Large low background kTon-scale liquid argon time projection chambers

Here we find that it is possible to increase sensitivity to low energy physics in a third or fourth Deep Underground Neutrino Experiment (DUNE)-like module with careful controls over radiopurity and targeted modifications to a detector similar to the DUNE Far Detector design. In particular, sensitivity to supernova and solar neutrinos can be enhanced with improved MeV-scale reach. A neutrinoless double beta decay search with 136 Xe loading appears feasible. Furthermore, sensitivity to Weakly-Interacting Massive Particle (WIMP) Dark Matter becomes competitive with the planned world program in such a detector, offering a unique seasonal variation detection that is characteristic of the nature of WIMPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid Detector (Final Technical Report)

We report updates since the first demonstration of a phonon-mediated silicon detector technology that provides a primary phonon measurement in a low-voltage region, and a simultaneous indirect measurement of the ionization signal through Neganov–Trofimov–Luke amplification in a high voltage region, both in a monolithic crystal. We present characterization of charge and phonon transport between the two stages of the detector and the resulting background discrimination capability at low energies. This new detector technology has the potential to significantly enhance the sensitivity of dark matter and coherent neutrino scattering experiments beyond the capabilities of current technologies that have limited discrimination at low energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision measurement of Compton scattering in silicon with a skipper CCD for dark matter detection

Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $\gamma$-rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a precision measurement of Compton scattering on silicon atomic shell electrons down to 23$\,$eV. A skipper charge-coupled device (CCD) with single-electron resolution, developed for the DAMIC-M experiment, was exposed to a $^{241}$Am $\gamma$-ray source over several months. Features associated with the silicon K, L$_{1}$, and L$_{2,3}$-shells are clearly identified, and scattering on valence electrons is detected for the first time below 100$\,$eV. We find that the relativistic impulse approximation for Compton scattering, which is implemented in Monte Carlo simulations commonly used by direct detection experiments, does not reproduce the measured spectrum below 0.5$\,$keV. The data are in better agreement with $ab$$initio$ calculations originally developed for X-ray absorption spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study of sacrificial mirrors for use prior to a laser wakefield accelerator driven by the Z-Petawatt laser

Many experiments at Sandia’s Z Pulsed Power Facility require x-ray backlighting diagnostics to understand experiment performance. Due to limitations in present-day source/detection modalities, most x-ray diagnostics at Z are restricted to photon energies <20 keV, ultimately limiting the density, amount, and atomic number of targets diagnosable in experiments. These limitations force the use of low-Z materials like Beryllium, and they prevent acquisition of important backlighting data for materials/densities that are opaque to soft x-rays and where background emission from the Z load and transmission lines overwhelm diagnostics. In this LDRD project, we have investigated the design and development of a laser wakefield acceleration platform driven by the Z-Petawatt laser – a platform that would enable the generation of a pulsed, collimated beam of high energy x-rays up to 100 keV. Geometrical considerations for implementation on the Z Machine require the use of sacrificial mirrors, which have been tested in offline experiments in the Chama target chamber in building 983. Our results suggest the use of sacrificial mirrors would not necessarily inhibit the laser wakefield x-ray process, particularly with the benefits stemming from planned laser upgrades. These conclusions support the continuation of laser wakefield source research and the development of the necessary infrastructure to deliver the Z-Petawatt laser to the Z center section along the appropriate lines of sight. Ultimately, this new capability will provide unprecedented views through dense states of matter, enabling the use of previously incompatible target materials/designs, and uncovering a new set of observables accessible through diffraction and spectroscopy in the hard x-ray regime. These will amplify the data return on precious Z shots and enhance Sandia’s ability to investigate fundamental physics in support of national security.

43 PARTICLE ACCELERATORS↗

The Mu2e straw tracker detector status and prototype results

The Mu2e experiment will search for charge-lepton flavor violating (CLFV) muon to electron conversion. It aims to achieve a four-orders of magnitude improvement in sensitivity over previous experiments, allowing it to probe new physics at mass scales up to 10 4 TeV . A precision momentum measurement is needed to resolve the monoenergetic electron that is the signal of CLFV conversion from muon decay-in-orbit backgrounds. Here, this is achieved in Mu2e using a low-mass cylindrical straw tracker operated in vacuum, consisting of 21,000 thin-wall mylar straws held at tension. The Mu2e tracker is now in production and will be completed during 2025. We will discuss the design and status of the experiment and the tracker detector, and show results from data taken with the first tracker module.

