Guidelines for Home Energy Professionals: Standard Work Specifications (SWS) Maintenance Charter and Procedures
This Standard Work Specifications (SWS) Maintenance Charter and Procedures outlines the policies and procedures for SWS.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This Standard Work Specifications (SWS) Maintenance Charter and Procedures outlines the policies and procedures for SWS.
This report assesses four major LED package platforms used in SSL applications for luminous flux and chromaticity maintenance by analyzing data sets from LM-80 testing of representative products from many Tier 1 LED manufacturers.
The overall objective was to develop additive-manufacturing-enabled repair solutions for last stage bucket (LSB) and additive-manufacturing-enabled packing rings (PRs) for coal-fired steam turbines with the goal of reducing routine maintenance, repair, and overhaul (MRO) cost and improving the operating efficiency of steam turbines. GE Steam Power (GESP) and GE Gas Power (GEGP) provided technical and commercial consulting to GER with insights on steam turbine MRO design requirements, MRO duration and costs, and an overall commercialization strategy for the additive manufacturing technologies developed in the proposed effort.
Battery storage systems are increasingly being installed at photovoltaic (PV) sites to address supply-demand balancing needs. Although there is some understanding of costs associated with PV operations and maintenance (O&M), costs associated with emerging technologies such as PV plus storage lack details about the specific systems and/or activities that contribute to the cost values. This study aims to address this gap by exploring the specific factors and drivers contributing to utility-scale PV plus storage systems (UPVS) O&M activities costs, including how technology selection, data collection, and related and ongoing challenges. Specifically, we used semi-structured interviews and questionnaires to collect information and insights from utility-scale owners and operators. Data was collected from 14 semi-structured interviews and questionnaires representing 51.1 MW with 64.1 MWh of installed battery storage capacity within the United States (U.S.). Differences in degradation rate, expected life cycle, and capital costs are observed across different storage technologies. Most O&M activities at UPVS related to correcting under-performance. Fires and venting issues are leading safety concerns, and owner operators have installed additional systems to mitigate these issues. There are ongoing O&M challenges due the lack of storage-specific performance metrics as well as poor vendor reliability and parts availability. Insights from this work will improve our understanding of O&M consideration at PV plus storage sites.
We exist to inspire reliable processes so that people feel safe, secure, and effective every day. Our mission is to utilize Reliability-centered Maintenance and Reliability Engineering principles in partnership with cross-functional cooperation to assure a common goal is safely achieved.
The U.S. Department of Energy (DOE) Office of Legacy Management (LM) prepared this Long-Term Surveillance and Maintenance Plan (LTS&M Plan) for the Salmon, Mississippi, Site (the Salmon site) to describe LM’s plan and policy for future site activities. The Salmon site consists of 1470 acres in Lamar County, Mississippi, approximately 10 miles west of Purvis, Mississippi, and about 21 miles southwest of Hattiesburg, Mississippi. The site is located over a large subsurface salt formation referred to as the Tatum Salt Dome. Two nuclear tests (Project Dribble) and two gas explosive tests (Project Miracle Play) were conducted in the salt dome between 1964 and 1970. Salmon, the first nuclear test, was conducted on October 22, 1964, and created a cavity approximately 2700 feet (ft) below ground surface (bgs). The second nuclear test, Sterling, was conducted on December 3, 1966. The Sterling test and the two gas explosions—Diode Tube on February 2, 1969, and Humid Water on April 19, 1970—were all conducted in the cavity created by the Salmon test. The four explosions were conducted as part of the U.S. Atomic Energy Commission’s (AEC’s) Vela Uniform program. Testing at the site ended in 1970 after the second gas detonation. The tests resulted in residual contamination and postdetonation features that require long-term oversight.
The purpose of the proposed work was to address issues expected to be encountered in commercial applications of the PRO-AID physics-based monitoring capability to minimize operations and maintenance (O&M) costs. O&M costs represent the largest fixed cost item for existing commercial reactors and new reactor designs.
At the 2024 Photovoltaic (PV) Performance Modeling Workshop we collected user stories related to PV system monitoring, analytics, and operations and maintenance (O&M). In this context, user stories describe challenges with current practices and tools or imagining opportunities for improvements. From these user stories, we identified several near-term opportunities to improve photovoltaic system monitoring, analytics and O&M.
Hydrogen-powered locomotives may present an alternative to diesel for achieving transportation-related decarbonization, energy security, and resilience goals. As an emerging technology, hydrogen locomotives may not have adequate representation in current safety codes and standards. NFPA 2 and other appropriate codes and standards were reviewed to identify technical gaps in the code for hydrogen rail defueling, refueling, maintenance, and storage. Several technical gaps pertaining to setback distances, allowable quantities, ventilation rates, and grounding have been identified. Fueling requirements can be informed by road vehicle standards but may need to be revised for larger quantity hydrogen locomotive systems. Since there are no hydrogen-specific locomotive design and safety standards, some aspects of diesel-based locomotive standards may apply. CGA G- 5.5 currently provides the most guidance on height, placement, orientation, and design of vent systems, while other standards emphasize the importance of shielding vent stacks and provide requirements for orientation of their discharge.
