Initial test results for the mini-mast

The objectives of the 20-meter Mini-Mast were: (1) to learn how to efficiently test this type of large truss structure, (2) to relate component testing to the overall behavior of the structure, and (3) to update the associated analytical model based upon the experimental data. The Mini-Mast represents structural characteristics similar to the COFS beam which is planned to be flown on Shuttle to perform on-orbit structures and controls experiments. The information is of interest to LDR because it represents analysis and test information on a truss-type structure which may be similar to the Large Deployable Reflector (LDR) backup structure. The structure has a total of 111 titanium joints; the joint in the center of the truss element is a near-center latch joint. The results of this research indicate that linear deployable-type structures can be built, but difficulties do exist in extracting modes with identical frequencies; gravitational loading does affect the ground test results; and prediction of truss-type-structure dynamic characteristics is not trivial.

Horta, L.↗

Mini-mast dynamic analysis using the truss-beam model

The Mini-Mast is a generic space truss designed by Astro Aerospace Corp. A 210 meter truss located in the Structural Dynamics research Lab of NASA Langley is used in comprehensive active vibration control experiments on a realistic large space structure. Some predictions of the natural frequencies and mode shapes were made based on the Finite Element model. The purpose here is to use the Truss-Beam model developed by Elias G. Abu-Saba to predict the natural frequencies of the Mini-Mast and then compare the results with those obtained from the FE model. Imperfections of the joints are modeled, and joint contribution to the flexibility matrix of the structure is noted. The natural frequencies are obtained. An iterative procedure is used to enhance the Truss-Beam model by comparing these results with experimental ones.

Abu-Saba, Elias G.↗

Failure detection and isolation experiments with the Langley Mini-Mast

A report is presented on experiments to demonstrate failure detection and isolation (FDI) using the flexible truss facility Mini-Mast at the NASA Langley Research Center. Two techniques are selected for study because they are applicable both to sensor and actuator failures and because they do not depend on hypotheses about the forms of possible failures. These two are the method of generalized parity relations and the failure detection filter. These methods utilize the concept of analytical redundancy and therefore their performance depends on the fidelity of the model of the dynamics of the system being monitored. Results are given for sensor FDI using generalized parity relations and input-output data collected during operation of the Mini-Mast. component failures are simulated in the data. The dependence of the performance of the methods on choices of the parameters in their implementation is explored.

Vander Velde, Wallace E.↗

Active structural control design and experiment for the Mini-Mast

Control system design and closed-loop test results for the Mini-Mast truss structure located at the NASA Langley Research Center are presented. The simplicity and effectiveness of a classical control approach to the active structural control design are demonstrated by ground experiments. The concepts of robust nonminimum phase compensation and periodic disturbance rejection are also experimentally validated. The practicality of a sensor output decoupling approach is demonstrated for the inherent, multivariable control problem of the Mini-Mast.

Wie, Bong↗

Flow visualization of mast-mounted-sight/main rotor aerodynamic interactions

Flow visualization tests were conducted on a 27 percent-scale AH-64 attack helicopter model fitted with various mast-mounted-sight configurations in an attempt to identify the cause of adverse vibration encountered during full-scale flight tests of an Apache/Longbow configuration. The tests were conducted at the NASA Langley Research Center in the 14- by 22-Foot Subsonic Tunnel. A symmetric and an asymmetric mast-mounted-sight oriented at several skew angles were tested at forward and rearward flight speeds of 30 and 45 knots. A laser light sheet seeded with vaporized propylene glycol was used to visualize the wake of the sight in planes parallel and perpendicular to the freestream flow. Analysis of the flow visualization data identified the frequency of the wake shed from the sight, the angle-of-attack at the sight, and the location where the sight wake crossed the rotor plane. Differences in wake structure were observed between the various sight configurations and slew angles. Postulations into the cause of the adverse vibration found in flight test are given along with considerations for future tests.