Gaseous detector↗

The pathfinder X-Ray axion telescope for the International Axion Observatory (IAXO) and axion searches at the CERN Axion Solar Telescope (CAST)

The axion, a hypothetical pseudo-scalar particle proposed by Peccei and Quinn to resolve the strong CP problem in quantum chromodynamics, remains one of the most compelling dark matter candidates. Axions and Axion-Like Particles (ALPs) are characterized by a broad and largely unconstrained parameter space in mass and coupling strength, motivating extensive experimental searches. The International Axion Observatory (IAXO) is a next-generation axion helioscope designed to achieve over an order of magnitude improvement in sensitivity to the axion-photon coupling constant gaγ relative to previous experiments such as the CERN Axion Solar Telescope (CAST). IAXO will employ large-scale superconducting magnets, precision x-ray optics, and ultra-low-background detectors to search for solar axions produced primarily via the Primakoff effect. This work presents the design and performance of the IAXO pathfinder x-ray optic, a technological demonstrator that validated the optical concepts for IAXO through axion searches at CAST. Comprehensive ray-tracing simulations and experimental measurements were conducted to assess the optic's effective area, detection efficiency, and background suppression capabilities. Deployed at CAST in conjunction with Micromegas and GridPix detectors, the Pathfinder demonstrated record-setting sensitivity to both gaγ and the axion-electron coupling gae, establishing the most stringent laboratory constraints on solar axions to date. These results confirm the viability of the IAXO optical design and detector concept, providing a critical technological benchmark that informs the ongoing development of the BabyIAXO and full-scale IAXO telescopes.

47 OTHER INSTRUMENTATION↗

Sensitivity of ultralight axion dark matter search with optical quantum sensors

An optical quantum sensor (OQS) based on lasers and alkali-metal atoms is a sensitive ambient-temperature magnetometer that can be used in axion dark matter search with an inductor-capacitor (LC) circuit at kHz and MHz frequencies. We have previously investigated the sensitivity of an LC circuit-OQS axion detector to ultralight axion dark matter that could be achieved using a fT-noise OQS constructed in our lab. In this paper, we investigate the sensitivity that could be potentially reached by an OQS performing close to the fundamental quantum noise levels of 10 aT / $\sqrt{Hz}$. To take advantage of the quantum-limited OQS, the LC circuit has to be made of a superconductor and cooled to low temperature of a few K. After considering the intrinsic noise of the advanced axion detector and characterizing possible background noises, we estimate that such an experiment could probe benchmark QCD axion models in an unexplored mass range near 10 neV. Reaching such a high sensitivity is a difficult task, so we have conducted some preliminary experiments with a large-bore magnet and a prototype axion detector consisting of a room-temperature LC circuit and a commercial OQS unit. In conclusion, this paper describes the prototype experiment and its projected sensitivity to axions in detail.

79 ASTRONOMY AND ASTROPHYSICS↗

Pushing the Limits of Pulse Shape Discrimination in a Large Liquid Xenon Detector

The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is differentiating between WIMP signals and background events. In LZ, the ratio of ionization to scintillation signals (charge-to-light) is the primary method for rejecting electronic recoil (ER) background. Pulse shape discrimination (PSD) offers a method for additional ER backgrounds rejection in liquid xenon detectors. In this paper, the discrimination power of PSD with the LZ experiment is discussed. To precisely characterize the scintillation pulse shape, an analysis framework is developed to reconstruct the detection time of individual photons. Using LZ calibration data, the photon-timing prompt fraction discriminator is optimized and achieves ER leakage as low as $15\%$. For specific background processes such as $^{124}$Xe double electron capture, the leakage is reduced further to about $5\%$. PSD is combined with charge-to-light to form two-factor discrimination (TFD). The optimized TFD performance is compared with the performance of the charge-to-light method, with the corresponding false positive rate reduced by up to a factor of two for large scintillation pulses. Finally, PSD and TFD are applied to data from LZ's WS2024 run and their performance is summarized.

Akerib, D. S. [SLAC; KIPAC, Menlo Park]↗

Pursuing the Ultimate Power of Xenon Dark Matter Detectors (Annual Progress Report)

Liquid xenon-based experiments have been leading direct searches for dark matter – a cornerstone of modern cosmology and particle physics. Despite rapid improvement of experimental sensitivities in the past two decades, no definitive dark matter interactions have been observed. This project aims to expand the physics reach of existing and future xenon dark matter experiments, especially for low-mass dark matter interactions that would fall below the energy thresholds of current detectors. The main approach is to thoroughly characterize and to suppress the low-energy electron background observed in dual-phase xenon Time Projection Chambers (TPCs), which has so far prevented these detectors from achieving lower energy thresholds. Per recent discussion with and approval from the program manager, we have added a new task of experimentally measuring the Migdal effect to this project. The Migdal effect predicts that ultra-low energy dark matter interactions may produce detectable electron recoil signals in liquid xenon at the keV level in addition to much lower energy nuclear recoils. If this effect is experimentally measured, it will drastically improve xenon detectors’ sensitivity to subGeV dark matter interactions. This new task shares strong synergy with the original project goal of pursuing the ultimate power of xenon dark matter experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of cosmogenic activation above ground for the DarkSide-20k experiment

