Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Gamma-ray line emission above 8 MeV

The spectra of energetic nuclei within astrophysical sources may be determined by studying gamma-ray line emissions above 8 MeV. Excited states which can be produced by inelastic scattering, charge exchange, and spallation reactions in the abundant nuclear species were considered in order to identify nuclear lines which may contribute to the gamma spectrum. The cross sections for production of most high-energy states are sparsely measured. Those which were determined are comparable to the cross section for production of the 15.11 MeV level in C-12 with few exceptions. The branching ratios for gamma-ray and particle emission are, however, better known. Of those states considered, 44 measured branching ratios greater than 40% for emission of a gamma-ray with energy above 8 MeV. For twelve more states the branching ratios, although not yet determined, are expected to be small. The gamma-ray emission from other individual nuclear states is not likely to be as great as that that for the 15.11 MeV state in C-12.

Crannell, C. J.↗

Gamma-rays of 3 to 25 MeV from the galactic anti-center and pulsar NP 0532

Gamma-rays of 3 to 25 MeV are reported from the galactic anticenter region and the Crab Pulsar, NP 0532. The observations were carried out from Palestine, Texas, on May 13, 1975. Gamma-rays from the galactic anticenter were observed as the Crab Nebula passed overhead within 10 deg of the zenith. Pulsed gamma-rays from NP 0532 were observed at a 4.4-sigma significance level. The total flux from 3-25 MeV is 0.0049 + or - 0.002 photon/sq cm-sec. The pulsed flux from NP 0532 from 3 to 25 MeV is 0.00043 + or - 0.00026 photon/sq cm-sec. The ratio of the total to the pulsed flux from 3 to 25 MeV is 11 + or - 8.

Wilson, R. B.↗

Observation and search for gamma rays 1-20 MeV from the Crab, NGC 4151, Cyg X-1, Cyg X-3, CG 135+1 and 3C 273

Observations and limiting values for the flux of 1-20 MeV gamma rays from the Crab, the Seyfert galaxy NGC 4151, the black hole candidate Cyg X-1, Cyg X-3 and the two nearest quasars CG 135+1 and 3C 273 are reported. Measurements of the energy and scatter angle of gamma rays at zenith angles between 10 and 30 deg were obtained by a balloon-borne double-scatter gamma-ray telescope. The flux from the Crab from 1.2 to 10 MeV is found to be 0.0039 + or - 0.0020 photons/sq cm per sec, and the energy distribution of the flux from 1.2 to 20 MeV is determined. Two-standard-deviation upper limits to the gamma-ray flux in the intervals 1.2-3, 3-5, 5-10 and 10-20 MeV of 0.0003, 0.0002, 0.00006 and 0.00004 photons/sq cm/sec are found for NGC 4151, Cyg X-1 and Cyg X-3, while those of 0.0005, 0.0003, 0.0001 and 0.00004 photons/sq cm per sec are determined for both quasars. These upper limits are interpreted as restricting confirmed gamma-ray sources to the Crab and NP 0532, and as evidence against Seyfert galaxies as the source of cosmic diffuse radiation.

White, R. S.↗

Gamma rays of 0.3-30 MeV from PSR0833 - 45

Pulsed gamma rays from the Vela pulsar PSR0833 - 45 are reported for the first time over the medium energy range 0.3-30 MeV. They were observed with a double scatter gamma-ray telescope flown on a balloon over Australia on Nov. 10, 1981, 31 days after a large glitch in the pulsar period. The first and second pulses were detected from single scatters in the top scintillators at energies over 0.3 MeV with statistical significances of 1.6 sigma each, and by double scatters from all detector cell pairs at energies of 1-30 MeV with significance of 4.8 sigma and 3.8 sigma. The phase separation of the two pulses is 0.43 + or - 0.02 at the same absolute phases previously found by SAS2 and COS B for energies over 35 MeV.

Tumer, O. T.↗

Gamma rays of 1-30 MeV from the Vela Pulsar PSR 0833-45

Results are reported for observations of gamma rays of 1-30 MeV from the Vela Pulsar PSR 0833 - 45 carried out with the UCR double scatter gamma ray telescope on a balloon launched from Alice Springs, Australia on November 10, 1981. An integrated flux of (5.3 + or - 1.3) x 10 to the -4th photons/sq cm/s is found for the Vela region above 2 MeV. This value, together with those for the energy intervals of 2-4, 4-7, and 7-15 MeV are in reasonable agreement with the power law found by COS-B at energies above 50 MeV. A sky contour map of the fluxes is shown.

