Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASS FLOW RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

On Characterization of Laminar to Turbulent Transitional Flow in the Truncated IHF Semi-Elliptical Nozzle

This paper reports computational analysis and experimental data to characterize the laminar to turbulent flow transition in a high-enthalpy panel test facility at NASA Ames Research Center. The recently developed facility configuration uses a truncated version of an existing semi-elliptical nozzle in the 60-MW Interaction Heating Facility, and it provides testing capability for panel test articles as large as 43.2 cm x 43.2 cm (17 in x 17 in). A water-cooled calibration plate, which is attached to the semi-elliptical nozzle bottom surface and instrumented with twenty Gardon-gage heat flux calorimeters and twelve pressure gages, is used to characterize the convective heating environment over the panel test articles. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, and the flowfields over panel test articles, and comparisons with the measured test data. Both laminar and turbulent simulations are performed. Constant current studies are performed: the measured data are grouped at the same arc current levels with varying mass flow rates, and they are compared with corresponding computations. For all currents studied, these studies indicate that the semi-elliptical nozzle flow is transitional at relatively higher mass flow rates within the facility operating envelope.

Arc-jets↗

On Characterization of Laminar to Turbulent Transitional Flow in the Truncated IHF Semi-Elliptical Nozzle

This paper reports computational analysis and experimental data to characterize the laminar to turbulent flow transition in a high-enthalpy panel test facility at NASA Ames Research Center. The recently developed facility configuration uses a truncated version of an existing semi-elliptical nozzle in the 60-MW Interaction Heating Facility, and it provides testing capability for panel test articles as large as 43.2 cm x 43.2 cm (17 in x 17 in). A water-cooled calibration plate, which is attached to the semi-elliptical nozzle bottom surface and instrumented with twenty Gardon-gage heat flux calorimeters and twelve pressure gages, is used to characterize the convective heating environment over the panel test articles. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, and the flowfields over panel test articles, and comparisons with the measured test data. Both laminar and turbulent simulations are performed. Constant current studies are conducted: the measured data are grouped at the same arc current levels with varying mass flow rates, and they are compared with corresponding computations. For all currents considered, these studies indicate that the semi-elliptical nozzle flow is transitional at relatively higher mass flow rates within the facility operating envelope. An approximate facility map for the transitional flow characterization is developed, showing laminar and transitional to turbulent flow regions.

Arc-jets↗

Liquid Oxygen/Liquid Methane Test Results of the RS-18 Lunar Ascent Engine at Simulated Altitude Conditions at NASA White Sands Test Facility

Tests were conducted with the RS-18 rocket engine using liquid oxygen (LO2) and liquid methane (LCH4) propellants under simulated altitude conditions at NASA Johnson Space Center White Sands Test Facility (WSTF). This project is part of NASA's Propulsion and Cryogenics Advanced Development (PCAD) project. "Green" propellants, such as LO2/LCH4, offer savings in both performance and safety over equivalently sized hypergolic propulsion systems in spacecraft applications such as ascent engines or service module engines. Altitude simulation was achieved using the WSTF Large Altitude Simulation System, which provided altitude conditions equivalent up to ~122,000 ft (~37 km). For specific impulse calculations, engine thrust and propellant mass flow rates were measured. LO2 flow ranged from 5.9 - 9.5 lbm/sec (2.7 - 4.3 kg/sec), and LCH4 flow varied from 3.0 - 4.4 lbm/sec (1.4 - 2.0 kg/sec) during the RS-18 hot-fire test series. Propellant flow rate was measured using a coriolis mass-flow meter and compared with a serial turbine-style flow meter. Results showed a significant performance measurement difference during ignition startup due to two-phase flow effects. Subsequent cold-flow testing demonstrated that the propellant manifolds must be adequately flushed in order for the coriolis flow meters to give accurate data. The coriolis flow meters were later shown to provide accurate steady-state data, but the turbine flow meter data should be used in transient phases of operation. Thrust was measured using three load cells in parallel, which also provides the capability to calculate thrust vector alignment. Ignition was demonstrated using a gaseous oxygen/methane spark torch igniter. Test objectives for the RS-18 project are 1) conduct a shakedown of the test stand for LO2/methane lunar ascent engines, 2) obtain vacuum ignition data for the torch and pyrotechnic igniters, and 3) obtain nozzle kinetics data to anchor two-dimensional kinetics codes. All of these objectives were met with the RS-18 data and additional testing data from subsequent LO2/methane test programs in 2009 which included the first simulated-altitude pyrotechnic ignition demonstration of LO2/methane.

