Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC GUIDE FIELD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Ionization profile monitors for the IOTA proton beam

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors — one vertical and one horizontal — are being developed for installation in the IOTA storage ring at Fermilab. They will be used for turn-by-turn (microseconds scale) measurements of the 70 MeV/c IOTA proton beam sizes. Furthermore, in this paper we present the IPMs design (largely following the FNAL Booster IPMs which employ no external guiding magnetic fields), their mechanical, vacuum, and electric subsystems and DAQ, and discuss anticipated effects on the beams circulating in IOTA.

Beam diagnostics↗

Laboratory Observations of Electron Heating and Non-Maxwellian Distributions at the Kinetic Scale during Electron-Only Magnetic Reconnection

Non-Maxwellian electron velocity distribution functions composed of a warm bulk population and a cold beam are directly measured during electron-only reconnection with a strong out-of-plane (guide) magnetic field in a laboratory plasma. Electron heating is localized to the separatrix, and the electron temperature increases continuously along the separatrix. The measured gain in enthalpy flux is 70% of the incoming Poynting flux. The electron beams are oppositely directed on either side of the X point, and their velocities are comparable to, and scale with, the electron Alfven speed. Particle-in-cell simulations are consistent with the measurements. Furthermore, the experimental results are consistent with, and go beyond, recent observations in the magnetosheath.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On Transient Time Reduction of a 2.4 GHz Relativistic Traveling Wave Oscillator with a Hollow Slow Wave System

The decrease in the transient time in a relativistic microwave traveling wave oscillator, in which the interaction is carried out between the relativistic electron beam and the fundamental harmonic of the forward-traveling electromagnetic wave slowed down to the speed of light in the hollow slow wave system system, has been numerically and experimentally demonstrated. It is shown that in this mode a high beam-to-wave coupling impedance up to ≈10 Ω is achieved, which ensures reduction of the transient time. In the experiment, a microwave peak power of 210 ± 30 MW at a frequency of 2.45 GHz in a guiding magnetic field of 0.16 T was obtained. The efficiency of the oscillator to convert the power of the electron beam into microwave power was 17 ± 3%. At the beam current pulse duration of about 50 ns the microwave pulse duration was about 20 ns and the transient time was about 22 ns.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Moderately Relativistic Subgigawatt Microwave Oscillator of Twistron Type Operating with 50% Efficiency

A regime of quasi-stationary microwave generation in moderately relativistic microwave oscillator of the twistron type with 50 ± 20% efficiency of electron beam power conversion into electromagnetic radiation has been obtained in experiment through optimization of the electron–wave interaction. For the selected electron beam parameters (diode voltage, 210 kV; beam current. 1.36 kA) the output microwave power at 10.63 GHz frequency was 140 ± 40 MW in a guiding magnetic field of about 1.9 T. The duration of microwave pulses was about 16 ns.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Diamagnetic-Loop-Based Beam Radius Monitor (BRM)

We describe a non-interceptive beam radius monitor that employs a diamagnetic loop. In order to increase the signal strength, the diamagnetic loop radius is considerably smaller than the outer wall radius, the device is placed inside a specially built solenoid magnet to allow independent adjustment of the guide magnetic field strength, and there are two counter-wound diamagnetic loops to double the signal strength and to eliminate common mode signals. This device is calibrated and the magnitude of the electron beam offset/tilt contribution to the measured radius estimated. This device is ready to be validated on an electron induction LINAC such a DARHT-I or DARHT-II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ionization Profile Monitors for the IOTA Proton Beam

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors - one vertical and one horizontal - are being developed for installation in the IOTA storage ring at Fermilab. They will be used for turn-by-turn (microseconds scale) measurements of the 70 MeV/c IOTA proton beam sizes. In this paper we present the IPMs design (largely following the FNAL Booster IPMs which employ no external guiding magnetic fields), their mechanical, vacuum, and electric subsystems and DAQ, and discuss anticipated effects on the beams circulating in IOTA.