Ghee, Terence A.↗

Atomic oxygen durability evaluation of the flexible batten for the photovoltaic array mast on Space Station

A test program was conducted at the National Aeronautics and Space Administration's Lewis Research Center (LeRC) to evaluate the long term low Earth orbital (LEO) atomic oxygen (AO) durability of a flexible (fiberglass-epoxy composite) batten. The flexible batten is a component used to provide structural rigidity in the photovoltaic array mast on Space Station. The mast is used to support and articulate the photovoltaic array, therefore, the flexible batten must be preloaded for the 15 year lifetime of an array blanket. Development hardware and composite materials were evaluated in ground testing facilities for AO durability and dynamic retraction-deployment cyclic loading representative of expected full life in-space application. The CV1144 silicone (AO protective) coating was determined to provide adequate protection against AO degradation of the composite material and provided fiber containment, thus the structural integrity of the flexible batten was maintained. Both silicone coated and uncoated flexible battens maintained load carrying capabilities. Results of the testing did indicate that the CV1144 silicone protective coating was oxidized by AO reactions to form a brittle glassy (SiO2) skin that formed cracking patterns on all sides of the coated samples. The cracking was observed in samples that were mechanically stressed as well as samples in non-stressed conditions. The oxidized silicon was observed to randomly spall in small localized areas, on the flexible battens that underwent retraction-deployment cycling. Some darkening of the silicon, attributed to vacuum ultraviolet (VUV) radiation, was observed.

Stidham, Curtis R.↗

Variable-Tilt Helicopter Rotor Mast

Variable-tilt helicopter rotor mast proposed to improve helicopter performance and reduce vibration, especially at upper end of forward-speed range of helicopters. Achieved by use of universal coupling in main rotor mast or by tilting entire engine-and-transmission platform. Performance, energy efficiency, and safety enhanced.

Kelley, Henry L.↗

Experimental Analysis of Mast Lifting and Bending Forces on Vibration Patterns Before and After Pinion Reinstallation in an OH-58 Transmission Test Rig

As part of a collaborative research program between NASA Ames Research Center (ARC), NASA Glenn Research Center (GRC), and the US Army Laboratory, a series of experiments is being performed in GRC's 500 HP OH-58 Transmission Test Rig facility and ARC's AH-I Cobra and OH-58c helicopters. The findings reported in this paper were drawn from Phase-I of a two-phase test-rig experiment, and are focused on the vibration response of an undamaged pinion gear operating in the transmission test rig. To simulate actual flight conditions, the transmission system was run at three torque levels, as well as two mast lifting and two mast bending levels. The test rig was also subjected to disassembly and reassembly of the main pinion housing to simulate the effect of maintenance operations. An analysis of variance based on the total power of the spectral distribution indicates the relative effect of each experimental factor, including Wong interactions with torque. Reinstallation of the main pinion assembly is shown to introduce changes in the vibration signature, suggesting the possibility of a strong effect of maintenance on HUMS design and use. Based on these results, further research will be conducted to compare these vibration responses with actual OH58c helicopter transmission vibration patterns.

Huff, Edward M.↗

FAST Mast Structural Response to Axial Loading: Modeling and Verification

The International Space Station s solar array wing mast shadowing problem is the focus of this paper. A building-block approach to modeling and analysis is pursued for the primary structural components of the solar array wing mast structure. Starting with an ANSYS (Registered Trademark) finite element model, a verified MSC.Nastran (Trademark) model is established for a single longeron. This finite element model translation requires the conversion of several modeling and analysis features for the two structural analysis tools to produce comparable results for the single-longeron configuration. The model is then reconciled using test data. The resulting MSC.Nastran (Trademark) model is then extended to a single-bay configuration and verified using single-bay test data. Conversion of the MSC. Nastran (Trademark) single-bay model to Abaqus (Trademark) is also performed to simulate the elastic-plastic longeron buckling response of the single bay prior to folding.

