Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid helium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Thermal conductance of pressed aluminum and stainless steel contacts at liquid helium temperatures

The thermal conductance of aluminum and stainless steel 304 sample pairs with surface finishes ranging from 0.1 to 1.6 microns rms roughness was investigated over a temperature range from 1.6 to 6.0 k. The thermal conductance follows a simple power law function of temperature, with the exponent ranging from 0.5 to 2.25, increases asymptotically with increasing applied force, and exhibits an anomaly for surface finishes in the 0.4 micron region.

Salerno, L. J.↗

Liquid helium cooled Fabry-Perot spectrometers

An account is given of two successful efforts to construct cryogenic Fabry-Perot interferometers that are sufficiently compact and stable for such harsh conditions as those of balloon or space observations, as well as ground-based ones. Attention is given to the design features and performance of a Fabry-Perot interferometer incorporating an electromagnet actuator, the ISAS interferometer, a Fabry-Perot spectrometer with superconducting actuators, and the University of Arizona interferometer.

Okuda, H.↗

Facility for interferometric testing of 1.25-m mirrors at liquid helium temperatures

A concept is presented for a national cryogenic optics test facility capable of optical characterization of 1.25 m diameter optics having focal lengths up to 6.2 m at temperatures from 300 K to near 4 K. The facility will be comprised of a large Dewar with a phase shift interferometer, a two stage vacuum system employing a turbomolecular pump, and an integral vibration isolation system. The entire facility will be housed in a concrete site with a massive floor to assist in reducing vibration during optical tests. By providing interchangeable sections, the overall height of the Dewar can be adjusted to provide for testing of shorter focal length optics. The background for the facility is discussed along with the facility location, and the requirements and the performance considerations which drive the Dewar design with respect to the vibration isolation system, vacuum system, and optical interferometry.

Salerno, Louis J.↗

Thermal conductance of pressed aluminum and stainless steel contacts at liquid helium temperatures

The thermal conductance of aluminum and stainless steel 304 sample pairs with surface finishes ranging from 0.1 to 1.6 microns rms roughness was investigated over a temperature range from 1.6 to 6.0 K. The thermal conductance follows a simple power law function of temperature, with the exponent ranging from 0.5 to 2.25, increases asymptotically with increasing applied force, and exhibits an anomaly for surface finishes in the 0.4 micron region.

Salerno, L. J.↗

Facility for interferometric testing of 1.25-m mirrors at liquid helium temperatures

A concept is presented for a national cryogenic optics test facility capable of optical characterization of 1.25 m diameter optics having focal lengths up to 6.2 m at temperatures from 300 K to near 4 K. The facility will be comprised of a large Dewar with a phase shift interferometer, a two-stage vacuum system employing a turbomolecular pump, and an integral vibration isolation system. The entire facility will be housed in a concrete site with a massive floor to assist in reducing vibration during optical tests. By providing interchangeable sections, the overall height of the Dewar can be adjusted to provide for testing of shorter focal length optics. The background for the facility is discussed along with the facility location, and the requirements and the performance considerations which drive the Dewar design with respect to the vibration isolation system, vacuum system, and optical interferometry.

Salerno, Louis J.↗

Thermal conductance of augmented pressed metallic contacts at liquid helium temperatures

The thermal conductance of uncoated oxygen-free high conductivity (OFHC) copper, 6061-T6 aluminum, free-machining brass, and 304 stainless steel sample pairs which were augmented with a gold coated 6061-T6 aluminum washer inserted between the contact surfaces was measured over the temperature range of 1.6 to 6.0 K, with applied forces from 22 to 670 N. The contact surfaces of the sample pairs were prepared with a 0.8 micron lapped finish, while the finish of the aluminum washer was 0.2 micron lapped. The contribution to the overall thermal impedance by the bulk conductance of the aluminum washer was negligible. It was found that addition of the washer offered no significant conductance improvement over an uncoated single contact pair; any benefits from using the gold plated washer were counteracted by the addition of two more contact surfaces. Additionally, the thermal conductance of a 'combination' aluminum sample pair having one gold coated and one uncoated surface was measured and compared to the washer pair. The ratio of the conductance of the washer pair to half the conductance of the 'combination' pair was found to be constant and near unity over the temperature range of the data obtained, within experimental error.

