Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC SURFACES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

THE SPACE WEATHER OF PROXIMA CENTAURI b

A planet orbiting in the “habitable zone” of our closest neighboring star, Proxima Centauri, has recently been discovered, and the next natural question is whether or not Proxima b is “habitable.” Stellar winds are likely a source of atmospheric erosion that could be particularly severe in the case of M dwarf habitable zone planets that reside close to their parent star. Here, we study the stellar wind conditions that Proxima b experiences over its orbit. We construct 3D MHD models of the wind and magnetic field around Proxima Centauri using a surface magnetic field map for a star of the same spectral type and scaled to match the observed ∼600 G surface magnetic field strength of Proxima. We examine the wind conditions and dynamic pressure over different plausible orbits that sample the constrained parameters of the orbit of Proxima b. For all the parameter space explored, the planet is subject to stellar wind pressures of more than 2000 times those experienced by Earth from the solar wind. During an orbit, Proxima b is also subject to pressure changes of 1–3 orders of magnitude on timescales of a day. Its magnetopause standoff distance consequently undergoes sudden and periodic changes by a factor of 2–5. Proxima b will traverse the interplanetary current sheet twice each orbit, and likely crosses into regions of subsonic wind quite frequently. These effects should be taken into account in any physically realistic assessment or prediction of its atmospheric reservoir, characteristics, and loss.

79 ASTRONOMY AND ASTROPHYSICS↗

Sequestration, fluorometric detection, and mass spectroscopy analysis of lanthanide ions using surface modified magnetic microspheres for microfluidic manipulation.

Several methods for rapid sequestration, fluorometric detection, and the subsequent mass spectroscopic analysis of lanthanide ions using surface modified polystyrene magnetic microspheres are demonstrated. Mixed-ligand antenna complexes of Eu{sup 3+} in which one of the ligands is attached to the surface of the microspheres have been used as a means for the sequestration, immobilization, and detection of these ions. Using the ion-exchange properties of these microspheres, this scheme has been extended to the detection of nonluminescent ions. The principles of these assays form the basis for operation of a portable microfluidic device for general analytical and nuclear forensics applications and indicate the manner in which the established methods of analytical chemistry, such as liquid-liquid extraction and ion-exchange chromatography, can be adapted for such miniature devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tuning the Magnetic Properties of CrI 3 Using Ni Thin Film Deposition for Applications in Spintronic Devices

Chromium triiodide (CrI 3 ), a van der Waals magnet, has recently been shown to host Ising ferromagnetism down to the monolayer limit. It is a potentially important material in 2D magnet-based applications, such as magnetic sensors and spintronic devices. Prior studies have revealed the coexistence of two different types of interlayer magnetic coupling, the antiferromagnetic (AFM) coupling near the surface and ferromagnetic (FM) coupling in the deep bulk layers, in pristine CrI 3 crystals below the Curie temperature. In this study, we used Ni thin film deposition to tune the surface magnetic states in bulk CrI 3 . A nanometer thickness (4 nm thick) of Ni was deposited on the surface of CrI 3 using electron-beam evaporation to form a Ni/CrI 3 heterostructure. The deposited Ni thin layer forms nanoclusters that completely cover the CrI 3 surface. Magnetic states of CrI 3 before and after Ni deposition are probed by ultralow-frequency magneto-Raman spectroscopy. Instead of seeing three spin wave branches in Raman scattering below 2 T, as in pristine bulk CrI 3 , in Ni/CrI 3 , we observe only a single spin wave branch, which is softened compared to that in pristine CrI 3 and displays a Zeeman shift under an out-of-plane magnetic field up to 7 T. This observation reveals that the AFM layers on pristine CrI 3 crystal surfaces transit into FM layers, so the entire CrI 3 crystal is in the FM state after Ni deposition. First-principles calculations show that Ni atoms tend to diffuse into the CrI 3 lattice, and the FM interlayer coupling has a much lower energy than AFM coupling in the presence of Ni atoms. As a result, our studies show that the magnetic state of CrI 3 can be modified through deposition of a thin metal layer on the surface, offering a route for controlling the spin degree of freedom in van der Waals magnets.

