Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Developing a Cyclotron Radiation Emission Spectroscopy Detection System

Cyclotron Radiation Emission Spectroscopy is a new technique for ultra-precise spectroscopy of low-energy electrons. This project aimed at developing capabilities that would be useful to a future CRES experiment. The recent results from the Project 8 and He6-CRES collaborations indicate that CRES has a promising future, but will need advancements to continue developing. In this report we cover the four tasks that comprised the project: data acquisition, data management, updating the raw-data format, a cloud computing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PROVABGS: The Probabilistic Stellar Mass Function of the BGS One-percent Survey

We present the probabilistic stellar mass function (pSMF) of galaxies in the DESI Bright Galaxy Survey (BGS), observed during the One-percent Survey. The One-percent Survey was one of DESI's survey validation programs conducted from 2021 April to May, before the start of the main survey. It used the same target selection and similar observing strategy as the main survey and successfully observed the spectra and redshifts of 143,017 galaxies in the r < 19.5 magnitude-limited BGS Bright sample and 95,499 galaxies in the fainter surface-brightness- and color-selected BGS Faint sample over z < 0.6. We derive pSMFs from posteriors of stellar mass, M*, inferred from DESI photometry and spectroscopy using the Hahn et al. PRObabilistic Value-Added BGS (PROVABGS) Bayesian spectral energy distribution modeling framework. We use a hierarchical population inference framework that statistically and rigorously propagates the M* uncertainties. Furthermore, we include correction weights that account for the selection effects and incompleteness of the BGS observations. We present the redshift evolution of the pSMF in BGS, as well as the pSMFs of star-forming and quiescent galaxies classified using average specific star formation rates from PROVABGS. Overall, the pSMFs show good agreement with previous stellar mass function measurements in the literature. Our pSMFs showcase the potential and statistical power of BGS, which in its main survey will observe >100 × more galaxies. Moreover, we present the statistical framework for subsequent population statistics measurements using BGS, which will characterize the global galaxy population and scaling relations at low redshifts with unprecedented precision.

79 ASTRONOMY AND ASTROPHYSICS↗

Stellar Mass Calibrations for Local Low-mass Galaxies

The stellar masses of galaxies are measured from integrated light via several methods—however, few of these methods were designed for low-mass (M ⋆ ≲ 10 8 M ⊙ ) “dwarf” galaxies, whose properties (e.g., stochastic star formation, low metallicity) pose unique challenges for estimating stellar masses. In this work, we quantify the precision and accuracy at which stellar masses of low-mass galaxies can be recovered using UV/optical/IR photometry. We use mock observations of 469 low-mass galaxies from a variety of models, including both semi-empirical models (GRUMPY and UniverseMachine-SAGA) and cosmological baryonic zoom-in simulations (MARVELous Dwarfs and FIRE-2), to test literature color–M ⋆ /L relations and multiwavelength spectral energy distribution (SED) mass estimators. We identify a list of “best practices” for measuring stellar masses of low-mass galaxies from integrated photometry. We find that literature color–M ⋆ /L relations are often unable to capture the bursty star formation histories (SFHs) of low-mass galaxies, and we develop an updated prescription for stellar mass based on g − r color that is better able to recover stellar masses for the bursty low-mass galaxies in our sample (with ∼0.1 dex precision). SED fitting can also precisely recover stellar masses of low-mass galaxies, but this requires thoughtful choices about the form of the assumed SFH: Parametric SFHs can underestimate stellar mass by as much as ∼0.4 dex, while nonparametric SFHs recover true stellar masses with insignificant offset (−0.03 ± 0.11 dex). Finally, we also caution that noninformative (wide) dust attenuation priors may introduce M ⋆ uncertainties of up to ∼0.6 dex.

de los Reyes, Mithi A. C. [Amherst College, MA (Un↗

Quantitative Electron Beam‐Single Atom Interactions Enabled by Sub‐20‐pm Precision Targeting

The ability to probe and control matter at the picometer scale is essential for advancing quantum and energy technologies. Scanning transmission electron microscopy offers powerful capabilities for materials analysis and modification, but sample damage, drift, and scan distortions hinder single atom analysis and deterministic manipulation. Materials analysis and modification via electron–solid interactions can be transformed by precise delivery of electrons to a specified atomic location, maintaining the beam position despite drift, and minimizing collateral dose. Here a fast, low-dose, sub-20-pm precision electron beam positioning technique is developed, “atomic lock-on,” (ALO), which offers the ability to position the beam on a specific atomic column without previously irradiating that column. This technique is used to lock onto a single selected atomic location to repeatedly measure its weak electron energy loss signal despite sample drift. Moreover, electron beam-matter interactions in single atomic events are measured with μ s time resolution. This enables observation of single-atom dynamics, such as atomic bistability, revealing partially bonded atomic configurations and recapture phenomena. This opens prospects for using electron microscopy for high-precision measurements and deterministic control of matter for quantum technologies.

