Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEDICAL ELECTRONICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Mo-99 Concentration and processing by Solvent Extraction and Ion Exchange

Normally derived from its transient-equilibrium parent molybdenum-99 ( 99 Mo) (t½ = 66 h), the short-lived isotope technetium-99m ( 99m Tc) (t ½ = 6.0 h) is the most widely used medical isotope in diagnostic imaging today. The National Nuclear Security Administration’s (NNSA’s) Material Management and Minimization (M3) program—established under the auspices of the American Medical Isotope Production Act—has been tasked with facilitating the work of domestic 99 Mo suppliers that do not use highly enriched uranium (HEU). Superconducting electron linear accelerators that employ high-Z converter targets can generate bremsstrahlung photons and neutron fluxes that can induce photonuclear reactions and uranium (U) fission. Argonne, in collaboration with industrial partners, has been developing the process chemistry for superconducting linear accelerator (LINAC)-irradiated triuranium octoxide (U 3 O 8 ) targets to produce 99 Mo. In short, the process involves dissolving the irradiated targets in nitric acid, which simultaneously releases valuable fission products (xenon and iodine). After adjusting the acid concentration, producers process the feed using tri-n-butyl phosphate (TBP), then mix the raffinate derived from this extraction cycle with a phosphinic acid such as Cyanex 272 or di(2-ethylhexyl) phosphoric acid (HDEHP), which is selective for Mo (molybdenum liquid liquid extraction [MoLLE]). In the next step, a concentration column comprising an anion exchange platform is used to decontaminate the remaining fission products, generating a pure 99 Mo stream in sodium hydroxide (NaOH)/sodium chloride (NaCl).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Superconducting Accelerators for High-Power X-ray production

To date, linear accelerators (linacs) as electron sources used to produce ionizing radiation for industrial purposes have been limited to less than 100 kW. When the electron beam is used directly, this is sufficient for most potential applications. However, when the electron beam is used for the production of photons (x-rays) which are then to be used in an application, this is not sufficient to compete with other sources of photons (gamma rays from cobalt-60). This paper will discuss acompact superconducting RF (CSRF) accelerator system that relies on emerging technologies that will be able to produce electron beam powers into the 100s of kW with efficiencies much better than present linacs. The focus is to produce x-ray beams for medical device sterilization to provide alternatives for the present use of cobalt-60 for this purpose.

43 PARTICLE ACCELERATORS↗

Compact, high-power superconducting radio-frequency accelerators for environmental applications

Electron-beam irradiation has been proven to destructively reduce or eliminate a wide variety of organic chemicals, viruses and bacteria from wastewater, as well as reducing sulfur and nitrous oxides emission from coal-fired power plants. It is estimated that there are approximately 30,000 such particle accelerators in use worldwide for industrial processes including surface and bulk processing of material, medical sterilization, and environmental remediation. Maximum beam power from accelerators used in these applications is currently limited to less than 500 kW, and a higher beam power is needed to reduce treatment costs. The market availability of continuous-wave (CW) electron-beam accelerators with power of the order of ~100 kW is also very limited. Superconducting radio-frequency (SRF) linear accelerators (linacs) are commonly used at basic research laboratories throughout the world due to their exceptionally high efficiency as compared to current industrial varieties. Recent advances in cryogenics, SRF thin films and high-power magnetrons allow for the design of increasingly compact and efficient CW SRF electron linacs in the energy range 1-10 MeV, with up to 1 MW of beam power. A new class of compact, high-efficiency electron-beam accelerators may provide cost-effective solutions for a range of industrial and environmental remediation applications, particularly with respect to tackling one such class of contaminants so-called “forever chemicals”, including per- and polyfluoroalkyl substances (PFASs), which are ubiquitous in a wide range of products and for which there is currently no effective destruction technology. We have recently demonstrated the key technologies required for such accelerators by: 1) operating a Nb3Sn SRF accelerating cavity cooled by commercial cryocoolers up to an accelerating gradient of 12.4 MV/m and 2) demonstrating the phase-locking as well as a high-efficiency power combining scheme for industrial magnetron transmitters. In this presentation, we will introduce the principles and benefits of MW-class SRF linacs, based on the conduction-cooled SRF technology that we have demonstrated for environmental remediation. We propose the development of a 4 MeV, 20 kW prototype to be built at Jefferson Lab as a first accelerator demonstrator unit. We will also present the results from samples study on the effect of electron-beam irradiation on so-called “forever chemicals” such as 1,4-dioxane and PFAS, using an existing multi-purpose 10 MeV, low-power, CW SRF linac at Jefferson Lab.