36 MATERIALS SCIENCE↗

Validation of single-fluid and two-fluid magnetohydrodynamic models of the helicity injected torus spheromak experiment with the NIMROD code

We present a comparison study of 3-D pressureless resistive MHD (rMHD) and 3-D presureless two-fluid MHD models of the Helicity Injected Torus with Steady Inductive helicity injection (HIT-SI). HIT-SI is a current drive experiment that uses two geometrically asymmetric helicity injectors to generate and sustain toroidal plasmas. The comparable size of the collisionless ion skin depth d{sub i} to the resistive skin depth predicates the importance of the Hall term for HIT-SI. The simulations are run with NIMROD, an initial-value, 3-D extended MHD code. The modeled plasma density and temperature are assumed uniform and constant. The helicity injectors are modeled as oscillating normal magnetic and parallel electric field boundary conditions. The simulations use parameters that closely match those of the experiment. The simulation output is compared to the formation time, plasma current, and internal and surface magnetic fields. Results of the study indicate 2fl-MHD shows quantitative agreement with the experiment while rMHD only captures the qualitative features. The validity of each model is assessed based on how accurately it reproduces the global quantities as well as the temporal and spatial dependence of the measured magnetic fields. 2fl-MHD produces the current amplification (I{sub tor}/I{sub inj}) and formation time τ{sub f} demonstrated by HIT-SI with similar internal magnetic fields. rMHD underestimates (I{sub tor}/I{sub inj}) and exhibits much a longer τ{sub f}. Biorthogonal decomposition (BD), a powerful mathematical tool for reducing large data sets, is employed to quantify how well the simulations reproduce the measured surface magnetic fields without resorting to a probe-by-probe comparison. BD shows that 2fl-MHD captures the dominant surface magnetic structures and the temporal behavior of these features better than rMHD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aviation Mission Profile Performance Evaluation in a High Specific Power Surface Permanent Magnet Machine with Additively Manufactured Coils and Integrated Heat Pipes

The purpose of this paper is to accurately evaluate the performance and overall efficiency of an electrical machine driving a propeller (as a part of a hybrid or electric propulsion system) during the flight mission profile using electromagnetic-thermal simulations. The study focuses on a 250 kW, 5000 rpm, 1.25 kHz, 36/30 slot/pole surface permanent magnet (SPM) machine with additively manufactured (AM) hollow conductors and integrated heat pipes (HP). The machine drive parameters (frequency, and current) are tuned to maximize the efficiency for a given flight cycle, while providing the highest specific power (SP) during takeoff. Afterward using Multiphysics simulations, the transient thermal behavior of the machine is studied and temperature profile for different parts of the machine is extracted. Finally, steady-state temperatures during cruising are estimated and overall efficiency is re-evaluated.

additive manufacturing↗

Isodynamic axisymmetric equilibrium near the magnetic axis

Plasma equilibrium near the magnetic axis of an axisymmetric toroidal magnetic confinement system is described in orthogonal flux coordinates. For the case of a constant current density in the vicinity of the axis and magnetic surfaces with nearly circular cross sections, expressions for the poloidal and toroidal magnetic field components are obtained in these coordinates by using expansion in the reciprocal of the aspect ratio. These expressions allow one to easily derive relationships between quantities in an isodynamic equilibrium, in which the absolute value of the magnetic field is constant along the magnetic surface (Palumbo’s configuration)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of Anisotropic Thermal Conductivity in Magnetohydrodynamics Simulations of a Reversed-Field Pinch

A compressible magnetohydrodynamics simulation of the reversed-field pinch is performed including anisotropic thermal conductivity. When the thermal conductivity is much larger in the direction parallel to the magnetic field than in the perpendicular direction, magnetic field lines become isothermal. As a consequence, as long as magnetic surfaces exist, a temperature distribution is observed displaying a hotter confined region, while an almost uniform temperature is produced when the magnetic field lines become chaotic. To include this effect in the numerical simulation, we use a multiple-time-scale analysis, which allows us to reproduce the effect of a large parallel thermal conductivity. The resulting temperature distribution is related to the existence of closed magnetic surfaces, as observed in experiments. The magnetic field is also affected by the presence of an anisotropic thermal conductivity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Prototype Superconducting Radio-Frequency Cavity for Conduction-Cooled Accelerators

Recent progress in the development of high-quality Nb?Sn film coatings along with the availability of cryocoolers with high cooling capacity at 4 K makes it feasible to operate SRF cavities cooled by thermal conduction at relevant accelerating gradients for use in accelerators. We have developed a prototype single-cell cavity to prove the feasibility of operation up to the accelerating gradient required for 1 MeV energy gain, cooled by conduction with cryocoolers. The cavity has a ~3 ¿m thick Nb?Sn film on the inner surface, deposited on a ~4 mm thick bulk Nb substrate and a bulk ~7 mm thick Cu outer shell with three Cu attachment tabs. The cavity was tested up to a peak surface magnetic field of 53 mT in liquid He at 4.3 K. A horizontal test cryostat was designed and built to test the cavity cooled with three cryocoolers. The rf tests of the conduction-cooled cavity achieved a peak surface magnetic field of 50 mT and stable operation was possible with up to 18.5 W of rf heat load. The peak frequency shift due to microphonics was 23 Hz. These results represent the highest peak surface magnetic field achieved in a conduction-cooled SRF cavity to date

