Search NASA⌕ Search

SEARCH · Search NASA

Results for “MCP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Assessing Long-Term Wind Conditions by Combining Different Measure-Correlate-Predict Algorithms: Preprint

This paper significantly advances the hybrid measure-correlate-predict (MCP) methodology, enabling it to account for variations of both wind speed and direction. The advanced hybrid MCP method uses the recorded data of multiple reference stations to estimate the long-term wind condition at a target wind plant site. The results show that the accuracy of the hybrid MCP method is highly sensitive to the combination of the individual MCP algorithms and reference stations. It was also found that the best combination of MCP algorithms varies based on the length of the correlation period.

17 WIND ENERGY↗

Photon-counting detector arrays based on microchannel array plates

The recent development of the channel electron multiplier (CEM) and its miniaturization into the microchannel array plate (MCP) offers the possibility of fully combining the advantages of the photographic and photoelectric detection systems. The MCP has an image-intensifying capability and the potential of being developed to yield signal outputs superior to those of conventional photomultipliers. In particular, the MCP has a photon-counting capability with a negligible dark-count rate. Furthermore, the MCP can operate stably and efficiently at extreme-ultraviolet and soft X-ray wavelengths in a windowless configuration or can be integrated with a photo-cathode in a sealed tube for use at ultraviolet and visible wavelengths. The operation of one- and two-dimensional photon-counting detector arrays based on the MCP at extreme-ultraviolet wavelengths is described, and the design of sealed arrays for use at ultraviolet and visible wavelengths is briefly discussed.

Timothy, J. G.↗

Power assist EVA glove development

Structural modeling of the EVA glove indicates that flexibility in the metacarpophalangeal (MCP) joint can be improved by selectively lowering the elasticity of the glove fabric. Two strategies are used to accomplish this. One method uses coil springs on the back of the glove to carry the tension in the glove skin due to pressurization. These springs carry the loads normally borne by the glove fabric, but are more easily deformed. An active system was also designed for the same purpose and uses gas filled bladders attached to the back of the EVA glove that change the dimensions of the back of the glove and allow the glove to bend at the MCP joint, thus providing greater flexibility at this joint. A threshold control scheme was devised to control the action of the joint actuators. Input to the controller was provided by thin resistive pressure sensors placed between the hand and the pressurized glove. The pressure sensors consist of a layer of polyester film that has a thin layer of ink screened on the surface. The resistivity of the ink is pressure dependent, so an extremely thin pressure sensor can be fabricated by covering the ink patch with another layer of polyester film and measuring the changing resistance of the ink with a bridge circuit. In order to sense the force between the hand and the glove at the MCP joint, a sensor was placed on the palmar face of the middle finger. The resultant signal was used by the controller to decide whether to fill or exhaust the bladder actuators on the back of the glove. The information from the sensor can also be used to evaluate the effectiveness of a given control scheme or glove design since the magnitude of the measured pressures gives some idea of the torque required to bend a glove finger at the MCP joint. Tests of this actuator, sensor, and control system were conducted in an 57.2 kPa glove box by performing a series of 90 degree finger bends with a glove without an MCP joint assembly, a glove with the coil spring assembly, and with the four fingered actuated glove. The tests of these three glove designs confirm the validity of the model.

Main, John A.↗

Development of high resolution imaging detectors for x ray astronomy

This final report summarizes our past activities and discusses the work performed over the period of 1 April 1990 through 1 April 1991 on x-ray optics, soft x-ray (0.1 - 10 KeV) imaging detectors, and hard x-ray (10 - 300 KeV) imaging detectors. If microchannel plates (MCPs) can be used to focus x-rays with a high efficiency and good angular resolution, they will revolutionize the field of x-ray optics. An x-ray image of a point source through an array of square MCP pores compared favorably with our ray tracing model for the MCP. Initial analysis of this image demonstrates the feasibility of MCPs for soft x-rays. Our work continues with optimizing the performance of our soft x-ray MCP imaging detectors. This work involves readout technology that should provide improved MCP readout devices (thin film crossed grid, curved, and resistive sheets), defect removal in MCPs, and photocathode optimization. In the area of hard x-ray detector development we have developed two different techniques for producing a CsI photocathode thickness of 10 to 100 microns, such that it is thick enough to absorb the high energy x-rays and still allow the photoelectrons to escape to the top MCP of a modified soft x-ray imaging detector. The methods involve vacuum depositing a thick film of CsI on a strong back, and producing a converter device that takes the place of the photocathode.