Ciovati, Gianluigi↗

Comparative Effects of Radiation Sterilization Modality on Medical PVC Tubing

As the production volume of single-use, polymer-based medical devices increases each year, so does the need for throughput capacity to sterilize the devices. Around 80% of radiation-sterilized devices are processed using gamma-ray radiation from industrial cobalt-60 sources. Supply chain, security, and disposal concerns are prompting manufacturers and contract sterilizers to explore alternatives to irradiation using cobalt-60 gamma-rays, such as electron beam (E-beam) and X-ray radiation. Advantages of these ‘machine’ sources over radioisotope-based sources are that they do not decay, a characteristic that requires cobalt-60 to be replaced over time, they can be turned off when not in use, and they do not represent the same level of concern regarding misuse. One of the barriers to direct transition from gamma-ray sterilization to E-beam or X-ray sterilization is concern over the relatively unknown effects of sterilization dose of these alternative modalities on the performance of medical device polymers. Commercially available medical devices sterilized with gamma-ray irradiation exhibit acceptable device function, acceptable mechanical performance, and acceptable discoloration. To be viable, alternate sterilization methods must not only achieve acceptable sterilization, but the process must also result in a product with functional, mechanical, and visual effects acceptable to customers and the regulator. Flexible polyvinyl chloride (PVC) is a plastic material that is commonly found in single-use medical devices and is known for its sensitivity to radiation processing. For instance, transparent PVC is known to yellow upon irradiation. To encouraging sterilization alternatives to cobalt-60 gamma-ray, we directly compared the effects of gamma-ray, E-beam, and X-ray radiation exposure at similar sterilization-relevant doses on key properties of medical grade PVC tubing.

cobalt-60↗

Trithiol ligand provides tumor-targeting 191 Pt-complexes with high molar activity and promising in vivo properties

The Auger electron-emitting radionuclide 191 Pt is a promising candidate for radiopharmaceutical therapy. Herein, we explored novel labeling methods for 191 Pt using thiol-containing ligands to improve the in vivo stability and targeting ability of 191 Pt-labeled complexes. We synthesized dithiol-containing N 2 S 2 and NS 2 ligands, and a trithiol ligand, and then compared their radiochemical reactivity with 191 Pt. [ 191 Pt]Pt-trithiol was synthesized and its biodistribution was evaluated in mice and compared with free 191 Pt. Finally, a 191 Pt-trithiol complex targeting prostate-specific membrane antigen (PSMA): [ 191 Pt]Pt-trithiol-PSMA was developed and evaluated in mice bearing tumor xenografts and compared with a 191 Pt-complex labeled via monothiol-containing Cys ([ 191 Pt]Pt-Cys-PSMA). A comparison of N 2 S 2 , NS 2 , and trithiol showed that the trithiol ligand is the best for producing 191 Pt-labeled compounds in high yield and as a single peak in preparative HPLC. Notably, the trithiol ligand made 191 Pt-labeled compounds and precursors separatable, achieving 191 Pt-labeled products with a high molar activity: 200–400 mCi/μmol (7.4–14.8 GBq/μmol) at EOS. Additionally, [ 191 Pt]Pt-trithiol and [ 191 Pt]Pt-trithiol-PSMA were stable in vivo with rapid clearance compared with free 191 Pt and [ 191 Pt]Pt-Cys-PSMA. [ 191 Pt]Pt-trithiol-PSMA resulted in a low uptake in most normal organs and a high uptake in the kidneys and prostate cancer with PSMA expression. Furthermore, this study demonstrated that a labeling method with trithiol for Pt radionuclides achieves 191 Pt-labeled products with high molar activity. 191 Pt-trithiol-PSMA showed promising in vivo stability and tumor-targeting specificity, which should facilitate the pharmaceutical development of Pt radionuclides for radiopharmaceutical therapy, especially Auger electron cancer therapy.

