Search NASA⌕ Search

SEARCH · Search NASA

Results for “Lookup table”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Interaction models and configurational entropies of binary MoTa and the MoNbTaW high entropy alloy

We introduce a simplified method to model the interatomic interactions of high entropy alloys based on a lookup table of cluster energies. Furthermore, these interactions are employed in replica exchange Monte Carlo simulations with histogram analysis to obtain thermodynamic properties across a broad temperature range. Kikuchi's cluster variation method entropy formalism is applied to directly calculate entropy from statistics on short- and long-range chemical order, and we discuss the convergence of the entropy as clusters of differing size are included. A high temperature series expansion aids in our understanding of the convergence. Computer codes implementing these methods, and supporting data, are freely available on the internet.

36 MATERIALS SCIENCE↗

Genetic Algorithm-Based Commutation Angle Control for Torque Ripple Mitigation in Switched Reluctance Motor Drives

This work addresses the application of the Genetic Algorithm (GA) technique to optimize the commutation angles of a 2 kW 8/6 switched reluctance machine (SRM). The primary goal is to reduce the well-known drawback of SRMs: the torque ripple. Firstly, the machine was modeled in Matlab /Simulink ® using lookup tables obtained via finite element method (FEM) simulations. Subsequently, the model was used to perform the GA routine aiming to find the optimal phase commutation angles that minimize the torque ripple factor. Notably, the torque performance of the SRM was significantly affected by the commutation angles during the search for the optimal solution. Afterwards, the GA results for four different operation points were verified experimentally through a developed drive platform with digital signal processor-based (DSP) control and an asymmetric bridge converter. As showed by the experiments, the proposed approach was suitable to reduce the torque ripple by more than 50% for one of the evaluated operating points. Furthermore, it was confirmed that the torque ripple mitigation led to acoustic noise improvement.

42 ENGINEERING↗

Fail-Safe Logic Design Strategies Within Modern FPGA Architectures

Fail-safe computing refers to computing systems that revert to a non-operational safe state when a fault occurs. In this paper, we investigate a circuit level technique as mitigation for single event upsets (SEUs) and fault injection attacks on field programmable gate arrays (FPGAs), and analyze the effectiveness of the technique as a fail-safe monitor for an encryption algorithm. The propagation of fault effects through FPGA primitives including lookup tables (LUTs) and programmable interconnect points (PIPs) is assessed within an FPGA architecture created using an open source tool, and validated using fault injection experiments on an FPGA. The analysis reveals additional vulnerabilities exist within reconfigurable architectures over those in equivalent fail-safe application specific integrated circuit (ASIC), thus requiring a more elaborate network of redundant circuits and checking logic. The configuration memory bits (CMBs), which configure routing and designate logic functions within the LUTs of the FPGA, add complexity to fail-safe design strategies by introducing additional fault conditions and fault propagation paths. A resource-efficient fail-safe circuit design technique called DEsign for Fail-safe in reCONfigurable systems (DEFCON) is proposed. The benefits and limitations associated with DEFCON are described in the context of fault injection experiments carried out as simulations and in FPGA hardware.

Bhakta, Priya A. [Univ. of New Mexico, Albuquerque↗

Optimal Coordination of Distributed Energy Resources Using Deep Deterministic Policy Gradient

Recent studies showed that reinforcement learning (RL) is a promising approach for coordination and control of distributed energy resources (DER) under uncertainties. Many existing RL approaches, including Q-learning and approximate dynamic programming, are based on lookup table methods, which become inefficient when the problem size is large and infeasible when continuous states and actions are involved. In addition, when modeling battery energy storage system (BESS), the loss of life is not reasonably considered into the decision-making process. This paper proposes an innovative deep RL method for DER coordination considering BESS degradation. The proposed deep RL is designed based on an adaptive actor-critic architecture and employs an off-policy deterministic policy gradient method for determining the dispatch operation that minimizes the operation cost and BESS life loss. Case studies were performed to validate the proposed method and demonstrate the effects of incorporating degradation models into control design.

Das, Avijit↗

Optimal Coordination of Electric Vehicles for Grid Services using Deep Reinforcement Learning

Recent research has shown the effectiveness of reinforcement learning (RL) in coordinating electric vehicles (EVs) with vehicle-to-grid capabilities for grid services. However, many of these studies rely on lookup table and deep Q-network techniques, which can be impractical when dealing with continuous states and actions. In addition, existing RL designs inadequately account for battery aging effects, EV user satisfaction, uncertain departure and arrival time, and trip distance, which may compromise effective coordination. This paper aims to bridge these gaps by developing an innovative deep deterministic policy gradient-based RL framework for optimal coordination of EVs. Case studies were carried out using a test system with 100 EVs, and numerical analysis results showed that the proposed RL framework can effectively coordinate EVs to maximize economic benefits and user satisfaction while ensuring the expected battery lifespan.

