Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETOMETERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Impulsive Magnetic Anomaly Detection At the 100-m Scale With an Array of Induction Coil Magnetometers

We demonstrate magnetic anomaly detection (MAD) using an array of 24 commercial induction coil magnetometers with stand-off distances from a pulsed 99.8(3) kA·m 2 magnetic dipole source of 260–1200 m. The sparse array is used to estimate the magnetic dipole location, magnitude, and orientation. We demonstrate how independent component analysis (ICA) improves the accuracy and precision of the magnetometer array when estimating the dipole parameters. Using sensor responses recorded from individual source pulses, we estimate the dipole location to within 29 ± 2 m, the magnitude to within 3 ± 3 kA·m 2 , and dipole orientation error to within 19 ± 0.6°.

47 OTHER INSTRUMENTATION↗

Response induction coil magnetometers to perturbations in orientation

© 1996-2018 Society of Exploration Geophysicists. All rights reserved. We explore the data collected by a 3-component induction coil magnetometer system with respect to motion of the instruments in earths static magnetic field. The sensitivtiy of the inductiuon coil magnetometer leads to unprecediented accuracy on tilt measurements. We model the signals observed during seismic events as being perturbations in coil orientation. In theory, these perturbations can include ground roll, ocean motion, nearby cultural seismicity, or any other field with a tilting effect. Using data from a magnetic observatory near Parkfield CA we invert several time series of coil data during different levels of seismic activity in an attempt to determine the magnitudes of rotation at which our model accurately describes the coil data. Finally, we explore the transfer function between the coils and nearby seismic instruments (accelerometers, tiltmeters, and velocity seismometers).

Kappler, K↗

Brain-computer interfaces enabled by novel magnetometers (CRADA FP00007655 Final Report))

The work primarily focused on improving performance of magnetometers based on Acoustically Driven Ferromagnetic Resonance (ADFMR) as well as exploring and evaluating the market opportunities for such devices. Over the two year program, we were able to improve magnetometer performance by a factor of over 1000X, and were able to demonstrate the feasibility of scaling down a bench-scale implementation by developing a 4” x 4” printed circuit board (PCB) prototype. These advancements were achieved by making substantial improvements both in the core sensor technology as well as the detection circuitry that allows for readout of the sensor module.

42 ENGINEERING↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗

Digital Miniature Cathode Ray Magnetometer

In this study, we introduce the concept and construction of an innovative Digital Miniature Cathode Ray Magnetometer designed for the precise detection of magnetic fields. This device addresses several limitations inherent to magnetic probes such as D.C. offset, nonlinearity, temperature drift, sensor aging, and the need for frequent recalibration, while capable of operating in a wide range of magnetic fields. The core principle of this device involves the utilization of a charged particle beam as the sensitivity medium. The system leverages the interaction of an electron beam with a scintillator material, which then emits visible light that is captured by an imager. The emitted scintillation light is captured by a CMOS sensor. This sensor not only records the scintillation light but also accurately determines the position of the electron beam, providing invaluable spatial information crucial for magnetic field mapping. The key innovation lies in the combination of electron beam projection, CMOS imager scintillation-based detection, and digital image signal processing. By employing this synergy, the magnetometer achieves remarkable accuracy, sensitivity and dynamic range. The precise position registration enabled by the CMOS sensor further enhances the device’s utility in capturing complex magnetic field patterns, allowing for 2D field mapping. In this work, the optimization of the probe’s performance is tailored for applications related to the characterization of insertion devices in light sources, including undulators.

Turqueti, Marcos↗

Radiation tolerance of the PNI RM3100 magnetometer for a Europa lander mission

The results of two radiation test campaigns on a low-cost commercial off-the-shelf magnetometer are presented. The test setup and the total ionization dose (TID) levels studied were designed to meet the requirements of a mission to land on Europa. Based on the Europa Lander Science Definition Team report, instruments inside an aluminum vault at the surface of Europa would need to withstand TID of up to 300 krad(SI). In order to evaluate the performance of the PNI RM3100 magnetometer, nine separate sensors were irradiated at two different facilities during two separate campaigns and under different configurations, including passive and active tests. Of the nine sensors, seven survived the TID of 300 krad(SI) while the other two sensors started presenting failures after reaching 150 krad(SI). Post-irradiation tests showed that eight of the nine sensors continued to work without appreciable degradation after stopping exposure, while one sensor stopped working altogether.

58 GEOSCIENCES↗

Improved magnetometer uses toroidal gating coil

Improved magnetometer employs a cylindrical, high permeability magnetic core with a toroidal gating coil and a solenoid pickup coil. Flux interaction can be reduced by electrostatically shielding the pickup coil from the gating coil. The magnetometer principle can be applied to navigation devices.

Source record↗

Two-axis flux gate magnetometer

Magnetometer uses single sensing head to measure magnetic flux density along two axes simultaneously. The sensor head consists of permalloy core and four windings. Two windings perform a multivibrator function, the two remaining windings sense magnetic fields. The smaller magnetometer performs same functions as more complex devices.