Auger emitters↗

Continuous assessment of metabolic activity of mitochondria using resonance Raman microspectroscopy

Dysfunctional mitochondrial activity can lead to a variety of different diseases. As such, there exists a need to quantify changes in mitochondria function as it relates to these specific diseased states. Here, we present the use of resonance Raman (RR) spectroscopy as a tool to determine changes in isolated mitochondrial activity. RR spectroscopy, using 532 nm as the excitation source, specifically provides information on the reduction and oxidation (RedOx) state of cytochrome c, which is determined by the activity of protein complexes in the electron transport chain. In this model, injection of the substrate succinate into the mitochondrial sample is used to drive the electron transport chain, which causes a subsequent change in cytochrome c RedOx state. This change in RedOx state is tracked by RR spectroscopy. We report this tool gives real-time information on the rise and fall of the amount of reduced cytochrome c within the mitochondrial sample, providing a method for rapid assessment of mitochondrial metabolism that has broad applications in both basic science and medical research.

59 BASIC BIOLOGICAL SCIENCES↗

Solvent Recovery and Management at the Savannah River Site H-Canyon Facility

NIOWAVE, Inc. is a domestic supplier of medical and industrial isotopes from uranium and radium. The Savannah River National laboratory (SRNL) is currently providing support to NIOWAVE, which plans to deploy a superconducting electron linear accelerator (LINAC) to fission uranium for Mo-99 production without the need for a nuclear reactor or HEU. The uranium from the Mo-99 production targets will be purified using a modified PUREX (Plutonium Uranium Reduction Extraction) solvent extraction process to recover the uranium in the product stream. The uranium will then be precipitated as an oxalate which is calcined to U 3 O 8 to fabricate pellets for new Mo-99 targets. In previous support provided to NIOWAVE, the SRNL demonstrated a solvent washing process to remove degradation products from the tributyl phosphate (TBP) solvent used in the modified PUREX process under development for uranium recovery. To supplement this technology demonstration, NIOWAVE requested the SRNL to provide summary information on the solvent recovery and management activities which are used at the Savannah River Site (SRS) H-Canyon facility. An existing reference document for the reprocessing of irradiated HEU fuels at the SRS was used as the primary reference for the solvent management activities; although, other reference documents were used to provide supplementary information. The information provided includes a brief summary of the solvent degradation issues which have been observed in the H-Canyon solvent extraction cycles and resulting process safety concerns. The solvent recovery processes for the three cycles of solvent extraction used in the H-Canyon were subsequently described including the process equipment which consists of the continuous and batch solvent washers, pumps, and tanks. A final section is provided on the monitoring and analysis of solvent quality based on the previous work performed at the SRNL for NIOWAVE and past research and development activities performed to support the solvent extraction processes in both the SRS F-Canyon and H-Canyon facilities.