Das, Avijit↗

Neural network accelerator for quantum control

Efficient quantum control is necessary for practical quantum computing implementations with current technologies. Conventional algorithms for determining optimal control parameters are computationally expensive, largely excluding them from use outside of the simulation. Existing hardware solutions structured as lookup tables are imprecise and costly. By designing a machine learning model to approximate the results of traditional tools, a more efficient method can be produced. Such a model can then be synthesized into a hardware accelerator for use in quantum systems. In this study, we demonstrate a machine learning algorithm for predicting optimal pulse parameters. This algorithm is lightweight enough to fit on a low-resource FPGA and perform inference with a latency of 175 ns and pipeline interval of 5 ns with > 0.99 gate fidelity. In the long term, such an accelerator could be used near quantum computing hardware where traditional computers cannot operate, enabling quantum control at a reasonable cost at low latencies without incurring large data bandwidths outside of the cryogenic environment.

43 PARTICLE ACCELERATORS↗

Development of ROACH firmware for microwave multiplexed X-ray TES microcalorimeters

We are developing room temperature electronics based upon the ROACH platform for reading out microwave multiplexed X-ray TES. ROACH is an open-source hardware and software platform featuring a large Xilinx Field Programmable Gate Array (FPGA), Power PC processor, several 10GB Ethernet SFP+ interfaces, and a collection of daughter boards for analog signal generation and acquisition. The combination of a ROACH board, ADC/DAC conversion daughter boards, and hardware for RF mixing allows for the generation and capture of multiple RF tones for reading out microwave multiplexed x-ray TES microcalorimeters. The FPGA is used to generate multiple tones in base band, from 10MHz to 250MHz, which are subsequently mixed to RF in the multiple GHz range and sent through the microwave multiplexer. The tones are generated in the FPGA by storing a large lookup table in Quad Data Rate (QDR) SRAM modules and playing out the waveform to a DAC board. Once the signal has been modulated to RF, passed through the microwave multiplexer, and has been modulated back to base band, the signal is digitized by an ADC board. The tones are modulated to 0Hz by using a FPGA circuit consisting of a polyphase filter bank, several Xilinx FFT blocks, Xilinx CORDIC blocks (for converting to magnitude and phase), and special phase accumulator circuit for mixing to exactly 0Hz. Upwards of 256 channels can be simultaneously captured and written into a bank of 256 First-In-First-Out (FIFO) memories, with each FIFO corresponding to a channel. Individual channel data can be further processed in the FPGA before being streamed through a 10GB Ethernet fiber-optic interface to a Linux system. The Linux system runs software written in Python and QT C++ for controlling the ROACH system, capturing data, and processing data.

Firmware↗

Performance Optimization for Relative-Error-Bounded Lossy Compression on Scientific Data

Scientific simulations in high-performance computing (HPC) environments generate vast volume of data, which may cause a severe I/O bottleneck at runtime and a huge burden on storage space for postanalysis. Unlike traditional data reduction schemes such as deduplication or lossless compression, not only can error-controlled lossy compression significantly reduce the data size but it also holds the promise to satisfy user demand on error control. Pointwise relative error bounds (i.e., compression errors depends on the data values) are widely used by many scientific applications with lossy compression since error control can adapt to the error bound in the dataset automatically. Pointwise relative-error-bounded compression is complicated and time consuming. In this article, we develop efficient precomputation-based mechanisms based on the SZ lossy compression framework. Our mechanisms can avoid costly logarithmic transformation and identify quantization factor values via a fast table lookup, greatly accelerating the relative-error-bounded compression with excellent compression ratios. In addition, we reduce traversing operations for Huffman decoding, significantly accelerating the decompression process in SZ. Experiments with eight well-known real-world scientific simulation datasets show that our solution can improve the compression and decompression rates (i.e., the speed) by about 40 and 80 p, respectively, in most of cases, making our designed lossy compression strategy the best-in-class solution in most cases.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Numerical Investigation of a Central Fuel Property Hypothesis Under Boosted Spark-Ignition Conditions