Photovoltaic (PV) systems are essential for the transition to sustainable energy, reducing fossil fuel dependence and mitigating climate change. Although PV requires minimal land area — PV can meet the European Union's energy needs using only 0.26% of its land — space for deployment is often scarce in densely populated regions. Floating photovoltaics (FPV) offer an effective solution to land-use challenges by installing PV systems on floating structures in water bodies. FPV is a growing niche within PV with a cumulative installed capacity reaching 7.7 GW globally by 2023. Almost 90% of the installed FPV capacity is in Asia, with close to 50% of in China alone, while the Netherlands and France are the largest markets outside Asia. FPV shows strong potential to support climate targets, but still faces challenges like regulatory barriers, cost competitiveness compared to ground-based PV (GPV), and uncertainties about environmental impacts and system reliability. FPV systems are currently installed mainly on sheltered inland waters, such as quarry lakes, irrigation ponds and reservoirs. FPV technical standards are still being developed. Guidelines have been published by the World Bank, DNV, and Solar Power Europe, and emerging national standards from South Korea, China, and Singapore address design, components, and safety. The International Electrotechnical Commission (IEC) is working on formal standards for floats, mooring systems, and electrical connectors. However, the published best practices lack quantitative guidance for yield modelling and reliability, which this report aims to address. It provides data-driven insights, models, and parameters essential for accurate energy yield, reliability, and maintenance predictions over FPV systems' lifetimes.
This report documents the operations, maintenance, and improvements that were performed at the Mechanisms Engineering Test Loop (METL) and its supporting infrastructure during FY2024. The METL facility had a very successful seventh year of operations while supporting the testing of multiple test article experiments in the facility. The METL facility continued supporting the Gear Test Assembly (GTA) testing and the Thermal Hydraulic Experimental Test Article (THETA) with the full testing with both the primary and secondary systems. Work to accommodate two additional experiments, a flow sensor test article (F-STAr) gripper test and a fuel handling gripper test article (GrTA) continued as they are expected to undergo testing in METL in FY2025. In addition, a new 18” test article, the Sample Testing Basket (STB) was used a few times to provide screening tests for sodium service materials. A fifth test vessel was installed in the location of Test Vessel 6, and a wet vapor nitrogen sodium processing system was developed and initially tested.
The primary objective of this project is to improve machining process performance using in-process machining data from the machine tool controller and external sensors. Advances in the Industrial Internet of Things (IIoT) enable monitoring of machines using controller data. Examples of the data provided by a controller include execution status of the controller, part count, block of code being executed, door status, tool position, the spindle and axis load, etc. MTConnect and OPC-UA are the two common protocols for capturing machine information. In this collaboration, methods for retrieving the machine controller data from selected machine tool controls and making these data accessible in different subsystems (such as digital twins and machine maintenance portals, etc.) will be developed and tested. In addition, analytics to improve machining process performance (by increasing productivity and reducing downtime) will be developed.
The Federal Railroad Administration (FRA) contracted Sandia National Laboratories to review the risks introduced specifically through human interactions within hydrogen rail refueling and maintenance activities and present recommendations for future system development and implementation. Due to the lack of domestic hydrogen-powered trains at the time of review, observational data was collected on analogous existing systems to consider various ways hydrogen might be implemented within future designs. The team developed 50 human factors design guidelines through analysis of human risk factors. Because hydrogen rail systems are still in the early design stage, the resulting human factors guidelines represent general best practices and do not include specific design features. The research team recommends design and regulatory agencies include a Human Factors Engineer in the design and review process to ensure the guidelines are appropriately implemented and verified.
Apparatus and method for manufacturing an air maintenance tire includes an air pumping tube assembly station constructing an air pumping tube sub-assembly, a tire preparation station for forming passageways in the tire to accept an outlet device of the air pumping tube sub-assembly, an air pumping tube sub-assembly installation station and a pressure regulator installation station. The air pumping tube sub-assembly inserts into an elongate tire groove opening, facilitated by groove-spreading apparatus.
