Search NASA⌕ Search

SEARCH · Search NASA

Results for “MC&A Program”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Kilovoltage cone-beam CT: Comparative dose and image quality evaluations in partial and full-angle scan protocols

Purpose: To assess imaging dose of partial and full-angle kilovoltage CBCT scan protocols and to evaluate image quality for each protocol. Methods: The authors obtained the CT dose index (CTDI) of the kilovoltage CBCT protocols in an on-board imager by ion chamber (IC) measurements and Monte Carlo (MC) simulations. A total of six new CBCT scan protocols were evaluated: Standard-dose head (100 kVp, 151 mA s, partial-angle), low-dose head (100 kVp, 75 mA s, partial-angle), high-quality head (100 kVp, 754 mA s, partial-angle), pelvis (125 kVp, 706 mA s, full-angle), pelvis spotlight (125 kVp, 752 mA s, partial-angle), and low-dose thorax (110 kVp, 271 mA s, full-angle). Using the point dose method, various CTDI values were calculated by (1) the conventional weighted CTDI (CTDI{sub w}) calculation and (2) Bakalyar's method (CTDI{sub wb}). The MC simulations were performed to obtain the CTDI{sub w} and CTDI{sub wb}, as well as from (3) central slice averaging (CTDI{sub 2D}) and (4) volume averaging (CTDI{sub 3D}) techniques. The CTDI values of the new protocols were compared to those of the old protocols (full-angle CBCT protocols). Image quality of the new protocols was evaluated following the CBCT image quality assurance (QA) protocol [S. Yoo et al., ''A quality assurance program for the on-board imager registered ,'' Med. Phys. 33(11), 4431-4447 (2006)] testing Hounsfield unit (HU) linearity, spatial linearity/resolution, contrast resolution, and HU uniformity. Results: The CTDI{sub w} were found as 6.0, 3.2, 29.0, 25.4, 23.8, and 7.7 mGy for the new protocols, respectively. The CTDI{sub w} and CTDI{sub wb} differed within +3% between IC measurements and MC simulations. Method (2) results were within {+-}12% of method (1). In MC simulations, the CTDI{sub w} and CTDI{sub wb} were comparable to the CTDI{sub 2D} and CTDI{sub 3D} with the differences ranging from -4.3% to 20.6%. The CTDI{sub 3D} were smallest among all the CTDI values. CTDI{sub w} of the new protocols were found as {approx}14 times lower for standard head scan and 1.8 times lower for standard body scan than the old protocols, respectively. In the image quality QA tests, all the protocols except low-dose head and low-dose thorax protocols were within the tolerance in the HU verification test. The HU value for the two protocols was always higher than the nominal value. All the protocols passed the spatial linearity/resolution and HU uniformity tests. In the contrast resolution test, only high-quality head and pelvis scan protocols were within the tolerance. In addition, crescent effect was found in the partial-angle scan protocols. Conclusions: The authors found that CTDI{sub w} of the new CBCT protocols has been significantly reduced compared to the old protocols with acceptable image quality. The CTDI{sub w} values in the point dose method were close to the volume averaging method within 9%-21% for all the CBCT scan protocols. The Bakalyar's method produced more accurate dose estimation within 14%. The HU inaccuracy from low-dose head and low-dose thorax protocols can render incorrect dose results in the treatment planning system. When high soft-tissue contrast data are desired, high-quality head or pelvis scan protocol is recommended depending on the imaging area. The point dose method can be applicable to estimate CBCT dose with reasonable accuracy in the clinical environment.

60 APPLIED LIFE SCIENCES↗

Fundamental Research and Development for Improved Crystalline Silicon Solar Cells: Final Subcontract Report, March 2002 - July 2006

This report summarizes the progress made by Georgia Tech in the 2002-2006 period toward high-efficiency, low-cost crystalline silicon solar cells. This program emphasize fundamental and applied research on commercial substrates and manufacturable technologies. A combination of material characterization, device modeling, technology development, and complete cell fabrication were used to accomplish the goals of this program. This report is divided into five sections that summarize our work on i) PECVD SiN-induced defect passivation (Sections 1 and 2); ii) the effect of material inhomogeneity on the performance of mc-Si solar cells (Section 3); iii) a comparison of light-induced degradation in commercially grown Ga- and B-doped Czochralski Si ingots (Section 4); and iv) the understanding of the formation of high-quality thick-film Ag contacts on high sheet-resistance emitters (Section 5).