43 PARTICLE ACCELERATORS↗

Anisotropic Particle Acceleration in Alfvénic Turbulence

Alfvénic turbulence is an effective mechanism for particle acceleration in strongly magnetized, relativistic plasma. In this study, we investigate a scenario where turbulent plasma is influenced by a strong guide magnetic field, resulting in highly anisotropic turbulent fluctuations. In such cases, the magnetic moments of particles are conserved, which means that acceleration can only occur along the direction of the magnetic field. Consistent with previous analytic studies, we find through particle-in-cell simulations of magnetically dominated pair plasma that the momenta of accelerated particles are closely aligned with the magnetic field lines. Notably, the alignment angle decreases as particle energy increases, potentially limited only by the inherent curvature and gradients of the turbulent magnetic fluctuations. This finding has significant implications for interpreting the synchrotron radiation emitted by highly accelerated particles.

79 ASTRONOMY AND ASTROPHYSICS↗

Proposed electron halo detector system as one of the beam overlap diagnostic tools for the new RHIC electron lens

An electron lens for head-on beam-beam compensation planned for RHIC requires precise overlap of the electron and proton beams which both can have down to 0.3 mm rms transverse radial widths along the 2m long interaction region. Here we describe a new diagnostic tool that is being considered to aid in the tuning and verification of this overlap. Some of ultra relativistic protons (100 or 250 GeV) colliding with low energy electrons (2 to 10 keV) will transfer sufficient transverse momentum to cause the electrons to spiral around the magnetic guiding field in a way that will make them detectable outside of the main solenoid. Time-of-flight of the halo electron signals will provide position-sensitive information along the overlap region. Scattering cross sections are calculated and counting rate estimates are presented as function of electron energy and detector position.

43 PARTICLE ACCELERATORS↗

Design of a proton-electron beam overlap monitor for the new RHIC electron lens, based on detecting energetic backscattered electrons

The optimal performance of the two electron lenses that are being implemented for high intensity polarized proton operation of RHIC requires excellent collinearity of the {approx}0.3 mm RMS wide electron beams with the proton bunch trajectories over the {approx}2m interaction lengths. The main beam overlap diagnostic tool will make use of electrons backscattered in close encounters with the relativistic protons. These electrons will spiral along the electron guiding magnetic field and will be detected in a plastic scintillator located close to the electron gun. A fraction of these electrons will have energies high enough to emerge from the vacuum chamber through a thin window thus simplifying the design and operation of the detector. The intensity of the detected electrons provides a measure of the overlap between the e- and the opposing proton beams. Joint electron arrival time and energy discrimination may be used additionally to gain some longitudinal position information with a single detector per lens.

43 PARTICLE ACCELERATORS↗

Ionization Profile Monitors for the IOTA Proton Beam

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors - one vertical and one horizontal - are being developed for installation in the IOTA storage ring at Fermilab. They will be used for turn-by-turn (microseconds scale) measurements of the 70 MeV/c IOTA proton beam sizes. In this paper we present the IPMs design (largely following the FNAL Booster IPMs which employ no external guiding magnetic fields), their mechanical, vacuum, and electric subsystems and DAQ, and discuss anticipated effects on the beams circulating in IOTA.

43 PARTICLE ACCELERATORS↗

Isodrastic magnetic fields for suppressing transitions in guiding-centre motion

In a magnetic field, transitions between classes of guiding-centre motion can lead to cross-field diffusion and escape. We say a magnetic field is isodrastic if guiding centres make no transitions between classes of motion. This is an important ideal for enhancing confinement. First, we present a weak formulation, based on the longitudinal adiabatic invariant, generalising omnigenity. To demonstrate that isodrasticity is strictly more general than omnigenity, we construct weakly isodrastic mirror fields that are not omnigenous. Then we present a strong formulation that is exact for guiding-centre motion. We develop a first-order treatment of the strong version via a Melnikov function and show that it recovers the weak version. The theory provides quantification of deviations from isodrasticity that can be used as objective functions in optimal design. The theory is illustrated with some simple examples.

97 MATHEMATICS AND COMPUTING↗

Degenerate variational integrators for magnetic field line flow and guiding center trajectories