Murray, S. S.↗

Compression under a mechanical counter pressure space suit glove

Background: Current gas-pressurized space suits are bulky stiff shells severely limiting astronaut function and capability. A mechanical counter pressure (MCP) space suit in the form of a tight elastic garment could dramatically improve extravehicular activity (EVA) dexterity, but also be advantageous in safety, cost, mass and volume. The purpose of this study was to verify that a prototype MCP glove exerts the design compression of 200 mmHg, a pressure similar to the current NASA EVA suit. Methods: Seven male subjects donned a pressure measurement array and MCP glove on the right hand, which was placed into a partial vacuum chamber. Average compression was recorded on the palm, the bottom of the middle finger, the top of the middle finger and the dorsum of the hand at pressures of 760 (ambient), 660 and 580 mmHg. The vacuum chamber was used to simulate the pressure difference between the low breathing pressure of the current NASA space suits (approximately 200 mmHg) and an unprotected hand in space. Results: At ambient conditions, the MCP glove compressed the dorsum of the hand at 203.5 +/- 22.7 mmHg, the bottom of the middle finger at 179.4 +/- 16.0 mmHg, and the top of the middle finger at 183.8 +/- 22.6 mmHg. The palm compression was significantly lower (59.6 +/- 18.8 mmHg, p<0.001). There was no significant change in glove compression with the chamber pressure reductions. Conclusions: The MCP glove compressed the dorsum of the hand and middle finger at the design pressure.

NASA Discipline Life Sciences Technologies↗

Study of Static Microchannel Plate Saturation Effects for the Fast Plasma Investigation Dual Electron Spectrometers on NASA's Magnetospheric MultiScale Mission

Imaging detecting systems based on microchannel plates (MCPs) are the most common for low energy plasma measurements for both space borne and ground applications. One of the key parameters of these detection systems is the dynamic range of the MCP's response to the input fluxes of charged particles. For most applications the dynamic range of the linear response should be as wide as possible. This is especially true for the Dual Electron Spectrometers (DESs) of the Fast Plasma Investigation (FPI) on NASA's Magnetospheric MultiScale (MMS) mission because a wide range of input fluxes are expected. To make use of the full available dynamic range, it is important to understand the MCP response behavior beyond the linear regime where the MCPs start to saturate. We have performed extensive studies of this during the characterization and calibration of the DES instruments and have identified several saturation effects of the detection system. The MCP itself exhibits saturation when the channels lack the ability to replenish charge sufficiently rapidly. It is found and will be shown that the ground system can significantly impact the correct measurement of this effect. As the MCP starts to saturate, the resulting pulse height distribution (PHD) changes shape and location (with less pulse height values), which leads to truncation of the PHD by the threshold set on the detection system discriminator. Finally, the detection system pulse amplifier exhibits saturation as the input flux drives pulse rates greater than its linear response speed. All of these effects effectively change the dead time of the overall detection system and as a result can affect the quality and interpretation of the flight data. We present results of detection system saturation effects and their interaction with special emphasis on the MCP related effects.

detecting system↗

The "Space Activity Suit" - A Historical Perspective and A Primer on the Physiology of Mechanical Counter-Pressure