14 SOLAR ENERGY↗

XXVIIth International Conference on Supersymmetry and Unification of Fundamental Interactions (SUSY 2019) (Final Report)

Supersymmetry (SUSY) is one of most elegant extensions of the Standard Model (SM) and explains the puzzles of the SM by providing a candidate to explain the dark matter content of the universe, allowing scientists to understand the origin of the electroweak scale requiring the top mass to be around 170 GeV and leading to the unification of forces at a grand unified scale. Further the minimal supersymmetric standard model (MSSM) predicts the Higgs boson mass to be less than 135 GeV. The discovery of the Higgs Boson with mass around 125 GeV at the LHC has provided a major support to SUSY ideas. Searches for SUSY are ongoing at the Large Hadron Collider (LHC). Direct and indirect dark matter experiments are searching for a particle dark matter candidate which arises most naturally in SUSY models. Proton decay predicted by SUSY grand unified theories is being searched for at deep underground experiments. In addition, recent advances in neutrino and dark matter physics, observational astrophysics, precision cosmology and the promising new window into the cosmos opened by the direct detection of gravitational waves, have brought new ideas on the potential connections between new fundamental particles and our understanding of their impact on the early universe and its evolution. At present, the major questions include: Is SUSY still the best candidate for models beyond the SM? Do we have any well motivated alternative to SUSY? Have we exhausted all possibilities to search for new physics at high and low energy scales? XXVIIth International Conference on Supersymmetry and Unification of Fundamental Interactions (SUSY 2019), hosted by Texas A&M University – Corpus Christi during May 20-24, 2019, provided a unique venue to discus and understand the status of SUSY, connection between particle physics and cosmology, supersymmetry and its alternative, Higgs sector, neutrino sector, flavor sector, dark matter, electroweak phase transition, astroparticle physics, gravitational waves and string theory. Discussion of results from the LHC, recent neutrino experiments and observations, direct and indirect dark matter detection experiments, detection of gravitational waves, data from particle colliders, as well as measurements of the CMB and Large Scale Structure were an integral part of SUSY 2019. To ensure the younger participants will benefit from the conference the most, the conference was preceded by the 4 day long pre-SUSY summer school for graduate students and postdocs. The invited speakers were leading scientists in the fields of SUSY interest. The school took place on Texas A&M University – Corpus Christi campus during the week prior the SUSY 2019 conference (May 15 – 18, 2019). Since its inception in 1993, SUSY has become one of the most important and widely attended international meetings in high energy physics, devoted to new ideas in fundamental particle physics. SUSY 2019 brought together approximately 250 scientists, theorists, phenomenologists, experimentalists and cosmologists, (including over 60 graduate students and 70 postdocs) representing 22 nations: Australia, Belgium, Canada, Chile, China, Colombia, France, Germany, India, Italy, Japan, Mexico, Peru, Portugal, Romania, South Korea, Spain, Sweden, Switzerland, Taiwan, United Kingdom and United States. SUSY 2019 provided a stimulating venue for the exchange of scientific ideas among experts in dark matter, neutrino physics, particle physics, astrophysics and cosmology. The following scientific topics were delivered during SUSY 2019 in form of 44 plenary talks and over 200 parallel talks: Unification of Forces; Electroweak, Top and Higgs Physics; Precision Calculations and MC tools; BSM in Flavor Physics; Neutrino Masses: Models and Phenomenology; Cosmology and Gravitational Waves; Dark Matter, Astroparticle Physics; Formal Field Theory and Strings; Alternatives to Supersymmetry; Quantum Information: Machine Learning/Big Data. 28 talks were given during the pre-SUSY program related to the following topics: Neutrino Physics; Big Data; Collider Physics & SUSY; String Phenomenology; Cosmology; Dark Matter; SUSY Models and Phenomenology