2D materials↗

Low-loss low thermo-optic coefficient Ta 2 O 5 on crystal quartz planar optical waveguides

Optical resonator-based frequency stabilization plays a critical role in ultra-low linewidth laser emission and precision sensing, atom clocks, and quantum applications. However, there has been limited success in translating traditional bench-top stabilization cavities to compact on-chip integrated waveguide structures that are compatible with photonic integration. The challenge lies in realizing waveguides that not only deliver low optical loss but also exhibit a low thermo-optic coefficient and frequency noise stability. Given the problematic sources of frequency noise within dielectrics, such as thermorefractive noise, resonators with small thermo-optic response are desirable for on-chip reference cavities. We report the first demonstration of a Ta 2 O 5 (tantala) waveguide core fabricated on a crystal quartz substrate lower cladding with TEOS-PECVD SiO 2 upper cladding. This waveguide offers significant advantages over other waveguides in terms of its low thermo-optic coefficient and reduced thermorefractive-related frequency noise. We describe the waveguide structure and key design parameters as well as fabrication considerations for processing tantala on quartz waveguides. We report a waveguide thermo-optic coefficient of -1.14 × 10 -6 RIU/K, a value that is over 6 times smaller in magnitude than that of SiO 2 -substrate tantala waveguides, with a propagation loss of 1.19 dB/cm at 1550 nm and <1.33 dB/cm across the 1525 nm–1610 nm wavelength range. Within a 1.6 mm radius ring resonator, we demonstrate a 2.54 × 10 5 intrinsic Q factor. With the potential for very low loss and the ability to control the thermal response, this waveguide platform takes a key step toward creating thermally stable integrated resonators for on-chip laser frequency stabilization and other applications.

42 ENGINEERING↗

Precision measurement of Compton scattering in silicon with a skipper CCD for dark matter detection

Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $\gamma$-rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a precision measurement of Compton scattering on silicon atomic shell electrons down to 23$\,$eV. A skipper charge-coupled device (CCD) with single-electron resolution, developed for the DAMIC-M experiment, was exposed to a $^{241}$Am $\gamma$-ray source over several months. Features associated with the silicon K, L$_{1}$, and L$_{2,3}$-shells are clearly identified, and scattering on valence electrons is detected for the first time below 100$\,$eV. We find that the relativistic impulse approximation for Compton scattering, which is implemented in Monte Carlo simulations commonly used by direct detection experiments, does not reproduce the measured spectrum below 0.5$\,$keV. The data are in better agreement with $ab$$initio$ calculations originally developed for X-ray absorption spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision test of gauge/gravity duality in D0-brane matrix model at low temperature

We test the gauge/gravity duality between the matrix model and type IIA string theory at low temperatures with unprecedented accuracy. To this end, we perform lattice Monte Carlo simulations of the Berenstein-Maldacena-Nastase (BMN) matrix model, which is the one-parameter deformation of the Banks-Fischler-Shenker-Susskind (BFSS) matrix model, taking both the large N and continuum limits. We leverage the fact that sufficiently small flux parameters in the BMN matrix model have a negligible impact on the energy of the system while stabilizing the flat directions so that simulations at smaller N than in the BFSS matrix model are possible. Hence, we can perform a precision measurement of the large N continuum energy at the lowest temperatures to date. The energy is in perfect agreement with supergravity predictions including estimations of α'-corrections from previous simulations. At the lowest temperature where we can simulate efficiently (T = 0.25λ 1/3 , where λ is the ’t Hooft coupling), the difference in energy to the pure supergravity prediction is less than 10%. Furthermore, we can extract the coefficient of the 1/N 4 corrections at a fixed temperature with good accuracy, which was previously unknown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determination of Sodium Abundance Ratio from Low-resolution Stellar Spectra and Its Applications