Ciovati, Gianluigi↗

Development of an accelerator-based diagnostic for plasma-facing surfaces in magnetic confinement devices

The focus of this work was the development of the Accelerator-based In-situ Material Surveillance (AIMS) diagnostic. The understanding of plasma-material interaction processes in fusion devices has been greatly hampered by the lack of ability to measure the surface ~micron layers of solid surfaces that are in contact with and greatly modified by the boundary fusion plasma. AIMS was the first diagnostic developed and deployed that allowed non-destructive surface measurements with adequate spatial and time resolution. The deployment was primarily carried out on the Alcator C-Mod tokamak. AIMS diagnostic goal is to remotely generate isotopic concentration maps on a plasma shot-to-shot timescale that cover a large fraction of the plasma-facing surface inside of a magnetic fusion device without the need for vacuum breaks or physical access to the material surfaces. The diagnostic used a compact (~ 1 m), high-current (~ 1 milliamp) radio-frequency quadrupole accelerator to inject 0.9 MeV deuterons into the Alcator C-Mod tokamak. The tokamak magnetic fields were controlled – in between plasma shots – to steer the deuterons to material surfaces where the deuterons cause high-Q nuclear reactions with low-Z isotopes up to 5 microns into the material. The induced neutrons and gamma rays are measured with scintillation detectors; energy spectra analysis provides quantitative reconstruction of surface compositions. Experimental validation showed that low-Z isotopes such as deuterium and boron can be quantified on the material surfaces, and that magnetic steering provides access to different measurement locations. AIMS measurements of D retention on inner wall PFCs were acquired during diverted and limited plasma operations and during wall conditioning experiments om Alcator C-Mod. Intershot measurements demonstrate the local erosion and co-deposition of boron films on PFC surfaces with a constant D-B ratio. This is consistent with previous results suggesting that D co-=deposition with boron is insufficient to account for the net retention observed in Alcator C-Mod. Changes in deuterium concentration during boronization, electron cyclotron and glow cleanings were also measured. These initial results were limited to studying low-Z surface properties, because the Coulomb barrier precludes nuclear reactions between high-Z elements and the ~1 MeV AIMS deuteron beam. In order to measure the high-Z erosion of interest in Alcator C-Mod and future fusion devices, a new technique using deuteron-induced gamma emission and a low-Z depth marker was developed using implanted depth markers as a method of measuring bulk erosion and redeposition. This method is dubbed DEA: Depth marker Erosion with AIMS. DEA simulations and experiments were used to validate this technique, both in the laboratory and via experiments in the EAST tokamak. Based on these results, the DEA technique, using ion beam implanted depth markers as a reference to the surface in order to monitor surfaces for erosion and redeposition, is a viable option as a diagnostic, both in and ex situ. These markers show stability to temperature, the tokamak environment, and multiple probing beams. The ex-situ (eDEA) method, which uses resonances in the cross sections of gamma producing reactions to track the surface, was used to successfully measure erosion in samples that were exposed in the EAST tokamak. The in-situ (iDEA) method, which uses the gamma yield ratio to monitor changes to the surface, was used to differentiate between markers implanted to different depths. Both techniques were successfully simulated, and both presented unique challenges experimentally and in data analysis. In particular, the eDEA probing beam was found to have energy variations leading to initial experimental uncertainty, and the iDEA gamma spectra had conflicting gamma peaks which make data analysis difficult. However, the end result is a promising framework for a diagnostic technique that supplements the abilities of AIMS and expands the possibilities of surface diagnostics in fusion devices. While the results of this work are overwhelmingly encouraging for further development of AIMS in general, and the DEA technique specifically, several areas require significant development before this diagnostic is as robust and widely applicable as a surface diagnostic ought to be. Recommended future work includes the development of a cross section/yield measurement database, erosion tests with secondary verification of results using a fiducial mark from a focused ion beam, and acquiring a new accelerator with a more reliable high energy proton and deuterium beam The project resulted in 14 publications, including the PhD theses of three MIT graduate students, cited in the included bibliography.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma equilibrium in 3D magnetic confinement systems and soliton theory