43 PARTICLE ACCELERATORS↗

Dynamic Event Tree Analysis Through RAVEN

Conventional Event-Tree (ET) based methodologies are extensively used as tools to perform reliability and safety assessment of complex and critical engineering systems. One of the disadvantages of these methods is that timing/sequencing of events and system dynamics is not explicitly accounted for in the analysis. In order to overcome these limitations several techniques, also know as Dynamic Probabilistic Risk Assessment (D-PRA), have been developed. Monte-Carlo (MC) and Dynamic Event Tree (DET) are two of the most widely used D-PRA methodologies to perform safety assessment of Nuclear Power Plants (NPP). In the past two years, the Idaho National Laboratory (INL) has developed its own tool to perform Dynamic PRA: RAVEN (Reactor Analysis and Virtual control ENvironment). RAVEN has been designed in a high modular and pluggable way in order to enable easy integration of different programming languages (i.e., C++, Python) and coupling with other application including the ones based on the MOOSE framework, developed by INL as well. RAVEN performs two main tasks: 1) control logic driver for the new Thermo-Hydraulic code RELAP-7 and 2) post-processing tool. In the first task, RAVEN acts as a deterministic controller in which the set of control logic laws (user defined) monitors the RELAP-7 simulation and controls the activation of specific systems. Moreover, RAVEN also models stochastic events, such as components failures, and performs uncertainty quantification. Such stochastic modeling is employed by using both MC and DET algorithms. In the second task, RAVEN processes the large amount of data generated by RELAP-7 using data-mining based algorithms. This paper focuses on the first task and shows how it is possible to perform the analysis of dynamic stochastic systems using the newly developed RAVEN DET capability. As an example, the Dynamic PRA analysis, using Dynamic Event Tree, of a simplified pressurized water reactor for a Station Black-Out scenario is presented.

42 ENGINEERING↗

TU-AB-BRC-08: Egs-brachy, a Fast and Versatile Monte Carlo Code for Brachytherapy Applications

Purpose: To introduce egs-brachy, a new, fast, and versatile Monte Carlo code for brachytherapy applications. Methods: egs-brachy is an EGSnrc user-code based on the EGSnrc C++ class library (egs++). Complex phantom, applicator, and source model geometries are built using the egs++ geometry module. egs-brachy uses a tracklength estimator to score collision kerma in voxels. Interaction, spectrum, energy fluence, and phase space scoring are also implemented. Phase space sources and particle recycling may be used to improve simulation efficiency. HDR treatments (e.g. stepping source through dwell positions) can be simulated. Standard brachytherapy seeds, as well as electron and miniature x-ray tube sources are fully modelled. Variance reduction techniques for electron source simulations are implemented (Bremsstrahlung cross section enhancement, uniform Bremsstrahlung splitting, and Russian Roulette). TG-43 parameters of seeds are computed and compared to published values. Example simulations of various treatments are carried out on a single 2.5 GHz Intel Xeon E5-2680 v3 processor core. Results: TG-43 parameters calculated with egs-brachy show excellent agreement with published values. Using a phase space source, 2% average statistical uncertainty in the PTV ((2mm){sup 3} voxels) can be achieved in 10 s for 100 {sup 125}I or {sup 103}Pd seeds in a 36.2 cm{sup 3} prostate PTV, 31 s for 64 {sup 103}Pd seeds in a 64 cm{sup 3} breast PTV, and 56 s for a miniature x-ray tube in a 27 cm{sup 3} breast PTV. Comparable uncertainty is reached in 12 s in a (1 mm){sup 3} water voxel 5 mm away from a COMS 16mm eye plaque with 13 {sup 103}Pd seeds. Conclusion: The accuracy of egs-brachy has been demonstrated through benchmarking calculations. Calculation times are sufficiently fast to allow full MC simulations for routine treatment planning for diverse brachytherapy treatments (LDR, HDR, miniature x-ray tube). egs-brachy will be available as free and open-source software to the medical physics research community. This work is partially funded by the Canada Research Chairs program, the Natural Sciences and Engineering Research Council of Canada, and the Ontario Ministry of Research and Innovation (Ontario Early Researcher Award).