We present a method to determine sodium abundance ratios ([Na/Fe]) using the Na i D doublet lines in low-resolution (R ~ 2000) stellar spectra. As stellar Na i D lines are blended with those produced by the interstellar medium, we developed a technique for removing the interstellar Na I D lines using the relationship between extinction, which is proportional to E(B – V), and the equivalent width of the interstellar Na i D absorption lines. When measuring [Na/Fe], we also considered corrections for nonlocal thermodynamic equilibrium (NLTE) effects. Comparisons with data from high-resolution spectroscopic surveys suggest that the expected precision of [Na/Fe] from low-resolution spectra is better than 0.3 dex for stars with [Fe/H] > –3.0. We also present a simple application employing the estimated [Na/Fe] values for a large number of stellar spectra from the Sloan Digital Sky Survey (SDSS). After classifying the SDSS stars into Na-normal, Na-high, and Na-extreme, we explore their relation to stars in Galactic globular clusters (GCs). We find that while the Na-high SDSS stars exhibit a similar metallicity distribution function (MDF) to that of the GCs, indicating that the majority of such stars may have originated from GC debris, the MDF of the Na-normal SDSS stars follows that of typical disk and halo stars. As there is a high fraction of carbon-enhanced metal-poor stars among the Na-extreme stars, they may have a non-GC origin, perhaps due to mass-transfer events from evolved binary companions.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum-enhanced detection of viral cDNA via luminescence resonance energy transfer using upconversion and gold nanoparticles

Abstract The COVID-19 pandemic has profoundly impacted global economies and healthcare systems, revealing critical vulnerabilities in both. In response, our study introduces a sensitive and highly specific detection method for cDNA, leveraging Luminescence Resonance Energy Transfer (LRET) between upconversion nanoparticles (UCNPs) and gold nanoparticles (AuNPs), and achieves a detection limit of 242 fM for SARS-CoV-2 cDNA. This innovative sensing platform utilizes UCNPs conjugated with one primer and AuNPs with another, targeting the 5′ and 3′ ends of the SARS-CoV-2 cDNA, respectively, enabling precise differentiation of mismatched cDNA sequences and significantly improving detection specificity. Through rigorous experimental analysis, we established a quenching efficiency range from 10.4 % to 73.6 %, with an optimal midpoint of 42 %, thereby demonstrating the superior sensitivity of our method. Our work uses SARS-CoV-2 cDNA as a model system to demonstrate the potential of our LRET-based detection method. This proof-of-concept study highlights the adaptability of our platform for future diagnostic applications. Instrumental validation confirms the synthesis and formation of AuNPs, addressing the need for experimental verification of the preparation of nanomaterial. Our comparative analysis with existing SARS-CoV-2 detection methods revealed that our approach provides a low detection limit and high specificity for target cDNA sequences, underscoring its potential for targeted COVID-19 diagnostics. This study demonstrates the superior sensitivity and adaptability of using UCNPs and AuNPs for cDNA detection, offering significant advances in rapid, accessible diagnostic technologies. Our method, characterized by its low detection limit and high precision, represents a critical step forward in developing next-generation biosensors for managing current and future viral outbreaks. By adjusting primer sequences, this platform can be tailored to detect other pathogens, contributing to the enhancement of global healthcare responsiveness and infectious disease control.

Esmaeili, Shahriar [Institute for Quantum Science ↗

High precision fundamental physics experiments using compact spin-transparent storage rings of low energy polarized electron beams

We present a new design of highly specialized small storage rings for low energy polarized electron beams. The new design is based on the transparent spin methodology that cancels the spin precession due to the magnetic dipole moment at any energy while allowing for spin precession induced by the fundamental physics of interest to accumulate. The buildup of the vertical component of beam polarization can be measured using standard Mott polarimetry that is optimal at low electron energy. These rings can be used to measure the permanent electric dipole moment of the electron, relevant to CP violation and matter-antimatter asymmetry in the universe, and to search for dark energy and ultra-light dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reactions of atomic thorium and uranium cations with CF 4 studied by guided ion beam tandem mass spectrometry