Tumer, T.↗

High sensitivity high resolution double scatter 1-30 MeV gamma ray telescope

The design and performance of the double-scatter 1-30-MeV gamma-ray telescope developed at the University of California for balloon-borne observations are reported and illustrated with drawings, diagrams, and graphs. The telescope comprises an upper array of 16 6.03 x 6.03 x 100-cm plastic scintillator bars viewed by photomultiplier tubes (PMTs) at both ends, a lower array (at 100-cm distance) of 16 4.83 x 4.83 x 100-cm NaI(Tl) bars viewed at both ends by PMTs, and four 122 x 122 x 0.64-cm plastic sheets viewed by four PMTs each as charged-particle anticoincidence shielding. The operating principle of the telescope, the tests conducted on the NaI(Tl) bars, the on-board data-processing electronics, and the overall performance are characterized. Performance parameters include area 1 sq m, field of view pi sr, 4-sigma sensitivity above 1 MeV 0.00004 gamma/sq cm sec over 25 h, angular resolution about 3.5 deg FWHM, and energy resolution 10 percent at 1 MeV and 6 percent at 6 MeV.

Zych, A. D.↗

DLTS analysis of radiation-induced defects in one-MeV electron irradiated germanium and Alsub0.17Gasub0.83As solar cells

The radiation-induced deep-level defects in one-MeV electron-irradiated germanium and AlxGal-xAs solar cell materials using the deep-level transient spectroscopy (DLTS) and C-V techniques were investigated. Defect and recombination parameters such as defect density and energy levels, capture cross sections and lifetimes for both electron and hole traps were determined. The germanium and AlGaAs p/n junction cells were irradiated by one-MeV electrons. The DLTS, I-V, and C-V measurements were performed on these cells. The results are summarized as follows: (1) for the irradiated germanium samples, the dominant electron trap was due to the E sub - 0.24 eV level with density around 4x10 to the 14th power 1/cu cm, independent of electron fluence, its origin is attributed to the vacancy-donor complex defect formed during the electron irradiation; (2) in the one-MeV electron irradiated Al0.17Ga0.83 as sample, two dominant electron traps with energies of Ec-0.19 and -0.29 eV were observed, the density for both electron traps remained nearly constant, independent of electron fluence. It is shown that one-MeV electron irradiation creates very few or no new deep-level traps in both the germanium and AlxGa1-xAs cells, and are suitable for fabricating the radiation-hard high efficiency multijunction solar cells for space applications.

Li, S. B.↗

A search for gamma rays of 1.5-20.0 MeV from Centaurus A

A search for a gamma-ray continuum and lines from Centaurus A is reported. No measurable gamma rays are found in the 1.5-20.0 MeV and 3 sigma upper limits are reported for various energies which are about a factor of two lower than the results reported by von Ballmoos et al. (1987). These upper limits, along with those of SAS 2 and COS B, suggest that the energy distribution turns over in the energy range of 500 keV to a few MeV. A high source temperature of 5 MeV or synchrotron self-Compton models for producing an excess of gamma rays of a few MeV do not appear necessary.

O'Neill, Terrence↗

High-Energy (> 40 MeV) Proton Intensity Enhancements Associated with the Passage of Interplanetary Shocks at 1 au

We analyze periods with elevated >40 MeV proton intensities observed near Earth over a time span of 43 years (1973-2016) that coincide with the passage of interplanetary shocks. Typically, elevated proton intensities result from large solar energetic particle (SEP) events. The interplanetary shocks observed during these elevated-intensity periods may or may not be related to the origin of the SEP events. By choosing those cases when the shocks can be confidently associated with the solar eruption that generated the SEP event, we analyze the components of these SEP events that are localized in the vicinity of the shock (so-called “energetic storm particles (ESPs)"), focusing on those events where the ESP component exceeds 40 MeV. We examine the interdependence of these high-energy ESPs with (i) the properties of the solar eruptions that generated the shocks and the SEP events, and (ii) the parameters of the shocks at their arrival at 1 au. The solar eruptions at the origin of the shocks producing >40 MeV proton ESP intensity enhancements are within ±50° longitude of central meridian and are associated with fast coronal mass ejections (plane-of-sky speeds ≳1000 km s -1 ). The ESP events with the largest >40 MeV proton intensity increases tend to occur when there are structures such as intervening interplanetary coronal mass ejections and other unrelated shocks present in the solar wind through which the shock is propagating. Among the various local shock parameters considered, only the shock speed shows a certain degree of correlation with the observed ESP intensity increase.