07 ISOTOPE AND RADIATION SOURCES↗

Testing of Helium-Cooled Metal Molybdenum Disk Target

NorthStar Medical Radioisotopes LLC is planning to produce an important medical radioisotope, molybdenum-99 (Mo-99), through photonuclear reaction on molybdenum-100 (Mo-100). In this approach, molybdenum metal will be bombarded with a 40-MeV electron beam. Because enriched Mo-100 is expensive, it is desired to use as much beam power as possible to achieve maximum production yield and minimize target mass. This objective leads to very high beam power density (heat deposition in the target), which sets challenging requirements for cooling. Together with scientists at Los Alamos National Laboratory, a team at Argonne National Laboratory has developed and demonstrated a cooling approach using pressurized helium, which allows for efficient heat removal. One of the main challenges in this approach is the management of the heat load on the target window. The target window separates the high-pressure helium inside the target from the vacuum in the beamline, so it is constantly under stress from differential pressure. Also, the window is cooled only by the helium gas flowing on one side, making the window cooling even more challenging. High heat deposition in the target disks also imposes a strict requirement on performance of the helium cooling system and thickness of the target disks. The target disks are produced from metal powder via a press-and-sinter process. The resulting disks do not possess tensile strength as high as solid molybdenum and might not survive the vibration from the high-velocity helium coolant and high thermal stress from beam heating. An Argonne team of scientists performed a series of tests at Argonne’s Low Energy Accelerator Facility (LEAF) [3-7]. This report describes two series of tests for scale down production target designs that utilize full-scale 29 millimeters diameter, 0.75 mm thick press-and-sintered disks. We performed two thermal tests with different beam parameters and configurations of the disk laminations. We compared the results of the window temperature measurements and cooling system parameters obtained in the experiments with those predicted by analytical calculations and Computation Flow Dynamic (CFD) simulations. Results of the experiments and calculations are presented below.

36 MATERIALS SCIENCE↗

Optical Processes behind Plasmonic Applications

Plasmonics is a revolutionary concept in nanophotonics that combines the properties of both photonics and electronics by confining light energy to a nanometer-scale oscillating field of free electrons, known as a surface plasmon. Generation, processing, routing, and amplification of optical signals at the nanoscale hold promise for optical communications, biophotonics, sensing, chemistry, and medical applications. Surface plasmons manifest themselves as confined oscillations, allowing for optical nanoantennas, ultra-compact optical detectors, state-of-the-art sensors, data storage, and energy harvesting designs. Surface plasmons facilitate both resonant characteristics of nanostructures and guiding and controlling light at the nanoscale. Plasmonics and metamaterials enable the advancement of many photonic designs with unparalleled capabilities, including subwavelength waveguides, optical nanoresonators, super- and hyper-lenses, and light concentrators. Alternative plasmonic materials have been developed to be incorporated in the nanostructures for low losses and controlled optical characteristics along with semiconductor-process compatibility. This review describes optical processes behind a range of plasmonic applications. It pays special attention to the topics of field enhancement and collective effects in nanostructures. The advances in these research topics are expected to transform the domain of nanoscale photonics, optical metamaterials, and their various applications.

2D materials↗

Photonuclear Physics in SCALE

Radiation shielding modeling involves a wide range of applications, such as power reactors, critical experiments, portable sources, linear accelerators, and fusion systems. Particle energy ranges vary from thermal energies to fast energy spectra. MAVRIC, as the radiation shielding sequence of the SCALE code system [1] developed and maintained by Oak Ridge National Laboratory, is capable of modeling both neutron and photon interactions in matter and is widely used by the US Nuclear Regulatory Commission, Department of Energy, the National Nuclear Security Administration, and radiation shielding practitioners all around the world. Although most applications don’t involve highly energetic photons that can cause photonuclear reactions and create coupled chains of high energy, ionized electrons and bremsstrahlung radiation within a material medium, when present, these reactions can have a significant impact upon the downstream particle fluxes from incident photons above 20 MeV. For example, linear accelerators used for medical isotope production are examples of applications in which high-energetic photons are generated and used for driving or controlling other components of a complex facility. Radiation shielding analyses of such a facility would require accounting for any and all significant sources of radiation. Unfortunately, MAVRIC included no data and methods to model either photonuclear reactions or the bremsstrahlung photons until this work, which enabled accounting for both. Photonuclear reaction cross sections were imported from the Evaluated Nuclear Data File libraries, and corresponding methods were implemented in the SCALE code system; see Section 2 for how the nuclear data are imported and used. Bremsstrahlung photons were modeled by assuming thick-target approximation whereby all generated electrons and positrons due to photon interactions are assumed to be absorbed within the same material in which they were born, yielding a quick particle transport simulation method by using fast lookup tables for generating subsequent gammas; see Section 4 for details. A suite of verification models was used to test implemented methods and associated data. Tests yielded satisfactory results for the new features. Enhancements will be released as part of the next major SCALE release (v7.0), which is anticipated to be deployed in 2025, with beta releases available in the interim.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Apparatus for preparing medical radioisotopes