Knight, Norman F., Jr.↗

MAST Propellant and Delivery System Design Methods

A Mars Aerospace Taxi (MAST) concept and propellant storage and delivery case study is undergoing investigation by NASA's Element Design and Architectural Impact (EDAI) design and analysis forum. The MAST lander concept envisions landing with its ascent propellant storage tanks empty and supplying these reusable Mars landers with propellant that is generated and transferred while on the Mars surface. The report provides an overview of the data derived from modeling between different methods of propellant line routing (or "lining") and differentiate the resulting design and operations complexity of fluid and gaseous paths based on a given set of fluid sources and destinations. The EDAI team desires a rough-order-magnitude algorithm for estimating the lining characteristics (i.e., the plumbing mass and complexity) associated different numbers of vehicle propellant sources and destinations. This paper explored the feasibility of preparing a mathematically sound algorithm for this purpose, and offers a method for the EDAI team to implement.

Taxi↗

Towards understanding edge localised mode mitigation by resonant magnetic perturbations in MAST

Type-I Edge Localised Modes (ELMs) have been mitigated in MAST through the application of n=3,4, and 6 resonant magnetic perturbations. For each toroidal mode number of the non-axisymmetric applied fields, the frequency of the ELMs has been increased significantly, and the peak heat flux on the divertor plates reduced commensurately. This increase in ELM frequency occurs despite a significant drop in the edge pressure gradient, which would be expected to stabilise the peeling-ballooning modes thought to be responsible for type-I ELMs. Various mechanisms which could cause a destabilisation of the peeling-ballooning modes are presented, including pedestal widening, plasma rotation braking, three dimensional corrugation of the plasma boundary, and the existence of radially extended lobe structures near to the X-point. This leads to a model aimed at resolving the apparent dichotomy of ELM control, which is to say ELM suppression occurring due to the pedestal pressure reduction below the peeling-ballooning stability boundary, whilst the reduction in pressure can also lead to ELM mitigation, which is ostensibly a destabilisation of peeling-ballooning modes. In the case of ELM mitigation, the pedestal broadening, 3d corrugation, or lobes near the X-point degrade ballooning stability so much that the pedestal recovers rapidly to cross the new stability boundary at lower pressure more frequently, whilst in the case of suppression, the plasma parameters are such that the particle transport reduces the edge pressure below the stability boundary, which is only mildly affected by negligible rotation braking, small edge corrugation or short, broad lobe structures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of fast-ion losses measured in MAST-U via infrared thermography and a Fast Ion Loss Detector

Fast-ion losses need to be monitored to avoid damage to plasma facing components. In existing experimental devices, the scintillator-based fast-ion loss detector (FILD) is the most advanced diagnostic for measuring fast-ion losses. However, FILDs provide only local information about the losses. Infrared (IR) thermography can be used as a complementary tool for more global monitoring of the deposition of fast-ion losses on the wall, at the expense of no velocity-space resolution. IR cameras measure the temperature of the plasma facing components. This measurement, determined by a combined effect of the thermal plasma, radiation, neutrons and fast-ion losses, can be decomposed to infer the fast-ion load on the tokamak wall. In this manuscript, a workflow to estimate fast-ion losses via IR thermography is applied to the MAST-U spherical tokamak, using a 1D approximation to extract the experimental heat flux on the FILD front face from IR data. To numerically estimate the different contributions to this total heat flux, the field-line tracing environment SMITER is used to calculate the thermal plasma contribution, the orbit-following Monte-Carlo code ASCOT to estimate the fast-ion losses, and bolometry measurements for the radiation. To validate the workflow, two discharges, L-mode plasmas with low MHD activity, were executed using on and off-axis beams, respectively. The experimentally and numerically estimated heat flux are of the same order of magnitude for the on-axis heated scenario, with a strong dependence of the estimated fast-ion losses contribution on the fit to the kinetic profiles used as input. This is also true for the off-axis heated scenario, where the total numerically estimated heat flux is 2.1 or 1.3 times higher than the maximum experimentally estimated heat flux, depending on the ASCOT input used.