Melcher, John C., IV↗

A phenomenological model for orificed hollow cathodes

A quartz hollow tube cathode was used to determine the operating conditions within a mercury orificed hollow cathode. Insert temperature profiles, cathode current distributions, plasma properties profile, and internal pressure-mass flow rate results are summarized and used in a phenomenological model which qualitatively describes electron emission and plasma production processes taking place within the cathode. By defining an idealized ion production region within which most of the plasma processes are concentrated, this model is expressed analytically as a simple set of equations which relate cathode dimensions and specifiable operating conditions, such as mass flow rate and discharge current, to such important parameters as emission surface temperature and internal plasma properties. Key aspects of the model are examined.

Siegfried, D. E.↗

High power arcjet

In this period a new mass flow controller was brought into the gas supply system, so that the upper limit for the mass flow rate could be increased up to 500 mg/s with hydrogen. A maximum specific impulse of 1500 s could be achieved with the high powered arcjet (HIPARC) at an efficiency of slightly better than 20 percent. Different nozzle throat diameters had been tested. The 100 kilo-watt input power limit was reached with the 4 mm nozzle throat diameter at a mass flow rate of 400 mg/s. Tests were carried out with different cathode gaps and with three different cathodes. In addition measurements of pressure and gas temperature were taken in the feed line in order to determine the pressure drop in the propellant injectors.

Goelz, T. M.↗

Low power arcjet performance

An experimental investigation was performed to evaluate arc jet operation at low power. A standard, 1 kW, constricted arc jet was run using nozzles with three different constrictor diameters. Each nozzle was run over a range of current and mass flow rates to explore stability and performance in the low power engine. A standard pulse-width modulated power processor was modified to accommodate the high operating voltages required under certain conditions. Stable, reliable operation at power levels below 0.5 kW was obtained at efficiencies between 30 and 40 percent. The operating range was found to be somewhat dependent on constrictor geometry at low mass flow rates. Quasi-periodic voltage fluctuations were observed at the low power end of the operating envelope, The nozzle insert geometry was found to have little effect on the performance of the device. The observed performance levels show that specific impulse levels above 350 seconds can be obtained at the 0.5 kW power level.

Curran, Francis M.↗

Low power arcjet performance

An experimental investigation was performed to evaluate arcjet operation at low power. A standard, 1 kW, constricted arcjet was run using nozzles with three different constrictor diameters. Each nozzle was run over a range of current and mass flow rates to explore stability and performance in the low power regime. A standard pulse-width modulated power processor was modified to accommodate the high operating voltages required under certain conditions. Stable, reliable operation at power levels below 0.5 kW was obtained at efficiencies between 30 and 40 percent. The operating range was found to be somewhat dependent on constrictor geometry at low mass flow rates. Quasi-periodic voltage fluctuations were observed at the low power end of the operating envelope. The nozzle insert geometry was found to have little effect on the performance of the device. The observed performance levels show that specific impulse levels above 350 seconds can be obtained at the 0.5 kW power level.