Apparatus for radioisotope production includes housing, a plurality of target disks inside the housing and a curved windows positioned convex inward toward the disks. During operation, coolant flows though the housing across the disks and windows while electron beams passes through the window and the disks. The window temperature increases, rising the fastest in the middle of the window where the electron beam hits the window. A flat window would buckle because the center would deform during thermal expansion against the relatively unaffected periphery, but the curved window shape allows the window to endure high thermal and mechanical stress created by a combination of heating from the electron beam(s) and elevated pressure from coolant on the inside of the window. Such a window may be used for applications in which a pressurized coolant acts on only one side of the window.

Woloshun, Keith A.↗

Numerical Analysis and Flow Induced Vibration Studies in Pressurized Helium Gas Cooling Channels

Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 from the irradiation of Mo-100 targets. The NMR target consists of an Inconel window that allows the electron beam to penetrate and irradiate a stack of Mo-100 discs. The irradiation process generates large amounts of heat and is cooled using pressurized helium gas flowing at 400 g/s. LANL provides both numerical analysis support and experimental support. Computational fluid dynamics (CFD) simulations for both 300 g/s and 400 g/s are performed on the NMR target to analyze the helium flow through the NMR system. The pressure drop, the mass flow rate through each of the disc and window channels and the force applied on the first disc are some of the quantities estimated using CFD. These results will be combined with Monte Carlo N-Particle (MCNP) estimates of heat flux into the system from the electron beam to perform conjugate heat transfer analysis (CHT). The experiments presented in this report focus on the effect of the flow induced vibrations from helium flowing through the coolant gaps between the discs. There is concern that the flow induced vibrations may lead to excessive mass loss of the enriched Mo-100 discs, and the goal would be to mitigate the mass loss. This work presents benchtop tests of flow through a subset of the target stack which involves high speed imaging and displacement measurements used to estimate disc vibration, as well as mass loss.

42 ENGINEERING↗

Conjugate Heat Transfer Analysis in Pressurized Helium Gas Cooling Channels

Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 from the irradiation of Mo-100 targets. The NMR target consists of an Inconel window that allows the electron beam to penetrate and irradiate a stack of Mo-100 disks. The irradiation process generates large amounts of heat and is cooled using pressurized helium gas flowing at 400 g/s. LANL provides both numerical analysis support and experimental support. Computational fluid dynamics (CFD) and conjugate heat transfer (CHT) analysis are performed on the NMR target to analyze the helium flow and volumetric heating through the NMR system. In this iteration of numerical analysis, we update the Mo-100 disk thickness to 0.74 mm and the gap between the Inconel window and the first disk to 0.69 mm. Estimates of the heat flux from the electron beams from Monte Carlo N-Particle code (MCNP) analysis were combined with CFD to perform the CHT analysis. The pressure drop through the targets, force applied on the first disk, beam window and target disk temperatures are some of the quantities estimated using the simulations. The pressure drop through the target was estimated as 0.198 MPa, while the force due to venturi effects across the first disk was estimated to be 100 N. The results show maximum window temperatures over 600 °C and peak disk temperatures over 1600 °C. Past work has shown that beyond 650-700 °C, the Inconel window becomes susceptible to yield and rupture. The increased temperature in these results reduces the margin of error possible on beam spot size. The disk temperatures showed a sinusoidal distribution with the 6 th – 8 th disk from each window exhibiting highest disk temperatures. The peak temperature of the stainless steel housing was close to 316 °C and that of the laminations and spacers was approximately 582 °C.

