Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Magnetic plasma expulsion

Magnetic confinement of plasmas is widely studied for restricting a plasma's extent to a given region. Presented is one scheme for what is referred to as magnetic plasma expulsion, which would prevent the plasma from entering a given region. Magnetic plasma expulsion techniques may allow instrumentation access to the interiors of plasmas. Magnetic plasma expulsion techniques may also make alternative approaches for magnetic plasma confinement possible. Particle-in-cell simulation with the Warp code is used to study magnetic plasma expulsion. Some conditions for achieving magnetic plasma expulsion are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electroplating hard magnetic SmCo for magnetic microactuator applications

Patterned SmCo thin films were electroplated from an aqueous solute containing glycine by using dc and pulse dc current on the beaker level. Micromolds prepared by photolithography allow an accurate pattern transfer for patterned deposition of the material. A flux guide of a magnetic microactuator was chosen as a pattern, and Al{sub 2}O{sub 3} was used as the substrate. Au and Cr were investigated as seed layer materials. The content of Sm in the SmCo films is strongly dependent on the applied cathodic current density. A relative Sm content of up to 13.8 at. % could be determined by energy dispersive x-ray (EDX) spectroscopy. The SmCo thin films were annealed at 560 deg. C in a vacuum oven. Vibrating sample magnetometer (VSM) measurements were applied to characterize the magnetic properties. This film features hard magnetic properties with an intrinsic coercivity H{sub ci} of up to 44 kA/m. Electron probe microanalysis (EPMA) measurements showed that up to 40 at. % of O may be integrated in these films. The phases in the deposited films were determined by applying X-ray diffraction (XRD) measurements. These films consist of a mixture of SmCo alloy, Sm oxide, and Co.

36 MATERIALS SCIENCE↗

OBSERVATION OF HIGH-SPEED OUTFLOWS IN CORONAL LOOPS ASSOCIATED WITH PHOTOSPHERIC MAGNETIC FIELD EVOLUTION

Using SDO/AIA instruments, we provide an EUV observation of two adjacent loop strands (Loops 1 and 2) with one side of their footpoints rooted in the boundaries of active region (AR) NOAA 11158 and the other side in the quiet-Sun regions. The AR footpoints of Loop 1 were located in monopolar magnetic areas and those of Loop 2 in mixed polar areas (SDO/HMI magnetograms). There were no apparent outflows found in Loop 1 in 10 hr of observations, whereas in Loop 2, the outflows were detected throughout the whole observation with an average speed of 120-150 km s{sup -1}. We find clear evidence of magnetic reconnections occurring in the AR footpoints of Loop 2 (the opposite magnetic polarities came close and then a part of them disappeared) and magnetic flux dispersal in the quiet-Sun footpoints (a patch of positive polarities decayed with time). Furthermore, with Hinode/SOT observations, there were no significant Ca II H brightenings detected at the loop footpoints of Loop 2 at the chromospheric heights in response to those of the AIA 171 A and 304 A channels when four strong outflow events took place in the loops, which seem to differ from the conclusions of previous studies. In other studies, the rapid coronal outflows along the coronal loops were found to originate from the chromosphere through transient events (e.g., type II spicules).

79 ASTRONOMY AND ASTROPHYSICS↗

A comparison of four direct geometry time-of-flight spectrometers at the Spallation Neutron Source

The Spallation Neutron Source at Oak Ridge National Laboratory now hosts four direct geometry time-of-flight chopper spectrometers. These instruments cover a range of wave-vector and energy transfer space with varying degrees of neutron flux and resolution. The regions of reciprocal and energy space available to measure at these instruments are not exclusive and overlap significantly. We present a direct comparison of the capabilities of this instrumentation, conducted by data mining the instrument usage histories, and specific scanning regimes. In addition, one of the common science missions for these instruments is the study of magnetic excitations in condensed matter systems. We have measured the powder averaged spin wave spectra in one particular sample using each of these instruments, and use these data in our comparisons.