Single-valued conformal flux (magnetic) coordinates can always be introduced on arbitrary toroidal magnetic surfaces. It is shown how such coordinates can be obtained by transforming Boozer magnetic coordinates on the surfaces. The metrics is substantially simplified and the coordinate grid is orthogonalized at the expense of a more complicated representation of the magnetic field in conformal flux coordinates. This in turn makes it possible to introduce complex angular flux coordinates on any toroidal magnetic surface and to develop efficient methods for a complex analysis of the geometry of equilibrium magnetic surfaces. The complex analysis reveals how the plasma equilibrium problem is related to soliton theory. Magnetic surfaces of constant mean curvature are considered to exemplify this relationship.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Configurable antiferromagnetic domains and lateral exchange bias in atomically thin CrPS 4

Interfacial exchange coupling between antiferromagnets (AFMs) and ferromagnets (FMs) crucially makes it possible to shift the FM hysteresis, known as exchange bias, and to switch AFM states. Two-dimensional magnets unlock opportunities to combine AFM and FM materials; however, the buried AFM–FM interfaces obtained by stacking remains challenging to understand. Here, in this work, we demonstrate interfacial control via intralayer exchange coupling in the layered AFM CrPS 4 , where connected even and odd layers realize pristine lateral interfaces between AFM-like and FM-like regions. We distinguish antiphase even-layer states by scanning nitrogen-vacancy centre magnetometry due to a weak surface magnetization. This surface magnetization enables control over the even-layer state, with different regions switching at distinct fields due to their own lateral couplings. We toggle three AFM domains adjacent to a FM-like region and demonstrate a tunable multilevel exchange bias. Our nanoscale visualization unveils the microscopic origins of exchange bias and advances single two-dimensional crystals for hybrid AFM–FM technologies.

magnetic devices↗

Monte Carlo characterization of skin doses in 6 MV transverse field MRI-linac systems: Effect of field size, surface orientation, magnetic field strength, and exit bolus

Purpose: The main focus of this work is to continue investigations into the Monte Carlo predicted skin doses seen in MRI-guided radiotherapy. In particular, the authors aim to characterize the 70 {mu}m skin doses over a larger range of magnetic field strength and x-ray field size than in the current literature. The effect of surface orientation on both the entry and exit sides is also studied. Finally, the use of exit bolus is also investigated for minimizing the negative effects of the electron return effect (ERE) on the exit skin dose. Methods: High resolution GEANT4 Monte Carlo simulations of a water phantom exposed to a 6 MV x-ray beam (Varian 2100C) have been performed. Transverse magnetic fields of strengths between 0 and 3 T have been applied to a 30x30x20 cm{sup 3} phantom. This phantom is also altered to have variable entry and exit surfaces with respect to the beam central axis and they range from -75 deg. to +75 deg. The exit bolus simulated is a 1 cm thick (water equivalent) slab located on the beam exit side. Results: On the entry side, significant skin doses at the beam central axis are reported for large positive surface angles and strong magnetic fields. However, over the entry surface angle range of -30 deg. to -60 deg., the entry skin dose is comparable to or less than the zero magnetic field skin dose, regardless of magnetic field strength and field size. On the exit side, moderate to high central axis skin dose increases are expected except at large positive surface angles. For exit bolus of 1 cm thickness, the central axis exit skin dose becomes an almost consistent value regardless of magnetic field strength or exit surface angle. This is due to the almost complete absorption of the ERE electrons by the bolus. Conclusions: There is an ideal entry angle range of -30 deg. to -60 deg. where entry skin dose is comparable to or less than the zero magnetic field skin dose. Other than this, the entry skin dose increases are significant, especially at higher magnetic fields. On the exit side there is mostly moderate to high skin dose increases for 0.2-3 T with the only exception being large positive angles. Exit bolus of 1 cm thickness will have a significant impact on lowering such exit skin dose increases that occur as a result of the ERE.

60 APPLIED LIFE SCIENCES↗

Electronic and magnetic properties of manganite thin films with different compositions and its correlation with transport properties: An X-ray resonant magnetic scattering study

Here, we present x-ray resonant magnetic dichroism and x-ray resonant magnetic scattering measurements of the temperature dependence of magnetism in Pr-doped La-Ca-Mn-O films grown on (110) NdGaO{sub 3} substrates. We observed thermal hysteresis of the ferromagnetism in one film that also showed large thermal hysteresis of ∼18 K in transport measurements. While in a second film of a different nominal chemistry, which showed very small thermal hysteresis ∼3 K in transport measurements, no thermal hysteresis of the ferromagnetism was observed. These macroscopic properties are correlated with evolution of surface magnetization across metal insulator transition for these films as observed by soft x-ray resonant magnetic scattering measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A simplified, numerically verified model for the global plasma reaction on a local cooling