In the present work, a central fuel property hypothesis (CFPH), which states that fuel properties are sufficient to provide an indication of a fuel’s performance irrespective of its chemical composition, was numerically investigated. In particular, the objective of the study was to determine whether Research Octane Number (RON) and Motor Octane Number (MON), as fuel properties, are sufficient to describe a fuel’s knock-limited performance under boosted spark-ignition (SI) conditions within the framework of CFPH. To this end, four TPRF-bioblendstock surrogates having different compositions but matched RON (=98) and MON (=90), were first generated using a non-linear regression model based on artificial neural network (ANN). Additionally, three unconventional bioblendstocks were included in the analysis: di-isobutylene (DIB), isobutanol, and Anisole. Skeletal reaction mechanisms were generated for the TPRF-DIB, TPRF-isobutanol, and TPRF-anisole blends from a detailed kinetic mechanism. Thereafter, numerical simulations were performed for the fuel surrogates using the skeletal mechanisms and a virtual cooperative fuel research (CFR) engine model, under a representative boosted operating condition. In the computational fluid dynamics (CFD) model, the G-equation approach was employed to track the turbulent flame front and the well-stirred reactor model combined with the multi-zone binning strategy was used to capture auto-ignition in the end-gas. In addition, laminar flame speed (LFS) was tabulated for each blend as a function of pressure, temperature, and equivalence ratio a priori, and the lookup tables were used to prescribe laminar flame speed as an input to the G-equation model. Parametric spark timing sweeps were performed for each fuel blend to determine the corresponding knock-limited spark advance (KLSA) and 50% burn point (CA50) at the respective KLSA timing. It was observed that despite same RON, MON, and engine operating conditions, the TPRF-anisole blend exhibited markedly different knock-limited performance from the other three blends. This deviation from the octane index (OI) expectation was shown to be caused by differences in laminar flame speed. However, it was found that relatively large fuel-specific differences in LFS (>20%) would have to be present to cause any appreciable deviation from the OI framework. Otherwise, RON and MON would still be robust enough to predict a fuel’s knock-limited performance.

42 ENGINEERING↗

Numerical Investigation of a Central Fuel Property Hypothesis under Boosted Spark-ignition Conditions

In the present work, a central fuel property hypothesis (CFPH), which states that fuel properties are sufficient to provide an indication of a fuel's performance irrespective of its chemical composition, was numerically investigated In particular, the objective of the study was to determine whether Research Octane Number (RON) and Motor Octane Number (MON), as fuel properties, are sufficient to describe a fuel's knock-limited performance under boosted spark-ignition (SI) conditions within the framework of CFPH. To this end, four TPRF-bioblendstock surrogates having different compositions but matched RON (= 98) and MON (= 90), were first generated using a non-linear regression model based on artificial neural network (ANN). Three unconventional bioblendstocks were included in the analysis: Di-isobutylene (DIB), Isobutanol and Anisole. Skeletal reaction mechanisms were generated for the TPRF-DIB, TPRF-isobutanol and TPRF-anisole blends from a detailed kinetic mechanism. Thereafter, numerical simulations were performed for the fuel surrogates using the skeletal mechanisms and a virtual cooperative fuel research (CFR) engine model, under a representative boosted operating condition. In the computational fluid dynamics (CFD) model, the G-equation approach was employed to track the turbulent flame front and the well-stirred reactor model combined with multi-zone binning strategy was used to capture auto-ignition in the end-gas. In addition, laminar flame speed was tabulated for each blend as a function of pressure, temperature and equivalence ratio a priori, and the lookup tables were used to prescribe laminar flame speed as an input to the G-equation model. Parametric spark timing sweeps were performed for each fuel blend to determine the corresponding knock-limited spark advance (KLSA) and 50% burn point (CA50) at the respective KLSA timing. It was observed that despite same RON, MON and engine operating conditions, the TPRF-Anisole blend exhibited markedly different knock-limited performance from the other three blends. This deviation from the octane index (DI) expectation was shown to be caused by differences in laminar flame speed (LFS). However; it was found that relatively large fuel-specific differences in LFS (> 20%) would have to be present to cause any appreciable deviation from the 01 framework. Otherwise, RON and MON would still be robust enough to predict a fuel's knock-limited performance.