60 APPLIED LIFE SCIENCES↗

Simulation of the Focusing DIRC Optics with Mathematica

The Focusing DIRC is considered for the Barrel PID at a possible Super-B factory. To reduce sensitivity to background, it would be desirable to reduce a size of the present BaBar photon detector. One way to do it is to replace it with a focusing optics and use smaller photon detector pixels. We have simulated the focusing optics with simulation software based on a 3D calculation performed with the Mathematica program. The software does not use Optica package, instead, it uses its own 3D algorithm. The advantage of the presented method is that it is transparent, fast and that it uses a full backing of the Mathematica graphics, and it does not require expertise to run Geat4 MC software.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TH-C-12A-01: Develop a Patient-Specific QA Program for Radiation Therapy with On-Board MRI

Purpose: This work describes development of the first patient-specific quality assurance (QA) program for magnetic resonance imaging guided radiation therapy (MR-IGRT). Methods: The program consisted of following components: 1) multipoint ionization chamber (IC) measurement using a 15 cm3 cubic phantom, 2) 2D stacked radiographic film dosimetry using a 30×30×20 cm3 phantom with multiple inserted ICs, 3) 3D ArcCHECK measurement with a centrally inserted IC, 4) machine delivery file verification, 5) 3D Monte-Carlo dose re-calculation with machine delivery file and phantom CT, 6) 2-head mode delivery validation in case of a malfunctioning head, and 7) independent beam-on time calculation for non-IMRT fields. Both ADCL calibrated ICs and ArcCHECK were MRI compatible. Experimental data were analyzed for the first 10 patients treated at our institution. Results: The customized phantoms allowed measuring multiple points with ICs in one delivery. Absolute IC measurements were all within 3% in all phantom geometry/shape/material combinations. Despite known uncertainty associated with film dosimetry, passing rates greater than 90% were achieved in both absolute and composite modes using TG-129 criteria. Due to the simultaneous irradiation by three radiation sources, ArcCHECK was used as a 3D relative dosimeter with angular and energy dependences uncorrected. 95–100% passing rates were obtained and the centrally inserted IC measurement assured that the overall dose normalization was within 3%. Machine delivery file verification and MC recalculated dose to the phantom results showed 98–100% passing rates, providing opportunity of moving from gamma passing rates to patient DVHbased QA metrics. Same results were obtained for the 2-head delivery mode. Manual beam-on time calculation for non-IMRT fields showed better than 5% agreement. Conclusion: We have successfully developed the first MRIGRT patient specific QA program by adopting experimental and computational dosimetry methods that were developed in the past decade for other radiation therapy modalities.

60 APPLIED LIFE SCIENCES↗

Variance reduction via simultaneous importance sampling and control variates techniques using vegas

Monte Carlo (MC) integration is an important calculational technique in the physical sciences. Practical considerations require that the calculations are performed as accurately as possible for a given set of computational resources. To improve the accuracy of MC integration, a number of useful variance reduction algorithms have been developed, including importance sampling and control variates. In this work, we demonstrate how these two methods can be applied simultaneously, thus combining their benefits. We provide a python wrapper, named CoVVVR, which implements our approach in the VEGAS program. The improvements are quantified with several benchmark examples from the literature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Codebase release r1.4 for CoVVVR

Monte Carlo (MC) integration is an important calculational technique in the physical sciences. Practical considerations require that the calculations are performed as accurately as possible for a given set of computational resources. To improve the accuracy of MC integration, a number of useful variance reduction algorithms have been developed, including importance sampling and control variates. In this work, we demonstrate how these two methods can be applied simultaneously, thus combining their benefits. We provide a python wrapper, named COVVVR, which implements our approach in the VEGAS program. The improvements are quantified with several benchmark examples from the literature.

Shyamsundar, Prasanth↗

Impact of Spontaneous Fission Neutron Emission Energy on Neutron Detector Response

A parametric study was simulated in MCNP to investigate the impact of spontaneous fission neutron energy on neutron detector response. A total of 880 configurations were simulated by varying 3 He pressure and polyethylene reflector thickness for 8 different isotopes. Results showed that deviations between the simulated isotopes become more prevalent at higher energies with 238 U showing the greatest deviation. It was also observed that configurations comparable to most detection setups, 10 atm and 6 - 8 cm polyethylene, were closer to the upper bound of deviations from a 252 Cf. 240 Pu, a common spontaneous fission source of interest, ranged from 2% - 3% within this space. This suggests that further investigation is required to determine exact correction factors when calibrating neutron detectors with a 252 Cf. Although demonstrated here for a 4π-detection system, future plans include simulating a more detailed model of the MC-15 detection setup to determine exact correction factors for future experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Celeritas: GPU-accelerated particle transport for detector simulation in High Energy Physics experiments