An analytical model for heat losses along a magnetic surface to its small region cooled down abruptly to a very low temperature is deduced by applying a principle of minimum entropy production and verified by comparing with the results obtained by solving non-stationary two-dimensional heat conduction equation numerically. The model is elaborated further by taking into account heat flux limit and the plasma density modification due to the particle convection along the magnetic surface, triggered by the plasma pressure imbalance arising by the local cooling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface and magnetic characteristics of Ni-Mn-Ga/Si (100) thin film

Polycrystalline Ni-Mn-Ga thin films have been deposited on Si (100) substrate with different film thickness. The influence of film thickness on the phase structure and magnetic domain of the films has been examined by scanning electron microscope, atomic force microscopy and magnetic force microscopy. Analysis of structural parameters indicates that the film at lower thickness exhibits the coexistence of both austenite and martensite phase, whereas at higher thickness L1{sub 2} cubic non magnetic phase is noticed. The grains size and the surface roughness increase along with the film thickness and attain the maximum of 45 nm and 34.96 nm, respectively. At lower film thickness, the magnetic stripe domain is found like maze pattern with dark and bright images, while at higher thickness the absence of stripe domains is observed. The magnetic results reveal that the films strongly depend on their phase structure and microstructure which influence by the film thickness.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic microstructure and magnetic properties of uniaxial itinerant ferromagnet Fe 3 GeTe 2

Here, magnetic force microscopy was used to observe the magnetic microstructure of Fe 3 GeTe 2 at 4 K on the (001) surface. The surface magnetic structure consists of a two-phase domain branching pattern that is characteristic for highly uniaxial magnets in the plane perpendicular to the magnetic easy axis. The average surface magnetic domain width D s = 1.3 μm determined from this pattern, in combination with intrinsic properties calculated from bulk magnetization data (the saturation magnetization M s = 376 emu/cm 3 and the uniaxial magnetocrystalline anisotropy constant K u = 1.46 × 10 7 erg/cm 3 ), was used to determine the following micromagnetic parameters for Fe 3 GeTe 2 from phenomenological models: the domain wall energy γ w = 4.7 erg/cm 2 , the domain wall thickness δ w = 2.5 nm, the exchange stiffness constant A ex = 0.95 × 10 –7 erg/cm, the exchange length l ex = 2.3 nm, and the critical single domain particle diameter d c = 470 nm.

36 MATERIALS SCIENCE↗

Numerical studies of transport in the Columbia Non-neutral Torus

The confinement of pure electron plasmas in the Columbia Non-neutral Torus (CNT) stellarator is limited by the presence of unconfined orbits. The existence of a very large electric field across magnetic surfaces should preclude such unconfined orbits. However variations in the electric potential on magnetic surfaces, inherent to the CNT equilibrium, add to the complexity of the trajectories and lead to bad orbits. We have written a code using magnetic coordinates to integrate the electron drift trajectories in the electric and magnetic fields expected in CNT equilibria. Results of such calculations are presented showing that there exists unconfined orbits in CNT if the potential is not constant on surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the formation of m = 1, n = 1 density snakes

The m/n = 1/1 helical ion density 'snake' located near the q = 1 magnetic surface in a toroidal, magnetically confined plasma arises naturally in resistive MHD, when the plasma density evolves separately from pressure. Nonlinear numerical simulations show that a helical density perturbation applied around q = 1 can form a quasi-steady state over q Greater-Than-Or-Equivalent-To 1 with T(tilde sign) of opposite average sign to n. Two principal outcomes depend on the magnitude of n/n and the underlying stability of the 1/1 internal kink mode. For a small q<1 central region, a moderate helical density drives a new, slowly growing type of nonlinear 1/1 internal kink inside q<1, with small n and {nabla}p(tilde sign) Asymptotically-Equal-To {nabla}(nT(tilde sign)). The hot kink core moves away from, or perpendicular to, the high density region near q Asymptotically-Equal-To 1, preserving the snake density during a sawtooth crash. The mode resembles the early stage of heavy-impurity-ion snakes in ohmic discharges, including recent observations in Alcator C-Mod. For a larger, more unstable q<1 region, the helical density perturbation drives a conventional 1/1 kink where n aligns with T(tilde sign), leading to a rapid sawtooth crash. The crash redistributes the density to a localized helical concentration inside q Less-Than-Or-Equivalent-To 1, similar to experimentally observed snakes that are initiated by a sawtooth crash.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