Search NASASearch

SEARCH · Search NASA

Results for “MAGNETOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A LEO Satellite Navigation Algorithm Based on GPS and Magnetometer Data

The Global Positioning System (GPS) has become a standard method for low cost onboard satellite orbit determination. The use of a GPS receiver as an attitude and rate sensor has also been developed in the recent past. Additionally, focus has been given to attitude and orbit estimation using the magnetometer, a low cost, reliable sensor. Combining measurements from both GPS and a magnetometer can provide a robust navigation system that takes advantage of the estimation qualities of both measurements. Ultimately a low cost, accurate navigation system can result, potentially eliminating the need for more costly sensors, including gyroscopes.

Deutschmann, Julie

A Leo Satellite Navigation Algorithm Based on GPS and Magnetometer Data

The Global Positioning System (GPS) has become a standard method for low cost onboard satellite orbit determination. The use of a GPS receiver as an attitude and rate sensor has also been developed in the recent past. Additionally, focus has been given to attitude and orbit estimation using the magnetometer, a low cost, reliable sensor. Combining measurements from both GPS and a magnetometer can provide a robust navigation system that takes advantage of the estimation qualities of both measurements. Ultimately, a low cost, accurate navigation system can result, potentially eliminating the need for more costly sensors, including gyroscopes. This work presents the development of a technique to eliminate numerical differentiation of the GPS phase measurements and also compares the use of one versus two GPS satellites.

Deutschmann, Julie

Optical Magnetometer Incorporating Photonic Crystals

According to a proposal, photonic crystals would be used to greatly increase the sensitivities of optical magnetometers that are already regarded as ultrasensitive. The proposal applies, more specifically, to a state-of-the-art type of quantum coherent magnetometer that exploits the electromagnetically-induced-transparency (EIT) method for determining a small change in a magnetic field indirectly via measurement of the shift, induced by that change, in the hyperfine levels of resonant atoms exposed to the field.

Kulikov, Igor

Miniature Laser Magnetometer

A conceptual design has been developed for a miniature laser magnetometer (MLM) that will measure the scalar magnitude and vector components of near-Earth magnetic fields. The MLM incorporates a number of technical innovations to achieve high-accuracy and high-resolution performance while significantly reducing the size of the laser-pumped helium magnetometer for use on small satellites and unmanned aerial vehicles (UAVs). and electronics sections that has the capability of measuring both the scalar magnetic field magnitude and the vector magnetic field components. Further more, the high-accuracy scalar measurements are used to calibrate and correct the vector component measurements in order to achieve superior vector accuracy and stability. The correction algorithm applied to the vector components for calibration and the same cell for vector and scalar measurements are major innovations. The separate sensor and electronics section of the MLM instrument allow the sensor to be installed on a boom or otherwise located away from electronics and other noisy magnetic components. The MLM s miniaturization will be accomplished through the use of advanced miniaturized components and packaging methods for the MLM sensor and electronics. The MLM conceptual design includes three key innovations. The first is a new non-magnetic laser package that will allow the placement of the laser pump source near the helium cell sensing elements. The second innovation is the design of compact, nested, triaxial Braunbek coils used in the vector measurements that reduce the coil size by a factor of two compared to existing Helmholtz coils with similar field-generation performance. The third innovation is a compact sensor design that reduces the sensor volume by a factor of eight compared to MLM s predecessor.

Slocum, Robert

Plasma Distribution in Mercury's Magnetosphere Derived from MESSENGER Magnetometer and Fast Imaging Plasma Spectrometer Observations

We assess the statistical spatial distribution of plasma in Mercury's magnetosphere from observations of magnetic pressure deficits and plasma characteristics by the MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) spacecraft. The statistical distributions of proton flux and pressure were derived from 10months of Fast Imaging Plasma Spectrometer (FIPS) observations obtained during the orbital phase of the MESSENGER mission. The Magnetometer-derived pressure distributions compare favorably with those deduced from the FIPS observations at locations where depressions in the magnetic field associated with the presence of enhanced plasma pressures are discernible in the Magnetometer data. The magnitudes of the magnetic pressure deficit and the plasma pressure agree on average, although the two measures of plasma pressure may deviate for individual events by as much as a factor of approximately 3. The FIPS distributions provide better statistics in regions where the plasma is more tenuous and reveal an enhanced plasma population near the magnetopause flanks resulting from direct entry of magnetosheath plasma into the low-latitude boundary layer of the magnetosphere. The plasma observations also exhibit a pronounced north-south asymmetry on the nightside, with markedly lower fluxes at low altitudes in the northern hemisphere than at higher altitudes in the south on the same field line. This asymmetry is consistent with particle loss to the southern hemisphere surface during bounce motion in Mercury's offset dipole magnetic field.