Solar energetic particles↗

Characterizing the energy resolution of the MicroBooNE LArTPC at the MeV scale using monoenergetic features of $^{208}$Tl decays

A detailed understanding of the capabilities and fidelity of low-energy reconstruction is crucial for taking advantage of MeV-scale neutrino physics opportunities in liquid argon time projection chambers (LArTPCs). This study presents a measurement of the resolution of reconstructed energy in the MicroBooNE LArTPC at $\approx 1.5$ MeV. The characterization is performed using monoenergetic signals generated by $2.614$ MeV $γ$-rays from $^{208}$Tl decays undergoing pair production in the detector. The resolution is found to be ($7.52 \pm 0.78 \text{(stat)} \pm 0.92 \text{(syst)}$)%. This value is consistent with the MicroBooNE simulation prediction of ($9.70 \pm 0.65 \text{(stat)}$)% at the $1.6 σ$ level. This study represents the first ever measurement of LArTPC energy resolution at the MeV scale and provides a pathway for monoenergetic energy calibrations in future experiments using LArTPC detectors.

Abratenko, P. [Tufts U.]↗

COCOA: A compact Compton camera for astrophysical observation of MeV-scale gamma rays

COCOA (COmpact COmpton cAmera) is a next-generation gamma-ray telescope designed for astrophysical observations in the MeV energy range. The detector comprises a scatterer volume employing the LiquidO detection technology and an array of scintillating crystals acting as absorber. Surrounding plastic scintillator panels serve as a veto system for charged particles. The detector's compact, scalable design enables flexible deployment on microsatellites or high-altitude balloons. Gamma rays at MeV energies have not been well explored historically (the so-called "MeV gap") and COCOA has the potential to improve the sensitivity in this energy band.

79 ASTRONOMY AND ASTROPHYSICS↗

Response of the Verwey transition in magnetite to controlled point-like disorder induced by 2.5 MeV electron irradiation

Controlled point-like disorder induced by low temperature 2.5 MeV electron irradiation was used to probe the nature of the Verwey transition in magnetite, Fe 3 O 4 . Two large single crystals, one with optimal transition temperature, T V ≈ 121 K, and another with T V ≈ 109 K, as well as magnetite magnetosome nanocrystals harvested from the lysed cells of the marine magnetotactic vibrio Magnetovibrio blakemorei strain MV-1, T V ≈ 110 K, were examined. Temperature-dependent resistivity is consistent with the semiconductor-to-semiconductor (insulator) sharp, step-like Verwey transition from a state with a small bandgap of around 60 meV to a state with a large bandgap of about 300 meV. The irradiation causes an up-shift of the resistivity curves above the transition without transition smearing or broadening. It also causes an apparent down-shift of the resistivity maximum at high temperatures. In the lower crystal, the electron irradiation drives the transition temperature into a “forbidden” interval of T V , believed to separate the first order from the second order phase transition. Contrary to this belief, the transition itself remains sharp and hysteretic without a significant change in the hysteresis width indicating the strong 1st order character of the Verwey transition for all TV values. The separate 2nd order - looking transition is likely due to sample inhomogeneities. Here we conclude that the sudden change of the bandgap accompanied (or driven) by the monoclinic distortion and the change of magnetic anisotropy is the reason for the Verwey transition in magnetite and the effect of additional disorder is mostly in the smearing of the sharp gap edges near the Fermi level.

36 MATERIALS SCIENCE↗

Lineshape response of plastic scintillator to pair production of 4.44 MeV γ’s

We measure the distribution of energy deposited in a 40 × 88 mm plastic scintillator by e + e – pair production of 4.44 MeV γ-rays. He, we observe the double-escape peak of 3.42 MeV from pair production by tagging 511 keV annihilation radiation in two high-Z scintillators. The source is a standard commercial neutron source using α-emitting 241 Am encapsulated with 9 Be, which has a reaction branch feeding the first I π = 2 + state of 12 C making the 4.44 MeV γ-rays. We demonstrate the extraction of the double-escape peak from the large neutron-produced backgound, and explore some of the features and difficulties of this technique with our apparatus.