43 PARTICLE ACCELERATORS↗

Nonlinear electronic excitation in water under proton irradiation: a first principles study

Nonlinear dynamics of electronic excitation bridge physical and physicochemical stages of water radiolysis under proton irradiation, a multi-scale physicochemical process that is fundamental to a wide range of technological and medical applications of high-energy protons. We study the spatial and temporal changes to the excited holes generated in this ionization event using first-principles theory simulation. A significant majority of holes are formed in the immediate vicinity of the irradiating proton paths, and these holes decay rapidly, while secondary excitations are simultaneously induced in regions farther away. While the hole population remains constant, the observed spatially spreading hole distribution cannot be described as concentration-dependent diffusion current. Compared to the primary excitation induced by the irradiating protons, the secondary excitation farther away is somewhat less energetic. Here, the first-principles theory simulation here provides a detailed description of how the primary excitation by proton radiation precedes the formation of cationic holes, which undergo ultrafast chemical processes in water radiolysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advancing flexible electronics and additive manufacturing

There is high interest in the synergism of thin-film and flexible electronics with additive manufacturing. This review primarily focuses on the prospective developments in convergence with flexible electronics manufacturing technologies. Specifically, this paper covers the latest 3D printing and hybrid manufacturing technologies, the utility of specific types of materials, their functionalization and characterization, post-processing and testing strategies toward fabricating robust and application-specific flexible electronics. Besides exploring the advances in this area of research—it also highlights the limitations and gaps that have been observed in the previous years that will challenge and offer opportunities for advancing research and development. Lastly, the future of 3D-printed flexible electronics is discussed in the aspects of customizability, scalability, and its game-changing and state-of-the-art potential for intelligent sensing, instrumentation, and wearables for various medical, engineering, and industrial applications.

36 MATERIALS SCIENCE↗

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cross Section Measurements of Photonuclear Reaction Pathways Towards Promising Medical Radioisotopes

Project Objectives: The goal of this project was to generate data relevant to radioisotope production while developing innovative technologies that foster and enhance novel production of radioisotopes, and, also, while providing opportunities for cultivating and training future generations of scientists. This work has provided the foundation for methodologies for determination of photonuclear cross sections over multiple energies in a single irradiation. Simultaneously, the feasibility of electron LINAC production of several in-demand radioisotopes such as 47 Sc, 67 Cu, 77 As, and 186 Re has been demonstrated. To accomplish these objectives a collaboration was formed between two complimentary facilities, the Low Energy Accelerator Facility (LEAF) at Argonne National Laboratory and the High Intensity Gamma-ray Source (HIGS) at Triangular Universities Nuclear Laboratory (TUNL). The involvement of the research group from North Carolina Central University gave students at this Historically Black University experience in forefront nuclear-physics research relevant to addressing a high-priority interdisciplinary issue. Project Description: HIGS provides a nearly monoenergetic gamma-ray beam by intra-cavity Compton backscattering of free-electron photons from electrons circulating in a storage ring. This beam can be collimated to produce a very precise energy beam. If the beam is un-collimated a calculated and precise energy spread of the beam occurs radially. The γ-flux can be evenly distributed over the radial distribution of energy and used to perform activation experiments on concentric ring targets. Thus providing multiple energy ranges in a single irradiation. Each concentric ring target can be counted separately in order to determine activation at the given energy and successively be correlated to the activation cross section. Targets were activated to determine production feasibility using electron beams at LEAF. Potential Impact: The Nuclear Science Advisory Committee recently named production of radioisotopes with electron LINACs as one of the most compelling and largest-impact opportunities for the production of high specific activity radioisotopes. Improving the photonuclear cross sectional data base with experimentally verified results will greatly enhance a researcher’s ability to rationalize electron LINAC production routes towards desired radioisotopes. This work will provide the foundation for methodologies for determination of photonuclear cross sections over multiple energies and multiple targets in a single irradiation. The techniques developed in this project will enable future studies to continue verifying theoretically predicted photonuclear cross section with experimental results. These data will also enable adaptation of models and support more precise theoretical calculation of photonuclear cross sections. This research will involve undergraduates, graduate students, and post-docs to give them a valuable research experience leading towards the next generation of scientists in the field of medical isotopes.

07 ISOTOPE AND RADIATION SOURCES↗