magnetic

Exploring the Use of Alfven Waves in Magnetometer Calibration at Geosynchronous Orbit

An Alfven wave is a type magnetohydrodynamicwave that travels through a conducting fluid under the influence of a magnetic field. Researchers have successfully calculated offset vectors of magnetometers in interplanetary space by optimizing the offset to maximize certain Alfvenic properties of observed waves (Leinweber, Belcher). If suitable Alfven waves can be found in the magnetosphere at geosynchronous altitude then these techniques could be used to augment the overall calibration plan for magnetometers in this region such as on the GOES spacecraft, possibly increasing the time between regular maneuvers. Calibration maneuvers may be undesirable because they disrupt the activities of other instruments. Various algorithms to calculate an offset using Alfven waves were considered. A new variation of the Davis-Smith method was derived because it can be mathematically shown that the Davis-Smith method tolerates filtered data, which expands potential applications. The variant developed was designed to find only the offset in the plane normal to the main field because the overall direction of Earth's magnetic field rarely changes, and theory suggests the Alfvenic disturbances occur transverse to the main field. Other variations of the Davis-Smith method encounter problems with data containing waves that propagate in mostly the same direction. A searching algorithm was then designed to look for periods of time with potential Alfven waves in GOES 15 data based on parameters requiring that disturbances be normal to the main field and not change field magnitude. Final waves for calculation were hand-selected. These waves produced credible two-dimensional offset vectors when input to the Davis-Smith method. Multiple two-dimensional solutions in different planes can be combined to get a measurement of the complete offset. The resulting three dimensional offset did not show sufficient precision over several years to be used as a primary calibration method, but reflected changes in the offset fairly well, suggesting that the method could be helpful in monitoring trends of the offset vector when maneuvers cannot be used.

calibration

Variable Permeability Magnetometer Systems and Methods for Aerospace Applications

A magnetometer configured to measure low field strength magnetic fields is provided. Certain embodiments of the magnetometer include a cylindrical coil assembly having a variable permeability core and terminals disposed at both ends. A current source circuit may be operably connected to the terminals and configured to apply a voltage controlled current across the terminals. A voltage readout circuit may be operably connected to the terminals and configured to measure a voltage across the terminals due to the applied current from the current source. An inductance of the coil assembly directly varies as an ambient magnetic field strength varies a permeability of the variable permeability core, and a voltage across the terminals varies directly with the inductance such that the measured voltage across the terminals is a direct measure of the ambient magnetic field strength.

Shams, Qamar A.

Single-Event Effect Testing of the PNI RM3100 Magnetometer for Space Applications

The results of a destructive single-event effect susceptibility radiation test of the PNI RM3100 magnetometer sensor, specifically the MagI 2 C ASIC (application-specific integrated circuit) on the sensor board are presented. The sensor is a low-resource commercial off-the-shelf (COTS) magneto-inductive magnetometer. The device was monitored for destructive events and functional interruptions during exposure to a heavy ion beam at the Lawrence Berkeley National Laboratory's 88′′ Cyclotron. The RM3100 did not experience any destructive single-event effects when irradiated to a total fluence of 1.4 × 10 7 cm −2 at an effective linear energy transfer (LET) of 76.7 MeV cm 2 mg −1 while operated at nominal voltage (3.3 V) and elevated temperature (85 ∘C). When these results are combined with previous total ionizing dose tests showing no failures up to 150 kRad (Si), we conclude that the PNI RM3100 is extremely radiation tolerant and can be used in a variety of space environments.