Symplectic integrators offer many benefits for numerically approximating solutions to Hamiltonian differential equations, including bounded energy error and the preservation of invariant sets. Two important Hamiltonian systems encountered in plasma physics—the flow of magnetic field lines and the guiding center motion of magnetized charged particles—resist symplectic integration by conventional means because the dynamics are most naturally formulated in non-canonical coordinates. New algorithms were recently developed using the variational integration formalism; however, those integrators were found to admit parasitic mode instabilities due to their multistep character. This work eliminates the multistep character, and therefore the parasitic mode instabilities via an adaptation of the variational integration formalism that we deem “degenerate variational integration.” Both the magnetic field line and guiding center Lagrangians are degenerate in the sense that the resultant Euler-Lagrange equations are systems of first-order ordinary differential equations. We show that retaining the same degree of degeneracy when constructing discrete Lagrangians yields one-step variational integrators preserving a non-canonical symplectic structure. Lastly, numerical examples demonstrate the benefits of the new algorithms, including superior stability relative to the existing variational integrators for these systems and superior qualitative behavior relative to non-conservative algorithms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative Study of Guide Field Effects on Hall Reconnection in a Laboratory Plasma

The effect of guide field on magnetic reconnection is quantitatively studied by systematically varying an applied guide field in the Magnetic Reconnection Experiment (MRX). The quadrupole field, a signature of two-fluid reconnection at zero guide field, is significantly altered by a finite guide field. It is shown that the reconnection rate is significantly reduced with increasing guide field, and this dependence is explained by a combination of local and global physics: locally, the in-plane Hall currents are reduced, while globally guide field compression produces an increased pressure both within and downstream of the reconnection region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of magnetic field fluctuations and diamagnetic currents within a laser ablation plasma interacting with an axial magnetic field

Here, the guiding of laser ablation plasmas with axial magnetic fields has been used for many applications, since its effectiveness has been proven empirically. For more sophisticated and complicated manipulations of the plasma flow, the behavior of the magnetic field during the interaction and the induced diamagnetic current in the plasma plume needs to be clearly understood. To achieve the first milestone for establishing magnetic plasma manipulation, we measured the spatial and temporal fluctuations of the magnetic field caused by the diamagnetic current. We showed that the small fluctuations of the magnetic field can be detected by using a simple magnetic probe. We observed that the field penetrates to the core of the plasma plume. The diamagnetic current estimated from the magnetic field had temporal and spatial distributions which were confirmed to be correlated with the transformation of the plasma plume. Our results show that the measurement by the magnetic probe is an effective method to observe the temporal and spatial distributions of the magnetic field and diamagnetic current. The systematic measurement of the magnetic field variations is a valuable method to establish the magnetic field manipulation of the laser ablation plasma.

43 PARTICLE ACCELERATORS↗

Suppression of Collisionless Magnetic Reconnection in the High Ion β, Strong Guide Field Limit

Abstract In magnetic reconnection, the ion bulk outflow speed and ion heating have been shown to be set by the available reconnecting magnetic energy, i.e., the energy stored in the reconnecting magnetic field ( B r ). However, recent simulations, observations, and theoretical works have shown that the released magnetic energy is inhibited by upstream ion plasma beta β i —the relative ion thermal pressure normalized to magnetic pressure based on the reconnecting field—for antiparallel magnetic field configurations. Using kinetic theory and hybrid particle-in-cell simulations, we investigate the effects of β i on guide field reconnection. While previous works have suggested that guide field reconnection is uninfluenced by β i , we demonstrate that the reconnection process is modified and the outflow is reduced for sufficiently large β i > ( B r 2 + B g 2 ) / B r 2 . We develop a theoretical framework that shows that this reduction is consistent with an enhanced exhaust pressure gradient, which reduces the outflow speed as v out ∝ 1 / β i . These results apply to systems in which guide field reconnection is embedded in hot plasmas, such as reconnection at the boundary of eddies in fully developed turbulence like the solar wind or the magnetosheath as well as downstream of shocks such as the heliosheath or the mergers of galaxy clusters.

Giai, Carlos A.↗

Anomalous Resistivity and Electron Heating by Lower Hybrid Drift Waves during Magnetic Reconnection with a Guide Field

