Predicting non-linear stress–strain response of mesostructured cellular materials using supervised autoencoder

Recent breakthroughs in advanced manufacturing capabilities have made it possible to design and print sophisticated topologies of cellular structures using diverse engineering materials such as metals, polymers, and ceramics. In these architectured materials, it is often desirable to tailor the mechanical properties by altering the unit cell topology. This necessitates an in-depth understanding of how the topology of the unit cell structure affects the macroscopic behavior of the material in both the linear and the non-linear regimes encountered under large compression. Here, we have developed a machine learning (ML) approach capable of accelerating the prediction of the stress–strain response of a polymer-based cellular structure under uniaxial confined compression. As part of generating the training data for ML, 60,000 mesostructures were generated using a relatively novel approach based on cellular automata, and their corresponding stress–strain responses were obtained from the finite element simulations. Principal component analysis (PCA) was used to reduce the dimensionality of the stress–strain curves. With only 20 principal components, PCA captured 99.89% of the variance in the stress–strain curves while reducing the dimensionality by 5X. ML using supervised autoencoder was able to successfully speed up the prediction of the non-linear stress–strain response of a unit cell by up to 4600X. The proposed method can serve as an efficient data generation tool and a rapid means for predicting the structure–property relationship through accelerated forward modeling of cellular materials under compaction, in cases where the macroscopic stress–strain response is governed by the unit-cell topology.

36 MATERIALS SCIENCE↗

Interpretable, extensible linear and symbolic regression models for charge density prediction using a hierarchy of many-body correlation descriptors

Here, density functional theory (DFT) is routinely used to make electronic structure predictions for high-throughput screening of materials and molecules for technologically relevant areas, like the identification of better catalysts, electronic materials, and drug discovery. However, the DFT formalism is limited by (a) its poor (quadratic-to-quartic) scaling, and (b) the need to perform repeated eigenvalue computations of the electronic Hamiltonian as part of its self-consistent field (SCF) iteration procedure to obtain the converged ground state electron density, ρ (r). Approaches that directly predict ρ (r) of a structure with high accuracy can accelerate conventional SCF calculations and can also be used in linearly scaling methods such as orbital-free DFT. To this end, we present a procedure to predict the ground state electron density of molecular and periodic three-dimensional systems directly from the atomic structure with a particular emphasis on physical interpretability. In our framework, ρ (r) is modeled using many-body correlation descriptors that accurately capture the effects of local atomic arrangements in the neighborhood of a grid point. Our use of a linear regression scheme to fit to charge density data enables transparent analysis of the relative contributions of various types of local atomic correlations. By systematically including increasingly complex correlations, our model is shown to accurately predict ρ (r) for a variety of chemically and electronically diverse systems — amorphous Ge, Al(001) slab, crystalline Ga 2 O 3 , molecular benzene, and polyethylene. We then demonstrate a symbolic regression-based protocol to construct easily computable, interpretable features from lower-order correlations that significantly improves our electron density predictions with effectively no increase in the computational cost.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Source-to-accelerator quadrupole matching section for a compact linear accelerator

Recently, we presented a new approach for a compact radio-frequency (RF) accelerator structure and demonstrated the functionality of the individual components: acceleration units and focusing elements. In this paper, we combine these units to form a working accelerator structure: a matching section between the ion source extraction grids and the RF-acceleration unit and electrostatic focusing quadrupoles between successive acceleration units. The matching section consists of six electrostatic quadrupoles (ESQs) fabricated using 3D-printing techniques. The matching section enables us to capture more beam current and to match the beam envelope to conditions for stable transport in an acceleration lattice. We present data from an integrated accelerator consisting of the source, matching section, and an ESQ doublet sandwiched between two RF-acceleration units.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse Length Monitor for Breakdown Diagnostics in THz and Mm-Wave Accelerators

The development of novel high-gradient accelerating structures operating at THz frequencies is critical for future free-electron lasers and TeV scale linear colliders. To reach high energies with reasonable length requires high accelerating gradients of ~100 MV/m. The main limitation to reaching these high-energy gradients is the vacuum RF breakdown phenomenon, which disrupts normal accelerator operations. For stable operations and to understand the breakdown microscopic dynamics, a new device capable of detecting the breakdown occurrences is required. In this paper, we provide the design of a pulse length monitor based on an analog to digital converter for fast signal digitization without the need to use high-speed digitizers to be used in a commercial mm-wave heterodyne spectrometer.