Salerno, L. J.↗

Thermal conductance of gold plated metallic contacts at liquid helium temperatures

The thermal conductance of gold plated OFHC copper, 6061-T6 aluminum, free-machining brass, and 304 stainless steel contacts has been measured over the temperature range of 1.6 to 4.2 K, with applied forces from 22 N to 670 N. The contact surfaces were prepared with a 0.8 micron lapped finish prior to gold coating. It was found that for all materials, except stainless steel, the thermal conductance was significantly improved as the result of gold coating the contact surfaces.

Kittel, Peter↗

Thermal conductance of pressed metallic contacts augmented with Indium foil or Apiezon-N (tm) grease at liquid helium temperatures

The thermal conductance of pressed contacts which have been augmented with Indium foil or Apiezon-N (tm) grease was measured over the temperature range of 1.6 to 6.0 K, with applied forces from 22 N to 670 N. The sample pairs were fabricated from OFHC copper, 6061-T6 aluminum, free-machining brass, and 304 stainless steel. Although the thermal conductance was found to increase with increasing applied contact force, the force dependence was less than in earlier work. The addition of Indium foil or Apiezon-NT grease between the contact surfaces resulted in an improvement over uncoated surfaces ranging from a factor of approximately 3 for stainless steel to an order of magnitude for copper contacts.

Salerno, Louis J.↗

Effect of baffle on slosh reaction forces in rotating liquid helium subjected to a lateral impulse in microgravity

Sloshing dynamics within a partially filled rotating Dewar of superfluid He II are investigated in response to a lateral impulse. The study investigates several factors, including how the rotating bubble of superfluid He II reacts to the impulse in microgravity, how the amplitudes of slosh reaction forces act on the Dewar with various rotating speeds, how the frequencies of the sloshing modes excited differ in terms of differences in rotating speeds, and how the sloshing dynamics differ with and without a baffle. The numerical computation of sloshing dynamics is based on the noninertial frame spacecraft-bound coordinates. Results of the simulations are illustrated.

Hung, R. J.↗

Precise Measurements of the Density and Critical Phenomena Near Phase Transitions in Liquid Helium

The first-year progress for the project of precise measurements of the density and critical phenomena of helium near phase transitions is summarized below: (1) completion of a cryogenic sample probe for the proposed measurements, and the rehabilitation of a designated laboratory at Caltech for this project; (2) construction and testing of a superconducting niobium cavity; (3) acquisition of one phase-locked-loop system for high-resolution frequency control and read- out; (4) setting up high-resolution thermometry (HRT) for temperature readout and control; (5) developing new approaches for calibrating the coefficient between the resonant frequency shift (delta f) and the helium density (rho), as well as for measuring the effect of gravity on T(sub lambda) to a much better precision; (6) programming of the interface control of all instruments for automatic data acquisition; and (7) improving data analyses and fitting procedures.

Yeh, Nai-Chang↗

Cryogenic Design of the Liquid Helium Experiment "Critical Dynamics in Microgravity"

Although many well controlled experiments have been conducted to measure the static properties of systems near criticality, few experiments have explored the transport properties in systems driven far away from equilibrium as a phase transition occurs. The cryogenic design of an experiment to study the dynamic aspect of critical phenomena is reported here. Measurements of the thermal gradient across the superfluid (He II)Юormal fluid (He I) interface in helium under microgravity conditions will be performed as a heat flux holds the system away from equilibrium. New technologies are under development for this experiment, which is in the definition phase for a space shuttle flight.

superfluid↗