The primary objective of this research is to address challenges in the implementation of risk-informed, condition-based predictive maintenance (PdM), which reduces operating costs while still maintaining the safety and reliability of commercial nuclear power plants (NPPs). To achieve the objective, risk models are being developed by taking advantage of advancements in data analytics, deep learning, machine learning (ML), and artificial intelligence (AI). The notable outcomes presented in the report include ? Development of a ML models using heterogeneous plant process and vibration data collected at different spatial and temporal resolutions from the Salem?s CWS to diagnose a circulating water pump (CWP) failure based on salient fault signatures. The developed diagnostic models are extendable to other faults associated with CWPs and CWP motors given associated fault signatures. ? Development of a natural language processing (NLP) technique to automatically classify the WO data into different categories. The developed NLP technique was validated on independent WO data. This automates the tedious and time-consuming activity of mining and classifying WOs by subject matter experts. ? Estimation of mean time between downtime (i.e., time duration between time instances when 1 or more CWPs are not available) and developed an approach to establish reliability of CWS components using unstructured WO data along with CWS plant process data. ? Formulation of economic model based on Markov chain models. The parameters of associated with the transition rate between different states of Markov chain models were estimated using WO data. The economic model formulation and discussion captures both time-independent and time-dependent parameter variation, leading to risk-informed decision-making.
Global wind industry has experienced tremendous growth during the past two decades and the trend does not appear changing in near future. However, the industry is still challenged by premature component failures and high operations & maintenance (O&M) costs, which can account for up to 35% of levelized cost of energy. It is imperative for the industry to improve performance, reliability and reduce O&M costs through advanced technologies, enabled by research in related disciplines, to be competitive. This talk will first briefly discuss the challenges with wind plant O&M, then give an overview of related NREL research in the areas of performance, reliability, and O&M cost modeling, finally touch on future R&D opportunities in related areas. The authors hope some of these challenges are of interested to and can be addressed by the INFORMS community in future.
This report documents the Hazardous Waste Management Act (HWMA)/ Resource Conservation and Recovery Act (RCRA) Partial Closure Certification of the Sodium Components Maintenance Shop (SCMS) Carbonation Vessel. The HWMA/RCRA Closure followed the multi step review and evaluation closure process identified in the Idaho National Laboratory (INL) Materials and Fuels Complex (MFC) HWMA/RCRA Partial Permit Closure Plan, October 1, 2015. This closure certification report documents that the SCMS Carbonation Vessel was removed from the SCMS, packaged as hazardous waste and stored for future treatment and disposal, and therefore has met the closure performance standards in accordance with the Department of Energy Idaho National Laboratory Materials and Fuels Complex HWMA/RCRA Partial Permit Closure Plan (EPA No. ID4890008952, October 1, 2015).
The P- and R-Area Reactor buildings, located at SRS near Aiken, SC, were in-situ decommissioned by grouting below-grade portions of the buildings and demolishing some above-grade structures to grade level. Other reactor building structures were left above-grade and sealed to prevent human or animal access. Because the above grade-structures are expected to continue in their present state for hundreds of years, the condition of the building roofs is critical to mitigate rainwater intrusion. For this reason, building roof areas were strengthened with high strength concrete to ensure the long-term integrity of the roof structure. Periodic inspections of the roof structures are required to ensure that the roofs are functioning properly and to identify damage areas. The traditional method of inspecting closed reactor buildings requires the use of a helicopter and photographer to generate photographs and videos for review. This method proved sufficient but lacked the resolution and clarity that is required for a thorough inspection of the building structure. Fortunately, the Savannah River National Laboratory (SRNL) has established a Small Unmanned Aircraft System (sUAS) program using commercially available and custom-built remote-controlled aircraft. EC and ACP contacted the SRNL program to evaluate whether the sUAS technology could be employed for periodic reactor building inspections. The sUAS can fly within a few meters of the reactor buildings and hover, allowing for a more thorough aerial inspection. The initial sUAS inspection of the P-Area Reactor building was completed in February 2018 and at the R-Area Reactor building in August 2018 and were successful in providing higher resolution photos and videos. The sUAS inspections also revealed that vegetation had begun to grow on the roofs that could potentially damage the structure integrity. SRNL partnered with Virginia Polytechnic Institute and State University to build a custom heavy lift sUAS that could be equipped with herbicides to remotely treat the vegetative growth. Herbicides were successfully applied to the R-Area Reactor building roof using the custom sUAS in September 2018. The use of unmanned aircraft systems at SRS to perform aerial inspections and herbicide treatment in otherwise inaccessible areas has proven to be an efficient and cost-effective technology that provides high value, increases knowledge of facility conditions, and provides for early detection of damage. Periodic inspections of the reactor building roofs using sUAS technology are performed safely, efficiently, and at a significant cost and schedule savings while reducing emissions, noise, and fossil fuel use. The use of sUAS equipment for building inspections and herbicide application at SRS is unique within the DOE complex. The goal of SRS is to apply this remote technology to other waste unit operations and maintenance activities in the future. (authors)