Beta calibration↗

Multiple Coulomb scattering in acrylic of a 221.3 MeV therapeutic proton beam

Measurements of multiple Coulomb scattering (MCS) distributions for 221.3 MeV therapeutic protons are presented using a novel detector system comprised of a thin scintillator, a pellicle mirror, and a digital camera. The MCS distributions were characterized for three acrylic phantoms of varying lengths and for two biological density-equivalent phantoms simulating bone and muscle. Additionally, beam profiles were measured across an energy range of 80.3–221.3 MeV in 20 MeV increments. The observed energy dependence of the photon yields is consistent with the tabulated stopping power values. Finally, the experimental results are benchmarked against Geant4 simulations, demonstrating consistent agreement and validating the capability of the detector system for radiology measurements.

Digital camera↗

Multi-objective Bayesian active learning for MeV-ultrafast electron diffraction

Ultrafast electron diffraction using MeV energy beams(MeV-UED) has enabled unprecedented scientific opportunities in the study of ultrafast structural dynamics in a variety of gas, liquid and solid state systems. Broad scientific applications usually pose different requirements for electron probe properties. Due to the complex, nonlinear and correlated nature of accelerator systems, electron beam property optimization is a time-taking process and often relies on extensive hand-tuning by experienced human operators. Algorithm based efficient online tuning strategies are highly desired. Here, we demonstrate multi-objective Bayesian active learning for speeding up online beam tuning at the SLAC MeV-UED facility. The multi-objective Bayesian optimization algorithm was used for efficiently searching the parameter space and mapping out the Pareto Fronts which give the trade-offs between key beam properties. Such scheme enables an unprecedented overview of the global behavior of the experimental system and takes a significantly smaller number of measurements compared with traditional methods such as a grid scan. This methodology can be applied in other experimental scenarios that require simultaneously optimizing multiple objectives by explorations in high dimensional, nonlinear and correlated systems.

43 PARTICLE ACCELERATORS↗

Compact spectroscopy of keV to MeV X-rays from a laser wakefield accelerator

We reconstruct spectra of secondary X-rays from a tunable 250–350 MeV laser wakefield electron accelerator from single-shot X-ray depth-energy measurements in a compact (7.5 × 7.5 × 15 cm), modular X-ray calorimeter made of alternating layers of absorbing materials and imaging plates. X-rays range from few-keV betatron to few-MeV inverse Compton to > 100 MeV bremsstrahlung emission, and are characterized both individually and in mixtures. Geant4 simulations of energy deposition of single-energy X-rays in the stack generate an energy-vs-depth response matrix for a given stack configuration. An iterative reconstruction algorithm based on analytic models of betatron, inverse Compton and bremsstrahlung photon energy distributions then unfolds X-ray spectra, typically within a minute. We discuss uncertainties, limitations and extensions of both measurement and reconstruction methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Robust unfolding of MeV x-ray spectra from filter stack spectrometer data

Here, we present an inversion method capable of robustly unfolding MeV x-ray spectra from filter stack spectrometer (FSS) data without requiring an a priori specification of a spectral shape or arbitrary termination of the algorithm. Our inversion method is based upon the perturbative minimization (PM) algorithm, which has previously been shown to be capable of unfolding x-ray transmission data, albeit for a limited regime in which the x-ray mass attenuation coefficient of the filter material increases monotonically with x-ray energy. Our inversion method improves upon the PM algorithm through regular smoothing of the candidate spectrum and by adding stochasticity to the search. With these additions, the inversion method does not require a physics model for an initial guess, fitting, or user-selected termination of the search. Instead, the only assumption made by the inversion method is that the x-ray spectrum should be near a smooth curve. Testing with synthetic data shows that the inversion method can successfully recover the primary large-scale features of MeV x-ray spectra, including the number of x-rays in energy bins of several-MeV widths to within 10%. Fine-scale features, however, are more difficult to recover accurately. Examples of unfolding experimental FSS data obtained at the Texas Petawatt Laser Facility and the OMEGA EP laser facility are also presented.

47 OTHER INSTRUMENTATION↗

Diagnostic development and needs for laser driven MeV x-ray radiography

Laser-driven MeV x-ray radiography of dynamic, dense objects demands a small, high flux source of energetic x-rays to generate an image with sufficient quality. Understanding the multi-MeV x-ray spectrum underscores the ability to extrapolate from the current laser sources to new future lasers that might deploy this radiography modality. Here, in this study, we present a small study of the existing x-ray diagnostics and techniques. We also present work from National Ignition Facility-Advanced Radiographic Capability, where we deploy three diagnostics to measure the x-ray spectrum up to 30 MeV. Finally, we also discuss the needs and developments of two new diagnostics: a single crystal scintillator spectrometer and a fast decay activation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