07 ISOTOPE AND RADIATION SOURCES↗

The influence of the magnetic field on running penumbral waves in the solar chromosphere

We use images of high spatial and temporal resolution, obtained using both ground- and space-based instrumentation, to investigate the role magnetic field inclination angles play in the propagation characteristics of running penumbral waves in the solar chromosphere. Analysis of a near-circular sunspot, close to the center of the solar disk, reveals a smooth rise in oscillatory period as a function of distance from the umbral barycenter. However, in one directional quadrant, corresponding to the north direction, a pronounced kink in the period-distance diagram is found. Utilizing a combination of the inversion of magnetic Stokes vectors and force-free field extrapolations, we attribute this behavior to the cut-off frequency imposed by the magnetic field geometry in this location. A rapid, localized inclination of the magnetic field lines in the north direction results in a faster increase in the dominant periodicity due to an accelerated reduction in the cut-off frequency. For the first time, we reveal how the spatial distribution of dominant wave periods, obtained with one of the highest resolution solar instruments currently available, directly reflects the magnetic geometry of the underlying sunspot, thus opening up a wealth of possibilities in future magnetohydrodynamic seismology studies. In addition, the intrinsic relationships we find between the underlying magnetic field geometries connecting the photosphere to the chromosphere, and the characteristics of running penumbral waves observed in the upper chromosphere, directly supports the interpretation that running penumbral wave phenomena are the chromospheric signature of upwardly propagating magneto-acoustic waves generated in the photosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

Fiber-optic diagnostic system for future accelerator magnets

The next generation high energy physics accelerators will require magnetic fields at ~20 T. HTS coils will be an essential component of future accelerator magnets and several efforts are currently dedicated on designing 20 T HTS- LTS hybrid magnets. Among the existing challenges, there is the lack of a robust quench detection system for hybrid magnet technology. Another big challenge is represented by the high number of training quenches required by Nb3Sn magnets to reach performance level. In this framework it is important to find a tool that allow local real-time monitoring of magnet strain and temperature. In this paper, we propose the use of fiber optics sensors for diagnostic and quench detection in future accelerator superconducting magnets. Discrete and distributed fiber optic sensors have demonstrated to be a promising tool. The goal is to instrument hundreds of accelerator superconducting magnets and to move beyond the proof-of-concept level. Significant developments are still needed. Here, we are going to present the most recent results and discuss the most urgent technical developments in order to make those sensors a robust and reliable diagnostic tool for accelerator superconducting magnets over the next 10 year. We foresee that discrete fiber sensors will be a stable diagnostic probe for superconducting magnets over the next 3 to 5 years. More R&D work will be necessary for distributed fibers. The most urgent needs are the increase of sample rate and sensitivity. Close collaboration with vendors will be necessary to improve mechanical properties and fabrication processes in order to produce hundreds of meters of fiber and instrument a large number of accelerator superconducting magnets. Those R&D efforts will last up to 10 years with a founding level that spans between 5-10 M$.

43 PARTICLE ACCELERATORS↗

Status and future plans for C 3 R&D

C 3 is an opportunity to realize an e + e - collider for the study of the Higgs boson at √s = 250 GeV, with a well defined upgrade path to 550 GeV while staying on the same short facility footprint. C 3 is based on a fundamentally new approach to normal conducting linear accelerators that achieves both high gradient and high efficiency at relatively low cost. Given the advanced state of linear collider designs, the key system that requires technical maturation for C 3 is the main linac. This paper presents the staged approach towards a facility to demonstrate C 3 technology with both Direct (source and main linac) and Parallel (beam delivery, damping ring, ancillary component) R&D. The primary goal of the C 3 Demonstration R&D Plan is to reduce technical and cost risk by building and operating the key components of C 3 at an adequate scale. This R&D plan starts with the engineering design, and demonstration of one cryomodule and will culminate in the construction of a 3 cryomodule linac with pre-production prototypes. This R&D program would also demonstrate the linac rf fundamentals including achievable gradient and gradient stability over a full electron bunch train and breakdown rates. It will also investigate beam dynamics including energy spread, wakefields, and emittance growth. This work will be critical to confirm the suitability of the C 3 beam parameters for the physics reach and detector performance in preparation for a Conceptual Design Report (CDR), as well as for follow-on technology development and industrialization. The C 3 Demonstration R&D Plan will open up significant new scientific and technical opportunities based on development of high-gradient and high-efficiency accelerator technology. It will push this technology to operate both at the GeV scale and mature the technology to be reliable and provide high-brightness electron beams. The timeline for progressing with C 3 technology development will be governed by practical limitations on both the technical progress and resource availability. It consists of four stages: Stage 0) Ongoing fundamental R&D on structure prototypes, damping and vibrations. Stage 1) Advancing the engineering maturity of the design and developing start-to-end simulations including space-charge and wakefield effects. This stage will include testing of strucutres operating at cryogenic temperatures. Beam tests would be performed with high beam current to test full beam loading. Stage 2) Production and testing of the first cryomodule at cryogenic temperatures. This would provide sufficient experimental data to compile a CDR and it is anticipated for Stage 2 to last 3 years and to culminate with the transport of photo-electrons through the first cryomodule. Stage 3) Updates to the engineering design of the cryomodules, production of the second and third cryomodule and their installation. Lower charge and lower emittance beams will be used to investigate emittance growth. The successful full demonstration of the 3 cryomodules to deliver up to a 3 GeV beam and achieve the C 3 five gradient will allow a comprehensive and robust evaluation of the technical design of C 3 as well as mitigate technical, schedule, and cost risks required to proceed with a Technical Design Report (TDR).