Within the next decade, experimental High Energy Physics (HEP) will enter a new era of scientific discovery through a set of targeted programs recommended by the Particle Physics Project Prioritization Panel (P5), including the upcoming High Luminosity Large Hadron Collider (LHC) HL-LHC upgrade and the Deep Underground Neutrino Experiment (DUNE). These efforts in the Energy and Intensity Frontiers will require an unprecedented amount of computational capacity on many fronts including Monte Carlo (MC) detector simulation. In order to alleviate this impending computational bottleneck, the Celeritas MC particle transport code is designed to leverage the new generation of heterogeneous computer architectures, including the exascale computing power of U.S. Department of Energy (DOE) Leadership Computing Facilities (LCFs), to model targeted HEP detector problems at the full fidelity of Geant4. This paper presents the planned roadmap for Celeritas, including its proposed code architecture, physics capabilities, and strategies for integrating it with existing and future experimental HEP computing workflows.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recommendations for a Fundamental Nuclear Material Control (FNMC) Plan for TRISO Fuel Fabrication Facilities Under NRC Regulations

A fundamental nuclear material control (FNMC) plan, which is required for all fuel fabrication facilities that are authorized to possess more than 1 effective kg of special nuclear material, describes how material control and accounting (MC&A) requirements will be met to comply with US Nuclear Regulatory Commission (NRC) regulations. Tristructural isotropic (TRISO) fuel fabrication facilities are likely to have issues in meeting MC&A requirements because of the new processes and fuel types their work involves. This report provides recommendations for an FNMC plan specifically for a TRISO fuel fabrication facility under NRC regulations and includes a draft outline of an FNMC plan. This report was produced for the Materials Protection, Accounting, and Control Technologies (MPACT) program under the Nuclear Fuel Cycle Technologies programs within the US Department of Energy’s Office of Nuclear Energy.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Final Technical Report

The capture of CO2 and its simultaneously conversion to useful chemical fuels driven by solar energy represents one of the best solutions to resolve our growing energy and environmental concerns. The most critical challenge to this endeavor is the rational design of a photocatalytic architecture that can effectively couple a given photosensitizer (PS) with an appropriate catalyst, thereby enabling efficient photosensitization of a multi-electron reduction catalysis. This research program aims to address this challenge using an interdisciplinary approach that combines innovative material design and synthesis, fundamental mechanistic studies, and photocatalytic performance evaluation. The strategies include 1) constructing and investigating a novel class of 2D COF hybrid photocatalysts with an effective photoactive organic building block as PS and a precisely incorporated CO2 reduction molecular catalyst (MC); and 2) mechanistic origins of CO2 photoreduction using a set of complementary time-resolved and in situ spectroscopic techniques. The novelty of the proposed hybrid system lies in the unprecedented combination of the unique advantage of porous crystalline COF PS with the precise catalytic function of MC for photocatalytic CO2 reduction. In the periods of the support (09/01/2019-12/31/2022), we have made research progress in four projects: 1) Exploring 2D COFs with incorporated Mn complex for light driven CO2 reduction; 2) The dependence of excited state and charge transfer dynamics on monomer structure of 2D COFs; and 3) Control over Charge Separation by Imine Structural Isomerization in Covalent Organic Frameworks with Implications on CO2 Photoreduction; and 4) The impact of monomer structure on the photoluminescence properties of COFs. We found that both monomer structure and linker chemistry can effectively impact the excited state dynamics, charge transfer properties, and photoluminescence quantum yields, the important properties that dictate their applications in photocatalysis. In addition, we found that the direction of imine linker determines charge transfer direction and thus controls the types of catalytic reactions (e.g. water oxidation or CO2 reduction reactions). The result from these fundamental studies provides important information for correlating the structure of the COF photocatalysts with their photophysical properties and catalytic functions, paving the way for their novel application in photocatalysis. We expect that our findings will contribute to addressing current shortcomings of semiconductor- and molecular-based photocatalytic systems that suffer from inefficient light harvesting and charge separation and poor adsorption and activation of reactants. In turn, this research will contribute towards the development of novel photocatalytic systems for CO2 reduction to generate renewable chemical fuels and simultaneously address the problem of mitigating climate change due to CO2 accumulation. In addition, the experimental approaches employed in this research can be easily transferred to other energy technologies and are expected to broadly impact fields involving photocatalysis, optoelectronic devices, and solar energy conversion. The proposed research has also been integrated with educational activities and serve as a basis to raise awareness around the critical issues of global energy production and consumption, and to develop the next generation of solar energy scientists.