Since the 1950s, mechanical counter-pressure (MCP) has been investigated as a possible alternative design concept to traditional extra-vehicular activity (EVA) space suits. While traditional gas-pressurized EVA suits provide physiological protection against the ambient vacuum by means of pressurized oxygen to at least 3.1 pounds per square inch absolute (160 millimeters of mercury), MCP provides protection by direct application of pressure on the skin by a fabric. In reviewing the concept, MCP offers distinct potential advantages to traditional EVA suits: lower mass, reduced consumables, increased mobility, increased comfort, less complexity, and improved failure modes. In the mid 1960s to early 1970s, Dr. Paul Webb of Webb Associates developed and tested such a suit under funding from NASA Langley Research Center. This "Space Activity Suit" (SAS) was improved many times while testing in the laboratory and an altitude chamber to as low as 0.3 pounds per square inch absolute (15 millimeters of mercury). This testing, and the reports by Webb documenting it, are often presented as evidence of the feasibility of MCP. In addition, the SAS reports contain a wealth of information regarding the physiological requirements to make MCP work at the time, which is still accurate today. This paper serves to document the Space Activity Suit effort and analyze it in today's context.

McFarland, Shane M.↗

Mechanical Counter-Pressure EVA Suits: NASA Outlook and Development Strategy

Since the 1950s, mechanical counter-pressure (MCP) has been investigated as a possible alternative architecture to traditional extra-vehicular activity (EVA) suits. While traditional gas-pressurized EVA suits provide physiological protection against the ambient vacuum environment by means of pressurized oxygen to at least 3.1 psid, MCP provides protection by direct application of pressure on the skin by a fabric. In reviewing the concept, MCP offers distinct potential advantages to traditional EVA suits: lower mass, reduced consumables, increased mobility, increased comfort, less complexity, and improved failure modes. In addition, as basic feasibility was established in the 1960s with the successful testing of the Space Activity Suit, MCP seems poised to inevitably supplant traditional EVA architectures with a modest degree of concentrated development. However, as they say, "The devil is in the details". This paper serves as a comprehensive summary of the technical work that has been completed related to MCP from 1960 to 2019, the technical gaps that need to be closed to facilitate a flight-capable design, and outlines an overall development strategy that NASA feels would best address these gaps moving forward.

mechanical counter-pressure↗

Data-Based Modeling of MMS/FPI Microchannel Plate Detector Resistance Using Temperature Proxy

The Magnetospheric MultiScale (MMS) space physics mission studies magnetic reconnection in the Earth’s magnetosphere. This work presents the results of an analysis of the resistance of the microchannel plates (MCP) included in the particle spectrometers, which are components of the Fast Plasma Investigation (FPI) aboard each MMS spacecraft. We found that a proxy for the resistance of the MCPs can be estimated from the MCP bias voltage and MCP high voltage power supply (HVPS) temperature. This estimation of MCP resistance allows for an accurate determination of nominal MCP current.

Joseph Patton↗

Cosmic millicharge background and reheating probes

We demonstrate that the searches for dark sector particles can provide probes of reheating scenarios, focusing on the cosmic millicharge background produced in the early universe. We discuss two types of millicharge particles (mCPs): either with, or without, an accompanying dark photon. These two types of mCPs have distinct theoretical motivations and cosmological signatures. We discuss constraints from the overproduction and mCP-baryon interactions of the mCP without an accompanying dark photon, with different reheating temperatures. We also consider the ∆n eff constraints on the mCPs from kinetic mixing, varying the reheating temperature. The regions of interest in which the accelerator and other experiments can probe the reheating scenarios are identified in this paper for both scenarios. These probes can potentially allow us to set an upper bound on the reheating temperature down to ~ 10 MeV, much lower than the previously considered upper bound from inflationary cosmology at around ~ 10 16 GeV. In addition, we derive a new “distinguishability condition”, in which the two mCP scenarios may be differentiated by combining cosmological and theoretical considerations. Finally, we discuss the implications of dedicated mCP searches, future CMB-S4 observations, and the target for experiments when considering the minimally allowed reheating temperature.