The fundamental chemistry of the actinides continues to be an area of interest because of their use in nuclear fuel cycles. Here, the kinetic energy dependences of the reactions of thorium and uranium cations with CF 4 were studied using guided ion beam tandem mass spectrometry. The products observed include AnF x + (An = Th or U, x = 1-3) and CF y + (y = 1-3). Although most reactions are exothermic according to literature thermochemistry, all cross sections display strong endothermic features indicating a restriction in the reactivity at low energies. For both actinides, only the AnF + + CF 3 product channel is observed at low energies; however, its formation proceeds very inefficiently. Furthermore, these results indicate that the reactions of Th + and U + with CF 4 are not thermodynamically driven and suggest that the low-energy reactivity results from precise alignment of the reactants.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of methods for the NMR measurement of motionally averaged dipolar couplings

Motionally averaged dipolar couplings are an important tool for understanding the complex dynamics of catalysts, polymers, and biomolecules. While there is a plethora of solid-state NMR pulse sequences available for their measurement, in can be difficult to gauge the methods’ strengths and weaknesses. In particular, there has not been a comprehensive comparison of their performance in natural abundance samples, where 1H homonuclear dipolar couplings are important and the use of large MAS rotors may be required for sensitivity reasons. In this work, we directly compared some of the more common methods for measuring C–H dipolar couplings in natural abundance samples using L-alanine (L-Ala) and the N-formyl-L-methionyl-L-leucyl-L-phenylalanine (fMLF) tripeptide as model systems. Here, we evaluated their performance in terms of accuracy, resolution, sensitivity, and ease of implementation. We found that, despite the presence of 1H homonuclear dipolar interactions, all methods, with the exception of REDOR, were able to yield the reasonable dipolar coupling strengths for both mobile and static moieties. Of these methods, PDLF provides the most convenient workflow and precision at the expense of low sensitivity. In low-sensitivity cases, MAS-PISEMA and DIPSHIFT appear to be the better options.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A custom high-stability pulse generator for the test of a novel in-situ magnetic sensor developed to detect radiation damage in undulators

High-performance analog-to-digital converters (ADC) have been widely applied in many areas of science. For instance, magnetic field measurements based on the Faraday’s induction law require high-precision voltmeters to measure induced voltages. In this study in the context of free-electron lasers technology, the Magnetic Measurements Team at SLAC National Accelerator Laboratory proposed a novel in-situ radiation damage detection system (RDDS) for detecting small field variations in undulators. The system measures the flux change in a flexible printed-circuit coil attached to the magnet array during the undulator gap movement. The gap movement changes the magnetic field, which induces a voltage signal in the coil that is measured and integrated with an ADC. Although the system is capable of detecting relative flux changes better than 100 ppm, drift in the ADC’s gain or offset can cause apparent changes in the relative flux. This paper describes the first attempt to developed a high-precision verification circuit to perform ADC testing in the framework of the novel RDDS. The circuit generates a reference voltage pulse with a voltage–time integral relative precision better than 50 ppm for a few hundreds of mVs — the typical order of magnitude measured with the RDDS. The circuit’s design combines a fast and precise switch with a low-noise voltage reference. Long-term measurements allowed statistical analysis and showed that averaging the voltage–time integral of ten pulses gives the required 50 ppm stability. Moreover, reproducibility tests confirmed that the circuit’s output is invariable under small power supply instabilities and equipment shutdown. Instruments and applications designed to quantify the magnetic field by integrating voltage signals may use the pulse generator proposed in this paper for verification purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined analysis of HPK 3.1 LGADs using a proton beam, beta source, and probe station towards establishing high volume quality control

The upgrades of the CMS and ATLAS experiments for the high luminosity phase of the Large Hadron Collider will employ precision timing detectors based on Low Gain Avalanche Detectors (LGADs). We present a suite of results combining measurements from the Fermilab Test Beam Facility, a beta source telescope, and a probe station, allowing full characterization of the HPK type 3.1 production of LGAD prototypes developed for these detectors. We demonstrate that the LGAD response to high energy test beam particles is accurately reproduced with a beta source. Finally, we further establish that probe station measurements of the gain implant accurately predict the particle response and operating parameters of each sensor, and conclude that the uniformity of the gain implant in this production is sufficient to produce full-sized sensors for the ATLAS and CMS timing detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion-Assisted Nanoscale Material Engineering in Atomic Layers