Pal, Pinaki↗

The evolution of brachytherapy treatment planning

Brachytherapy is a mature treatment modality that has benefited from technological advances. Treatment planning has advanced from simple lookup tables to complex, computer-based dose-calculation algorithms. The current approach is based on the AAPM TG-43 formalism with recent advances in acquiring single-source dose distributions. However, this formalism has clinically relevant limitations for calculating patient dose. Dose-calculation algorithms are being developed based on Monte Carlo methods, collapsed cone, and solving the linear Boltzmann transport equation. In addition to improved dose-calculation tools, planning systems and brachytherapy treatment planning will account for material heterogeneities, scatter conditions, radiobiology, and image guidance. The AAPM, ESTRO, and other professional societies are working to coordinate clinical integration of these advancements. This Vision 20/20 article provides insight into these endeavors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A {gamma} dose distribution evaluation technique using the k-d tree for nearest neighbor searching

Purpose: The authors propose an algorithm based on the k-d tree for nearest neighbor searching to improve the {gamma} calculation time for 2D and 3D dose distributions. Methods: The {gamma} calculation method has been widely used for comparisons of dose distributions in clinical treatment plans and quality assurances. By specifying the acceptable dose and distance-to-agreement criteria, the method provides quantitative measurement of the agreement between the reference and evaluation dose distributions. The {gamma} value indicates the acceptability. In regions where {gamma}{<=}1, the predefined criterion is satisfied and thus the agreement is acceptable; otherwise, the agreement fails. Although the concept of the method is not complicated and a quick naieve implementation is straightforward, an efficient and robust implementation is not trivial. Recent algorithms based on exhaustive searching within a maximum radius, the geometric Euclidean distance, and the table lookup method have been proposed to improve the computational time for multidimensional dose distributions. Motivated by the fact that the least searching time for finding a nearest neighbor can be an O(log N) operation with a k-d tree, where N is the total number of the dose points, the authors propose an algorithm based on the k-d tree for the {gamma} evaluation in this work. Results: In the experiment, the authors found that the average k-d tree construction time per reference point is O(log N), while the nearest neighbor searching time per evaluation point is proportional to O(N{sup 1/k}), where k is between 2 and 3 for two-dimensional and three-dimensional dose distributions, respectively. Conclusions: Comparing with other algorithms such as exhaustive search and sorted list O(N), the k-d tree algorithm for {gamma} evaluation is much more efficient.

61 RADIATION PROTECTION AND DOSIMETRY↗

A spatially encoded dose difference maximal intensity projection map for patient dose evaluation: A new first line patient quality assurance tool

Purpose: To develop a spatially encoded dose difference maximal intensity projection (DD-MIP) as an online patient dose evaluation tool for visualizing the dose differences between the planning dose and dose on the treatment day. Methods: Megavoltage cone-beam CT (MVCBCT) images acquired on the treatment day are used for generating the dose difference index. Each index is represented by different colors for underdose, acceptable, and overdose regions. A maximal intensity projection (MIP) algorithm is developed to compress all the information of an arbitrary 3D dose difference index into a 2D DD-MIP image. In such an algorithm, a distance transformation is generated based on the planning CT. Then, two new volumes representing the overdose and underdose regions of the dose difference index are encoded with the distance transformation map. The distance-encoded indices of each volume are normalized using the skin distance obtained on the planning CT. After that, two MIPs are generated based on the underdose and overdose volumes with green-to-blue and green-to-red lookup tables, respectively. Finally, the two MIPs are merged with an appropriate transparency level and rendered in planning CT images. Results: The spatially encoded DD-MIP was implemented in a dose-guided radiotherapy prototype and tested on 33 MVCBCT images from six patients. The user can easily establish the threshold for the overdose and underdose. A 3% difference between the treatment and planning dose was used as the threshold in the study; hence, the DD-MIP shows red or blue color for the dose difference >3% or {<=}3%, respectively. With such a method, the overdose and underdose regions can be visualized and distinguished without being overshadowed by superficial dose differences. Conclusions: A DD-MIP algorithm was developed that compresses information from 3D into a single or two orthogonal projections while hinting the user whether the dose difference is on the skin surface or deeper.