radiation hardened magnets↗

Characterization of High Current RRP(R) Wires as a Function of Magnetic Field, Temperature and Strain

A new instrument for the characterization of superconducting materials as a function of Magnetic Field, Temperature and Strain, was designed, constructed and tested at Lawrence Berkeley National Laboratory (LBNL). A U-shaped bending spring was selected, since that design has proven to enable accurate characterizations of a multitude of superconducting materials for more than a decade. The new device is validated though measurements on very high current Rod Restack Processed (RRP) Internal-Tin (IT) wires, for which we will present initial results, including parameterizations of the superconducting phase boundaries and comparisons with other wire types. Accurate parametrization of modern high magnetic field conductors is important for the analysis of the performance of magnet systems.

43 PARTICLE ACCELERATORS↗

Emergent phenomena and proximity effects in two-dimensional magnets and heterostructures

Ultrathin van der Waals materials and their heterostructures offer a simple, yet powerful platform for discovering emergent phenomena and implementing device structures in the two-dimensional limit. The past few years has pushed this frontier to include magnetism. These advances have brought forth a new assortment of layered materials that intrinsically possess a wide variety of magnetic properties and are instrumental in integrating exchange and spin–orbit interactions into van der Waals heterostructures. This Review Article summarizes recent progress in exploring the intrinsic magnetism of atomically thin van der Waals materials, manipulation of their magnetism by tuning the interlayer coupling, and device structures for spin- and valleytronic applications.

36 MATERIALS SCIENCE↗

Designing a Magnetic Measurement Data Acquisition and Control System With Reuse in Mind: A Rotating Coil System Example

Accelerator magnet test facilities frequently need to measure different magnets on differently equipped test stands and with different instrumentation. Designing a modular and highly reusable system that combines flexibility built-in at the architectural level as well as on the component level addresses this need. Specification of the backbone of the system, with the interfaces and dataflow for software components and core hardware modules, serves as a basis for building such a system. The design process and implementation of an extensible magnetic measurement data acquisition and control system are described, including techniques for maximizing the reuse of software. The discussion is supported by showing the application of this methodology to constructing two dissimilar systems for rotating coil measurements, both based on the same architecture and sharing core hardware modules and many software components. The first system is for production testing 10 m long cryo-assemblies containing two MQXFA quadrupole magnets for the high-luminosity upgrade of the Large Hadron Collider and the second for testing IQC conventional quadrupole magnets in support of the accelerator system at Fermilab.

43 PARTICLE ACCELERATORS↗

An optimized microfabricated platform for the optical generation and detection of hyperpolarized 129 Xe

Low thermal-equilibrium nuclear spin polarizations and the need for sophisticated instrumentation render conventional nuclear magnetic resonance (NMR) spectroscopy and imaging (MRI) incompatible with small-scale microfluidic devices. Hyperpolarized 129 Xe gas has found use in the study of many materials but has required very large and expensive instrumentation. Recently a microfabricated device with modest instrumentation demonstrated all-optical hyperpolarization and detection of 129 Xe gas. This device was limited by 129 Xe polarizations less than 1%, 129 Xe NMR signals smaller than 20 nT, and transport of hyperpolarized 129 Xe over millimeter lengths. Higher polarizations, versatile detection schemes, and flow of 129 Xe over larger distances are desirable for wider applications. Here we demonstrate an ultra-sensitive microfabricated platform that achieves 129 Xe polarizations reaching 7%, NMR signals exceeding 1 μT, lifetimes up to 6 s, and simultaneous two-mode detection, consisting of a high-sensitivity in situ channel with signal-to-noise of 10 5 and a lower-sensitivity ex situ detection channel which may be useful in a wider variety of conditions. 129 Xe is hyperpolarized and detected in locations more than 1 cm apart. Our versatile device is an optimal platform for microfluidic magnetic resonance in particular, but equally attractive for wider nuclear spin applications benefitting from ultra-sensitive detection, long coherences, and simple instrumentation.