Curran, Francis M.↗

Investigation of Instabilities and Heat Transfer Phenomena in Supercritical Fuels at High Heat Flux and Temperatures

A series of heated tube experiments was performed to investigate fluid instabilities that occur during heating of supercritical fluids. In these tests, JP-7 flowed vertically through small diameter tubes at supercritical pressures. Test section heated length, diameter, mass flow rate, inlet temperature, and heat flux were varied in an effort to determine the range of conditions that trigger the instabilities. Heat flux was varied up to 4 BTU/sq in./s, and test section wall temperatures reached as high as 1950 F. A statistical model was generated to explain the trends and effects of the control variables. The model included no direct linear effect of heat flux on the occurrence of the instabilities. All terms involving inlet temperature were negative, and all terms involving mass flow rate were positive. Multiple tests at conditions that produced instabilities provided inconsistent results. These inconsistencies limit the use of the model as a predictive tool. Physical variables that had been previously postulated to control the onset of the instabilities, such as film temperature, velocity, buoyancy, and wall-to-bulk temperature ratio, were evaluated here. Film temperatures at or near critical occurred during both stable and unstable tests. All tests at the highest velocity were stable, but there was no functional relationship found between the instabilities and velocity, or a combination of velocity and temperature ratio. Finally, all of the unstable tests had significant buoyancy at the inlet of the test section, but many stable tests also had significant buoyancy forces.

Linne, Diane L.↗

Reduction of Altitude Diffuser Jet Noise Using Water Injection

A feasibility study on the effects of injecting water into the exhaust plume of an altitude rocket diffuser for the purpose of reducing the far-field acoustic noise has been performed. Water injection design parameters such as axial placement, angle of injection, diameter of injectors, and mass flow rate of water have been systematically varied during the operation of a subscale altitude test facility. The changes in acoustic far-field noise were measured with an array of free-field microphones in order to quantify the effects of the water injection on overall sound pressure level spectra and directivity. The results showed significant reductions in noise levels were possible with optimum conditions corresponding to water injection at or just upstream of the exit plane of the diffuser. Increasing the angle and mass flow rate of water injection also showed improvements in noise reduction. However, a limit on the maximum water flow rate existed as too large of flow rate could result in un-starting the supersonic diffuser.

Allgood, Daniel C.↗

Reduction of Altitude Diffuser Jet Noise Using Water Injection

A feasibility study on the effects of injecting water into the exhaust plume of an altitude rocket diffuser for the purpose of reducing the far-field acoustic noise has been performed. Water injection design parameters such as axial placement, angle of injection, diameter of injectors, and mass flow rate of water have been systematically varied during the operation of a subscale altitude test facility. The changes in acoustic far-field noise were measured with an array of free-field microphones in order to quantify the effects of the water injection on overall sound pressure level spectra and directivity. The results showed significant reductions in noise levels were possible with optimum conditions corresponding to water injection at or just upstream of the exit plane of the diffuser. Increasing the angle and mass flow rate of water injection also showed improvements in noise reduction. However, a limit on the maximum water flow rate existed as too large of flow rate could result in un-starting the supersonic diffuser.

Allgood, Daniel C.↗

Adjoint-Based Mesh Adaptation and Shape Optimization for Simulations with Propulsion

Objectives: Reliable evaluation of mass flow rates through permeable boundaries - Estimate and control discretization error- Consider both computational domain outflow and inflow- Applicable to simulating propulsion-system effects, as well as secondary flow paths - Explore feasibility of handling more general outputs at domain boundaries. Design optimization subject to mass-flow-rate constraints - Improve aerodynamic performance and reduce noise due to sonic boom - Control discretization error in design space to improve confidence in final designs.

Nemec, Marian↗

Flow processes in electric discharge drivers

The performance of an electric discharge shock tube is discussed from the point of view that the conditions at the sonic station are the primary controlling variables (likewise in comparing designs), and that the analysis of the flow on either side of the sonic station should be done separately. The importance of considering mass-flow rate in matching a given driver design to the downstream flow required for a particular shock-wave speed is stressed. It is shown that a driver based on the principle of liquid injection (of H2) is superior to one based on the Ludwieg tube, because of the greater mass-flow rate and the absence of a massive diaphragm.