Achieving deterministic control over the properties of low-dimensional materials with nanoscale precision is a long-sought goal. Mastering this capability has a transformative effect on the design of multifunctional electrical and optical devices. Here, we present an ion-assisted synthetic technique that enables precise control over the material composition and energy landscape of two-dimensional (2D) atomic crystals. Our method transforms binary transition-metal dichalcogenides, like MoSe2, into ternary MoS2αSe2(1-α) alloys with systematically adjustable compositions, α. By piecewise assembly of the lateral, compositionally modulated MoS2αSe2(1-α) segments within 2D atomic layers, we present a synthetic pathway toward the realization of multicompositional designer materials. Our technique enables the fabrication of advanced 2D structures with arbitrary boundaries, dimensions as small as 30 nm, and fully customizable energy landscapes. Our optical characterizations further showcase the potential for implementing tailored optoelectronics in these engineered 2D crystals.

2D materials↗

Ab initio polaritonic potential-energy surfaces for excited-state nanophotonics and polaritonic chemistry

Advances in nanophotonics, quantum optics, and low-dimensional materials have enabled precise control of light–matter interactions down to the nanoscale. Combining concepts from each of these fields, there is now an opportunity to create and manipulate photonic matter via strong coupling of molecules to the electromagnetic field. Toward this goal, here we demonstrate a first principles framework to calculate polaritonic excited-state potential-energy surfaces, transition dipole moments, and transition densities for strongly coupled light–matter systems. In particular, we demonstrate the applicability of our methodology by calculating the polaritonic excited-state manifold of a formaldehyde molecule strongly coupled to an optical cavity. This proof-of-concept calculation shows how strong coupling can be exploited to alter photochemical reaction pathways by influencing avoided crossings with tuning of the cavity frequency and coupling strength. Therefore, by introducing an ab initio method to calculate excited-state potential-energy surfaces, our work opens a new avenue for the field of polaritonic chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Instantaneous difference frequency locking observed during toroidicity-induced Alfvén eigenmode coupling in the DIII-D tokamak

In magnetic confinement fusion, toroidicity-induced Alfvén eigenmodes (TAEs) are well-studied, weakly stable solutions of the linearized ideal magnetohydrodynamic equations. Driven unstable by suprathermal populations of energetic particles, TAE pose a key vulnerability to the confinement of high-energy alpha particles generated by fusion reactions. Hence, it is paramount to understand TAE dynamics if a working reactor is to be realized. In this work, we detect and characterize signatures of nonstationary nonlinear coupling between TAE using a novel, time-resolved bispectral analysis; results are supported by analytic signal of band-passed data. Crucially, a stationary phase relationship between two TAE and a nascent low frequency fluctuation is observed precisely when the triple product of magnetic fluctuation amplitudes is enhanced. Local mode number and frequency spectrum, gleaned from beam-emission spectroscopy, corroborates simultaneous satisfaction of nonlinear matching conditions, and provides a tool to identify theorized pathways of energy transfer, e.g. TAE parametric instability.

bispectral analysis↗

Measurements of time and spatial resolution of AC-LGADs with different designs

AC-LGAD sensors are prime candidates for fast and precise measurement of charged particles in a variety of applications. In a fine-pitched pixel or strip AC-LGAD sensor, the signal generated by the passage of a particle is not localized in a limited volume in the sensor, but is shared among multiple electrodes. This signal sharing characteristic allows us to improve the spatial resolution of AC-LGAD sensors beyond the capabilities of common silicon trackers. Since the magnitude of the shared signal depends on the distance between the pixels or strips and the point of passage of the particle, signal sharing is strongly influenced by the geometry of the sensor. The electrode pitch and gap size as well as the shape can be fine tuned to maximize the space resolution, while keeping the detector granularity and the number of channels to be read out under control. Prototypes of AC-LGAD sensors produced at the Brookhaven National Laboratory covering a variety of possible geometries have been studied via Transient Current Technique using an infrared laser, and the signal sharing, spatial resolution, and time resolution of the different topologies have been measured. These results have been compared with measurements performed in test-beams with 120 GeV protons at the Fermilab Test Beam Facility. A time resolution of ~30 ps can be achieved using AC-LGAD sensors with a thickness of 50 μm, compatible to that of standard DC-coupled LGADs, while presenting a far superior spatial resolution. Finally, this combination of high precision, fast timing capabilities, and low material budget makes AC-LGADs an ideal choice for a truly 4D detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