14 SOLAR ENERGY↗

FY22 Proxy App Suite Release

The FY22 Proxy App Suite Release milestone includes the following activities: Curate a collection of proxy applications that represents the breadth of ECP applications, including application domains, programming models, supporting libraries, numerical methods, etc. Identify gaps in coverage and work with application teams to commission or develop proxies to cover gaps. From within this collection, designate the ”ECP Proxy Application Suite” of 10–15 proxies that balance breadth of coverage with ease of use and quality of implementation. Also designate approximately 6–10 proxies to form the “ECP Machine Learning Proxy Suite”. The ML suite will represent algorithms, use cases, and programming methods typically used by ECP science workloads to incorporate machine learning into their workflows.

97 MATHEMATICS AND COMPUTING↗

Safeguards and security by design (SSBD) for the domestic threat - theft and sabotage

Safeguards by Design (SBD) is receiving significant interest with respect to international safeguards objectives. However, less attention has been focused on the equally important topic of domestic Safeguards and Security by Design (SSBD), which addresses requirements such as those of the Nuclear Regulatory Commission (NRC) in the United States. While international safeguards are concerned with detecting State diversion of nuclear material from peaceful to nuclear explosives purposes, domestic Material Protection, Control and Accounting measures (MPC&A) are focused on non-State theft and sabotage. The International Atomic Energy Agency (IAEA) has described the Safeguards by Design (SBD) concept as an approach in which 'international safeguards are fully integrated into the design process of a new nuclear facility from the initial planning through design, construction, operation, and decommissioning.' This same concept is equally applicable to SSBD for domestic requirements. The United States Department of Energy (DOE) has initiated a project through its Office of Nuclear Energy (NE) and more specifically its Fuel Cycle Research and Development (FCRD) program, to develop a domestic SSBD discipline and methodology in parallel with similar efforts sponsored by the DOE Next Generation Safeguards Initiative (NGSI) and the IAEA for international safeguards. This activity includes the participation of industry (through DOE-sponsored contracts) and DOE National Laboratories. This paper will identify the key domestic safeguards and security requirements (i.e. MC&A and physical protection) and explain how and why Safeguards and Security by Design (SSBD) is important and beneficial for the design of future US nuclear energy systems.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

SU-F-BRA-11: An Experimental Commissioning Test of Brachytherapy MBDCA Dosimetry, Based On a Commercial Radiochromic Gel/optical CT System

Purpose: To implement a 3D dose verification procedure of Model-Based Dose Calculation Algorithms (MBDCAs) for {sup 192}Ir HDR brachytherapy, based on a novel Ferrous Xylenol-orange gel (FXG) and optical CT read-out. Methods: The TruView gel was employed for absolute dosimetry in conjunction with cone-beam optical CT read-out with the VISTA scanner (both from Modus Medical Inc, London, ON, Canada). A multi-catheter skin flap was attached to a cylindrical PETE jar (d=9.6cm, h=16cm) filled with FXG, which served as both the dosimeter and the water equivalent phantom of bounded dimensions. X- ray CT image series of the jar with flap attached was imported to Oncentra Brachy v.4.5. A treatment plan consisting of 8 catheters and 56 dwell positions was generated, and Oncentra-ACE MBDCA as well as TG43 dose results were exported for further evaluation. The irradiation was carried out with a microSelecton v2 source. The FXG dose-response, measured via an electron irradiation of a second dosimeter from the same batch, was linear (R2>0.999) at least up to 12Gy. A MCNP6 input file was prepared from the DICOM-RT plan data using BrachyGuide to facilitate Monte Carlo (MC) simulation dosimetry in the actual experimental geometry. Agreement between experimental (reference) and calculated dose distributions was evaluated using the 3D gamma index (GI) method with criteria (5%-2mm applied locally) determined from uncertainty analysis. Results: The TG-43 GI failed, as expected, in the majority of voxels away from the flap (pass rate 59% for D>0.8Gy, corresponding to 10% of prescribed dose). ACE performed significantly better (corresponding pass rate 92%). The GI evaluation for the MC data (corresponding pass rate 97%) failed mainly at low dose points of increased uncertainty. Conclusion: FXG gel/optical CT is an efficient method for level-2 commissioning of brachytherapy MBDCAs. Target dosimetry is not affected from uncertainty introduced by TG43 assumptions in 192Ir skin brachytherapy. Research co-financed by the ESF and Greek funds through the Operational Program Education and Lifelong Learning Investing in Knowledge Society of the NSRF. Research Funding Program: Aristeia. Modus Medical Devices Inc. provided a TruView dosimeter batch and Nucletron, and Elekta company, provided access to Oncentra Brachy v4.5, for research purposes.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP1-06: Fast GPU Framework for Four-Dimensional Monte Carlo in Adaptive Intensity Modulated Proton Therapy (IMPT) for Mobile Tumors