60 APPLIED LIFE SCIENCES↗

A parameterization method and application in breast tomosynthesis dosimetry

Purpose: To present a parameterization method based on singular value decomposition (SVD), and to provide analytical parameterization of the mean glandular dose (MGD) conversion factors from eight references for evaluating breast tomosynthesis dose in the Mammography Quality Standards Act (MQSA) protocol and in the UK, European, and IAEA dosimetry protocols.Methods: MGD conversion factor is usually listed in lookup tables for the factors such as beam quality, breast thickness, breast glandularity, and projection angle. The authors analyzed multiple sets of MGD conversion factors from the Hologic Selenia Dimensions quality control manual and seven previous papers. Each data set was parameterized using a one- to three-dimensional polynomial function of 2–16 terms. Variable substitution was used to improve accuracy. A least-squares fit was conducted using the SVD.Results: The differences between the originally tabulated MGD conversion factors and the results computed using the parameterization algorithms were (a) 0.08%–0.18% on average and 1.31% maximum for the Selenia Dimensions quality control manual, (b) 0.09%–0.66% on average and 2.97% maximum for the published data by Dance et al. [Phys. Med. Biol. 35, 1211–1219 (1990); ibid. 45, 3225–3240 (2000); ibid. 54, 4361–4372 (2009); ibid. 56, 453–471 (2011)], (c) 0.74%–0.99% on average and 3.94% maximum for the published data by Sechopoulos et al. [Med. Phys. 34, 221–232 (2007); J. Appl. Clin. Med. Phys. 9, 161–171 (2008)], and (d) 0.66%–1.33% on average and 2.72% maximum for the published data by Feng and Sechopoulos [Radiology 263, 35–42 (2012)], excluding one sample in (d) that does not follow the trends in the published data table.Conclusions: A flexible parameterization method is presented in this paper, and was applied to breast tomosynthesis dosimetry. The resultant data offer easy and accurate computations of MGD conversion factors for evaluating mean glandular breast dose in the MQSA protocol and in the UK, European, and IAEA dosimetry protocols. Microsoft Excel™ spreadsheets are provided for the convenience of readers.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-E-17A-01: BEST IN PHYSICS (IMAGING) - Calculating SSDE From CT Exams Using Size Data Available in the DICOM Header of CT Localizer Radiographs

Purpose: To demonstrate the feasibility of using existing data stored within the DICOM header of certain CT localizer radiographs as a patient size metric for calculating CT size-specific dose estimates (SSDE). Methods: For most Siemens CT scanners, the CT localizer radiograph (topogram) contains a private DICOM field that stores an array of numbers describing AP and LAT attenuation-based measures of patient dimension. The square root of the product of the AP and LAT size data, which provides an estimate of water-equivalent-diameter (WED), was calculated retrospectively from topogram data of 20 patients who received clinically-indicated abdomen/pelvis (n=10) and chest (n=10) scans (WED-topo). In addition, slice-by-slice water-equivalent-diameter (WED-image) and effective diameter (ED-image) values were calculated from the respective image data. Using TG-204 lookup tables, size-dependent conversion factors were determined based upon WED-topo, WED-image and ED-image values. These conversion factors were used with the reported CTDIvol to calculate slice-by-slice SSDE for each method. Averaging over all slices, a single SSDE value was determined for each patient and size metric. Patientspecific SSDE and CTDIvol values were then compared with patientspecific organ doses derived from detailed Monte Carlo simulations of fixed tube current scans. Results: For abdomen/pelvis scans, the average difference between liver dose and CTDIvol, SSDE(WED-topo), SSDE(WED-image), and SSDE(ED-image) was 18.70%, 8.17%, 6.84%, and 7.58%, respectively. For chest scans, the average difference between lung dose and CTDIvol, SSDE(WED-topo), SSDE(WED-image), and SSDE(ED-image) was 25.80%, 3.33%, 4.11%, and 7.66%, respectively. Conclusion: SSDE calculated using WED derived from data in the DICOM header of the topogram was comparable to SSDE calculated using WED and ED derived from axial images; each of these estimated organ dose to within 10% for both abdomen/pelvis and chest CT examinations. The topogrambased method has the advantage that WED data are already provided and therefore available without additional post-processing of the image data. Funding Support: NIH Grant R01-EB017095; Disclosures - Michael McNitt-Gray: Institutional Research Agreement, Siemens AG; Research Support, Siemens AG; Consultant, Flaherty Sensabaugh Bonasso PLLC; Consultant, Fulbright and Jaworski; Disclosures - Cynthia McCollough: Research Grant, Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

WE-D-9A-06: Open Source Monitor Calibration and Quality Control Software for Enterprise Display Management