43 PARTICLE ACCELERATORS↗

Electron pulse train accelerated by a linearly polarized Laguerre–Gaussian laser beam

A linearly polarized Laguerre–Gaussian (LP-LG) laser beam with a twist index $l$ = –1 has field structure that fundamentally differs from the field structure of a conventional linearly polarized Gaussian beam. Close to the axis of the LP-LG beam, the longitudinal electric and magnetic fields dominate over the transverse components. This structure offers an attractive opportunity to accelerate electrons in vacuum. It is shown, using three-dimensional particle-in-cell simulations, that this scenario can be realized by reflecting an LP-LG laser off a plasma with a sharp density gradient. The simulations indicate that a 600 TW LP-LG laser beam effectively injects electrons into the beam during the reflection. The electrons that are injected close to the laser axis experience a prolonged longitudinal acceleration by the longitudinal laser electric field. The electrons form distinct monoenergetic bunches with a small divergence angle. The energy in the most energetic bunch is 0.29 GeV. The bunch charge is 6 pC and its duration is approximately 270 as. The divergence angle is just 0.57° (10 mrad). By using a linearly polarized rather than a circularly polarized Laguerre–Gaussian beam, our scheme makes it easier to demonstrate the electron acceleration experimentally at a high-power laser facility.

43 PARTICLE ACCELERATORS↗

Development work for a superconducting linear collider

For future linear e(+)e(-) colliders in the TeV range several alternatives are under discussion. The TESLA approach is based on the advantages of superconductivity. High Q values of the accelerator structures give high efficiency for converting RF power into beam power. A low resonance frequency for the RF structures can be chosen to obtain a large number of electrons (positrons) per bunch. For a given luminosity the beam dimensions can be chosen conservatively which leads to relaxed beam emittance and tolerances at the final focus. Each individual superconducting accelerator component (resonator cavity) of this linear collider has to deliver an energy gain of 25 MeV/m to the beam. Today s.c. resonators are in use at CEBAF/USA, at DESY/Germany, Darmstadt/Germany KEK/Japan and CERN/Geneva. They show acceleration gradients between 5 MV/m and 10 MV/m. Encouraging experiments at CEA Saclay and Cornell University showed acceleration gradients of 20 MV/m and 25 MV/m in single and multicell structures. In an activity centered at DESY in Hamburg/Germany the TESLA collaboration is constructing a 500 MeV superconducting accelerator test facility (TTF) to demonstrate that a linear collider based on this technique can be built in a cost effective manner and that the necessary acceleration gradients of more than 15 MeV/m can be reached reproducibly. The test facility built at DESY covers an area of 3.000 m2 and is divided into 3 major activity areas: (1) The testlinac, where the performance ofthe modular components with an electron beam passing the 40 m long acceleration section can be demonstrated. (2) The test area, where all individual resonators are tested before installation into a module. (3) The preparation and assembly area, where assembly of cavities and modules take place. We report here on the design work to reach a reduction of costs compared to actual existing superconducting accelerator structures and on the facility set up to reach high acceleration gradients in a reproducible way.

Matheisen, Axel↗

Functions of the nucleon structure and determination of the strong coupling constant

The properties of deep inelastic scattering at high energies, as well as results of fitting of experimental data on structure functions, obtained by BCDMS, SLAC, NMC, and BFP collaborations in fixed target experiments, with the aim of determining the strong coupling constant, the shape of parton distributions, and power corrections to F{sub 2}(x, Q {sup 2}), are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accelerated Block Preconditioned Gradient method for large scale wave functions calculations in Density Functional Theory