Baganoff, D.↗

Hydrocarbon-fuel/combustion-chamber-liner materials compatibility

The results of dynamic tests using methane and NASA-Z copper test specimen under conditions that simulate those expected in the cooling channels of a regeneratively cooled LOX/hydrocarbon booster engine operating at chamber pressures up to 3000 psi are presented. Methane with less than 0.5 ppm sulfur contamination has little or no effect on cooling channel performance. At higher sulfur concentrations, severe corrosion of the NASA-Z copper alloy occurs and the cuprous sulfide Cu2S, thus formed impedes mass flow rate and heat transfer efficiency. Therefore, it is recommended that the methane specification for this end use set the allowable sulfur content at 0.5 ppm (max). Bulk high purity liquid methane that meets this low sulfur requirement is currently available from only one producer. Pricing, availability, and quality assurance are discussed in detail. Additionally, it was found that dilute sodium cyanide solutions effectively refurbish sulfur corroded cooling channels in only 2 to 5 minutes by completely dissolving all the Cu2S. Sulfur corroded/sodium cyanide refurbished channels are highly roughened and the increased surface roughness leads to significant improvements in heat transfer efficiency with an attendant loss in mass flow rate. Both the sulfur corrosion and refurbishment effects are discussed in detail.

Homer, G. David↗

Numerical Simulations of the Steady and Unsteady Aerodynamic Characteristics of a Circulation Control Wing Airfoil

The aerodynamic characteristics of a Circulation Control Wing (CCW) airfoil have been numerically investigated, and comparisons with experimental data have been made. The configuration chosen was a supercritical airfoil with a 30 degree dual-radius CCW flap. Steady and pulsed jet calculations were performed. It was found that the use of steady jets, even at very small mass flow rates, yielded a lift coefficient that is comparable or superior to conventional high-lift systems. The attached flow over the flap also gave rise to lower drag coefficients, and high L/D ratios. Pulsed jets with a 50% duty cycle were also studied. It was found that they were effective in generating lift at lower reduced mass flow rates compared to a steady jet, provided the pulse frequency was sufficiently high. This benefit was attributable to the fact that the momentum coefficient of the pulsed jet, during the portions of the cycle when the jet was on, was typically twice as much as that of a steady jet.

Liu, Yi↗

Reduction of turbomachinery noise

In the invention, propagating broad band and tonal acoustic components of noise characteristic of interaction of a turbomachine blade wake, produced by a turbomachine blade as the blade rotates, with a turbomachine component downstream of the rotating blade, are reduced. This is accomplished by injection of fluid into the blade wake through a port in the rotor blade. The mass flow rate of the fluid injected into the blade wake is selected to reduce the momentum deficit of the wake to correspondingly increase the time-mean velocity of the wake and decrease the turbulent velocity fluctuations of the wake. With this fluid injection, reduction of both propagating broad band and tonal acoustic components of noise produced by interaction of the blade wake with a turbomachine component downstream of the rotating blade is achieved. In a further noise reduction technique, boundary layer fluid is suctioned into the turbomachine blade through a suction port on the side of the blade that is characterized as the relatively low-pressure blade side. As with the fluid injection technique, the mass flow rate of the fluid suctioned into the blade is here selected to reduce the momentum deficit of the wake to correspondingly increase the time-mean velocity of the wake and decrease the turbulent velocity fluctuations of the wake; reduction of both propagating broad band and tonal acoustic components of noise produced by interaction of the blade wake with a turbomachine component downstream of the rotating blade is achieved with this suction technique. Blowing and suction techniques are also provided in the invention for reducing noise associated with the wake produced by fluid flow around a stationary blade upstream of a rotating turbomachine.