Purpose: Medical display monitor calibration and quality control present challenges to medical physicists. The purpose of this work is to demonstrate and share experiences with an open source package that allows for both initial monitor setup and routine performance evaluation. Methods: A software package, pacsDisplay, has been developed over the last decade to aid in the calibration of all monitors within the radiology group in our health system. The software is used to calibrate monitors to follow the DICOM Grayscale Standard Display Function (GSDF) via lookup tables installed on the workstation. Additional functionality facilitates periodic evaluations of both primary and secondary medical monitors to ensure satisfactory performance. This software is installed on all radiology workstations, and can also be run as a stand-alone tool from a USB disk. Recently, a database has been developed to store and centralize the monitor performance data and to provide long-term trends for compliance with internal standards and various accrediting organizations. Results: Implementation and utilization of pacsDisplay has resulted in improved monitor performance across the health system. Monitor testing is now performed at regular intervals and the software is being used across multiple imaging modalities. Monitor performance characteristics such as maximum and minimum luminance, ambient luminance and illuminance, color tracking, and GSDF conformity are loaded into a centralized database for system performance comparisons. Compliance reports for organizations such as MQSA, ACR, and TJC are generated automatically and stored in the same database. Conclusion: An open source software solution has simplified and improved the standardization of displays within our health system. This work serves as an example method for calibrating and testing monitors within an enterprise health system.

60 APPLIED LIFE SCIENCES↗

TH-C-BRD-09: Successes and Limitations of Online Range Adaptive Spot Scanning Proton Therapy for NSCLC

Purpose: To determine the ability to adapt discrete spot-scanning proton therapy (SSPT) plans based on geometric changes of anatomy to minimize normal tissue dose and maintain target coverage. Methods: We developed and tested a range-correction algorithm to compensate for anatomy changes in SSPT with correction factors for target lateral size changes and energy scaling. This algorithm adjusts the energy of each spot from the original optimized treatment plan to match the new daily anatomy based on water equivalent path-length. To correct for the lateral target size changes, the peripheral spots were scaled based on phantom studies with variable target size. For energy change corrections, alternative cumulative scaling factor lookup tables were generated based on calculated central-axis and integral depth dose calculations for different energies. These various adaptive algorithms were performed on 7 lung cancer patients that were previously treated with proton therapy and who required at least one adaptive intervention. Single-field optimized SSPT plans were generated for these patients with clinical beam angles. Dose-volume histogram metrics were obtained for these patients for both the non-adaptive and the different adaptive plans applied to the last available weekly CT scan. Results: The doses to normal tissue were largely reduced for the spinal cord (Dmax), total lung (V20Gy), and contralateral lung (V20Gy) for all different methods of adaptive planning. With both corrections applied, the average changes for these metrics were −6.2Gy, −2.7%, and −4.9%, respectively. The same method generated unacceptably high target hot spots with average target V110% increase of 12.3%. Conclusion: Adaptive methods based on direct adjustments to proton range can reduce normal tissue doses under large anatomical changes but are insufficient in achieving clinically acceptable target doses and generate unacceptably sizeable hot spots. Adaptive planning methods for proton therapy will likely necessitate some aspect of reoptimization for acceptable clinical utility.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 45: Comparison of different Monte Carlo methods of scoring linear energy transfer in modulated proton therapy beams

In this work, we demonstrate inconsistencies in commonly used Monte Carlo methods of scoring linear energy transfer (LET) in proton therapy beams. In particle therapy beams, the LET is an important parameter because the relative biological effectiveness (RBE) depends on it. LET is often determined using Monte Carlo techniques. We used a realistic Monte Carlo model of a proton therapy nozzle to score proton LET in spread-out Bragg peak (SOBP) depth-dose distributions. We used three different scoring and calculation techniques to determine average LET at varying depths within a 140 MeV beam with a 4 cm SOBP and a 250 MeV beam with a 10 cm SOBP. These techniques included fluence-weighted (Φ-LET) and dose-weighted average (D-LET) LET calculations from: 1) scored energy spectra converted to LET spectra through a lookup table, 2) directly scored LET spectra and 3) accumulated LET scored ‘on-the-fly’ during simulations. All protons (primary and secondary) were included in the scoring. Φ-LET was found to be less sensitive to changes in scoring technique than D-LET. In addition, the spectral scoring methods were sensitive to low-energy (high-LET) cutoff values in the averaging. Using cutoff parameters chosen carefully for consistency between techniques, we found variations in Φ-LET values of up to 1.6% and variations in D-LET values of up to 11.2% for the same irradiation conditions, depending on the method used to score LET. Variations were largest near the end of the SOBP, where the LET and energy spectra are broader.

07 ISOTOPE AND RADIATION SOURCES↗