79 ASTRONOMY AND ASTROPHYSICS↗

Multichannel filter application of a magnetized cold plasma defect in periodic structure of ZnS/TiO{sub 2} materials

In this article, transmission spectra of multilayer structure of zinc sulfide (ZnS) and titanium dioxide (TiO{sub 2}) with defect of magnetized cold plasma (MCP) have been calculated theoretically by using characteristics transfer matrix method. The transmission spectra versus frequency have been analyzed for symmetric and asymmetric structure. Due to have a multiple band gaps in the asymmetric structure, we have taken the asymmetric structure for analysis with the parameters of MCP and the thicknesses of the dielectric materials. It is well known that magnetized cold plasma is an abnormal material because the permittivity changes with applied external magnetic field, and shows tunable photonic band gap for permittivity of the MCP. Now, the transmission spectra of the asymmetric structure versus frequency by inserting one or two magnetized cold plasma layer were analyzed with the variation of incident angles, the parameters of MCP, and the thicknesses of ZnS and TiO{sub 2} material. The analyzed transmission spectra of asymmetric structure with the variation of electron density, thicknesses of dielectric materials were obtained better results with defect of two plasma layers as compare to the defect of one layer of plasma. These obtained results reveal that the defect of two magnetized cold plasma layers of one dimensional asymmetric structure of ZnS, TiO{sub 2} may be used for the tunable multichannel filter at microwave region.

36 MATERIALS SCIENCE↗

Suppression of lipin-1 expression increases monocyte chemoattractant protein-1 expression in 3T3-L1 adipocytes

Highlights: Black-Right-Pointing-Pointer Lipin-1 affects lipid metabolism, adipocyte differentiation, and transcription. Black-Right-Pointing-Pointer Adipose lipin-1 expression is reduced in obesity. Black-Right-Pointing-Pointer Lipin-1 depletion using siRNA in 3T3-L1 adipocytes increased MCP-1 expression. Black-Right-Pointing-Pointer Lipin-1 is involved in adipose inflammation. -- Abstract: Lipin-1 plays a crucial role in the regulation of lipid metabolism and cell differentiation in adipocytes. Expression of adipose lipin-1 is reduced in obesity, and metabolic syndrome. However, the significance of this reduction remains unclear. This study investigated if and how reduced lipin-1 expression affected metabolism. We assessed mRNA expression levels of various genes related to adipocyte metabolism in lipin-1-depleted 3T3-L1 adipocytes by introducing its specific small interfering RNA. In lipin-1-depleted adipocytes, mRNA and protein expression levels of monocyte chemoattractant protein-1 (MCP-1) were significantly increased, although the other genes tested were not altered. The conditioned media from the cells promoted monocyte chemotaxis. The increase in MCP-1 expression was prevented by treatment with quinazoline or salicylate, inhibitors of nuclear factor-{kappa}B activation. Because MCP-1 is related to adipose inflammation and systemic insulin resistance, these results suggest that a reduction in adipose lipin-1 in obesity may exacerbate adipose inflammation and metabolism.

60 APPLIED LIFE SCIENCES↗

Oxidation chemistry of cyclic hydrocarbons in a motored engine: Methylcyclopentane, tetralin, and decalin

This work, which parallels a recent study of cyclohexane and methylcyclohexane by the authors, concerns the oxidation chemistry of methylcyclopentane (MCP), 1,2,3,4-tetrahydronaphthalene (tetralin), and decahydronaphthalene (decalin) in a motored engine at low to intermediate temperatures. The experiment is conducted with variable compression ratio from 4 to 15 at equivalence ratio of 0.25 and fixed intake temperature. Results show dramatically different reactivity in low temperature oxidation for the three compounds. MCP and tetralin show little low temperature reaction prior to autoignition, while decalin shows significant low temperature reactivity. Detailed product analysis showed that conjugate olefins, the olefin having the identical structure with the reactant except the only C=C bond, account for over 70% of the products from MCP and an even higher percentage of the products from tetralin. Tetralin oxidation under the present conditions is essentially oxidative dehydrogenation with little oxygenated cyclic compound being formed. Hydronaphthalenes with various degrees of unsaturation are detected in the products from decalin, but are not as prevalent as in the case of MCP and tetralin, because of the high selectivity toward low temperature chain branching. The ring-opening paths in decalin oxidation are discussed, suggesting that breaking the common C-C bond of the two rings is more likely than opening the two rings one after the other. Methyl substitution on the ring was found to significantly promote the formation of propene relative to ethene. Reaction mechanisms are proposed to explain the major products formed from each compound. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cooling and dietary crude protein affected milk production on heat-stressed dairy cows