Acuna, M. H.↗

The particles and fields subsatellite magnetometer experiment

A preliminary analysis of magnetometer data from Apollo 15 subsatellite is concluded. Remanent magnetization is a characteristic property of the moon, and the distribution is such that a complex pattern is produced. A mapping of the distribution is feasible with the present experiment. Lunar induction fields produced by transients in interplanetary magnetic field are detectable at satellite orbit. Magnetometer data will provide estimates of the latitude and longitude dependences of interior conductivity. The plasma void extends to some altitude below the satellite orbit and probably the lunar surface. Solar wind near the limbs is usually strongly disturbed.

Coleman, P. J., Jr.↗

Properties of crystalline bismuth selenide and its use as a Hall effect magnetometer

Single crystals of n-type Bi2Se3 grown by the Bridgman technique are found to make excellent Hall effect magnetometers. Plots of Hall resistivity sub yx against magnetic field B to 10 tesla are linear to within 1 percent. Furthermore, the slope of the sub yx against B curve varies by about 1 percent in the region 1.1 to 35 K and by less than 20 percent in the region 1.1 to 300 K. Analysis of galvanomagnetic measurements indicate the samples have semimetallic densities of approximately 10 to the 25th power/cu cm, with two band conduction and near carrier compensation. Reflectivity measurements suggest a band gap of approximately 0.08 eV for the samples. The temperature dependence of mobility is also measured. A series of 50 direct immersions into liquid helium and liquid nitrogen demonstrate the reliability of Bi2Se3 magnetometers for cryogenic use.

Wollam, J. A.↗

The particles and fields subsatellite magnetometer experiment

It is reported that the objectives of the particles and fields subsatellite (PFS) magnetometer experiment are to calculate the interior electrical conductivity of the moon, to survey the remanent magnetization of the lunar surface, and to study the interaction of the moon with its plasma environment. The magnetometers also support the PFS particle experiment by providing onboard magnetic sectoring and a posteriori pitch angle data and plasma diagnostics.

Coleman, P. J., Jr.↗

Magnetometer with miniature transducer and automatic transducer scanning apparatus

Magnetometer is simple to operate and has fast response. Transducer is rugged and flat and can measure magnetic fields as close as 0.08 mm from any relatively flat surface. Magnetometer has active region of approximately 0.64 by 0.76 mm and is capable of good spatial resolution of magnetic fields as low as 0.02 Oe (1.6 A/m).

Breckenridge, R. A.↗

Apollo particles and fields subsatellite magnetometer experiment

The results of the Apollo 15 subsatellite magnetometer experiment are reported. The magnetometer is described including the operation, and specifications. Orbit plots presented are altitude versus time, selenographic longitude versus latitude, and the ecliptic projection of the earth-moon system. The lunar magnetic field, solar wind interaction with the moon, the transfer function of the moon, and the plasma sheet interaction with the moon are discussed.

Coleman, P. J., Jr.↗

Hall effect magnetometer

A magnetometer which uses a single crystal of bismuth selenide is described. The rhombohedral crystal structure of the sensing element is analyzed. The method of construction of the magnetometer is discussed. It is stated that the sensing crystal has a positive or negative Hall coefficient and a carrier concentration of about 10 to the 18th power to 10 to the 20th power per cubic centimeter.

Woollam, J. A.↗

Vector magnetometer as an attitude determining instrument

The solid state vector magnetometer sensor system is presented for the accuracy and reliability of existing systems, and for providing independent measures of attitude. Since a large number of aircraft heading reference systems depend on measurement of the earth's magnetic field, it can be shown that by substituting a 3-axis magnetometer for the remote sensing unit, both heading and attitude measurement functions can be derived using common elements. Sample calculations are made using the earth's magnetic field data acquired during actual flight conditions.

Pietila, R.↗

Apollo 12, 15, and 16 lunar surface magnetometer experiment data analysis

The polarization of magnetometer signals detected at the Apollo 15 Hadley site by the lunar surface magnetometer has been studied to determine the source of the signal anisotropy which is observed and caused by the polarization. Instrument and data chain malfunction (cross-talk) seems ruled out. The source appears real and apparently connected with the Imbrium basin using reasonable inferences regarding the electromagnetic structure of the Moon. A theory is developed using moons with holes and conducting caps where the Imbrium basin is; results of calculations are consistent, though not unique, in specifying an anomaly in the electrical conductivity underlying Mare Imbrium. Distinct differences are noted from plasma sheet and diamagnetic cavity transfer functions, but the lobes appear, as for all other data, not to be vacuum for study of the moon. A discussion is given of problems connected with transfer of data, software, and theoretical programs from NASA Ames Research Center to the University of Arizona, and a summary is given of the conversion from IBM to CDC formats.

Sonett, C. P.↗

Performance characteristics of a three-axis superconducting rock magnetometer

A series of measurements are carried out with the purpose of quantitatively determining the characteristics of a commercial 6.8 cm access superconducting rock magnetometer located in the magnetic properties laboratory at the Goddard Space Flight Center. The measurements show that although a considerable improvement in measurement speed and signal to noise ratios can be obtained using such an instrument, a number of precautions are necessary to obtain accuracies comparable with more conventional magnetometers. These include careful calibration of the sensor outputs, optimum positioning of the sample within the detection region and quantitatively establishing the degree of cross-coupling between the detector coils. In order to examine the uniformity of response for each detector, the responses are mapped as a function of position, using a small dipole.

Lienert, B. R.↗