An Accelerated Block Preconditioned Gradient (ABPG) method is proposed to solve electronic structure problems in Density Functional Theory. This iterative algorithm is designed to solve directly the non-linear Kohn-Sham equations for accurate discretization schemes involving a large number of degrees of freedom. It makes use of an acceleration scheme similar to what is known as RMM-DIIS in the electronic structure community. The method is illustrated with examples of convergence for large scale applications using a finite difference discretization and multigrid preconditioning.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Staging of RF-accelerating Units in a MEMS-based Ion Accelerator

Multiple Electrostatic Quadrupole Array Linear Accelerators (MEQALACs) provide an opportunity to realize compact radio- frequency (RF) accelerator structures that can deliver very high beam currents. MEQALACs have been previously realized with acceleration gap distances and beam aperture sizes of the order of centimeters. Through advances in Micro-Electro-Mechanical Systems (MEMS) fabrication, MEQALACs can now be scaled down to the sub-millimeter regime and batch processed on wafer substrates. In this paper we show first results from using three RF stages in a compact MEMS-based ion accelerator. The results presented show proof-of-concept with accelerator structures formed from printed circuit boards using a 3 × 3 beamlet arrangement and noble gas ions at 10 keV. We present a simple model to describe the measured results. We also discuss some of the scaling behaviour of a compact MEQALAC. The MEMS-based approach enables a low-cost, highly versatile accelerator covering a wide range of currents (10 μA to 100 mA) and beam energies (100 keV to several MeV). Applications include ion-beam analysis, mass spectrometry, materials processing, and at very high beam powers, plasma heating.

43 PARTICLE ACCELERATORS↗

Analytic and 'frozen' coupling constants in QCD up to NNLO from DIS data

Deep inelastic scattering data on the F{sub 2} structure function provided by the BCDMS, SLAC, and NMC Collaborations are analyzed in the nonsinglet approximation with the analytic and 'frozen' modifications of the strong-coupling constant featuring no unphysical singularity (the Landau pole). Improvement of agreement between theory and experiment, with respect to the case of the standard perturbative definition of {alpha}{sub s} considered recently, is observed and the higher-twist terms are shown to reduce at the next-to-next-to-leading order accuracy thus confirming earlier studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Challenges in Linear Accelerator Radiotherapy for Chordomas and Chondrosarcomas of the Skull Base: Focus on Complications

Purpose: Intracranial chordomas and chondrosarcomas are histologically low-grade, locally invasive tumors that infiltrate the skull base. Currently, consensus therapy includes surgical resection and adjuvant radiotherapy. Radiation delivery is typically limited by the proximity of these tumors to critical skull base structures. Methods: This is a retrospective review of 13 cases of chordomas and 2 cases of chondroid chondrosarcomas of the skull based treated with linear accelerator stereotactic radiotherapy (SRT, n = 10) or stereotactic radiosurgery (SRS, n = 5). The average time to the most recent follow-up visit was 4.5 years. The tumor characteristics, treatment details, and outcomes were recorded. Each radiation plan was reviewed, and the dosage received by the brainstem, optic apparatus, and pituitary was calculated. Results: Of the 10 patients treated with SRT, 6 were found to have unchanged or decreased tumor size as determined from radiographic follow-up. Of the 5 patients treated with SRS, 3 were found to have stable or unchanged tumors at follow-up. The complications included 1 SRT patient who developed endocrinopathy, 2 patients (1 treated with SRS and the other with SRT), who developed cranial neuropathy, and 1 SRS patient who developed visual deficits. Additionally, 1 patient who received both SRS and SRT within 2 years for recurrence experienced transient medial temporal lobe radiation changes that resolved. Conclusions: Where proton beam therapy is unavailable, linear accelerator-based SRT or radiosurgery remains a safe option for adjuvant therapy of chordomas and chondrosarcomas of the skull base. The exposure of the optic apparatus, pituitary stalk, and brainstem must be considered during planning to minimize complications. If the optic apparatus is included in the 80% isodose line, it might be best to fractionate therapy. Exposure of the pituitary stalk should be kept to <30 Gy to minimize endocrine dysfunction. Brainstem exposure should be limited to <60 Gy in fractions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary Study on Two Possible Bunch Compression Schemes at NLCTA