Mark B. Moldwin

Investigation of the Differences in Onset Times for Magnetically Conjugate Magnetometers

We have identified nearly 1,000 onsets using two pairs of hemispheric conjugate ground magnetometers where the onset is defined based on a sharp decline in the H component of the magnetic field at a ground magnetometer station. Specifically, we used the pair of stations at West Antarctica Ice Sheet Divide and Sanikiluaq, Canada; Syowa, Antarctica; and Tjörnes, Iceland. While the onset time in the southern hemisphere is identified by eye, the value of the differences in the onset time between the northern and southern hemispheres is determined using cross covariance. We observe differences in the onset time between the two hemispheres as large as several minutes, but 53% of the events show no difference in the onset time. Using statistics, we show that the largest differences in onset time are associated with the summer and winter seasons and when the IMF By value is limited between 0.5 and 2.5 nT, which is the IMF By range when the local time difference between the northern and southern hemisphere foot points is the smallest. The results indicate that ionospheric conductivity associated with solar illumination plays a role in the differences in onset time between the northern and southern hemisphere when only non-zero differences in onset time are considered. We validate these results with two other less robust methods. The median value of the differences in onset time indicates that the onsets occur ∼23 s earlier in the winter hemisphere than that in the summer hemisphere. It has been reported that the time difference between the start of the substorm in the magnetotail and the observed auroral break up (substorm auroral onset) in the ionosphere is 30 s to 2 min in the current disruption model and the near earth neutral line model, respectively. Our results may be of interest to those two models.

James M. Weygand

Scalar Atomic Defect-Based Solid-State Self-calibrating Magnetometer (3SM) for Space Plasma Analysis

The Earth’s magnetosphere is a system of multiple, co-located particle populations interacting via plasma waves. Things to understand are driving processes, radiation belt and ring current issues, auroral physics, internal plasma processes, and magnetosphere-ionosphere mapping issues. These plasma-physics processes enable the Earth’s magnetosphere to evolve in response to temporal changes in the solar wind and they underlie the phenomena of space weather, which impacts spacecraft systems, astronauts, radio communications, and ground based electric-power grids. The objective of 3SM is to measure magnetic field strength and to calibrate the Vector Magnetometer (VM) device to maintain absolute accuracy during a mission. The 3SM features make the instrument preferably suited not only for the traditional role of scalar magnetometers as absolute references for the calibration of the on-board vector instruments, but also for extended operational capacities, such as higher frequency scalar measurements (of potential interest for magnetosphere studies for the low frequency part of the spectrum) or autonomous scalar / vector operations. Diamond has been the solid-state platform of choice for quantum device technologies for some time, however, it suffers from difficulties such as scalability, integration, and cost. While the diamond platform is very useful for quantum technologies, further development is needed to make it viable. The material platform of choice for NASA Glenn’s Quantum Sensing And Spin Physics (Q-SASP) is silicon carbide (SiC). This is due to the much higher industry development of the SiC material platform for high-power and high-temperature electronics. It leverages both the decades-long SiC development expertise and infrastructure at NASA Glenn and its growing capabilities in quantum metrology. To make SiC devices usable for quantum technologies such as quantum sources, a much deeper understanding of defects is needed. Q-SASP is developing quantum metrology capabilities to evaluate the energy structure, defect formation energy, band structure augmentation, generation/recombination rates, and limits of dipole-dipole coupling in non-metal implanted SiC devices. This can be achieved by analysis of zero-field splitting, low-field resonance, and singlet-triplet mixing through various forms of Electrically Detectable Magnetic Resonance (EDMR) and Near-Zero Field Magnetic Resonance (NZFMR) spectroscopy. This work will discuss recent system developments, device developments, computational modeling, and spectroscopy results and analysis of defects created by non-metal implantations in SiC devices. The defect formation energies of V Si ,V C , V C V Si , N C V Si , N Si , N C in 4H-SiC are previously reported values in other research [2]-[3]. The defect formation energies of PSi and PC were calculated in GPAW [fig 1A]. The basic underlying mechanism of the zero-field phenomenon is the mixing of singlet and triplet states [4]-[5]. In most spin-dependent transport, two electron spins are involved, and thus one must consider each of their interactions with the field. We investigated the electronic and magnetic properties of 4H-SiC and 6H-SiC. The defect formation energy helps us determine what types of defects we are observing in the SiC EDMR experiment. They have very low formation energy (it is negative). The phosphorus substitution in 4H-SiC is a very stable defect. The band diagrams provide us with vital information about how the electronic properties of SiC (such as band gap) change as we add non-metal defects. The zero-field splitting parameters allow us to study the inflection point in the NZFMR [fig 1B]. We clearly observed zero-field splitting. We also noted that the zero-field splitting remained constant with changing bias. We aspect it zero-field splitting to remain constant while the hyperfine and exchange interaction perturbations shift under the influence of an external magnetic field. This is the essence of quantum magnetometry and self-calibration.

space plasma