Waitz, Ian A.↗

Analysis of Probe Surveys Conducted in the 10-MW TP3 Arc-Jet Facility 15-Inch Nozzle Flow

Computational simulations and analysis of flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center are reported. These tests were conducted in the 10-MW TP3 facility 15-inch conical nozzle, and pitot pressure and heat flux probes are used to survey test flow downstream of the nozzle exit. Two 1.59-cm (0.625 in) diameter hemisphere probes were used: one with a stagnation-point pressure port, the other with a Gardon heat flux gage. Calibration data were also obtained using 10.16-cm iso-q and 20.32-cm flat-faced slug calorimeters. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were obtained at eight arc-heater conditions, covering wide ranges in arc current (316–1756 A) and mass flow rate (32–500 g/s, without any cold-gas injection at the arc-heater plenum) and providing assessment of the flow uniformity in the facility. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. These simulations take into account non-uniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields. Comparisons of computations with the experimental measurements are presented, showing reasonably good agreement. The probe survey data and accompanying analysis show that the test flow in the TP3 15-inch nozzle is highly non-uniform at most conditions, and the extent of flow non-uniformity depends on arc current and mass flow rate.

Arc-jets↗

Analysis of Probe Surveys Conducted in the 10-MW TP3 Arc-Jet Facility 15-Inch Nozzle Flow

Computational simulations and analysis of flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center are reported. These tests were conducted in the 10-MW TP3 facility 15-inch conical nozzle, and pitot pressure and heat flux probes are used to survey test flow downstream of the nozzle exit. Two 1.59-cm (0.625 in) diameter hemisphere probes were used: one with a stagnation-point pressure port, the other with a Gardon heat flux gage. Calibration data were also obtained using 20.32-cm flat-faced slug calorimeters. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were obtained at eight arc-heater conditions, covering wide ranges in arc current (316–1756 A) and mass flow rate (32–500 g/s, without any cold-gas injection at the arc-heater plenum) and providing assessment of the flow uniformity in the facility. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. These simulations take into account non-uniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields. Comparisons of computations with the experimental measurements are presented, showing reasonably good agreement. The probe survey data and accompanying analysis show that the test flow in the TP3 15-inch nozzle is highly non-uniform at most conditions, and the extent of flow non-uniformity depends on arc current and mass flow rate.

Arc-jets↗

Cost Scaling of a Real-World Exhaust Waste Heat Recovery Thermoelectric Generator: A Deeper Dive

Cost is equally important to power density or efficiency for the adoption of waste heat recovery thermoelectric generators (TEG) in many transportation and industrial energy recovery applications. In many cases the system design that minimizes cost (e.g., the $/W value) can be very different than the design that maximizes the system's efficiency or power density, and it is important to understand the relationship between those designs to optimize TEG performance-cost compromises. Expanding on recent cost analysis work and using more detailed system modeling, an enhanced cost scaling analysis of a waste heat recovery thermoelectric generator with more detailed, coupled treatment of the heat exchangers has been performed. In this analysis, the effect of the heat lost to the environment and updated relationships between the hot-side and cold-side conductances that maximize power output are considered. This coupled thermal and thermoelectric treatment of the exhaust waste heat recovery thermoelectric generator yields modified cost scaling and design optimization equations, which are now strongly dependent on the heat leakage fraction, exhaust mass flow rate, and heat exchanger effectiveness. This work shows that heat exchanger costs most often dominate the overall TE system costs, that it is extremely difficult to escape this regime, and in order to achieve TE system costs of $1/W it is necessary to achieve heat exchanger costs of $1/(W/K). Minimum TE system costs per watt generally coincide with maximum power points, but Preferred TE Design Regimes are identified where there is little cost penalty for moving into regions of higher efficiency and slightly lower power outputs. These regimes are closely tied to previously-identified low cost design regimes. This work shows that the optimum fill factor Fopt minimizing system costs decreases as heat losses increase, and increases as exhaust mass flow rate and heat exchanger effectiveness increase. These findings have profound implications on the design and operation of various thermoelectric (TE) waste heat 3 recovery systems. This work highlights the importance of heat exchanger costs on the overall TEG system costs, quantifies the possible TEG performance-cost domain space based on heat exchanger effects, and provides a focus for future system research and development efforts.

cost analysis↗