac. The H - beams, created with different time structure by a lowenergy chopper, are distributed in the Switch Yard (SY) to four experimental areas: the Lujan Neutron Scattering Center equipped with a Proton Storage Ring (PSR), the Weapons Neutron Research facility (WNR), the Proton Radiography facility (pRad), and the Ultra-Cold Neutron facility (UCN). Multi-beam operation requires careful control of accelerator tune to minimize beam losses. In this paper we review main effects affecting beam losses in LANSCE linear accelerator and discuss methods to reduce them.

43 PARTICLE ACCELERATORS↗

Laser and optical transport line for laser-based ion beam diagnostics and control in the SNS linear accelerator

We report our recent upgrade of the laser and optical transport line for the laser-based ion beam diagnostics (laser wire) system at the linear accelerator (linac) of the Spallation Neutron Source (SNS). A new light source based on diodepumped solid-state laser amplifiers has been developed to provide near diffraction-limited laser beam with a variety of pulse structures. The free-space optical transport line has been modified to include image relay optics with remote control, which greatly improved the laser beam quality and position stability at individual measurement stations. The upgraded system enables novel beam diagnostics/control capabilities including longitudinal profile measurement and high-energy proton beam extraction from the SNS linac.

Liu, Yun↗

Assessment of operational availability for the PIP-II Superconducting Radio Frequency linear accelerator facility

Operational availability is a critical performance measure for an accelerator facility in modern time. A high availability enables the facility to serve a wide range of users simultaneously. Consequently, besides pure accelerator physics considerations, newly proposed accelerator facilities account for the availability and reliability aspects in the design phases. It allows incorporation of appropriate mitigation strategies for the most vulnerable systems in the machine and therefore, minimizes unscheduled interruptions during the operation. This report lays out a methodology for the availability assessment of the complete particle accelerator facility and presents an initial assessment of the availability of the newly proposed Proton Improvement Plan-II (PIP-II) accelerator facility at Fermilab. The paper describes a comprehensive reliability model of the PIP-II facility that comprises not only 800 MeV linear accelerator (linac) system but also essential utility systems in the form of cryogenic, water, power and air systems. The paper details estimations of the availability of the PIP-II facility for two operational modes i.e. the nominal operational mode featuring 800 MeV beam and critical operational mode involving operation with the lowest objective beam energy of 600 MeV.

43 PARTICLE ACCELERATORS↗

The fast linear accelerator modeling engine for FRIB online model service

Commissioning of a large accelerator facility like FRIB needs support from an online beam dynamics model. Considering the new physics challenges of FRIB such as modeling of non-axisymmetric superconducting RF cavities and multi-charge state acceleration, there is no readily available online beam tuning code. The design code of FRIB super-conducting linac, IMPACT-Z, is not suitable for online tuning because of its code design and running speed. Therefore, the Fast Linear Accelerator Modeling Engine (FLAME), specifically designed to fulfill FRIB’s online modeling challenges, is proposed. The physics model of FLAME, especially its novel way of modeling non-axisymmetric superconducting RF cavities using a multipole expansion based thin-lens kick model, is discussed in detail, and the benchmark results against FRIB design code is presented, after which the software design strategy of FLAME and its execution speed is presented.

43 PARTICLE ACCELERATORS↗