Environmental factors, such as temperature and humidity, exert dramatic effects on the production, health, and well-being of lactating dairy cows. Heat-stressed cows undergo a series of homeorhetic adaptations that alters cellular homeostasis and nutrient utilization. As such, the objective of this study was to determine the effects of cooling and dietary crude protein (CP) content on fermentability of rumen inoculum, milk production, and health of heat-stressed cows. It was hypothesized that cooled but not heat-stressed cows would support productivity in response to an increase in dietary CP content. Thirty-six multiparous Holstein cows were randomly assigned to 1 of 4 treatments in a 2 × 2 factorial arrangement (9 cows/treatment). Treatments consisted of cooling (CO) or moderate long-term heat stress (HS) and diets containing low CP content (LCP; 12.5% CP) or moderate CP content (MCP; 16.1% CP) of dry matter. The CO treatment provided heat abatement with sprinklers and fans that came on at > 20.0°C, whereas the HS treatment did not provide sprinklers and fans. Cows were housed in pens in a freestall barn, and treatments were imposed for 21 d during July and August. Compared with the HS treatment, CO decreased afternoon rectal and vaginal temperatures (0.60 and 0.70°C) and afternoon respiration rate (27.6 breaths/min). Treatment interactions showed that compared with the LCP treatment, MCP increased milk fat yield (23%) in CO but not in HS cows. Compared with the LCP treatment, MCP decreased milk protein percent (0.14 units) in CO but increased milk protein percent (0.09 units) in HS cows. Rumen inoculum collected on d 21 showed a ~3-fold increase in total gas production in vitro in CO compared with the HS treatment. Relative to the LCP treatment, MCP increased plasma glucose and insulin and decreased total free fatty acids concentrations. In summary, under the conditions of this study CO but not HS cows responded to a CP stimulus by increasing productivity.

59 BASIC BIOLOGICAL SCIENCES↗

Thromboxane A{sub 2} receptor signaling promotes liver tissue repair after toxic injury through the enhancement of macrophage recruitment

It is thought that thromboxane A{sub 2} (TxA{sub 2}) contributes to the progression of inflammation during acute hepatic injury; however, it is still unknown whether TxA{sub 2} is involved in liver repair. The objective of the present study was to examine the role of TxA{sub 2} receptor (TP) signaling in liver injury and repair in response to toxic injury. Carbon tetrachloride (CCl{sub 4}) was used to induce liver injury in TP knockout (TP{sup −/−}) mice and wild-type (WT) mice. In WT mice, serum levels of alanine aminotransferase (ALT) and the size of the necrotic area peaked at 24 and 48 h, respectively, and then declined. In TP{sup −/−} mice, the changes in ALT levels were similar to WT mice, but liver regeneration was impaired as evidenced by remained elevated levels of hepatic necrosis and by delayed hepatocyte proliferation, which was associated with the reduced expression of growth factors including interleukin-6 (IL-6), tumor necrosis factor alpha (TNFα), and hepatocyte growth factor (HGF). In TP{sup −/−} mice, the accumulation of hepatic CD11b{sup +}/F4/80{sup +} macrophages in injured livers was attenuated, and the hepatic expression of monocyte chemoattractant protein-1 (MCP-1/CCL2) and its receptor, the C―C chemokine receptor (CCR2), was reduced compared to WT. Additionally, the application of the TP receptor agonist, U-46619, enhanced the expression of MCP-1/CCL2 and CCR2 in peritoneal macrophages, which was associated with increased levels of IL-6, TNFα and HGF. These results suggested that TP receptor signaling facilitates liver recovery following CCl{sub 4}-induced hepatotoxicity by affecting the expression of hepatotrophic growth factors, and through the recruitment of macrophages mediated by MCP-1/CCL2-CCR2 expression. -- Highlights: ► TP enhances liver regeneration by CCl{sub 4}. ► TP accumulates macrophages. ► TP up-regulates MCP-1.