In this paper, two possible bunch compression configurations are proposed and evaluated by numerical simulation in the Next Linear Collider Test Accelerator (NLCTA) at SLAC. A bunch compression ratio up to 20 could be achieved under a perfect condition, without consideration for the timing jitter and other error sources. The NLCTA is a test accelerator built at SLAC, which is approximately 42 meters long and composed of X-band acceleration structures. The main aim of building NLCTA is to develop and demonstrate the X-band rf acceleration technologies for the next generation linear collider, with a relatively high acceleration gradient between 50 MV/m and 100 MV/m. The current operation configuration of NLCTA features a thermionic-cathode electron gun at its starting point which generates an electron beam with an energy of 5 MeV. This is followed by a roughly 1.5 meter long X-band acceleration structure which boosts the electron beam energy to 60 MeV. Then there is a four-dipole magnetic chicane which is 6 meters long and provides a first order longitudinal dispersion of R{sub 56} = -73mm. Next the electron beam passes by several matching quadrupoles and can be accelerated further to 120 MeV through another one-meter-long X-band acceleration structure. After that, there are three small chicanes downstream, with a total first order longitudinal dispersion of R{sub 56} = -10mm. A sketch of the main components of NLCTA is shown in Figure 1, where the total length of this accelerator is 45 meters. Free Electron Lasers (FELs), proposed by J. Madey and demonstrated for the first time at Stanford University in 1970s [2] [3], use the lasing of relativistic electron beam traveling through a magnetic undulator, which can reach high power and can be widely tunable in wavelength. Linac based FEL source can provide sufficient brightness, and a short X-ray wavelength down to angstrom scale, which promises in supporting wide range of research experiments. In order to have an electron beam lasing coherently in an undulator, one needs a very bright beam in all three dimensions. In other words, one needs an electron beam with very short bunch length (high intensity), very small transverse emittance and very small energy spread. Most FELs currently being operated, commissioned, constructed or proposed are based on RF acceleration in a frequency range from L-band ( 1 GHz) to C-band ( 6 GHz). As RF frequency goes higher, wake fields effects tend to be much stronger and jitter tolerances are tighter. To demonstrate that X-band acceleration structures can be applied in constructing an FEL, one could perform bunch compression experiments at NLCTA as a first step, and investigate tolerances on timing jitter, misalignments etc.. Another important point is to evaluate the transverse emittance growth in this bunch compression process. In the following sections, two possible bunch compression schemes are proposed to be tested at NLCTA. Elegant [4] 3-D simulation is performed to evaluate these two schemes, with wake fields, space charge and coherent synchrotron radiation (CSR) effects included. One million macro particles are adopted in the numerical simulations. The simulation starts with an electron beam of 20 pC at a beam energy of 5 MeV. The initial RMS bunch length is taken as 0.5 ps at such a low bunch charge, and the RMS energy spread is 5 x 10{sup -3}. The normalized transverse emittance is 1 mm.mrad.

43 PARTICLE ACCELERATORS↗

The Klynac: An Integrated Klystron and Linear Accelerator

The Klynac concept integrates an electron gun, a radio frequency (RF) power source, and a coupled-cavity linear accelerator into a single resonant system. The klystron is essentially a conventional klystron structure with an input cavity, some number of intermediate cavities and an output cavity. The accelerator structure is, likewise, a conventional on-axis coupled structure. The uniqueness is the means of coupling the klystron output cavity to the accelerator. The coupler is a resonant coupler rather than an ordinary transmission line. The geometry of such a system need not be coaxial. However, if the klystron and accelerator are coaxial we can eliminate the need for a separate cathode for the accelerator by injecting some of the klystron beam into the accelerator. Such a device can be made cylindrical which is ideal for some applications.

klystron, linear accelerator, klynac, beam energy,↗

Research and Development for Ultra-High Gradient Accelerator Structures

Research on the basic physics of high-gradient, high frequency accelerator structures and the associated RF/microwave technology are essential for the future of discovery science, medicine and biology, energy and environment, and national security. We will review the state-of-the-art for the development of high gradient linear accelerators. We will present the research activities aimed at exploring the basic physics phenomenon of RF breakdown. We present the experimental results of a true systematic study in which the surface processing, geometry, and materials of the structures have been varied, one parameter at a time. The breakdown rate or alternatively, the probability of breakdown/pulse/meter has been recorded for different operating parameters. These statistical data reveal a strong dependence of breakdown probability on surface magnetic field, or alternatively on surface pulsed heating. This is in contrast to the classical view of electric field dependence.