The lower hybrid drift wave (LHDW) has been a candidate for anomalous resistivity and electron heating inside the electron diffusion region of magnetic reconnection. In a laboratory reconnection layer with a finite guide field, quasielectrostatic LHDW (ES-LHDW) propagating along the direction nearly perpendicular to the local magnetic field is excited in the electron diffusion region. ES-LHDW generates large density fluctuations ($δn_{\text e}$, about 25% of the mean density) that are correlated with fluctuations in the out-of-plane electric field ($δE_Y$, about twice larger than the mean reconnection electric field). With a small phase difference (~ 30°) between two fluctuating quantities, the anomalous resistivity associated with the observed ES-LHDW is twice larger than the classical resistivity and accounts for 20% of the mean reconnection electric field. After we verify the linear relationship between $δn_{\text e}$ and $δE_Y$, anomalous electron heating by LHDW is estimated by a quasilinear analysis. The estimated electron heating is about 2.6 ± 0.3 MW / m 3 , which exceeds the classical Ohmic heating of about 2.0 ± 0.2 MW / m 3 . This LHDW-driven heating is consistent with the observed trend of higher electron temperatures when the wave amplitude is larger. Finally, presented results provide the first direct estimate of anomalous resistivity and electron heating power by LHDW, which demonstrates the importance of wave-particle interactions in magnetic reconnection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-J-03: Characterization of the Precision and Accuracy of a New, Preclinical, MRI-Guided Focused Ultrasound System for Image-Guided Interventions in Small-Bore, High-Field Magnets

Purpose: MRI-guided focused ultrasound (MRgFUS) has many potential and realized applications including controlled heating and localized drug delivery. The development of many of these applications requires extensive preclinical work, much of it in small animal models. The goal of this study is to characterize the spatial targeting accuracy and reproducibility of a preclinical high field MRgFUS system for thermal ablation and drug delivery applications. Methods: The RK300 (FUS Instruments, Toronto, Canada) is a motorized, 2-axis FUS positioning system suitable for small bore (72 mm), high-field MRI systems. The accuracy of the system was assessed in three ways. First, the precision of the system was assessed by sonicating regular grids of 5 mm squares on polystyrene plates and comparing the resulting focal dimples to the intended pattern, thereby assessing the reproducibility and precision of the motion control alone. Second, the targeting accuracy was assessed by imaging a polystyrene plate with randomly drilled holes and replicating the hole pattern by sonicating the observed hole locations on intact polystyrene plates and comparing the results. Third, the practicallyrealizable accuracy and precision were assessed by comparing the locations of transcranial, FUS-induced blood-brain-barrier disruption (BBBD) (observed through Gadolinium enhancement) to the intended targets in a retrospective analysis of animals sonicated for other experiments. Results: The evenly-spaced grids indicated that the precision was 0.11 +/− 0.05 mm. When image-guidance was included by targeting random locations, the accuracy was 0.5 +/− 0.2 mm. The effective accuracy in the four rodent brains assessed was 0.8 +/− 0.6 mm. In all cases, the error appeared normally distributed (p<0.05) in both orthogonal axes, though the left/right error was systematically greater than the superior/inferior error. Conclusions: The targeting accuracy of this device is sub-millimeter, suitable for many preclinical applications including focused drug delivery and thermal therapy. Funding support provided by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

Anisotropic Heating and Parallel Heat Flux in Electron-only Magnetic Reconnection with Intense Guide Fields

Electron-only reconnection (E-REC) is a process recently observed in the Earth’s magnetosheath, where magnetic reconnection occurs at electron kinetic scales, and ions do not couple to the reconnection process. Electron-only reconnection is likely to have a significant impact on the energy conversion and dissipation of turbulence cascades at kinetic scales in some settings. This paper investigates E-REC under different intensities of strong guide fields (the ratio between the guide field and the in-plane asymptotic field strength is 5, 10 and 20, respectively) via two-dimensional fully kinetic particle-in-cell simulations, focusing on electron heating. The simulations are initialized with a force-free current sheet equilibrium under various intensities of strong guide fields. Similarly to previous experimental studies, electron temperature anisotropy along separatrices is observed, which is found to be mainly caused by the variations of parallel temperature. Both regions of anisotropy and parallel temperature increase/decrease along separatrices become thinner with increasing guide fields. Besides, we find a transition from a quadrupolar to a hexapolar (six-polar) to an octopolar (eight-polar) structure in temperature anisotropy and parallel temperature as the guide field intensifies. Non-Maxwellian electron velocity distribution functions (EVDFs) at different locations in the three simulations are observed. Our results show that parallel electron velocity varies notably with different guide field intensities and finite parallel electron heat flux density is observed. The three simulations exhibit features of the Chew–Goldberger–Low theory, with the level of consistency increasing as the guide field strength increases. This explains the electron parallel temperature variations and the shape of the EVDFs observed along the separatrices. This work may provide insights into the understanding of electron heating and parallel heat flux density in E-REC observed in the turbulent magnetosheath.

79 ASTRONOMY AND ASTROPHYSICS↗