36 MATERIALS SCIENCE↗

Overview of the superconducting undulator development program at ANKA

Superconducting undulators (SCUs) have the potential to reach higher brilliance and flux with respect to the state of the art permanent magnet insertion devices. ANKA is collaborating with the industrial partner Babcock Noell GmbH (BNG) to realize NbTi conduction cooled planar devices for low emittance light sources, and is developing the instrumentation to characterize the magnetic field properties and to measure the beam heat load to a cold bore needed for the cryogenic design of SCUs. We present here: the most recent results obtained within the ANKA-BNG collaboration, the progress achieved in the development of the instrumentation, and the in house studies on the application of high temperature superconducting (HTS) tape to the SCU technology.

43 PARTICLE ACCELERATORS↗

The effect of magnetic susceptibility and magnetic field strength on porosity estimates determined from low-field nuclear magnetic resonance

The presence of materials with high magnetic susceptibility are known to have an impact on 1H nuclear magnetic resonance (NMR) measurements and in laboratory data this often results in poor estimates of porosity from NMR data. To quantify and understand the cause of the poor NMR porosity estimations, in this laboratory study, we examine the effect of magnetic susceptibility, NMR measurement parameters, and NMR instrument design on NMR measurements. Data were collected with two instruments, each with a different Larmor frequency (2 MHz and 485 kHz), on water-saturated unconsolidated sediments with magnetic susceptibility values ranging from 3.6 × 10 -6 to 7020 × 10 -6 SI. The results show that for materials with low magnetic susceptibility (<378 × 10 -6 SI), the gravimetric porosity is accurately predicted from the NMR measurements. For the samples with high magnetic susceptibility (>987 × 10 -6 SI) the gravimetric porosity is poorly predicted from the 2 MHz NMR measurements made at all echo times (from 0.2 to 3.0 ms). In contrast, the gravimetric porosity is more accurately predicted at an echo time of 0.2 ms for measurements made using the 485 kHz instrument, although at larger echo times (>1.0 ms), the porosity estimate becomes poor. The 485 kHz NMR instrument has non-zero internal magnetic field gradients, similar to those found in borehole instruments, in contrast to the 2 MHz NMR instrument, which has a homogeneous applied magnetic field. Finally, we conclude that differences is the magnetic field strength and higher magnetic field inhomogeneities in the 485 kHz NMR instrument contribute to a reduction of the impact of inhomogeneities in the magnetic field caused by materials with high magnetic susceptibility, allowing for improved porosity estimation. These results indicate that NMR measurements collected at short echo times in low, inhomogeneous static fields, e.g., borehole instruments, may provide accurate estimates of porosity in water saturated sediments, even in the presence of magnetic minerals.

58 GEOSCIENCES↗

Multi-dimensional incoherent Thomson scattering system in PHAse Space MApping (PHASMA) facility

A multi-dimensional incoherent Thomson scattering diagnostic system capable of measuring electron temperature anisotropies at the level of the electron velocity distribution function (EVDF) is implemented on the PHAse Space MApping facility to investigate electron energization mechanisms during magnetic reconnection. This system incorporates two injection paths (perpendicular and parallel to the axial magnetic field) and two collection paths, providing four independent EVDF measurements along four velocity space directions. For strongly magnetized electrons, a 3D EVDF comprised of two characteristic electron temperatures perpendicular and parallel to the local magnetic field line is reconstructed from the four measured EVDFs. As a result, validation of isotropic electrons in a single magnetic flux rope and a steady-state helicon plasma is presented.

47 OTHER INSTRUMENTATION↗

Overview of Nonintercepting Beam-Size Monitoring with Optical Diffraction Radiation

The initial demonstrations over the last several years of the use of optical diffraction radiation (ODR) as nonintercepting electron-beam-parameter monitors are reviewed. Developments in both far-field imaging and near-field imaging are addressed for ODR generated by a metal plane with a slit aperture, a single metal plane, and two-plane interferences. Polarization effects and sensitivities to beam size, divergence, and position will be discussed as well as a proposed path towards monitoring 10-micron beam sizes at 25 GeV.

43 PARTICLE ACCELERATORS↗

A range-based method to calibrate a magnetic spectrometer measuring the energy spectrum of the backward electron beam of a plasma focus

The electron beam emitted from the back of plasma focus devices is being studied as a radiation source for intraoperative radiation therapy applications. A plasma focus device is being developed for this purpose, and there is a need for characterizing its electron beam, particularly, insofar as the energy spectrum is concerned. The instrument used is a magnetic spectrometer. To calibrate this spectrometer, a procedure relying on the energy-range relation in Mylar has been devised and applied. By measuring the transmission through increasing thicknesses of the material, electron energies could be assessed and compared to the spectrometer readings. Thus, the original calibration of the instrument has been extended to higher energies and also to better accuracy. Methods and results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