Purpose: To demonstrate the feasibility of fast Monte Carlo (MC) treatment planning and verification using four-dimensional CT (4DCT) for adaptive IMPT for lung cancer patients. Methods: A validated GPU MC code, gPMC, has been linked to the patient database at our institution and employed to compute the dose-influence matrices (Dij) on the planning CT (pCT). The pCT is an average of the respiratory motion of the patient. The Dijs and patient structures were fed to the optimizer to calculate a treatment plan. To validate the plan against motion, a 4D dose distribution averaged over the possible starting phases is calculated using the 4DCT and a model of the time structure of the delivered spot map. The dose is accumulated using vector maps created by a GPU-accelerated deformable image registration program (DIR) from each phase of the 4DCT to the reference phase using the B-spline method. Calculation of the Dij matrices and the DIR are performed on a cluster, with each field and vector map calculated in parallel. Results: The Dij production takes ∼3.5s per beamlet for 10e6 protons, depending on the energy and the CT size. Generating a plan with 4D simulation of 1000 spots in 4 fields takes approximately 1h. To test the framework, IMPT plans for 10 lung cancer patients were generated for validation. Differences between the planned and the delivered dose of 19% in dose to some organs at risk and 1.4/21.1% in target mean dose/homogeneity with respect to the plan were observed, suggesting potential for improvement if adaptation is considered. Conclusion: A fast MC treatment planning framework has been developed that allows reliable plan design and verification for mobile targets and adaptation of treatment plans. This will significantly impact treatments for lung tumors, as 4D-MC dose calculations can now become part of planning strategies.

60 APPLIED LIFE SCIENCES↗

Predictive performance of multi-model ensemble forecasts of COVID-19 across European nations