The activation of materials due to exposure to cosmic rays may become an important background source for experiments investigating rare event phenomena. DarkSide-20k, currently under construction at the Laboratori Nazionali del Gran Sasso, is a direct detection experiment for galactic dark matter particles, using a two-phase liquid-argon Time Projection Chamber (TPC) filled with 49.7 tonnes (active mass) of Underground Argon (UAr) depleted in 39 Ar. Despite the outstanding capability of discriminating γ / β background in argon TPCs, this background must be considered because of induced dead time or accidental coincidences mimicking dark-matter signals and it is relevant for low-threshold electron-counting measurements. Here, the cosmogenic activity of relevant long-lived radioisotopes induced in the experiment has been estimated to set requirements and procedures during preparation of the experiment and to check that it is not dominant over primordial radioactivity; particular attention has been paid to the activation of the 120 t of UAr used in DarkSide-20k. Expected exposures above ground and production rates, either measured or calculated, have been considered in detail. From the simulated counting rates in the detector due to cosmogenic isotopes, it is concluded that activation in copper and stainless steel is not problematic. The activity of 39 Ar induced during extraction, purification and transport on surface is evaluated to be 2.8% of the activity measured in UAr by DarkSide-50 experiment, which used the same underground source, and thus considered acceptable. Other isotopes in the UAr such as 37 Ar and 3 H are shown not to be relevant due to short half-life and assumed purification methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pushing the limits of pulse shape discrimination in a large liquid xenon detector

Abstract The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is differentiating between WIMP signals and background events. In LZ, the ratio of ionization to scintillation signals (charge-to-light) is the primary method for rejecting electronic recoil (ER) background. Pulse shape discrimination (PSD) offers a method for additional ER backgrounds rejection in liquid xenon detectors. In this paper, the discrimination power of PSD with the LZ experiment is discussed. To precisely characterize the scintillation pulse shape, an analysis framework is developed to reconstruct the detection time of individual photons. Using LZ calibration data, the photon-timing tail fraction discriminator is optimized and achieves ER leakage as low as $$15\%$$ 15 % . For specific background processes such as $$^{124}$$ 124 Xe double electron capture, the leakage is reduced further to about $$5\%$$ 5 % . PSD is combined with charge-to-light to form two-factor discrimination (TFD). The optimized TFD performance is compared with the performance of the charge-to-light method, with the corresponding false positive rate reduced by up to a factor of two for large scintillation pulses. Finally, PSD and TFD are applied to data from LZ’s WS2024 run and their performance is summarized.

Akerib, D. S. [SLAC National Accelerator Laborator↗

Neutron capture-induced nuclear recoils as background for CE$v$⁢NS measurements at reactors

Nuclear reactors represent a promising neutrino source for CE⁢v⁢NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can create a spectrum that strongly overlaps the CEv⁢NS signal for recoils ≲100 eV for nuclear reactor measurements in silicon or germanium detectors. This background can be particularly critical for low-power research reactors providing a moderate neutrino flux. Here, in this work we quantify the impact of this background and show that, for a measurement 10 m from a 1 MW reactor, the effective thermal neutron flux should be kept below ~7 × 10 –4 ⁢n/cm 2 s so that the CE⁢v⁢NS events can be measured at least at a 5⁢σ level with germanium detectors in 100 kg yr exposure time. This flux corresponds to 60% of the sea-level flux but needs to be achieved in a nominally high-flux (reactor) environment. Improved detector resolution can help the measurements, but the thermal flux is the key parameter for the sensitivity of the experiment. For silicon detectors, the constraint is even stronger and thermal neutron fluxes must be near an order of magnitude lower. This constraint highlights the need of an effective thermal neutron mitigation strategy for future low threshold CEv⁢NS searches. In particular, the neutron capture-induced background can be efficiently reduced by active veto systems tagging the deexcitation gamma following the capture.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring the molecular Migdal effect with neutron scattering on diatomic gases