60 APPLIED LIFE SCIENCES↗

The role and mechanism of KCa3.1 channels in human monocyte migration induced by palmitic acid

Highlights: • Palmitic acid upregulates K{sub Ca}3.1 channels in human monocytes. • TLR2/4, p38-MAPK and NF-κB pathway is involved in the effect of palmitic acid. • The migration of monocytes induced by palmitic acid is mediated by K{sub Ca}3.1 channels. • K{sub Ca}3.1 channels contribute to palmitic acid-induced MCP-1 production in monocytes. Monocyte migration into diseased tissues contributes to the pathogenesis of diseases. Intermediate-conductance Ca{sup 2+}-activated K{sup +} (K{sub Ca}3.1) channels play an important role in cell migration. However, the role of K{sub Ca}3.1 channels in mediating monocyte migration induced by palmitic acid (PA) is still unclear. Using cultured THP-1 cells and peripheral blood mononuclear cells from healthy subjects, we investigated the role and signaling mechanisms of K{sub Ca}3.1 channels in mediating the migration induced by PA. Using methods of Western blotting analysis, RNA interference, cell migration assay and ELISA, we found that PA-treated monocytes exhibited increment of the protein levels of K{sub Ca}3.1 channel and monocyte chemoattractant protein-1 (MCP-1), and the effects were reversed by co-incubation of PA with anti-TLR2/4 antibodies or by specific inhibitors of p38-MAPK, or NF-κB. In addition, PA increased monocyte migration, which was abolished by a specific K{sub Ca}3.1 channel blocker, TRAM-34, or K{sub Ca}3.1 small interfering RNA (siRNA). The expression and secretion of MCP-1 induced by PA was also similarly prevented by TRAM-34 and K{sub Ca}3.1 siRNA. These results demonstrate for the first time that PA upregulates K{sub Ca}3.1 channels through TLR2/4, p38-MAPK and NF-κB pathway to promote the expression of MCP-1, and then induce the trans-endothelial migration of monocytes.

60 APPLIED LIFE SCIENCES↗

Temporal stability of blue phosphorescent organic light-emitting diodes affected by thermal annealing of emitting layers

Emitting layers were thermally annealed at 20 to 100 °C for varying durations without causing phase transformation in the rest of the PhOLEDs. Heating EMLs above their T g s with a free surface created pinholes filled by the underlying TAPC melt with concurrent interlayer mixing to emit satellite peaks accompanying FIrpic's phosphorescence. With a robust glassy TmPyPB layer on top of the EML, pinholes and fortuitous fluorescence could be prevented. Annealing of mCP:SiPh4:FIrpic induced crystallization in 1 h, while mCP-$\mathscr{L}$-PhSiPh3:FIrpic consistently resisted crystallization under all conditions. Crystallization or pinhole formation diminished EQE and driving voltage at the same time. Without incurring pinhole formation in the absence of a free surface presented by the EML, annealing of mCP:SiPh4:FIrpic at 60 °C for 1 h led to about 50% loss in EQE. In contrast, the pristine device's EQE persisted with mCP-$\mathscr{L}$-PhSiPh3:FIrpic annealed at 60 °C for up to 24 h, beyond which other sources of device failure took over. The concept of bipolar hybrids holds promise for mitigating morphological instability as part of the challenge to the PhOLED device lifetime.

36 MATERIALS SCIENCE↗

Observation of Ultra-Slow Antiprotons using Micro-channel Plate

Our group ASACUSA-MUSASHI has succeeded in accumulating several million antiprotons and extracting them as monochromatic ultra-slow antiproton beams (10 eV-1 keV) at CERN AD. We have observed ultra-slow antiprotons using micro-channel plates (MCP). The integrated pulse area of the output signals generated when the MCP was irradiated by ultra-slow antiprotons was 6 times higher than that by electrons. As a long-term effect, we also observed an increase in the background rate presumably due to the radioactivation of the MCP surface. Irradiating the antiproton beams on the MCP induces antiproton-nuclear annihilations only on the first layer of the surface. Low-energy and short-range secondary particles like charged nuclear fragments caused by the 'surface nuclear reactions' would be the origin of our observed phenomena.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