Background: Short-term forecasts of infectious disease burden can contribute to situational awareness and aid capacity planning. Based on best practice in other fields and recent insights in infectious disease epidemiology, one can maximise the predictive performance of such forecasts if multiple models are combined into an ensemble. Here, we report on the performance of ensembles in predicting COVID-19 cases and deaths across Europe between 08 March 2021 and 07 March 2022. Methods: We used open-source tools to develop a public European COVID-19 Forecast Hub. We invited groups globally to contribute weekly forecasts for COVID-19 cases and deaths reported by a standardised source for 32 countries over the next 1–4 weeks. Teams submitted forecasts from March 2021 using standardised quantiles of the predictive distribution. Each week we created an ensemble forecast, where each predictive quantile was calculated as the equally-weighted average (initially the mean and then from 26th July the median) of all individual models’ predictive quantiles. We measured the performance of each model using the relative Weighted Interval Score (WIS), comparing models’ forecast accuracy relative to all other models. We retrospectively explored alternative methods for ensemble forecasts, including weighted averages based on models’ past predictive performance. Results: Over 52 weeks, we collected forecasts from 48 unique models. We evaluated 29 models’ forecast scores in comparison to the ensemble model. We found a weekly ensemble had a consistently strong performance across countries over time. Across all horizons and locations, the ensemble performed better on relative WIS than 83% of participating models’ forecasts of incident cases (with a total N=886 predictions from 23 unique models), and 91% of participating models’ forecasts of deaths (N=763 predictions from 20 models). Across a 1–4 week time horizon, ensemble performance declined with longer forecast periods when forecasting cases, but remained stable over 4 weeks for incident death forecasts. In every forecast across 32 countries, the ensemble outperformed most contributing models when forecasting either cases or deaths, frequently outperforming all of its individual component models. Among several choices of ensemble methods we found that the most influential and best choice was to use a median average of models instead of using the mean, regardless of methods of weighting component forecast models. Conclusions: Our results support the use of combining forecasts from individual models into an ensemble in order to improve predictive performance across epidemiological targets and populations during infectious disease epidemics. Our findings further suggest that median ensemble methods yield better predictive performance more than ones based on means. Our findings also highlight that forecast consumers should place more weight on incident death forecasts than incident case forecasts at forecast horizons greater than 2 weeks. Funding: AA, BH, BL, LWa, MMa, PP, SV funded by National Institutes of Health (NIH) Grant 1R01GM109718, NSF BIG DATA Grant IIS-1633028, NSF Grant No.: OAC-1916805, NSF Expeditions in Computing Grant CCF-1918656, CCF-1917819, NSF RAPID CNS-2028004, NSF RAPID OAC-2027541, US Centers for Disease Control and Prevention 75D30119C05935, a grant from Google, University of Virginia Strategic Investment Fund award number SIF160, Defense Threat Reduction Agency (DTRA) under Contract No. HDTRA1-19-D-0007, and respectively Virginia Dept of Health Grant VDH-21-501-0141, VDH-21-501-0143, VDH-21-501-0147, VDH-21-501-0145, VDH-21-501-0146, VDH-21-501-0142, VDH-21-501-0148. AF, AMa, GL funded by SMIGE - Modelli statistici inferenziali per governare l'epidemia, FISR 2020-Covid-19 I Fase, FISR2020IP-00156, Codice Progetto: PRJ-0695. AM, BK, FD, FR, JK, JN, JZ, KN, MG, MR, MS, RB funded by Ministry of Science and Higher Education of Poland with grant 28/WFSN/2021 to the University of Warsaw. BRe, CPe, JLAz funded by Ministerio de Sanidad/ISCIII. BT, PG funded by PERISCOPE European H2020 project, contract number 101016233. CP, DL, EA, MC, SA funded by European Commission - Directorate-General for Communications Networks, Content and Technology through the contract LC-01485746, and Ministerio de Ciencia, Innovacion y Universidades and FEDER, with the project PGC2018-095456-B-I00. DE., MGu funded by Spanish Ministry of Health / REACT-UE (FEDER). DO, GF, IMi, LC funded by Laboratory Directed Research and Development program of Los Alamos National Laboratory (LANL) under project number 20200700ER. DS, ELR, GG, NGR, NW, YW funded by National Institutes of General Medical Sciences (R35GM119582; the content is solely the responsibility of the authors and does not necessarily represent the official views of NIGMS or the National Institutes of Health). FB, FP funded by InPresa, Lombardy Region, Italy. HG, KS funded by European Centre for Disease Prevention and Control. IV funded by Agencia de Qualitat i Avaluacio Sanitaries de Catalunya (AQuAS) through contract 2021-021OE. JDe, SMo, VP funded by Netzwerk Universitatsmedizin (NUM) project egePan (01KX2021). JPB, SH, TH funded by Federal Ministry of Education and Research (BMBF; grant 05M18SIA). KH, MSc, YKh funded by Project SaxoCOV, funded by the German Free State of Saxony. Presentation of data, model results and simulations also funded by the NFDI4Health Task Force COVID-19 ( https://www.nfdi4health.de/task-force-covid-19-2 ) within the framework of a DFG-project (LO-342/17-1). LP, VE funded by Mathematical and Statistical modelling project (MUNI/A/1615/2020), Online platform for real-time monitoring, analysis and management of epidemic situations (MUNI/11/02202001/2020); VE also supported by RECETOX research infrastructure (Ministry of Education, Youth and Sports of the Czech Republic: LM2018121), the CETOCOEN EXCELLENCE (CZ.02.1.01/0.0/0.0/17-043/0009632), RECETOX RI project (CZ.02.1.01/0.0/0.0/16-013/0001761). NIB funded by Health Protection Research Unit (grant code NIHR200908). SAb, SF funded by Wellcome Trust (210758/Z/18/Z).

60 APPLIED LIFE SCIENCES↗