The Migdal effect is a key inelastic signal channel which could be used to detect low-mass dark matter, but it has never been observed experimentally using Standard Model probes. Here we propose a conceptual design for an experiment which could detect the Migdal effect in diatomic molecules through low-energy neutron scattering, and we provide the requirements on the beam spectrum and reducible backgrounds such that a detection may be achieved. The enhancement of the Migdal rate through non-adiabatic couplings, which are absent in isolated atoms, combined with the distinctive photon energies of electronic transitions in CO, suggest that a positive detection of the molecular Migdal effect may be possible with modest beam times at existing neutron facilities. Published by the American Physical Society 2024

74 ATOMIC AND MOLECULAR PHYSICS↗

MicroBooNE&#x27;s First Search for the MiniBooNE Anomalous Excess Under a Photon-Like Hypothesis with High-Sensitivity Search for Neutrino-Induced Neutral Current Delta Production and Radiative Decay

MicroBooNE is a liquid argon time projection chamber that collected neutrino data at Fermilab's Booster Neutrino Beam from 2015 to 2020. One of its primary goals is to investigate the “Low Energy Excess” of neutrino events observed by the MiniBooNE experiment, for which candidate photon-like interpretations include an underestimation of neutrino neutral current (NC) resonant $\Delta$ production with subsequent radiative decay or another anomalous source of single photon production in neutrino interactions. In particular, NC $\Delta$ radiative decay is poorly constrained background process to electron neutrino measurements and could be a sizable contribution to the “Low Energy Excess.” This thesis will present the analysis developed to search for NC $\Delta \rightarrow N\gamma$ events in MicroBooNE, consisting of a boosted decision tree based event selection with an NC neutral pion background constraint, using data from the first three years of operations corresponding to $6.9\times10^{20}$ POT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lowering the Energy Threshold of the CUORE Experiment: Benefits in the Surface Alpha Events Reconstruction

CUORE is a tonne-scale cryogenic experiment located at the Laboratori Nazionali del Gran Sasso that exploits bolometric technique to search for neutrinoless double beta decay of 130 Te. Thanks to its very low background and large mass, CUORE is also a powerful tool to study a broad class of phenomena, such as solar axions and WIMP scattering. The ability to conduct such sensitive searches crucially depends on the energy threshold, which has to be kept as low as possible. Here, we show how the trigger algorithm affects the sensitivity to low-energy phenomena and the interpretation of the energy spectrum. In particular, we focus on the impact that the trigger algorithm has on the identification of the coincidence events among different crystals and, consequently, on the reconstruction of the background.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of few-electron backgrounds in the LUX-ZEPLIN detector

The LUX-ZEPLIN (LZ) experiment aims to detect rare interactions between dark matter particles and xenon. Although the detector is designed to be the most sensitive to GeV/𝑐 2 –TeV/𝑐 2 weakly interacting massive particles (WIMPs), it is also capable of measuring low-energy ionization signals down to a single electron that may be produced by scatters of sub-GeV/𝑐 2 dark matter. The major challenge in exploiting this sensitivity is to understand and suppress the ionization background in the few-electron regime. We report a characterization of the delayed electron backgrounds following energy depositions in the LZ detector under different detector conditions. In addition, we quantify the probability for photons to be emitted in coincidence with electron emission from the high voltage grids. We then demonstrate that spontaneous grid electron emission can be identified and rejected with a high efficiency using a coincident photon tag, which provides a tool to improve the sensitivity of future dark matter searches.

Akerib, D. S. [SLAC National Accelerator Laborator↗

Aluminum relaxation as the source of excess low energy events in low threshold calorimeters

A previously unexplained background called the Low Energy Excess has negatively impacted the reach of a variety of low threshold calorimeters including light dark matter direct detection and coherent elastic neutrino-nucleus scattering experiments. The relaxation of stressed aluminum films as mediated by the motion of dislocations may account for these observations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The JLab Eta Factory (JEF) experiment

The new experiment, JLab Eta Factory (JEF), in the experimental Hall D at Jefferson Lab will extend the physics potential of the GlueX detector beyond the main spectroscopy program and perform precision measurements of various ?(?)decays with emphasis on rare neutral modes. The physics program of the experiment spans from precision tests of low-energy QCD to search of gauge bosons in the mass range below 1 GeV coupling the SM sector to the dark sector. Photoproduction of highly boosted ?(?)mesons using a tagged photon beam, good detection of recoil proton and multi-photon final states will allow to suppress background and collect high-statistics data sample of ?mesons. All these provide many advantages over other ?(?)experiments. The JEF experiment requires to upgrade the inner part of the forward lead glass calorimeter of the GlueX detector with high-granularity, high-resolution lead tungstate PbWO4 scintillating crystals. The calorimeter insert is currently under construction at Jeffeson Lab. The detector will be ready to take data in 2024. An overview of the JEF project will be presented.

Somov, Alexander↗