FILD↗

Calculation of spatial response of 2D beam emission spectroscopy diagnostic on MAST

The beam emission spectroscopy (BES) turbulence diagnostic on MAST is to be upgraded in June 2010 from a one-dimensional trial system to a two-dimensional imaging system (8 radialx4 poloidal channels) based on a newly developed avalanche photodiode array camera. The spatial resolution of the new system is calculated in terms of the point spread function to account for the effects of field-line curvature, observation geometry, the finite lifetime of the excited state of the beam atoms, and beam attenuation and divergence. It is found that the radial spatial resolution is {approx}2-3 cm and the poloidal spatial resolution {approx}1-5 cm depending on the radial viewing location. The absolute number of detected photons is also calculated, hence the photon noise level can be determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A neutron camera system for MAST

A prototype neutron camera has been developed and installed at MAST as part of a feasibility study for a multichord neutron camera system with the aim to measure the spatial and time resolved 2.45 MeV neutron emissivity profile. Liquid scintillators coupled to a fast digitizer are used for neutron/gamma ray digital pulse shape discrimination. The preliminary results obtained clearly show the capability of this diagnostic to measure neutron emissivity profiles with sufficient time resolution to study the effect of fast ion loss and redistribution due to magnetohydrodynamic activity. A minimum time resolution of 2 ms has been achieved with a modest 1.5 MW of neutral beam injection heating with a measured neutron count rate of a few 100 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchronization of Thomson scattering measurements on MAST using an FPGA based ''Smart'' trigger unit

The MAST Thomson scattering diagnostic has recently been upgraded to make electron density and temperature measurements at 130 points across the 1.5 m diameter of the plasma. The new system is able to take 240 measurements per second using eight Nd:YAG lasers, each running at 30 Hz. The exact firing time of these lasers is adjusted with 100 ns precision using a field programmable gate array based trigger unit. Trigger pulses are produced to fire the lamps of all lasers and the Q switches with the appropriate delay depending on the warm-up status. The lasers may be fired in rapid bursts so as to achieve a high temporal resolution over eight points separated down to the microsecond level. This trigger unit receives optical trigger events and signals from external sources, allowing the trigger sequences to be resynchronized to the start of the plasma pulse and further events during the shot such as the entry of a fuelling pellet or randomly occurring plasma events. This resynchronization of the laser firing sequence allows accurate and reproducible measurements of fast plasma phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MAST motional Stark effect diagnostic

A motional Stark effect (MSE) diagnostic is now installed and operating routinely on the MAST spherical tokamak, with 35 radial channels, spatial resolution of {approx}2.5 cm, and time resolution of {approx}1 ms at angular noise levels of {approx}0.5 deg. Conventional (albeit very narrow) interference filters isolate {pi} or {sigma} polarized emission. Avalanche photodiode detectors with digital phase-sensitive detection measure the harmonics of a pair of photoelastic modulators operating at 20 and 23 kHz, and thus the polarization state. The {pi} component is observed to be significantly stronger than {sigma}, in reasonably good agreement with atomic physics calculations, and as a result, almost all channels are now operated on {pi}. Trials with a wide filter that admits the entire Stark pattern (relying on the net polarization of the emission) have demonstrated performance almost as good as the conventional channels. MSE-constrained equilibrium reconstructions can readily be produced between pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam emission spectroscopy turbulence imaging system for the MAST spherical tokamak

A new beam emission spectroscopy turbulence imaging system has recently been installed onto the MAST spherical tokamak. The system utilises a high-throughput, direct coupled imaging optics, and a single large interference filter for collection of the Doppler shifted D{sub {alpha}} emission from the {approx}2 MW heating beam of {approx}70 keV injection energy. The collected light is imaged onto a 2D array detector with 8 x 4 avalanche photodiode sensors which is incorporated into a custom camera unit to perform simultaneous 14-bit digitization at 2 MHz of all 32 channels. The array is imaged at the beam to achieve a spatial resolution of {approx}2 cm in the radial (horizontal) and poloidal (vertical) directions, which is sufficient for detection of the ion-scale plasma turbulence. At the typical photon fluxes of {approx}10{sup 11} s{sup -1} the achieved signal-to-noise ratio of {approx}300 at the 0.5 MHz analogue bandwidth is sufficient for detection of relative density fluctuations at the level of a few 0.1%. The system is to be utilised for the study of the characteristics of the broadband, ion-scale turbulence, in particular its interaction with flow shear, as well as coherent fluctuations due to various types of MHD activity.