43 PARTICLE ACCELERATORS↗

Nuclear structure and depletion of nuclear isomers using electron linacs

Long-lived nuclear excited states (isomers) have proven important to understanding nuclear structure. With some isomers having half-lives of decades or longer, and intrinsic energy densities reaching 10{sup 12} J/kg, they have also been suggested for a wide range of applications. The ability to effectively transfer a population of nuclei from an isomer to shorter-lived levels will determine the feasibility of any applications. Here is described a first demonstration of the induced depletion of a population of the 438 year isomer of {sup 108}Ag to its 2.38 min ground state, using 6 MeV bremsstrahlung from a modified medical electron linac. The experiment suggests refinements to be implemented in the future and how a similar approach might be applied to study induced depletion of the 1200 year isomer of {sup 166}Ho.

43 PARTICLE ACCELERATORS↗

Assessment of Out-of-Field Doses in Radiotherapy of Brain Lesions in Children

Purpose: To characterize the out-of-field doses in pediatric radiotherapy and to identify simple methods by which out-of-field dose might be minimized, with a view to reducing the risk of secondary cancers. Methods and Materials: With the aim of characterizing the peripheral doses under different treatment conditions, the dose measurements in an anthropomorphic child phantom were taken in various organs and critical structures outside the primary field using thermoluminescent dosimetry. The doses from a Varian 600C and Varian Trilogy linear accelerator, both at 6 MV, were investigated. Results: Larger field sizes have been shown to result in greater peripheral doses close to the primary beam, with the difference becoming less significant at large distances, indicating that most of out-of-field doses result from head leakage and collimator scatter >40 cm from the primary field. The use of lead shields has been shown to reduce the absorbed dose resulting from leakage. Aligning the craniocaudal axis of the patient with the x-plane of the collimator resulted in a dose reduction of 40%, for both machines. Out-of-field doses from the Varian Trilogy were shown to be approximately 40% greater than those from the 600C linear accelerator, despite being operated at the same energy. Conclusion: Out-of-field doses to pediatric patients can be minimized by using simple treatment options, such as using the single-energy mode linear accelerator rather than the multimode, orienting the couch and collimator such that the patient lies along the x-plane and avoiding fields directed along the trunk of the body.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Linear Proof-Mass Actuator

Linear proof-mass actuator (LPMA) is friction-driven linear mass actuator capable of applying controlled force to structure in outer space to damp out oscillations. Capable of high accelerations and provides smooth, bidirectional travel of mass. Design eliminates gears and belts. LPMA strong enough to be used terrestrially where linear actuators needed to excite or damp out oscillations. High flexibility designed into LPMA by varying size of motors, mass, and length of stroke, and by modifying control software.

Holloway, Sidney E., III↗

The Klynac: An integrated klystron and linear accelerator

The Klynac concept integrates an electron gun, a radio frequency (RF) power source, and a coupled-cavity linear accelerator into a single resonant system. The klystron is essentially a conventional klystron structure with an input cavity, some number of intermediate cavities and an output cavity. The accelerator structure is, likewise, a conventional on-axis coupled structure. The uniqueness is the means of coupling the klystron output cavity to the accelerator. The coupler is a resonant coupler rather than an ordinary transmission line. The geometry of such a system need not be coaxial. However, if the klystron and accelerator are coaxial we can eliminate the need for a separate cathode for the accelerator by injecting some of the klystron beam into the accelerator. Such a device can be made cylindrical which is ideal for some applications.

43 PARTICLE ACCELERATORS↗